So, Kyeung Jin;Lee, Mi Hyun;Ma, Sang Hyeok;Kim, Byung Chyeol;Yang, Jai Myung
Pediatric Infection and Vaccine
/
v.11
no.1
/
pp.59-72
/
2004
Purpose : Rotaviruses are the major cause of gastroenteritis in infants and young children worldwide. It is important to get the epidemiologic data of rotavirus genotype for the application of rotavirus vaccine. So we tried to investigate the distribution of rotavirus genotypes with RT-PCR. Methods : A total of 120 rotavirus latex agglutinin test positive stool samples were collected continually from 120 children from Sep. 2000 to Apr. 2001. Rotavirus P(VP4), G (VP7) genotypes were determined by RT-PCR. Results : The genotype was identified in 116 stool samples of total 120 samples(96%). The incidence of G genotype was as follow; G1 17(14.2%), G2 74(61.7%), G4 1(0.8%), G9 1(0.8%). There were four cases of multiple genotypes; G1/G2, G1/G4, G1/G9, G8/G9 and genotype of G3, G8 were not found. Twenty three(19.2%) samples were nontypeable. The incidence of P was as follow; P[4] 77(64.2%), P[6] 22(18.3%), P4/P6 12(10%), P[4]/P[8] 1(0.8%) p[8] 1(0.8%). Seven(5.9%) samples were nontypeable. Conclusion : Various combinations of G and P genotypes were observed. Most rotavirus strains were P[4]G2 62(51.74%), followed by P[6]G2 7(5.8%), and P[6]G1 7(5.8%), P[4/P[6] G1 4(3%), P[4]/P[6]G2 4(3%), P[4]G1 3(2.5%), P[8]G2 1(0.8%), P[4]G4 1(0.8%) in Kyoungsangnamdo, Korea during 2000~2001.
Kim, Eng-Chan;Kim, Ki-Hong;Park, Cheol-Soo;Lee, Sun-Yeob;Yoo, Heung-Joon;Cho, Jae-Hwan;Jang, Hyun-Cheol;Kim, Bo-Hui;Han, Man-Seok
Journal of the Korean Society of Radiology
/
v.5
no.1
/
pp.37-49
/
2011
To examine the possible changes in the SNRs, CNRs, and ADC values for lumbar spines with metastasis based on the DW images before and after contrast agent injection taken from metastatic spinal cancer patients using a 1.5 T MR machine. The quantitative analysis revealed that in case of spinal cancer subjects, both SNRs and CNRs at all of those assessed locations significantly increased on the DWI after contrast agent injection compared to before, while on the ADC map images, SNRs significantly decreased. On the other hand, significantly decreased ADC values at all the assessed locations were found on the ADC map images. With reference to the normal group, significantly increased SNRs were found at all of the assessed locations on the DWI image after injection compared to before, while significantly decreased SNRs were found on the ADC map images. Also, significantly decreased ADC values at all the assessed locations were found on the ADC map images. For the qualitative analysis, after contrast agent injection, significantly increased signal intensities were found at the locations with spinal cancer on the DWI. In contrast, significantly decreased signal intensities were found on the ADC map images. The implication from the results showing that SNR and CNR significantly increased while ADC value significantly decreased at, above, and below the location of metastatic spinal cancer on DWI after contrast agent injection is that DWI obtained after contrast agent injection can be made available for wider application to vertebral disorders.
