• Title/Summary/Keyword: Apparent diffusion coefficient value

Search Result 55, Processing Time 0.028 seconds

The Comparison of Apparent Chloride Diffusion Coefficients in GGBFS Concrete Considering Sea Water Exposure Conditions (해양 폭로 환경에 따른 GGBFS 콘크리트의 겉보기 염화물 확산계수 비교)

  • Yoon, Yong-Sik;Jeong, Gi-Chan;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.2
    • /
    • pp.18-27
    • /
    • 2022
  • In this study, the time-dependent chloride ingress behavior in GGBFS concrete was evaluated considering marine exposure conditions and the properties of concrete mixtures. The concrete mixture for this study had 3 levels of water to binder ratio and the substitution rate of GGBFS, and outdoor exposure tests were performed considering submerged area, tidal area, and splash area. According to the evaluation results of diffusion coefficient considering properties of concrete mixtures, as the substitution rate of GGBFS increased, the decreasing rate of the diffusion coefficient decreased based on exposure periods of 730 days(2 years). As the evaluation result of the diffusion behavior according to the marine exposure conditions, the diffusion coefficient was evaluated in the order of submerged area, tidal area, and splash area. In tidal area, a relatively high diffusion coefficient was evaluated due to the repetition of wet and dry seawater. In this study, the effects of GGBFS substitution rate on the decreasing behavior of apparent chloride diffusion coefficient was analyzed in consideration of exposure conditions and periods. Linear regression analysis was performed with apparent chloride diffusion coefficient as output value and GGBFS substitution rate as input value. After 730 days of exposure, the effect of GGBFS on diffusion coefficient was significantly reduced. Even for OPC concrete, after 730 days, the diffusion coefficient was as low as that of GGBFS concrete, so the gradient of the regression equation decreased significantly. It is thought that improved durability performance for chloride ingress can be secured before 730 days through the use of GGBFS.

Diffusion-weighted Imaging and Apparent Diffusion Coefficient Maps for the Evaluation of Pyogenic Ventriculitis

  • Kim, Hyeong-Seok;Hong, Jae-Taek;Lee, Sang-Won;Son, Byung-Chul;Sung, Jae-Hoon;Kim, Moon-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.1
    • /
    • pp.23-27
    • /
    • 2005
  • Objective : The aim of this study is to assess the significance of an apparent diffusion coefficient[ADC] study for diagnosis of ventriculitis. Methods : Seven patients with ventriculitis were enrolled in this study. Diffusion-weighted[DW] magnetic resonance images[MRI] and ADC maps in the dependent intraventricular collection, periventricular white matter and non-dependent cerebrospinal fluid[CSF] were obtained. The images and ADC data from the different lesions were compared. Results : The DW MRI showed marked hyperintensity in the purulent pus lesion, and the corresponding ADC maps revealed prominent hypointensity and restricted ADC values compared with the non-dependent CSF and normal white matter. Conclusion : The decreased ADC value and increased signal intensity of the dependent intraventricular fluid on the DW MRI show restricted water diffusion in the purulent fluid, which is indicative of a pyogenic ventriculitis diagnosis.

Study of Apparent Diffusion Coefficient Changes According to Spinal Disease in MR Diffusion-weighted Image

