• Title/Summary/Keyword: Applicability test

Search Result 1,869, Processing Time 0.033 seconds

Full Scale Load Tests on Reinforced Slope Structure (사면보강구조물에 대한 실물재하시험과 평가)

  • Kwon, Young-Ho;Park, Shin-Young;Lee, Seung-Hyun;Kang, In-Kyu;Ki, Min-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.241-255
    • /
    • 2006
  • Owing to a landslide or embankment damage be caused by a localized torrential downpour and heavy snowfall resulted from recent abnormal climate, a slope stability is very important. This study is investigate a general slope reinforcement method and applicability improvement of soil nailing method utilized prototype loading test for the facing stiffness effect confirmation. A prototype loading test supplements general slope stability study by numerical analysis or laboratory test with a resonable analysis of slope structure.

  • PDF

Super-cooled State Cloud Generation System Development for T-50 Supersonic Jet Trainer Icing Test (T-50 고등훈련기 빙결시험을 위한 과냉각구름 생성시스템 개발)

  • Lee, Cheol;Jeon, Cheol-Woo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.6
    • /
    • pp.580-586
    • /
    • 2008
  • Icing cloud generation system was developed to perform the in-flight icing simulation test for T-50 Supersonic Jet Trainer on the ground. The developed system successfully generated the almost natural icing cloud in the super-cooled state (liquid state) below freezing point and with the required LWC (Liquid Water Content). For full-scale aircraft icing test, an icing scaling method was adopted due to the limitation of wind generation speed with open-circuit type blower and its applicability was experimentally verified. Under the required in-flight icing condition based on the icing scaling method, T-50 aircraft subsystems were successfully operated and functionally checked.

A Study on the Use of Fresh Root-chips in Slope Revegetation Works (비탈면 녹화에서 임목폐기물의 활용에 관한 연구)

  • Kim, Nam-Choon;Lee, Jung-Ho;Lee, Tae-Ok;Heo, Young-Jin
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.4
    • /
    • pp.119-128
    • /
    • 2008
  • In this study, we attempted to seek out the ways to recycle fresh root-chips in the slope revegetation works by breaking tree root wastes occurring during the construction works, also to review the applicability of fresh root-chips as the soil media in slope revegetation works. For this purpose, we organized test units in order to investigate on-site applicability of fresh root-chips (broken chips). In order to examine the desirable ration of combining fresh root-chips with the hydroseeding soil media on the cutting slopes, we organized test units depending on the amount of combination. The following is the main experimental results. 1. At first, we analyzed properties of hrdro-seeding soil media and soil of the experimental sites. The overall results demonstrate that all the test units show proper range for vegetation. 2. We believe that the physical properties of soils in the earlier phase of restoration works on the sloped sites are not greatly affected by the fact whether broken chips exist or not. However, as time elapses, broken chips needs to be investigated further on what kind of impact they have on the soil condition. 3. More species are found in the test unit combining broken chips and we believe that it will contribute to blossoming of green plants and ecological succession of neighboring plants. 4. We performed experiment on possibility for fresh root-chips as substitutes for the hydro-seeding soil-media. In the test unit that combines fresh root-chips, its mixture ratio tends to exceed that of the test unit that does not combine fresh root-chips by 5 %. In case of the Thick-Layer-Soil-Media Hydroseeding works, the mixture ratio of the test unit that combines fresh root-chips after 16 weeks exceeds that of the test unit that does not combine fresh root-chips by 75%. 5. From the result of our experiment, it is obvious that the ratio of mixture and the number of emerging species are higher for the test unit combining fresh root-chips than the test unit that does not combine them. In other words, we can replace the hydro-seeding-soil-media with some Fresh root-chips without affecting the physical property of soil.

A Hybrid Cloud Testing System Based on Virtual Machines and Networks

  • Chen, Jing;Yan, Honghua;Wang, Chunxiao;Liu, Xuyan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.4
    • /
    • pp.1520-1542
    • /
    • 2020
  • Traditional software testing typically uses many physical resources to manually build various test environments, resulting in high resource costs and long test time due to limited resources, especially for small enterprises. Cloud computing can provide sufficient low-cost virtual resources to alleviate these problems through the virtualization of physical resources. However, the provision of various test environments and services for implementing software testing rapidly and conveniently based on cloud computing is challenging. This paper proposes a multilayer cloud testing model based on cloud computing and implements a hybrid cloud testing system based on virtual machines (VMs) and networks. This system realizes the automatic and rapid creation of test environments and the remote use of test tools and test services. We conduct experiments on this system and evaluate its applicability in terms of the VM provision time, VM performance and virtual network performance. The experimental results demonstrate that the performance of the VMs and virtual networks is satisfactory and that this system can improve the test efficiency and reduce test costs through rapid virtual resource provision and convenient test services.

Development of Integrated Operating Program for Inshore Test Miner and its Simulator (근해역 시험집광기용 통합운용 프로그램 및 시뮬레이터 개발)

  • Lee, Do-Kyoung;Yoon, Suk-Min;Park, Soung-Jea;Yeu, Tae-Kyeong;Hong, Sup;Kim, Hak-Kyeong;Kim, Sang-Bong
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.78-84
    • /
    • 2009
  • This paper presents development results of integrated operating program and its simulator for an inshore test miner. The inshore test miner drives on the seabed and collects manganese nodules. For operating the test miner, integrated operating program (IOP) is needed for remote control and monitor of the miner in real-time. However, it is hard to develop the practical IOP for the test miner system, because the system is big, expensive, and unique. So a simulator was developed as a test substitute in order to save time and to reduce cost. Using test results of the simulator, the IOP of the test miner was developed. The developed IOP consists of remote program, host program, monitoring program and database program. The operating program was developed using PXI and Labview of NI. The experimental results are presented to show the applicability of the developed program.

