• Title/Summary/Keyword: Apparent power

검색결과 273건 처리시간 0.032초

기하대수에 의한 비정현파 다선식 전력계통에서의 피상전력의 표현 (Representation of Apparent Power of Non-sinusoidal Multi-line Power System Using Geometric Algebra)

  • 전성즙
    • 전기학회논문지
    • /
    • 제58권10호
    • /
    • pp.2064-2070
    • /
    • 2009
  • According to recent researches, apparent power in a non-sinusoidal single phase system can be represented with geometric algebra. In this paper, the geometric algebra is applied to apparent power defined in a multi-line system having transmission lines with frequency-dependency under non-sinusoidal conditions.

Geometric algebra에 의한 비정현파 다선식 전력계통에서의 피상전력 표현 (Representation of Apparent Power of Non-sinusoidal Multi-line Power System Using Geometric Algebra)

  • 전성즙
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1921_1922
    • /
    • 2009
  • According to recent researches, apparent power in non-sinusoidal single phase system can be represented with geometric algebra. In this paper, the geometric algebra is applied to apparent power defined in a multi-line system having transmission lines with frequency-dependent resistances under non-sinusoidal conditions.

  • PDF

인체 요추해면골의 배류계수, 겉보기밀도, 공극비 사이의 상관관계에 관한 연구 (Correlation Among Permeability, Apparent Density, And Porosity of Human Lumbar Vertebral Trabecular Bone)

  • 홍정화;강신일
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권4호
    • /
    • pp.333-338
    • /
    • 1997
  • Abnormal intraosseous flow and pressure in trabecular bone could cause various pathological conditions such as osteonecrosis and osteoarthritis. Characteristics of intraosseous fluid flow and pressure generation in porous trabecular bone can be significantly affected by the permeability. Factors which determine the permeability could be the porosity and apparent density of trabecular bone. However, there is little data on the permeability and the relationship among the permeability. porosity, and apparent density of trabecular bone. In this study. the permeability. porosity, and apparent density of human lumbar vertebral trabecular bone were experimentally measured. Also, a power relationship among the permeability, porosity, and apparent density was investigated to understand effects of the porosity and apparent density variations on the permeability of trabecular bone based on Kozeny-Carman equation. A near linear relationship between intraosseous fluid flow and time indicated that the fluid phase flowed through the pores in trabecular bone is governed by the permeability. The permeability of trybecular bone was found to have a significant power relationship with the porosity and apparent density (r: 0.84 and $\textit{p}$< 0.0005). The power relationship could be useful to determine the permeability of trybecular bone after measuring the apparent density and porosity.

  • PDF

A Fast Algorithm of the Apparent Factor Calculation for Distance Relay Setting without Fault Analysis

  • Jo, Yong-Hwan;Xiang, Ling;Choi, Myeon-Song;Park, Ji-Seung;Lim, Seong-Il;Kim, Sang-Tae;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.64-69
    • /
    • 2013
  • For power system protection, the distance relay settings are important. Apparent factor is a necessary parameter in distance relay settings. Apparent factors have to be calculated when setting the distance relays and doing the resetting in case of configuration change in power system. The problem is that the current method to calculate apparent factor requires tools and plenty of time to do fault analysis and this method is complex especially in case of configuration change. Therefore this paper proposes a fast algorithm to calculate apparent factor without the fault analysis. Test results prove that this algorithm is simple and accurate by simulation.

TV 대기모드 효율기준 개발을 위한 대기전력 실태 분석 (Analysis of TV Standby Power for Development of Energy Efficiency Standard)

  • 김익표;노경수
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.18-26
    • /
    • 2012
  • Recently, there have been suggestions that power factor should be considered to increase the efficiency of electric power supply when evaluating the performance of the electric appliances in standby mode and the related studies have been conducted to improve the efficiency standard of standby power. But, they lack the analysis of the standby power characteristics with the changes of power factor. This study is conducted to analyze the standby power characteristics of TV which is a typical home appliance and reaches a conclusion that the apparent power can be a more reasonable index which reflects the efficiency of electric power supply. It is also found that LED TVs show the best performance in standby mode. Moreover, an example to set standby power standards on TVs to be applied in the future is suggested, considering the energy efficiency policies for appliances.

Improved Direct Power Control of Shunt Active Power Filter with Minimum Reactive Power Variation and Minimum Apparent Power Variation Approaches

  • Trivedi, Tapankumar;Jadeja, Rajendrasinh;Bhatt, Praghnesh
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1124-1136
    • /
    • 2017
  • Direct Power Control technique has become popular in the grid connected Voltage Source Converter (VSC) applications due to its simplicity, direct voltage vector selection and improved dynamic performance. In this paper, a direct method to determine the effect of voltage vector on the instantaneous active and reactive power variations is developed. An alternative Look Up Table is proposed which minimizes the commutations in the converter and results in minimum reactive power variation. The application of suggested table is established for Shunt Active Power Filter (SAPF) application. The Predictive Direct Power Control method, which minimizes apparent power variation, is further investigated to reduce commutations in converters. Both the methods are validated using 2 kVA laboratory prototype of Shunt Active Power Filters (SAPF).

