A Case Study on Arrangement and Application of Public Facilities on Lower Levels in the Multiple-Family Housing (공동주택 단지 주동 저층부 공용시설의 배치와 활용 현황)

  • Hur, Bo-Hyung;Yang, Woo-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2004.11a
    • /
    • pp.177-182
    • /
    • 2004
  • To cope with the serious housing shortage arising from rapid urbanization and industrialization, residential communities were constructed to meet the growing demand for housing. However, mass construction of these residential communities unavoidably resulted in uniformity standardization. In particular, for high rise apartment blocs using the ground floor as the center of the lower levels housings has raised problem of sunshine, airing, privacy. The research which it sees as the house low evaluation it is coming to become it plans a public facilities on lower levels of the building which keeps the quality which the ground connection and human scale back separates as, to solve the problem point of the lower levels house and the resident collective life which is smooth becomes accomplished.

  • PDF

Prototype Development for BIM based Thermal Insulation and Condensation Performance Evaluation of Apartment Housings

  • Oh, Hyangok;Cho, Daegu;Jang, Hyang-In;Hong, Soungwook;Lee, Myung Sik
    • Architectural research
    • /
    • v.17 no.2
    • /
    • pp.75-81
    • /
    • 2015
  • Insulation and condensation performance evaluation (I&CPE) is an important energy analysis. While considerable amount of data are already represented in a Building Information Model (BIM), the lack of interoperability between BIM modeling and I&CPE programs prevents the simulation process from being efficient and accurate. This study proposes a prototype of a BIM-based I&CPE simulation program, in order to enhance the interoperability between BIM modeling and I&CPE programs. This study discusses the information flow process, defines the required information and its level of detail, develops standardized libraries, and finally proposes a prototype that consists of a data extraction module, conversion module, and performance module. The assurance of interoperability between systems might greatly benefit architects and energy professionals.

The Spillover Effect of Public Hosing Policy on Rental Housing Market: The Case of Seoul, Korea (공공임대주택이 주변 전세시장에 미치는 효과: 서울시 장기전세주택(SHIFT)의 경우)

  • Yang, Jun-Seok
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.405-418
    • /
    • 2017
  • SHIFT is public rental housing policy introduced by Seoul Metropolitan in 2007, which works as Chonsei(korean unique deposit rental system). This paper examines the effect of SHIFT on Chonsei prices of neighborhood apartments. To estimate the change in prices of Chonsei after the provision of SHIFT, I collect data on Chonsei prices of apartments within a 5km radius from the SHIFT housings. Summary of main results are following. Chonsei prices of the apartments within a 2-3km radius decreased by 4.4% after the provision of SHIFT housings. In contrast, when it comes to apartments within a 1-2km radius, I can't find the stochastic relationship between the provision of SHIFT hosing and price changes. This results can be explained by "Offset effects" caused by real estate development. Provision of SHIFT can sequentially induce nearby area's development, which plays a factor in the effect of price increases. And this offset effects varies in each apartment complex depending on demand for Chonsei and supply of the SHIFT.

Characteristics of Reducing the Water-drainage Noise of Toilet-bowl According to the Composition of Water Drainage Piping Materials of the Bathrooms of Apartment Housing (공동주택 욕실 배수배관 자재 구성에 따른 양변기 배수소음 저감 특성)

  • Jeong, A-Yeong;Kim, Kyoung-woo;Shin, Hye-kyung;Yang, Kwan-seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.114-120
    • /
    • 2017
  • Water supply and drainage noise in the bathroom is recognized as one of the main noises, along with the floor-impact sounds, in apartment housings. Recently, to solve such noise issues, a new construction method of installing the piping on the slab has been adopted. rather than the traditional method of penetrating the piping through the slab between the upper and the lower bathrooms. However, this new method has limitations due to high costs and constructional difficulties. Therefore, this study was conducted to develop noise reducing piping and elbows, where the noise can be reduced simply by replacing the existing pipings. The noise level was measured in a laboratory by installing the horizontal drainage piping (three types) and the elbows (three types) developed in this study. The results showed that the horizontal pipings reduced the noise level in LAmax by 0.3 dB(A)~1.0 dB(A), as compared to the existing pipings (VG2), indicating an insignificant noise reduction effect. The elbow reduced the noise level in LAmax by 5.5 dB(A) ~ 11.5 dB(A), as compared to the existing elbow (DRF elbow), with the result of reducing the noise level at all frequencies evenly. Consequently, it was shown that using the elbows is more effective in reducing the water-drainage noise from the toilet than using the horizontal pipings.

