• Title/Summary/Keyword: Arc Chamber

Search Result 143, Processing Time 0.027 seconds

Dosimetric Comparison of One Arc & Two Arc VMAT Plan for Prostate cancer patients (Prostate Cancer 환자에 대한 One Arc와 Two Arc VMAT Plan의 선량 측정 비교 분석)

  • Kim, Byoung Chan;Kim, Jong Deok;Kim, Hyo Jung;Park, Ho Chun;Baek, Jeong Ok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.107-116
    • /
    • 2018
  • Purpose : Intensity-modulated radiation therapy(IMRT) has been widely used for radiation therapy of Prostate Cancer because it can reduce radiation adverse effects on normal tissues and deliver more dose to the Prostate than 3D radiation therapy. Volumetric modulated arc therapy(VMAT) has been widely used due to recent advances in equipment and treatment techniques. VMAT can reduce treatment time by up to 55 % compared to IMRT, minimizing motion error during treatment. Materials and Methods : In this study, compared the MU and DVH values of 10 patients with prostate cancer by classifying them into 4 groups with 5 LN-Prostate groups and 5 Only-Prostate. And DQA measurements were performed using ArcCHECK and MapCHECK. Results : The results of Target and OAR dose distribution of Prostate patients are as follows. $D_{max}$ was in the range of 100~110 % in 4 groups, and more than 110 % of hot spot was not seen. Only-Prostate ($P_1$, $P_2$) without LN had a satisfactory dose distribution for the target dose, but slightly better for 2 arc plan($P_2$) than 1 arc plan($P_1$). The target dose $D_{98%}$ distribution in the LN-Prostate ($P_{L1}$, $P_{L2}$) group showed better 2 arc plan($P_{L2}$) than 1 arc plan($P_{L1}$), But in the case of 1 arc plan($P_{L1}$), the target dose $D_{98%}$ value was not enough. In OAR, the dose distribution of 1 Arc($P_1$) Plan and 2 Arc($P_2$) Plan in the Only-Prostate ($P_1$, $P_2$) Group satisfied the prescribed dose value. But, The dose distribution of 1 arc($P_1$) was slightly higher. In LN-Prostate OAR, 1 Arc($P_{L1}$) Plan showed higher dose than the prescribed dose. The Gamma evaluation pass rate of ArcCHECK and MapCHECK calculated from the DQA measurements was slightly higher than 99 % and the mean error range of the point dose measurements using the CC04 ion chamber was less than 1 %. Conclusion : In this study, Only-Prostate ($P_1$, $P_2$) group, the dose of 2 Arc plan was better. However, considering the treatment time and MU value, 1 Arc treatment method was more suitable. In the LN-Prostate ($P_{L1}$, $P_{L2}$) group, 2 Arc($P_{L2}$) treatment method showed better results and satisfied with Target $D_{98%}$ and OAR prescription dose.

  • PDF

The welding Characteristics of the Insertion Device Vacuum Chamber of PLS Storage Ring (가속기 저장링 삽입장치 진공 챔버의 용접)

  • 최만호;한영진;김창균;정진화;권영각
    • Journal of Welding and Joining
    • /
    • v.17 no.4
    • /
    • pp.32-38
    • /
    • 1999
  • PAL(Pohang Accelerator Laboratory) designed and manufactured a 5m-long straight vacuum chamber to adopt U7 undulator that is the first insertion device. Top and bottom plates of the vacuum chamber were made of Al alloy A5083-H321, and welded together by the GTAW welding. The leak rate is less than 1×{TEX}$10^{-10}${/TEX} torr·ℓ/s with negligible welding deformation. The pressure has been maintained below {TEX}$10^{-10}${/TEX} torr after installation. This paper reports the welding process and the method applied to achieve ultimate vacuum performance and t satisfy integrity of welds.

  • PDF

A Study of Process factors on the Recycling of Reactive Metal Scraps in Plasma Arc Remelting (Plasma Arc Remelting에서 활성 금속 Scrap 재활용에 미치는 공정인자의 연구)

  • Jung, Jae-Young;Sohn, Ho-Sang
    • Resources Recycling
    • /
    • v.26 no.6
    • /
    • pp.3-9
    • /
    • 2017
  • In this study, plasma arc remelting behaviors according to arc current, arc voltage, and types of plasma gas were investigated using Kroll processed Ti sponges as anode. In the discharge pressure range of vacuum pump ($200{\sim}300kgf/cm^2$), the arc voltage did not vary greatly with the increase of discharge pressure at a given arc length. This means that the pressure in the vacuum chamber during operation hardly changes and the atmospheric pressure maintains. Under various conditions of arc currents (700~900A), the arc voltage slightly increased with arc current. The effects of anode materials and operational variables on the arc length-arc voltage relationship were compared with the results in previous studies. When the atmospheric gas changed from argon to helium, double effect of improvement on the output of the steady state was observed. The increase of output in the plasma arc device was accompanied by an increase in the melting rate of the Ti sponge and the quality of the ingot surface was also improved. The plasma arc remelting of the new scrap titanium and the old scrap zirconium alloy could result in the fabrication of an ingot with high surface quality.