  • Heo, Yeong-Cheol;Cho, Jae-Hwan
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.146-149
    • /
    • 2017
  • In this study, we compared the standardized value of each signal intensity, the apparent diffusion coefficient (ADC) that digitizes the diffusion of water molecules, and the signal to noise ratio (SNR) using b value 0 400, 1400 ($s/mm^2$). From March 2013 to December 2013, patients with suspicion of simple compound fracture and metastatic spine cancer were included in the MR readout. We used a 1.5 Tesla Achieva MRI system and a Syn-Spine Coil. Sequence is a DWI SE-EPI sagittal (diffusion weighted imaging spin echo-echo planar imaging sagittal) image with b-factor ($s/mm^2$) 0, 400, 1400 were used. Data analysis showed ROI (Region of Interest) in diseased area with high SI (signal intensity) in diffusion-weighted image b value 0 ($s/mm^2$) Using the MRIcro program, each SI was calculated with images of b-value 0, 400, and 1400 ($s/mm^2$), ADC map was obtained using Metlab Software with each image of b-value, The ADC is obtained by applying the ROI to the same position. The standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of simple compression fractures were $0.47{\pm}0.04$ and $0.23{\pm}0.03$ and the standardized values ($SI_{400}/SI_0$, $SI_{400}/SI_0$) of the metastatic spine were $0.57{\pm}0.07$ and $0.32{\pm}0.08$ And the standardized values of the two diseases were statistically significant (p < 0.05). The ADC ($mm^2/s$) for b value 400 ($s/mm^2$) and 1400 ($s/mm^2$) of the simple compression fracture disease site were $1.70{\pm}0.16$ and $0.93{\pm}0.28$ and $1.24{\pm}0.21$ and $0.80{\pm}0.15$ for the metastatic spine. The ADC ($mm^2/s$) for b value 400($s/mm^2$) was statistically significant (p < 0.05) but the ADC ($mm^2/s$) for b value 1400 (p > 0.05). In conclusion, multi - b value recognition of signal changes in diffusion - weighted imaging is very important for the diagnosis of various spinal diseases.

Diagnostic Significance of Apparent Diffusion Coefficient Values with Diffusion Weighted MRI in Breast Cancer: a Meta-Analysis

  • Sun, Jiang-Hong;Jiang, Li;Guo, Fei;Zhang, Xiu-Shi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.19
    • /
    • pp.8271-8277
    • /
    • 2014
  • Aims: Apparent diffusion coefficient (ADC) values of nodes in diffusion-weighted imaging (DWI) are widely used in differentiating metastatic from non-metastatic lymph nodes. The purpose of this meta-analysis was to demonstrate whether DWI could contribute to the precise diagnosis of breast cancer (BC) with and without lymph node metastasis (LNM). Materials and Methods: English and Chinese electronic databases were searched for relevant studies followed by a comprehensive literature search. Two reviewers independently assessed the methodological quality of the included trials based on the quality assessment of diagnostic accuracy studies (QUADAS). Summary odds ratios (ORs) and corresponding 95% confidence intervals (95% CIs) were calculated. Results: Final analysis of 624 BC subjects (patients with LNM = 254, patients without LNM = 370) were incorporated into the current meta-analysis from 9 eligible cohort studies. Combined ORs of ADCs suggested that ADC values in BC patients without LNM were higher than in patients with LNM (OR=0.56, 95%CI: 0.11-1.01, p=0.015). Subgroup analysis stratified by country indicated a low ADC value in BC patients with LNM rather than those without LNM among Chinese (OR=1.27, 95%CI: 0.89-1.66, p<0.001), Italians (OR=0.75, 95%CI: 0.13-1.38, p=0.018), and Egyptians (OR=1.27, 95%CI: 0.71-1.84, p<0.001). The findings of subgroup analysis by MRI machine type revealed that ADC values from diffusion MRI may be potential diagnostic indicators for BC using Non-Philips 1.5T (OR=1.10, 95%CI: 0.84-1.36, p<0.001). Conclusions: The main findings of our meta-analysis demonstrated that increased signal intensity on DWI and decreased signals on ADC are helpful in diagnosis of BC patients with or without LNM. DWI could therefore be an important imaging investigation in patients suspected of BC.

Changes in SNR and ADC According to the Increase in b Value in Liver Diffusion-Weighted Images

  • Cho, Jae-Hwan;Kim, Ham-Gyum
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.219-224
    • /
    • 2012
  • In the present study, changes in signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) of the diffusion-weighted images in the normal livers were investigated using changes in b values in 1.5 T MR (magnetic resonance) instruments. Respective diffusion-weighted images and ADC map images were obtained from 20 healthy individuals by increasing b values from 50 to 400 and 800 $s/mm^2$ using 1.5T MR scanner between January 2011 and November 2011. At each ADC map image obtained at each b value, ADCs in the right hepatic lobe, spleen and kidney were measured. As a result, ADCs of the right hepatic lobe, spleen and kidney have gradually decreased in the diffusion-weighted images in accordance with the reduced b value. This outcome may be used as preliminary data for applications to various abdominal diseases.

