Development and Applicability of Discharge Capacity Testing Apparatus Using Penetration Method (관입식 복합 통수능 시험기의 개발과 적용성)

  • Yoo, Nam Jae;Kim, Dong Gun;Park, Byung Soo;Jun, Sang Hyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5C
    • /
    • pp.313-320
    • /
    • 2008
  • The discharge capacity testing apparatus using penetration method, being able to simulate in laboratory the condition of embedding plastic board drains in field, was developed to investigate consolidation characteristics of ground and to figure out discharge capacity of drains. The developed apparatus with a mandrel and penetrating device was designed to insert PBD into the ground prepared by previously applied pressure, being different from the conventional testing method that the drain was installed and the ground material was poured subsequently. Discharge capacity tests with the conventional apparatus as well as the newly developed one were performed to assess the applicability of the latter. As a result of tests, the conventional method showed delayed consolidation due to overall disturbance of ground and local deformation of drain caused by inhomogeneity of ground. Therefore discharge capacity of drain with the conventional apparatus was measured more or less larger than the expected values whereas discharge capacity with new one could be measured similar to the actual value in field.

Numerical Analyses about Test Results of Discharge Capacity Apparatus Using Penetration Method (관입식 통수능 실험의 수치해석)

  • Yoo, Nam-Jae;Woo, Young-Min;Jun, Sang-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.720-728
    • /
    • 2009
  • This thesis is results of numerical analyses about test results of discharge capacity apparatus using penetration method. Applicability of numerical approach with FEM technique, using Cam-clay model, was confirmed by analyzing the results of standard consolidation test before analyzing test results of discharge capacity apparatus using penetration method. Thus, input parameters for the model was convinced to be appropriate. For numerical analyses about test results of discharge capacity apparatus using penetration method, identical initial and loading conditions during tests were applied to simulate test results correctly. Effects of ground disturbance resulted from installment of vertical drains on the behaviors of consolidation were also simulated. Applicability of numerical approach was investigated by comparing test results with numerical ones. As results of them, both of consolidation settlement were found to be in good agreements so that its applicability was confirmed. As results of numerical estimation, degree of consolidation with the condition of considering smear zone was found to be delayed, compared with results without smear zone. On the other hands, parametric numerical analyses of changing parameters related to smear zone such as permeability and size of smear zone and permeability of vertical drain were also carried out.

  • PDF

Capacity Evaluation of Cylindrical Plastic Board Drain with The Composite Discharge Capacity Apparatus (복합통수능시험기를 이용한 실린더형 플라스틱 보드 드레인의 성능 평가)

  • Lee, Chan-Woo;Jung, Du-Hwoe;Kim, Yun-Tae;Jin, Kyu-Nam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.293-299
    • /
    • 2008
  • If a conventional type of Plastic Board Drain (PBD) is installed to the deep clay deposit, it is subjected to a high lateral earth pressure. a flow channel of PBD may be reduced by the collapse of cores and clogged by the intrusion of filter into the space between cores which are made by lateral pressure. It could decrease the ability of initial discharge capacity and the reliability of long term discharge capacity. A cylindrical plastic board drain (C-PBD) considered in this study consists of cylindrical core and several supports so that it can prevent the reduction of area of flow channel from the higher lateral earth pressure effectively. The discharge capacity of C-PBD was compared to that of a conventional PBD through performing experiments using the composite discharge capacity apparatus which can consider in-situ condition such as penetration of drains, ground settlement and discharge capacity. As a result, C-PBD showed much better performance than PBD in the ability of discharge. It was observed that the C-PBD was folded whereas the conventional PBD was folded after the experiment.

  • PDF

A Design of a Simulation Apparatus for the Control of the Personal Rapid Transit(PRT) Vehicles (소형궤도 차량 제어를 위한 모의실험 장치 설계)

  • Lee, Jun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2001-2005
    • /
    • 2008
  • This paper presents a design of a simulation apparatus to evaluate an operational control algorithm for the PRT system. PRT systems require very short headways to increase the line capacity and a very reliable vehicle control algorithm for avoidance of the impact between vehicles. Therefore, it can be said that the development of an reliable operational control algorithm for the PRT systems is much more important than that of the hardware configurations. In this paper an apparatus is proposed which is composed of virtual vehicles, a central control system, a man-machine interface and monitoring device, making it possible for the designed operational control algorithm to be implemented and tested. For the test of the proposed apparatus a test operational control algorithm is designed and the experimental results show the effectiveness of the proposed simulation apparatus for test and evaluation of the PRT operational control algorithms.