Investigation on Intermittent Life Testing Program for IGBT

  • Cheng, Yu;Fu, Guicui;Jiang, Maogong;Xue, Peng
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.811-820
    • /
    • 2017
  • The reliability issue of IGBT is a concern for researchers given the critical role the device plays in the safety of operations of the converter system. The reliability of power devices can be estimated from the intermittent life test, which aims to simulate typical applications in power electronics in an accelerated manner to obtain lifetime data. However, the test is time-consuming, as testing conditions are not well considered and only rough provisions have been made in the current standards. Acceleration of the test by changing critical test conditions is controversial due to the activation of unexpected failure mechanisms. Therefore, full investigations were conducted on critical test conditions of intermittent life test. A design optimization process for IGBT intermittent life testing program was developed to save on test times without imposing additional failure mechanisms. The applicability of the process has been supported by a number of tests and failure analysis of the test results. The process proposed in this paper can guide the test process for other power semiconductors.

Estimation of Undrained Shear Strength of Very Soft Clay with the Slump Test (슬럼프 실험에 의한 초연약점토의 비배수전단강도 산정)

  • Noh, Tae-Kil;Lee, Song
    • Journal of the Korean Geotechnical Society
    • /
    • v.25 no.2
    • /
    • pp.17-24
    • /
    • 2009
  • Undrained shear strength is estimated from laboratory tests generally, but the very soft or fluid material is generally incompatible with the test setup. In-situ methods require test to be accomplished at discrete time intervals, which does not provide a method to predict strength increment as a function of time for an ongoing project. Therefore, correlation between slump test value and undrained shear strength was derived through the regression analysis of slump test and laboratory vane shear test results. For the reliability of derived correlation equation statistical analysis using the t-distribution was performed and the comparison between the results of in-situ test and laboratory experiments demonstrated the applicability of the derived correlation.

Applicability of Pulse Tests to Estimate Transmissivity in Crystalline Rock (결정질 암반의 투수량계수 도출을 위한 펄스시험의 적용성 연구)

  • Park, Kyung-Woo;Park, Byeong-Hak;Ko, Nak-Youl;Ji, Sung-Hoon
    • The Journal of Engineering Geology
    • /
    • v.30 no.3
    • /
    • pp.223-235
    • /
    • 2020
  • In this study, pulse tests were undertaken at an underground research facility, as part of in-situ hydraulic tests, to derive the hydrogeological characteristics of crystalline rock. The applicability of pulse tests for estimating the transmissivity of a fractured rock mass was evaluated by comparing the results to those from a slug test. Results from the pulse and slug tests were very similar for the test section, with both tests indicating low transmissivity. A slight difference between the results of pulse and slug tests, however, was observed in the section with the transmissivity larger than 1 × 10-8 ㎡/s, which is likely due to the difference in the radii of influence of the tests. Furthermore, when the pulse test was conducted in permeable zones where transmissivity was larger than 1 × 10-7 ㎡/s, it was difficult to produce accurate results. This lack of accuracy was due to the rapid recovery of the hydraulic head in these permeable test zones. When performing pulse tests, it was important to accurately measure the pressure when valves were opened and closed in order to apply the head change in the test section. Although it is difficult to derive the hydrogeological characteristics from pulse tests in areas with high permeability, these tests can be used as an economical test method for identifying hydrogeological characteristics in a relatively short time, especially when deriving the transmissivity of rocks with low permeability.

Evaluation of Applicability of Cable Force Monitoring System of Cable-stayed Bridge by Field Loading Test (재하시험을 통한 사장교의 케이블 장력 모니터링 시스템의 적용성 평가)

  • Kim, Jeong-Hoon;Song, Jae-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.13 no.1 s.53
    • /
    • pp.205-213
    • /
    • 2009
  • This study was planned to develop monitoring system of cable force to resolve cable force of cable-stayed bridge efficiently in a long-term plan. In the proposed monitoring system, firstly data are sampled from real-time acceleration record, secondly these sampled data are frequency analyzed by using the FFT(Fast Fourier Transform) algorism and lastly the analyzed results are averaged and generalized. For evaluating the applicability of this monitoring system, field loading test has performed in real cable-stayed bridge. In comparison with cable force by field manual calculation and cable force of monitoring system by semi-automatic calculation, the difference of calculated cable forces has within 1% error range and it is acceptable range. Additionally within negligible 5% error range of difference has occur between field manual calculation and monitoring system by automatic calculation. so monitoring system in this study has been verified to be reliable.

The Analysis of Shaft Deformation for Evaluating the Bearing Capacity of IGM Sosketed Drilled Shaft (IGM에 근입된 말뚝의 지지력 해석을 위한 기준침하량 결정방법 제안)

  • Chun, Byung-Sik;Kim, Won-Cheul;Seo, Deok-Dong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.3
    • /
    • pp.17-30
    • /
    • 2004
  • In this study, a new formula of settlement at the head of IGM was suggested and the applicability of suggested formula was verified with field test results. This suggested formula was the function of the settlement at the shaft head and the elastic compression of shaft. The applicability of suggested formula was verified with the result of in-situ load test. Also, the bearing capacity of drilled shaft with the IGM's theory was compared with those of classical theories. The results showed that classical method showed smaller values of bearing capacity than those of field load test data. The results of analysis also showed that the suggested formula and IGM's theory were applicable for the estimation of bearing capacity with the increase of shaft settlement. Especially, settlement correction factor($k_m$), which reflects ground condition and load transfer characteristics, increases as the applying load and shaft deformation increase. This suggested formula was applicable for medium density or higher density of soil condition and $k_m=1$ means yielding load for firm soil condition.

  • PDF