A Change of Apparent Diffusion Coefficient in Diffusion Weighted Imaging Applied with Rectangular FOV Technique (확산강조영상 검사 시 rectangular FOV 적용에 따른 ADC 값의 변화)

  • Na, Sa-Ra;Choi, Kwan-Woo;Koo, No-Hyun;Yoo, Beong-Gyu;Son, Soon-Yong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.7
    • /
    • pp.545-550
    • /
    • 2016
  • The purpose of this study is to improve the mapping between functional image and conventional image by using rectangular FOV technique. Diffusion weighted imaging which is widely used for stroke was acquired by reducing the FOV and compared each Apparent Diffusion Coefficient(ADC). As a result, there is no significant difference of each ADC value in one-way-anova analysis and post-hoc analysis. Thus, Mismatching problem may be improved by matching the FOV with rectangular FOV technique because there is no difference in ADC values.

Differential Diagnosis of Malignant Biliary Tract Cancer from Benign Tissues using Apparent Diffusion Coefficient Measurements with Diffusion Weighted Imaging in Asians

  • Zhao, Xu-Ya;Zhou, Shi;Wang, Da-Zhi;He, Wei;Li, Jun-Xiang;Zhang, Shuai
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.6135-6140
    • /
    • 2015
  • Background: The aim of this meta-analysis was to assess the efficacy of the apparent diffusion coefficient (ADC) value of diffusion-weighted MRI (DWI) for differentiating biliary tract cancer (BTC) from benign biliary tract diseases in Asians. Materials and Methods: We systematically searched Embase and PubMed prior to December 2014. Eight studies conducted in Asians met our predetermined inclusion criteria. Results: Our meta-analysis results showed that ADC values in BTC tissues were significantly lower than in benign biliary tract tissues (SMD = -1.54, 95%CI: -1.75~-1.33, P<0.001). Subgroup analysis based on the MRI machine type showed that the ADC values were consistent, accurate and reliable in the diagnosis of BTC when comparing cancer tissue vs. benign tissue under the Siemens 1.5 T/3.0 T, Philips 1.5 T/3.0 T, GE 1.5 T, and Toshiba 1.5 T types, respectively (all P<0.05). Further, ADC values were still consistent and accurate in the differential diagnosis of BTC under the b value of 800 and $1000s/mm^2$ (all P<0.05). Conclusions: Our findings supported potential clinical applications of DWI ADC values in differentiating BTC from benign biliary tract diseases in Asians.

Comparative Analysis of Signal Intensity and Apparent Diffusion Coefficient at Varying b-values in the Brain : Diffusion Weighted-Echo Planar Image ($T_2^*$ and FLAIR) Sequence (뇌의 확산강조 영상에서 b-value의 변화에 따른 신호강도, 현성확산계수에 관한 비교 분석 : 확산강조 에코평면영상($T_2^*$ 및 FLAIR)기법 중심으로)

  • Oh, Jong-Kap;Im, Jung-Yeol
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.313-323
    • /
    • 2009
  • Diffusion-weighted imaging (DWI) has been demonstrated to be a practical method for the diagnosis of various brain diseases such as acute infarction, brain tumor, and white matter disease. In this study, we used two techniques to examine the average signal intensity (SI) and apparent diffusion coefficient (ADC) of the brains of patients who ranged in age from 10 to 60 years. Our results indicated that the average SI was the highest in amygdala (as derived from DWI), whereas that in the cerebrospinal fluid was the lowest. The average ADC was the highest in the cerebrospinal fluid, whereas the lowest measurement was derived from the pons. The average SI and ADC were higher in $T_2^*$-DW-EPI than in FLAIR-DW-EPI. The higher the b-value, the smaller the average difference in both imaging techniques; the lower the b-value, the greater the average difference. Also, comparative analysis of the brains of patients who had experienced cerebral infarction showed no distinct lesion in the general MR image over time. However, there was a high SI in apparent weighted images. Analysis of other brain diseases (e.g., bleeding, acute, subacute, chronic infarction) indicated SI variance in accordance with characteristics of the two techniques. The higher the SI, the lower the ADC. Taken together, the value of SI and ADC in accordance with frequently occurring areas and various brain disease varies based on the b-value and imaging technique. Because they provide additional useful information in the diagnosis and treatment of patients with various brain diseases through signal recognition, the proper imaging technique and b-value are important for the detection and interpretation of subacute stroke and other brain diseases.