피상전력 손실감도에 의한 전압붕괴 근접도 지표와 무효전력 투자 (Voltage collapse proximity index based on system apparent power loss sensitivity and its application to VAR investment)

  • 이상중;김건중;김원겸;김용배;엄재선
    • 대한전기학회논문지
    • /
    • 제44권10호
    • /
    • pp.1290-1294
    • /
    • 1995
  • In this paper, a new voltage collapse proximity index (VCPI) based on system apparent power loss sensitivity is proposed. The newly proposed index .lambda.$^{Sloss}$ reaches -.inf. at system voltage collapse point and can be represented by .root..lambda.$^{Ploss}$$^{2}$+.lambda.$^{Qloss}$$^{2}$ where .lambda.$^{Ploss}$ and .lambda.$^{Qloss}$ are the VCPI based on the system active and reactive power loss sensitivity respectively. These indices can be used for the system VAR investment. .DELTA.Q [VAR] is invested, step by step, by the priority of the VCPI index given for each bus. The indices use information from normal power flow equations and their Jacobians. Computation time for deriving .lambda.$^{Sloss}$ is almost same as that for power flow calculation. Two case studies prove the effectiveness of the .lambda.$^{Sloss}$ index and the VAR investment algorithm proposed.

  • PDF

Space Charge Behavior of Oil-Impregnated Paper Insulation Aging at AC-DC Combined Voltages

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.635-642
    • /
    • 2014
  • The space charge behaviors of oil-paper insulation affect the stability and security of oil-filled converter transformers of traditional and new energies. This paper presents the results of the electrical aging of oil-impregnated paper under AC-DC combined voltages by the pulsed electro-acoustic technique. Data mining and feature extractions were performed on the influence of electrical aging on charge dynamics based on the experiment results in the first stage. Characteristic parameters such as total charge injection and apparent charge mobility were calculated. The influences of electrical aging on the trap energy distribution of an oil-paper insulation system were analyzed and discussed. Longer electrical aging time would increase the depth and energy density of charge trap, which decelerates the apparent charge mobility and increases the probability of hot electron formation. This mechanism would accelerate damage to the cellulose and the formation of discharge channels, enhance the acceleration of the electric field distortion, and shorten insulation lifetime under AC-DC combined voltages.

전자식 전력량계와 무선모듈을 이용한 전력품질 표시 및 모니터링 (Power Quality Monitoring with Electronic Watt-hour meter and Wireless communication module)

  • 정득일;손영대
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.172-174
    • /
    • 2007
  • An electronic watt-hour meter with high-precision measurement technology can provide many valuable metering data of a real-time system measurements, such as per-phase voltage, ampere, active power, reactive power, apparent power, power factor, and system frequency. Also many of accumulated metering data such as active energy, reactive energy, apparent energy, and load profile can be gettable from an electronic watt-hour meter[1]. This paper presents an approach of the small-sized AMR (Automatic Meter Reading) that provides customers with a very valuable electrical service. This AMR service transmits lots of a valuable metering data by using ZigBee communication module, so that users resided in their premises can use the information to audit a power quality and improve their electrical conditions by using the PQ monitoring device equipped with ZigBee receiver. This PQ monitoring device shows metering data on LCD and transmits to the PC through an internal network. Also, the device can keep the valuable meter data into a built-in non-volatile memory. The final goal of this paper is to better understand the power quality of electrical systems and offer the power qualify information for the convenience of all power consumers.

  • PDF

Feasibility of a Nonlinear Acoustic Method for the Assessment of Bone Status and Osteoporosis in Trabecular Bone

  • Lee, Kang Il
    • Journal of the Korean Physical Society
    • /
    • 제73권12호
    • /
    • pp.1849-1854
    • /
    • 2018
  • The present study aims to investigate the feasibility of using a simple nonlinear acoustic method for the assessment of bone status and osteoporosis in trabecular bone. Correlations of linear and nonlinear ultrasound parameters with the apparent bone density were obtained in 32 bovine femoral trabecular bone samples. Highly significant positive correlations were observed between the apparent bone density and the two linear ultrasound parameters, the speed of sound (SOS) and the normalized broadband ultrasound attenuation (nBUA), with Spearman's correlation coefficients of r = 0.85 and 0.77. In contrast, the apparent bone density was found to be negatively correlated with the nonlinear ultrasound parameter introduced in the present study, the logarithmic difference between the power spectrum levels of the fundamental frequency and the second harmonic (PSL1-PSL2), with the highest correlation coefficient of r = -0.92. These results suggest that the PSL1-PSL2, in addition to the SOS and the nBUA, may be useful for the assessment of bone status and osteoporosis.