Operational Envelope of a 150 kW Huels Type Arc-jet

  • Na, Jae-Jeong;Moon, Kwan-Ho;Hong, Yun-Ky;Baek, Seung-Wook;Park, Chul
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.187-195
    • /
    • 2006
  • In this work, we introduce a newly constructed arc-jet device of 150 kW input power. The design of this device is a Huels type with a narrow downstream electrode. General features of this device are first described. From the measured values of electrical power input, heat discharged into cooling water, gas flow rate, and settling chamber pressure, average enthalpy was determined using the heat balance and sonic throat methods. Using the settling chamber pressure and average enthalpy values, the flow properties in the nozzle and the heat transfer rate to the stagnation point of a blunt body are calculated accounting for thermochemical nonequilibrium. The envelope of enthalpy, pressure, degree of dissociation, and heat transfer rate are presented. Stagnation temperature is predicted to be between 4630 to 6050 $^{\circ}K$, and the stagnation point heat transfer rate is predicted to be between 175 and 318 W/$cm^{2}$ for a blunt body of 3 mm nose radius. Degree of dissociation in the stagnation region of the blunt body exceeds 30%.

  • PDF

Methods for Increasing the Interrupting Performance of Are Chamber in 460V / 50KA / 100AF Molded Case Circuit Breaker (460V / 50KA / 100AF 급 배선용 차단기의 소호부 차단 성능 향상 방법)

  • Cho, Sung-Hoon;Jung, Eui-Hwan;Lee, Han-Ju;Lim, Kee-Joe;Kim, Kil-Sou
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.105-105
    • /
    • 2010
  • Voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. Power distribution system requires the transformer with higher capacity than ever, but this ever, but this may be the cause. of the increasing of short circuit current in contrast to conventional one when short-circuit accident is occurred. Therefore molded case circuit breaker improved in aspects of interrupting capacity of short circuit current in this system is needed. By using the proposed methods in this paper, such as new arc quenching structure of grid would contribute to minimizing the MCCB, realization of high interrupting performance and reducing the design time and development cost.

  • PDF

Confirmation of the Dose Distribution by Stereotactic Radiosurgery Technique with a Multi-purpose Phantom (다용도 팬톰에서 정위방사선수술기법의 선량 정확도 확인)

  • Yoo Hyung Jun;Kim Il Han;Ha Sung Whan;Park Charn Il;Hur Sun Nyung;Kang Wee-Saing
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.179-185
    • /
    • 2002
  • Purpose : For the purpose of quality assurance of self-developed stereotactic radiosurgery system, a multi-purpose phantom was fabricated, and accuracy of radiation dose distribution during radiosurgery was measured using this phantom. Materials and Methods : A farmer chamber, a 0.125 cc ion chamber and a diode detector were used for the dosimetry. Six MV x-ray from a linear accelerator (CL2100C, Varian) with stereotactic radiosurgery technique (Green Knife) was used, and multi-purpose phantom was attached to a stereotactic frame (Fisher type). Dosimetry was done by combinations of locations of the detectors in the phantom, fixed or arc beams, gantry angles $(20^{\circ}\~100^{\circ})$, and size of the circular tertiary collimators (inner diameters of $10\~40\;mm$). Results : The measurement error was less than $0.5\%$ by Farmer chamber, $0.5\%$ for 0.125 cc ion chamber, and less than $2\%$ for diode detector for the fixed beam, single arc beam, and 5-arc beam setup. Conclusion : We confirmed the accuracy of dose distribution with the radiosurgery system developed in our institute and the data from this study would be able to be effectively used for the improvement of quality assurance of stereotactic radiosurgery or fractionated stereotactic radiotherapy system.

Investigation on $SF_6$ Hybrid Interrupter using Thermal Expansion and Arc Rotation Principle (자력팽창 및 아크 회전에 의한 배전급 $SF_6$ 복합소호부 개발 연구)

  • Lee, B.W.;Sohn, J.M.;Kang, J.S.;Choe, W.J.;Kim, Y.K.;Seo, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.919-921
    • /
    • 2000
  • This paper considers the research of the hybrid interrupter which adopts both rotating arc and thermal expansion technology. The operating principle of this device depends on rapid arc rotation due to the magnetic field created by the fault current through a coil which is mounted on contacts and also relies on the principle of thermal expansion created by arc energy in extinguishing chamber and finally causes pressure rise in expansion volume. In this research, the principle of the interrupting techniques are given and experimental results of hybrid interrupter which is developed by new technology is introduced.