Background: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of experimental studies shows that pulsatile perfusions are more useful than non-pulsatile counterparts in many areas, such as homodynamic, metabolism, organ functions, and micro-circulation. Yet, many concerns relating to pulsatile cardiopulmonary machines, such as high internal circuit pressure and blood cell damage, have long hindered the development of pulsatile cardiopulmonary machines. Against this backdrop, this study focuses on the safety and effectiveness of the pulsatile cardiopulmonary machines developed by a domestic research lab. Material and Method: The dual-pulsatile cardiopulmonary bypass experiment with total extracorporeal circulation was conducted on six calves, Extracorporeal circulation was provided between superior/inferior vena cava and aorta. The membrane oxygenator, which was placed between the left and right pumps, was used for blood oxygenation. Circulation took four hours. Arterial blood gas analysis and blood tests were also conducted. Plasma hemoglobin levels were calculated, while pulse pressure and internal circuit pressure were carefully observed. Measurement was taken five times; once before the operation of the cardiopulmonary bypass, and after its operation it was taken every hour for four hours. Result: Through the arterial blood gas analysis, PCO2 and pH remained within normal levels. PO2 in arterial blood showed enough oxygenation of over 100 mmHg. The level of plasma hemoglobin, which had total cardiopulmonary circulation, steadily increased to 15.87 $\pm$ 5.63 after four hours passed, but remained below 20 mg/㎗. There was no obvious abnormal findings in blood test. Systolic blood pressure which was at 97.5$\pm$5.7 mmHg during the pre-circulation contraction period, was maintained over 100 mmHg as time passed. Moreover, diastolic blood pressure was 72.2 $\pm$ 7.7 mmHg during the expansion period and well kept at the appropriate level with time passing by. Average blood pressure which was 83$\pm$9.2 mmHg before circulation, increased as time passed, while pump flow was maintained over 3.3 L/min. Blood pressure fluctuation during total extracorporeal circulation showed a similar level of arterial blood pressure of pre-circulation heart. Conclusion: In the experiment mentioned above, pulsatile cardiopulmonary machines using the doual-pulsatile structure provided effective pulsatile blood flow with little damage in blood cells, showing excellence in the aspects of hematology and hemodynamic. Therefore, it is expected that the pulsatile cardiopulmonary machine, if it becomes a standard cardiopulmonary machine in all heart operations, will provide stable blood flow to end-organs.
Although a variety of synthetic vascular grafts are available in modern vascular surgery, no ideal prosthesis ha,4 yet been developed. Small-caliber vascular grafts with low flow, as used in the lower extremity, continue to become thrombosed at unacceptable rates. We have developed and evaluated the new antithrombogenic blood contacting surfaces in canine model. Material and Method: Two now antithrombogenic blood contacting surfaces(Polyvinylalcohol -Polyurethane(PVA-PU) blend and natural Graphite-polyurethane(G-PU) blend) have been developed and evaluated in canine model, using vascular grafts and patches. The luminal surfaces of the test vascular grafts(5 mm ID) were fabricated by dipping a glass rod in PVA-PU blend solution(50 % PVA) using phase separation method. Mongrel dogs of either sex weighing 18-22 kg were anesthetized by endotracheal intubation using halothane and their lungs were ventilated with a volume-cycled ventilator, Maintenance anesthesia with 0.5-1.0% halothane and supplemental oxygen was used. Two pairs were used for comparison in the bilateral femoral arteries for both vascular grafts(PVA-PU vs. PU) and vascular patches(G-PU vs. PU). Bilateral groin incisions were made and the arteries were exposed and clamped. After an excision of 1 cm of the artery between clamps, a grail of 2.5 cm in length was implanted end-to-end using 6-0 polypropylene suture. The vascular patch was implanted as a form of on-lay patch. Animals were sacrificed at 1, 2, 4, 6, 8 and 16 weeks for vascular grafts and 1, 2. 4 and 6 weeks for vascular patches. Result The vascular grafts of PVA-PU blends showed patent lumina in the 2 and 16 weeks animals, while those of PU showed a patent lumen in 2 weeks animal. PVA-PU graft of 16 weeks showed a fairly clean luminal surface. A light microscopic finding of this graft demonstrated good tissue infiltration through porosity, The animals with vascular patches showed patent arteries in both groups except 2 weeks animal. Scanning electron microscopy of the luminal surfaces of G-PU patches in 4 and 6 weeks animals showed endothelial cell covering with microvilli. PU patches showed qualitatively less endothelial cell covering. Conclusion: In conclusion, PVA-PU and G-PU blends can be a promising blood contacting surfaces for application in a synthetic vascualr graft. However, further animal study is needed to determine the real long-term effects of these methods of surface modifications.
