• Title/Summary/Keyword: Applied Energy

Search Result 10,608, Processing Time 0.036 seconds

Shingled String for the High Performance Photovoltaic Module (고효율 태양광 모듈 제작을 위한 스트링 공정 최적화)

  • Jee, Hongsub;Moon, Daehan;Song, Jinho;Jeong, Chaehwan
    • Current Photovoltaic Research
    • /
    • v.6 no.4
    • /
    • pp.119-123
    • /
    • 2018
  • The High Performance Module With The Shingled String Has Several Advantages Such As The Larger Active Area, Higher Open-Circuit Voltage And Smaller Cell To Module (Ctm) Loss. To Obtain Increase Of Power In Pv Shingled Module, The Detailed Condition Of Various Parameters Related To Cutting And Bonding Process Were Investigated In This Study. We Searched The Optimized Cutting Conditions Of Laser Scan Speed, The Number Of Laser-Scribing And Also Bonding Conditions Of Electrically Conductive Adhesives (Eca) By Varying Amount Of Eca, Curing Time And Curing Temperature. The Shingled Pv Module Showed 25.4W of Maxmimum Power At 60 Rpm Of Dipensing Motor Speed, 30 Seconds Of Curing Time And $140^{\circ}C$ Of Curing Temperature, Respectively.

Improvement in Power of Shingled Strings by Re-work Process (Re-work 공정을 통한 슁글드 스트링의 출력 개선)

  • Song, Jinho;Jee, Hongsub;Moon, Daehan;Kim, Do-Heyong;Yang, O-Bong;Jeong, Chaehwan
    • Current Photovoltaic Research
    • /
    • v.7 no.2
    • /
    • pp.51-54
    • /
    • 2019
  • The high density module (HDM) has advantages for its larger active area and smaller current density. This new way of making a photovoltaic (PV) module method has benefit for increasing module power with the same installed area. Because HDM consisted with serially connected PV strings, loss of strings during the fabrication process can increase the overall production cost.1-2 This study investigates the rework conditions of the shingled strings with electrically conductive adhesives (ECA). By heating the electrically connected area of a fabricated string, cured area become soft and a string can be detached for the rework process. After rework process, a refabricated string showed 5~10% increased output power compared to before rework process and reached to the 90~95% output power compare to the undamaged strings.

Synthesis, Photophysical and Electrochemical Properties of Novel Conjugated Donor-Acceptor Molecules Based on Phenothiazine and Benzimidazole

  • Zhang, Xiao-Hang;Kim, Seon-Ho;Lee, In-Su;Gao, Chun-Ji;Yang, Sung-Ik;Ahn, Kwang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.8
    • /
    • pp.1389-1395
    • /
    • 2007
  • Two series of new organic fluorophores such as asymmetrical 3-(benzimidazol-2-yl)-10-hexylphenothiazine derivatives 1 and symmetrical 3,7-bis(benzimidazol-2-yl)-10-hexylphenothiazine derivatives 2 have been synthesized. Electronic absorption, fluorescence, and electrochemistry measurements reveal that the electron withdrawing benzimidazole subunit directly connected to the phenothiazine core facilitates the charge transfer characters which were also verified by the theoretical calculations. Various substituents on the benzimidazole moieties can allow a fine-tuning of the LUMO energy levels of the molecules without significantly affecting the HOMO energy levels. The method provides a new route for designing ambipolar molecules whose energy levels are well-matched with the Fermi levels of the electrodes to facilitate the electron or hole injection/transfer in OLED devices.

A Novel Hybrid Supercapacitor Using a Graphite Cathode and a Niobium(V) Oxide Anode

  • Park, Gum-Jae;Kalpana, D.;Thapa, Arjun Kumar;Nakamura, Hiroyoshi;Lee, Yun-Sung;Yoshio, Masaki
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.4
    • /
    • pp.817-820
    • /
    • 2009
  • To meet the high current load requirement from the high energy density realized by metal oxide and high power density graphite, we propose a novel hybrid supercapacitor consisting of Nb2O5 and KS6 graphite in 1.0 M LiPF6-EC:DEC (1:2). This new system exhibits a sloping voltage profile from 2.7 to 3.5 V during charging and presents a high operating voltage plateau between 1.5 and 3.5 V during discharging. The cell was tested at a current density of 100 mA/g with a cut-off voltage between 3.0 and 1.0 V. This novel energy storage system delivers the highest initial discharge capacity of 55 mAh/g and exhibits a good cycle performance.

Economic Analysis of Geothermal Energy Facilities Applied to Public Buildings (공공 건축물 지열에너지설비 적용에 따른 경제성 분석)

  • Jang, Young Jun;Kim, Sangyong;Shin, Yoonseok;Kim, Gwang-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.5
    • /
    • pp.423-432
    • /
    • 2014
  • The aim of this study to propose an efficient method in selecting the type of new and renewable energy applied in at the planning phase of buildings. This study applied geothermal energy facilities with high adaptability to buildings. This study considered the energy reduction and reduced cost by comparing the values with the energy consumption before applying of geothermal energy facilities. In order to propose more reliable criteria of economic evaluation, maintenance costs reflecting the replacement cycles and initial construction costs by drawings and specifications for installation facilities for practical geothermal energy based on construction statement for life-cycle cost analysis. The results will help to effectively select economic types of facilities for new and renewable energy of the planning phase of buildings.