Priority of Residential Choice and Housing Satisfaction among Studio-type Multi-family Housing Dwellers in the City of Gwangju (원룸형 다가구주택 거주자의 주거선택 중요도와 주거만족도 - 광주광역시를 중심으로 -)

  • Kang, Hi-Goo;Kim, Mi-Hee
    • Journal of the Korean housing association
    • /
    • v.21 no.3
    • /
    • pp.11-21
    • /
    • 2010
  • The purpose of this study is to gather baseline data on perceived priority of residential choice and housing satisfaction rates among consumers with the aim of using this information for future planning. Self-administered questionnaires were provided to 196 studio-type multi-family housing dwellers in the City of Gwangju from 2009 Apri 5th to 29th. The collected data was used to conduct comparative and descriptive statistical analysis: factor analysis, t-test, one-way ANOVA, correlation analysis. The main findings obtained are as follows: Firstly, in relation to perceived priority of residential choice, dwellers identified seven factors as important. Secondly, in terms of housing satisfaction about a unit room, the respondents identified five factors as important. This study confirmed that there existed passive correlation between priority of residential choice and housing satisfaction among residents in studio-type multi-family housings in Gwangju. It is very necessary to project a studio-type multi-family housing close to transportation for easy access, avoiding commercial districts. Delicate interior and design will attract more female residents as well as fully-equipped parking lots for people who drive to their workplace. According to research on a degree of housing satisfaction, all respondents expressed dissatisfaction with "noise". Therefore, in dealing with construction plans of studio apartment units, from now on, sound proofing facilities are required to reduce the acoustic invasion of privacy, especially, for units with more than two people. In order to satisfy all the demand of residents in studio apartment units, we have to pursue systematic and succeeding research about a studio-type multi-family housing well-fitted for the actual circumstances of local area and suitable for longer stay. To sum up, more research and development will be required for high-class studio-type multiplex housing for sale in dealing with households with financial stability such as two-paycheck couples, so-called DINK, or a professional single person, in the future.

An Evaluation of the Linear Thermal Transmittance for the Internal Insulation versus the External Insulation in Apartment Housings (공동주택의 단열형태별 선형열관류율 평가)

  • Lee, Jong-Sung;Lee, Do-Heun;Jun, Myoung-Hoon
    • Land and Housing Review
    • /
    • v.5 no.4
    • /
    • pp.315-323
    • /
    • 2014
  • In this study, thermal transmittance which is a parameter to measure the thermal performance was evaluated for an internal insulation versus an external insulation. Then the ISO regulation was applied to evaluate it, and the superiority of an external insulation was verified by the thermal transmittance values. The three zones of apartment housing were selected to evaluate the performance. (1) The junction of an outer wall and a protruded slab : If there is no a thermal bridge protection system, then the values are about same in the two insulation systems, so the protection system should certainly be installed. If it is installed, then the value for the external insulation is 2 times lower than internal system. (2) The junction of a side wall and a flat slab: The value is 0.509W/mK for the internal insulation and about zero for the external insulation. (3) The junction of an outer wall and a division wall: The value is 0.451W/mK for the internal insulation and also about zero for the external insulation. A domestic regulation that could evaluate a thermal transmittance has to be established by applying the ISO regulation for the evaluation of external insulation systems in apartment housing in the future. Additionally, the government must decide which length should be used for the national standard.

A Study on the Performance of the Hybrid Ventilation System for Apartment Houses (공동주택의 하이브리드 환기시스템 성능평가 연구)

