Abstract

Direct Power Control technique has become popular in the grid connected Voltage Source Converter (VSC) applications due to its simplicity, direct voltage vector selection and improved dynamic performance. In this paper, a direct method to determine the effect of voltage vector on the instantaneous active and reactive power variations is developed. An alternative Look Up Table is proposed which minimizes the commutations in the converter and results in minimum reactive power variation. The application of suggested table is established for Shunt Active Power Filter (SAPF) application. The Predictive Direct Power Control method, which minimizes apparent power variation, is further investigated to reduce commutations in converters. Both the methods are validated using 2 kVA laboratory prototype of Shunt Active Power Filters (SAPF).

Keywords

References

  1. P. K. Marian and L. Malesani, "Current Control Techniques for Three-Phase Voltage-Source PWM Converters: A Survey," IEEE Transactions on Industrial Electronics, vol. 45, pp. 691-703, 1998.
  2. T. Trivedi, R. Jadeja, and P. Bhatt, "A Review on Direct Power Control for Applications to Grid Connected PWM Converters," Engineering, Technology & Applied Science Research, vol. 5, pp. 841-849, 2015.
  3. T. Noguchi, H. Tomiki, S. Kondo, and I. Takahashi, "Direct Power Control of PWM Converter Without Power Source Voltage Senesors," IEEE Transaction on Power Electronics, vol. 34, pp. 473-479, 1998.
  4. J. Alonso, M. Joaquin, E. Garcia, and C. Arnaltes, "Table Based Direct Power Control- A Critical Review for Microgrid Applications," IEEE Transactions on Power Electronics, vol. 25, pp. 2949-2961, 2010. https://doi.org/10.1109/TPEL.2010.2087039
  5. Z. Xu and J.-X. Zhao, "A New Direct Power Control Strategy for NPC Three-Level Voltage Source Rectifiers Using a Novel Vector Influence Table Method," JOURNAL OF POWER ELECTRONICS, vol. 15, pp. 106-115, 2015. https://doi.org/10.6113/JPE.2015.15.1.106
  6. M. Malinowski, M. P. Kazmierkowski, S. Hansen, F. Blaabjerg, and G. D. Marques, "Virtual-Flux Based Direct Power Control of Three-Phase PWM Rectifiers," IEEE Transaction on Industrial Applications, vol. 37, pp. 1019-1027, 2001. https://doi.org/10.1109/28.936392
  7. Sergio Vazquez, J. A. Sanchez, J. M. Carrasco, J. I. Leon, and E. Galvan, "A Model-Based Direct Power Control for Three-Phase Power Converters," IEEE Transactions on Industrial Electronics, vol. 55, pp. 1647-1657, 2008.
  8. Gerardo Escobar, A. M. Stankovic, J. M. Carrasco, E. Galvan, and R. Ortega, "Analysis and Design of Direct Power Control (DPC) for a Three Phase Synchronous Rectifier via Output Regulation Subspaces," IEEE Transactions on Power Electronics, vol. 18(3), pp. 823-830, 2003. https://doi.org/10.1109/TPEL.2003.810862
  9. Sergio Aurtenechea Larrinaga, M. A. Rodriguez, V. Estanis, Oyarbide Apraiz, and J. R. Torrealday, "Predictive Control Strategy for DC-AC Converters Based on Direct Power Control," IEEE Transactions on Industrial Electronics, vol. 54, pp. 1261-1271, 2007. https://doi.org/10.1109/TIE.2007.893162
  10. H. Jiabing and Z. Q. Zhu, "Investigation on Switching Patterns of Direct Power Control Strategies for Grid-Connected DC-AC Converters Based on Power Variation Rates," IEEE Transactions on Power Electronics, vol. 26, pp. 3582-3598, 2011. https://doi.org/10.1109/TPEL.2011.2164812
  11. D. Zhi and L. Xu, "Direct Power Control of DFIG With Constant Switching Frequency and Improved Transient Performance," IEEE Transactions on Energy Conversion, vol. 22(1), pp. 110-118, 2007. https://doi.org/10.1109/TEC.2006.889549
  12. G. J. Bruce S. Chen, "Direct Power Control of Active Filters with Averaged Switching Frequency Regulation," IEEE Transaction on Power Electronics, vol. 23, pp. 2729-2737, 2008. https://doi.org/10.1109/TPEL.2008.2004958
  13. M. Cichowlas, M. Malinowski, M. P. Kazmierkowski, D. L. Sobczuk, P. Rodriguez, and P. Josep, "Active Filtering Function of Three-Phase PWM Boost Rectifier Under Different Line Voltage Conditions," IEEE Transactions on Industrial Electronics, vol. 52, pp. 410-419, 2005. https://doi.org/10.1109/TIE.2005.843915
  14. Nadhir Mesbahia, A. Ouaria, D. Ould, A. T. Djamahc, and A. Omeiri, "Direct Power Control of Shunt Active Filter using High Selectivity Filter(HSF) under Distorted or Unbalanced Conditions," Electric Power Systems Research, vol. 108, pp. 113-123, 2014. https://doi.org/10.1016/j.epsr.2013.11.006

Cited by

  1. Reverse matrix converter control method for PMSM drives using DPC vol.105, pp.5, 2018, https://doi.org/10.1080/00207217.2017.1382012