  • PDF

An Investigation of Diffusion of Iodide Ion in Compacted Bentonite Containing Ag2O (Ag2O를 첨가한 압축 벤토나이트에 대한 요오드 이온의 확산 특성 관찰)

  • Yim, Sung-Paal;Lee, Ji-Hyun;Choi, Heui-Joo;Choi, Jong-Won;Lee, Cheo-Kyung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.9 no.1
    • /
    • pp.33-40
    • /
    • 2011
  • In the compacted bentonite containing $Ag_2O$, the transport of iodide ion was investigated by Through-diffusion method. It is confirmed that Iodide ion is transported by diffusion process in the compacted bentonite containing $Ag_2O$ as well as in the compacted bentonite without $Ag_2O$. However, the lag-time of iodide ion in the compacted bentonite containing $Ag_2O$ is larger than that in the compacted bentonite without $Ag_2O$. The increase of the lag-time was observed in pure iodide ion solution and also in 0.1M NaCl-iodide ion solution. The apparent diffusion coefficient of iodide ion in the compacted bentonite containing $Ag_2O$ has lower value than that in the compacted bentonite without $Ag_2O$. The effect of $Ag_2O$ on the effective diffusion coefficient was not clearly investigated in the compacted bentonite containing $Ag_2O$ while the values of effective diffusion coefficient of iodide ion in the compacted bentonite without $Ag_2O$ obtained in this study were similar to those in the compacted bentonite reported in the literature.

Differentiation of Benign from Malignant Adnexal Masses by Functional 3 Tesla MRI Techniques: Diffusion-Weighted Imaging and Time-Intensity Curves of Dynamic Contrast-Enhanced MRI

  • Malek, Mahrooz;Pourashraf, Maryam;Mousavi, Azam Sadat;Rahmani, Maryam;Ahmadinejad, Nasrin;Alipour, Azam;Hashemi, Firoozeh Sadat;Shakiba, Madjid
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.8
    • /
    • pp.3407-3412
    • /
    • 2015
  • Background: The aim of this study was to evaluate and compare the accuracy of diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC) value, and time-intensity curve (TIC) type analysis derived from dynamic contrast-enhanced MR imaging (DCE-MRI) in differentiating benign from malignant adnexal masses. Materials and Methods: 47 patients with 56 adnexal masses (27 malignant and 29 benign) underwent DWI and DCE-MRI examinations, prior to surgery. DWI signal intensity, mean ADC value, and TIC type were determined for all the masses. Results: High signal intensity on DWI and type 3 TIC were helpful in differentiating benign from malignant adnexal masses (p<0.001). The mean ADC value was significantly lower in malignant adnexal masses (p<0.001). An ADC value< $1.20{\times}10^{-3}mm^2/s$ may be the optimal cutoff for differentiating between benign and malignant tumors. The negative predictive value for low signal intensity on DWI, and type 1 TIC were 100%. The pairwise comparison among the receiver operating characteristic (ROC) curves showed that the area under the curve (AUC) of TIC was significantly larger than the AUCs of DWI and ADC (p<0.001 for comparison of TIC and DWI, p<0.02 for comparison of TIC and ADC value). Conclusions: DWI, ADC value and TIC type derived from DCE-MRI are all sensitive and relatively specific methods for differentiating benign from malignant adnexal masses. By comparing these functional MR techniques, TIC was found to be more accurate than DWI and ADC.