Proceedings of the Korea Society of Poultry Science Conference
/
2003.07b
/
pp.67-88
/
2003
The consumption of poultry meat (chicken and turkey) grew the most during the past few decades due to several contributing factors such as low price. product research and development. favorable meat characteristics, responsive to consumer needs, vertical integration and industry consolidation, new processing equipments and technology, and aggressive marketing. The major processing technologies developed and used in chicken processing include forming/restructuring, tumbling, curing, smoking, massaging, injection, marination, emulsifying, breading, battering, shredding, dicing, and individual quick freezing. These processing technologies were applied to various parts of chicken including whole carcass. Product developments using breast, thigh, and mechanically separated chicken meat greatly increased the utilization of poultry meat. Chicken breast became the symbol of healthy food, which made chicken meat as the most frequent menu items in restaurants. However, the use of and product development for dark meat, which includes thigh, drum, and chicken wings were rather limited due to comparatively high fat content in dark meat. Majority of chicken are currently sold as further processed ready-to-cook or ready-to-eat forms. Major quality issues in chicken meat include pink color problems in uncured cooked breast, lipid oxidation and off-flavor, tenderness PSE breast, and food safety. Research and development to ensure the safety and quality of raw and cooked chicken meat using new processing technologies will be the major issues in the future as they are now. Especially, the application of irradiation in raw and cooked chicken meat products will be increased dramatically within next 5 years. The market share of ready-to-eat cooked meat products will be increased. More portion controlled finished products, dark meat products, and organic and ethnic products with various packaging approaches will also be introduced.
This study presents an application of hydro-mechanical coupled Particle Flow Code 3D (PFC3D) to simulation of fluid injection induced fault slip experiment conducted in Mont Terri Switzerland as a part of a task in an international research project DECOVALEX-2019. We also aimed as identifying the current limitations of the modelling method and issues for further development. A fluid flow algorithm was developed and implemented in a 3D pore-pipe network model in a 3D bonded particle assembly using PFC3D v5, and was applied to Mont Terri Step 2 minor fault activation experiment. The simulated results showed that the injected fluid migrates through the permeable fault zone and induces fault deformation, demonstrating a full hydro-mechanical coupled behavior. The simulated results were, however, partially matching with the field measurement. The simulated pressure build-up at the monitoring location showed linear and progressive increase, whereas the field measurement showed an abrupt increase associated with the fault slip We conclude that such difference between the modelling and the field test is due to the structure of the fault in the model which was represented as a combination of damage zone and core fractures. The modelled fault is likely larger in size than the real fault in Mont Terri site. Therefore, the modelled fault allows several path ways of fluid flow from the injection location to the pressure monitoring location, leading to smooth pressure build-up at the monitoring location while the injection pressure increases, and an early start of pressure decay even before the injection pressure reaches the maximum. We also conclude that the clay filling in the real fault could have acted as a fluid barrier which may have resulted in formation of fluid over-pressurization locally in the fault. Unlike the pressure result, the simulated fault deformations were matching with the field measurements. A better way of modelling a heterogeneous clay-filled fault structure with a narrow zone should be studied further to improve the applicability of the modelling method to fluid injection induced fault activation.