  • Chun, Chu-Young;Kim, Gil-Tae;Kim, Sang-Hee
    • Land and Housing Review
    • /
    • v.3 no.1
    • /
    • pp.89-96
    • /
    • 2012
  • The purpose of this study was to evaluate the applicability of hybrid ventilation system in apartment housings and present a design method to improve the performance of hybrid ventilation system using the CFD simulation. As the object of CFD simulation, a small apartment houses with area of $51m^2$ and $81m^2$ were selected and evaluated. The test hybrid ventilation system are window frame natural air supply & duct exhaust hybrid system(Hybrid 1) and window frame natural air supply & bathroom and livingroom exhaust hybrid ventilation system(Hybrid 2). To evaluate the ventilation efficiency, we used the locations of diffuser installed for each system as the variables through the CFD simulation. In the case of Hybrid 1, the ventilation efficiency of the exhaust duct diffuser located on the inside room was higher rather than the exhaust duct diffuser located on the entrance. In the case of Hybrid 2, the most efficient system was the system that the diffuser connecting the bathroom static pressure fan is installed on the center of the living room. The ventilation efficiency of the Hybrid 2 in the case of $51m^2$ type was more than 20% of the Hybrid 1. But, The ventilation efficiency of the Hybrid 2 in the case of $84m^2$ type was more than 14% of the Hybrid 1. Therefore, to apply the Hybrid ventilation, a study that considers various variable should be conducted.

A Study on Benefit/Cost Analysis of Re-Bar Connection Methods for Hyper Strength(SD500) Reinforcement (SD500철근 커플러 이음의 편익/비용분석에 관한 연구)

  • Kim, Jae-Yeob;Kwon, Yeo-Wool;Kim, Jun-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.81-87
    • /
    • 2008
  • High-rise building is taking a place as one of building types from apartment housings to commercial buildings. With taking in account of stability and durability, strength of used materials is increasing gradually in these high-rise buildings. According to this, frequency in use of SD500 re-bar is increasing gradually in high-rise buildings. However the study of SD500 re-bar is insufficient because SD500 re-bar started to be used for domestic buildings lately. Specially because there is no guide or study to refer to, people get into difficulties when to decide the method of re-bar connection in construction using SD500 re-bar. Accordingly in this study, it suggests the method of estimating the economical efficiency on SD500 re-bar connection, and conducts benefit/ cost analysis on lapped splice and coupler splice by applying AHP theory, and then presents its result. After to analyze re-bar diameter of D25, 29, and 32, finally we attained the result that the coupler splice is advantageous in all parts of benefit/ cost more than the lapped splice.

A Study on System of Housing Adaptation Items' For Elderly People (노인가구 주택개조항목 설정 체계에 관한 연구;유니버설 디자인을 중심으로)

  • Park, Sung-Jun;Lee, Hyun-Soo
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2006.11a
    • /
    • pp.159-162
    • /
    • 2006
  • The purpose of this study is to set up systematically housing adaptation items for the aged family. Housing adaptation items are classified by universal design principles. Also, this paper suggest to basic data for setting up various ranges according to each elderly people's conditions, adapting for elderly housing. Recently, in relation to the growing awareness of the ageing population, the necessity of policies for "aging in place" was emphasized by government. This paper is focused on the policy of elderly housings' adaptation for making housing for a lifetime. This new adaptation items for the elderly housing lead to the revitalization of policy ensuring housing in stock at the local authority level. In this paper, adaptation items were created after analyzing indices highlighted by previous studies related to evaluation items, design-guidelines for safety plans, designing elderly housing. The scope of adaptation items was limited to the indoor spaces of apartment due to the considerable increase of in-house accidents. To sum up, this study is aimed to set up adaptation items and then, to present the basic scheme for several users offering various ranges

  • PDF

Empirical Analysis and Planning Implications for Community Street in Housing Complexes (집합주택단지 생활가로 조성 사례의 활용과 계획적 의미 분석)

  • Kim, Jin-Sung;Lee, Hyun-Jin;Yang, Woo-Hyun
    • Journal of the Korean housing association
    • /
    • v.18 no.6
    • /
    • pp.103-113
    • /
    • 2007
  • In Korea, open spaces of urban housing do not serve residents as "regular living areas". We carried out research on the "streets" of urban housings in that the meaning of traditional "streets", playing roles which are not only means of passage but also boundary of life, cannot include present meaning of "streets" of the urban housing. This research is to propose the direction of planning Community Streets for the recovery of the public- and communal urban housing's streets, researching the present employment condition of Community Streets that were prepared recently. Working with 3 complexes which have been completed since 2000, We studied the present employment condition and planned signification, according to the conditions of their surroundings, the physical conditions of Community Streets, and the relationship among main apartment buildings, open spaces, and facilities. From this study, We came up with several suggestions that can present the planning line of Community Streets. Therefore this research is to create the Community Streets for the activity of the streets, the recovery of the community, and improvement of ambulatory environment.