  • PDF

The Effect of $N_2O$ treatment and Cap Oxide in the PECVD $SiO_xN_y$ Process for Anti-reflective Coating (ARC를 위한 PECVD $SiO_xN_y$ 공정에서 $N_2O$ 처리 및 cap 산화막의 영향)

  • Kim, Sang-Yong;Seo, Yong-Jin;Kim, Chang-Il;Chung, Hun-Sang;Lee, Woo-Sun;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.39-42
    • /
    • 2000
  • As gate dimensions continue to shrink below $0.2{\mu}m$, improving CD (Critical Dimension) control has become a major challenge during CMOS process development. Anti-Reflective Coatings are widely used to overcome high substrate reflectivity at Deep UV wavelengths by canceling out these reflections. In this study, we have investigated Batchtype system for PECVO SiOxNy as Anti-Reflective Coatings. The Singletype system was baseline and Batchtype system was new process. The test structure of Singletype is SiON $250{\AA}$ + Cap Oxide $50{\AA}$ and Batchtype is SiON $250{\AA}$ + Cap Oxide $50{\AA}$ or N2O plasma treatment. Inorganic chemical vapor deposition SiOxNy layer has been qualified for bottom ARC on Poly+WSix layer, But, this test was practiced on the actual device structure of TiN/Al-Cu/TiN/Ti stacks. A former day, in Batchtype chamber thin oxide thickness control was difficult. In this test, Batchtype system is consist of six deposition station, and demanded 6th station plasma treatment kits for N2O treatment or Cap Oxide after SiON $250{\AA}$. Good reflectivity can be obtained by Cap Oxide rather than N2O plasma treatment and both system of PECVD SiOxNy ARC have good electrical properties.

  • PDF

Feasibility Study of Mobius3D for Patient-Specific Quality Assurance in the Volumetric Modulated Arc Therapy

  • Lee, Chang Yeol;Kim, Woo Chul;Kim, Hun Jeong;Lee, Jeongshim;Huh, Hyun Do
    • Progress in Medical Physics
    • /
    • v.30 no.4
    • /
    • pp.120-127
    • /
    • 2019
  • Purpose: This study was designed to evaluate the dosimetric performance of Mobius3D by comparison with an aSi-based electronic portal imaging device (EPID) and Octavius 4D, which are conventionally used for patient-specific prescription dose verification. Methods: The study was conducted using nine patients who were treated by volumetric modulated arc therapy. To evaluate the feasibility of Mobius3D for prescription dose verification, we compared the QA results of Mobius3D to an aSi-based EPID and the Octavius 4D dose verification methods. The first was the comparison of the Mobius3D verification phantom dose, and the second was to gamma index analysis. Results: The percentage differences between the calculated point dose and measurements from a PTW31010 ion chamber were 1.6%±1.3%, 2.0%±0.8%, and 1.2%±1.2%, using collapsed cone convolution, an analytical anisotropic algorithm, and the AcurosXB algorithm respectively. The average difference was found to be 1.6%±0.3%. Additionally, in the case of using the PTW31014 ion chamber, the corresponding results were 2.0%±1.4%, 2.4%±2.1%, and 1.6%±2.5%, showing an average agreement within 2.0%±0.3%. Considering all the criteria, the Mobius3D result showed that the percentage dose difference from the EPID was within 0.46%±0.34% on average, and the percentage dose difference from Octavius 4D was within 3.14%±2.85% on average. Conclusions: We conclude that Mobius3D can be used interchangeably with phantom-based dosimetry systems, which are commonly used as patient-specific prescription dose verification tools, especially under the conditions of 3%/3 mm and 95% pass rate.

K-Ar Age of the Keumseongsan Volcanic Rocks and Mineralization in the Southeastern Part of Euiseong, Gyeongsangbuk-Do, Republic of Korea (경북·의성 동남부에 분포하는 금성산 화산암류의 K-Ar연대와 그주변의 광화시기)

  • Lee, Hyun Koo;Kim, Sang Jung;Yun, Hyesu;Choi, Wyi Chan;Song, Young Su;Itaya, Tetsumaru
    • Economic and Environmental Geology
    • /
    • v.26 no.4
    • /
    • pp.445-454
    • /
    • 1993
  • The Keumseongsan caldera is composed of the Cretaceous sedimentary rocks of the Gyeonesang Supergroup, volcanic rocks of the Yucheon Group and basic dykes. The Keumseongsan caldera is formed by subsidence of volcanic rocks, and arc fault developed late. Also, synistral strike-slip fault ($N60^{\circ}W$) developed. Volcanic rocks belong to subalkaline rocks and calcalkaline magma series. First tuffaceous breccia erupted before 71.4 Ma and cavity of magma chamber caused subsidence, which formed arc fault. Basaltic lava erupted at 71.4 Ma and residual fluids containing Fe, As, Pb, Zn and Cu metal elements built the Ohto deposits, which are dated to be 70.5 Ma based on K-Ar age for sericite. Tuffaceous breccia and tuff erupted between 70.5 and 67 Ma. When volcanic eruption became weakened, cavity in site of magma chamber brought subsidence. Rhyolite intruded and erupted at 67 Ma, and intrusive rhyolite intruded according to arc faults, also. Hydrothermal fluids containing Fe, As, Pb, Zn, Cu, Sb, Bi, Au and Ag formed the Tohyeon deposits. K-Ar age for sericite from the Tohyeon mine gives 66.0 Ma. Results of field exploration, geochemical analyses of volcanic rocks support mineralization possibility by volcanism. Especially, age of volcanism and mineralization are well in coincidence with results of K-Ar age dating. By these results, Ohto Cu mineralization is regarded to be associcated with basaltic rocks, while Tohyeon Cu mineralization with rhyolitic rocks.

  • PDF