The purpose of this study were to analyze the clinical correlation between the thyroid autoimmune antibodies (anti-TPO Ab, anti-TG Ab, and TSH) and the maximum standardized uptake value ($SUV_{max}$) base on the Hashimoto's thyroiditis and the Graves' disease in diffusely $^{18}F-FDG$ uptake of the thyroid gland to the PET/CT image. To achieve this, we was performed the PET/CT examination for the 1,097 subjects from May 2010 to April 2013 in the health screening, and was detected the diffused FDG thyroid uptake, and was additionally performed the thyroid function test (TFT) and the ultrasound (US). As a results, the autoimmune thyroid disease with the diffused FDG thyroid uptake were discovered 39 patients (3.9%), of this, the Hashimoto's thyroiditis was 43.6% and the Graves' disease was 23.1%. Hashimoto's thyroiditis was shown the positive reaction of high titer between the anti-TPO Ab and the anti-TG Ab level, and the correlation coefficient between the $SUV_{max}$ and the anti-TPO Ab was a statistically significant (r>04, p<0.05). Also, Graves' disease was shown the positive reaction of high titer most of the thyroid autoimmune antibodies, and the correlation coefficient between the $SUV_{max}$ and the anti-TPO Ab was a statistically significant (r>05, p<0.01). Therefor, when have a high standard of the $SUV_{max}$ due to the diffusely $^{18}F-FDG$ uptake of the thyroid gland, Hashimoto's thyroiditis and Graves' disease were proportionally increased the anti-TPO Ab and TSH level, respectively. The correlation coefficient between the $SUV_{max}$ and the thyroid autoimmune antibodies will be the most influential criterion that was a standard of judgment for the epihpenomenon of the autoimmune thyroid disease, and it will be available for the clinical application.
Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
The Korean Journal of Nuclear Medicine Technology
/
v.18
no.1
/
pp.98-103
/
2014
Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.
Exogeneous application of pokeweed antiviral protein (PAP), a ribosomal-inacivating protein in the cell wall of Phytolacca americana (pokeweed) protects heterologous plants from viral and fungal infection. A cDNA clone of PAP introduced into Scrophularia buergeriana Miquel by thransformation with Agrobacterium tumefaciences. For plant transformation, explants were precultured on shoot induction medium without kanamycin for 2-5 day, and then they were cocultured with Agrobacterium for 10 minutes. The explants were placed on co culture medium in dark condition, $28^{\circ}C$ for 2days. After explants were washed in MS liquid medium, they were transferred into selection medium including kanamycin 50mg/L (MS salts+1mg/ l BAP+2mg/ l TDZ+0,2mg/ l NAA+MS vitamin+3% sucrose+0.8% agar, pH5.8). From PCR analysis, NPT II band was confirmed in transgenic plant genome and showed resistance against fungi in antifungal activity test. Micro assay to which protein extracted from transgenic line were added, revealed hyphae growth inhibition and no spore germination at high concentration. The characteristics of inhibited hyphae was represented transparent and thin. Expression of PAP in transgenic plants offers the possibility of developing resistance to viral and fungal infection.
Journal of the Korea institute for structural maintenance and inspection
/
v.18
no.5
/
pp.1-8
/
2014
Structures requiring chemical resistance are usually coated with surface protecting agents, but the cost for maintenance and re-construction is incurred due to the low durability. Therefore, in this study, sulfur was polymerized and the performance was examined so that it could be used as the concrete surface protecting agents for structures requiring chemical resistance. The evaluation results indicated that for the spray of the sulfur polymer surface coating agents, the application of the gravity type was appropriate; and for the number of coating times, about 3 cycle spray gave the best results. For the surface condition of the concrete to be coated with the surface protecting agents, outstanding quality was obtained above room temperature ($20{\sim}30^{\circ}C$), and the bond strength increased as the temperature increased. The evaluation results of the strength characteristics depending on the filler content of the surface protecting agents indicated that about 20~40% filler mixing contributed to the strength improvement as it reduced the shrinkage of the sulfur polymer. Also, the mixing of silica showed larger increase in the bond strength than the mixing of fly ash, and the most outstanding bond strength characteristics could be obtained by the mixing of both silica and fly ash. In the case of the chemical resistance, the strength reduction was minimized and outstanding chemical resistance was obtained when the fly ash and silica were substituted by 20%, respectively. The performance evaluation of the chloride ion penetration indicated that for the specimens coated with the sulfur polymer surface protecting agents, the chloride ion penetration resistance increased by 29~48% compared to the specimen without the coating of the surface protecting agent. The examination of the coating condition of the surface protecting agents, compressive strength, bond strength, chemical resistance, and salt damage resistance indicated that in the range of this study, the optimal level was when the silica and fly ash were substituted by 20%, respectively, as the filler for the sulfur polymer.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.