Analysis on the Discharge Capacity of Vertical Drains Installed in the Field (현장에 타설된 연직배수재의 통수능력 분석)

  • 박영목;진규남;정하익;정길수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.512-519
    • /
    • 2000
  • The discharge capacity of vertical drains installed in the field is reduced with time elapsed after installation due to deformation of drains and clogging effect. Discharge capacity of two types of vertical drains was analysed about three years after installation in the subsoil. Discharge capacity of two types of vertical drains were measured by small, middle, and large scale test apparatus. The results indicate that the discharge capacity of vertical drains after three years operation dramatically decreased compare to the initial discharge capacity.

  • PDF

Scheme for Measuring Refrigeration Capacity of Cryopump Refrigerator (크라이오 펌프 냉동기 냉각용량 측정방안)

  • In, S.R.;Cho, H.S.;Jeong, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.243-251
    • /
    • 2011
  • An apparatus for measuring the refrigeration capacity of cryopump refrigerators including the pulse tube type being developed domestically and the GM type has been designed, manufactured, and tested. The refrigeration capacity of a commercial refrigerator was evaluated for confirming the measurement procedure and the operation performance of the apparatus. The measured 2-D refrigeration capacity chart showed the intrinsic characteristics of the refrigerator model used in the experiment. In this paper, design specifications and test results of the refrigeration capacity measurement system is reported and discussed.

The Evaluation of CO Adsorbents Used in PSA Process for the Purification of Reformed Hydrogen (개질 수소 정제용 PSA 공정을 위한 CO 흡착제의 성능 평가)

  • PARK, JIN-NAM
    • Journal of Hydrogen and New Energy
    • /
    • v.27 no.6
    • /
    • pp.628-635
    • /
    • 2016
  • Natural gas reformed hydrogen is used as a fuel of fuel cell vehicle, PSA process is used for the purification of reformed hydrogen. In this study, the performance of CO adsorbent in PSA process was evaluated. Zeolite adsorbents used in the commercial PSA process is used. The physical and chemical properties of adsorbents were characterized using BET apparatus, XRD, and FE-SEM. The breakthrough apparatus modified from GC was used for the CO breakthrough experiment, the quantitative analysis of CO adsorption capacity was performed using CO breakthrough curve. Zeolite 10X and 13X showed superior CO adsorption capacity than activated alumina. The CO adsorption capacity of zeolite 10X is more than twice of zeolite 13X even the BET surface area is low. It seems that the presence of $Ca^{2+}$ cation in zeolite 10X is beneficial to the adsorption of CO.

The Applied Technology of Mold Transformer for Outdoor Use (옥외 주상용 몰드 변압기인 적용 기술)

  • Han, Se-Won;Cho, Han-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.23-28
    • /
    • 2000
  • Insulator systems using resin casting apparatus are useful to realize the high capacity, small size, and combined electric power equipments, and are expected to bring various advantages. In Korea, epoxy resin molded apparatus have been restricted to indoor uses till now. On the other hand, in Europe, molded insulators and transformers and so forth have been practically used since the former half of 1960's. Recently, investigation on epoxy resin materials and molded apparatus for outdoor use have ben intensively carried out. Probably, this is because electric power outdoor apparatus such as distribution transformer can be given multi-functions by using outdoor epoxy resin compound This study describes the trend on the development of epoxy mold transformers, and important technologies applied for outdoor use.

  • PDF

A Study on Contaminant Sorption Capacity of Soil Liner for Seashore Waste Landfill by Using Column Test Apparatus (주상시험장치를 이용한 해안 폐기물 매립장 지반토지 오염물 흡착능에 관한 연구)

  • Jang, Yeon-Su;Han, Seong-Gil;Kim, Su-Sam
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.75-84
    • /
    • 1997
  • In this paper, the retardation capacity of marine clay and weathered soil of seashore waste landfill is analyzed by using a laboratory column apparatus for organic and inorganic components which can represent the components of the leachate of municipal waste landfill. The results show that sorption capacity marine clay for potassium is larger than that of weathered soil. Lead and cadmium are adsorbed completely at concentrations higher than the real concentrations developed in the landfill. The bottom soils of seashore landfill can also retard some nondegradable components of organics although their sorption capacities for organics were less than those for inorganics.

  • PDF

An Experimental Study of a Therr Buffer Pulse Tube Refrigerator (Three Buffer 맥동관 냉동기에 관한 실험적 연구)

  • 박성재;고득용;김효봉;신완순
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.54-59
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus operating process of the therr buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the three buffer pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27 W at 120K.

  • PDF