An Empirical Analysis of Building Energy Consumption Considering Building and Local Factors in Seoul (건물과 지역요인을 고려한 서울시 건물에너지 소비 실증분석)

  • Lee, Sujin;Kim, Kijung;Lee, Seungil
    • Journal of Korea Planning Association
    • /
    • v.54 no.5
    • /
    • pp.129-138
    • /
    • 2019
  • This study aims to empirically examine the relationship between building energy consumption and building and local factors in Seoul. Building energy issue is an important topic for low carbon and eco-friendly city development. Building physical, socio-economic and environmental factors effect to increasing or decreasing energy consumption. However, there are different characteristic in each area, and this kind of variable has a hierarchical structure. The multi-level model was used to consider the hierarchical structure of the variables. In this study, a multi-level model was applied to confirm the difference between areas. Spatial area is Seoul, Korea and the temporal scope is August, summer season. As the result, in Model 1 (Null Model), ICC is 0.817. This shows that the energy consumption differs by 8.174% due to factors at the Dong level. Model 2 (Random Intercept Model) suggests that building's physical factors and Average age, Household size and Land price in Dong level have significant effects on Building energy consumption. In Model 3 (Random Coefficient Model), random effect variables have intercepts and slopes to vary across groups. This study provides a perspective for policy makers that the building energy reduction policies to be applied for buildings should be differently applied on area. Furthermore, not only physical factors but also socio-economic and environmental factors are important when making energy reduction policy.

A Study on the Energy Saving Methods of a House by Passive System (건축적 수법을 통한 주택의 에너지 절약 방안에 관한 연구)

  • 김용식
    • Journal of the Korean housing association
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2002
  • Recently, the energy consumption has been sharply increased and the environmental pollution has been serious, resulted in increased use of fossil fuel. These facts are applied to most fields, and are especially important issues in the field of architecture. The energy consumption rate of building is about 30% of all energy consumption, and the rate of residential is about 20% of the rate of building and is increasing gradually. The purpose of this article is firstly to analyse an actual energy consumption rate of model building and compare it with alternative methods, which are applied passive system to, and secondly to suggest an optimal passive method for saving energy. The conclusion of this study is as follows; 1) As compared with the existing house on actual energy consumption rate, 6% in changing orientation to a south, 9% in using double low-e glazing and 23% in shading is decreased. 2) The change of insulation from 50 to 100mm did not show dramatical difference in energy consumption rate. 3) As changed indoor temperature at 2$0^{\circ}C$ in winter and 27$^{\circ}C$ in summer, the rate shows a reduction of 14% compared with the existing condition.

The Analysis of Life Cycle Cost and Cooling Water Circulating Pump Energy Saving According to Variable Speed Pressure Differential Setpoint Control Strategy

  • Kim, Seo-Hoon;Kim, Jong-Hun;Jang, Cheol-Yong;Song, Kyoo-dong
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.37-43
    • /
    • 2015
  • Purpose : The study applied control strategy to reduce through optimal control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. The study has the purpose to review validity of control on variable speed as ESMs(Energy Saving Measures) and establish the control technology on variable speed pump. The study performed reduction analysis of building energy and economic evaluation of pump through energy effectiveness control strategy of HVAC system. Method: The study sought possible reduction through energy control strategy which can provide proper flow fitting to building load by applying control on variable speed pump. The study applied control strategy to reduce through pressure differential set-point control and operation of pump by applying control on variable speed to the circulation pump of HVAC system in the office building. Result : The results showed that about 16-35% of pump energy could be saved by using these optimal control strategies. In the result of analysis on 10 years life cycle cost of analysis on payback period of initial investment pump, variable speed pump control showed 5.1 years.

An Analysis of Heating Energy Performance in Housings of ICF Method with Passive Design Applied (패시브 디자인을 적용한 ICF공법 주택의 난방에너지 성능 분석)

  • Kim, Jun-Hui;Lee, Tae-Gu
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.33-40
    • /
    • 2013
  • The world population is consuming more than 1/3 of the total energy for heating housings. Particularly in our country, 21% of the consumption energy is occupied by building section. Therefore, it is necessary to increase the energy efficiency in buildings, thus promoting a comfortable residential environment while minimizing energy consumption. Accordingly, this study presents considerations for implementing high-insulated and airtight passive houses. This study selected four houses with passive house design applied, performed building energy performance through PHPP2007, a German passive house design simulation program, and compared the building-specific heat loss and heat gain. As a result, the most vulnerable part to heat loss was turned out to be a window and the heat loss was caused by outer wall, roof, and ventilation. Accordingly, for the implementation of passive house, it is necessary to make a careful plan and airtight construction that are complementary to various parts through the energy performance analysis started from the design phase.

The Analysis about the Status of Biomass Energy in CDM Market (CDM에서의 바이오매스 에너지 활용현황 및 전망)

  • Myung, So-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.658-661
    • /
    • 2007
  • It was investigated on this paper that the status of biomass energy utilization in the registered CDM projects. The ratio of the case including the energy recovery among the registered biomass CDM projects is just about 57%. Direct thermal conversion technology is the most commonly applied for biomass energy recovery projects. Through the comparative study with world renewable energy outlook, the contribution of CDM to biomass energy supply in the world is not considerable yet.

  • PDF