• Title/Summary/Keyword: Apartment fire

Search Result 198, Processing Time 0.025 seconds

A Checklist and Manual Developed to Review Fire Safety Facilities' Compliance with Fire Safety Requirements for Apartment Buildings (공동주택 소방시설 적법성 검토를 위한 화재안전규정 체크리스트 및 매뉴얼 개발)

  • Jeong, Soo-jin;Park, Yoo-na;Kim, Jae-jun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.19 no.6
    • /
    • pp.94-102
    • /
    • 2018
  • Recently, there is a growing need to review compliance with legal requirements to ensure fire safety as the number of fires caused by noncompliant fire safety facilities in high-rise buildings has increased. While there are a large number of apartment buildings in Korea, there is a lack of review on fire safety facilities' compliance with fire safety requirements. The reason for this lack of review despite apartment buildings causing deaths due to their structural features in the event of a fire, lies in the misinterpretation of legal provisions as the Building Act and the Fire Services Act are mixed up; a final inspection when fire safety facilities are unnecessarily installed or missing could result in significant losses in terms of finances and time. Therefore, this study developed a checklist that makes it possible to review mixed-up legal requirements for fire safety facilities simultaneously, and examined the importance and current level of each item through IPA (Importance Performance Analysis). Based on these results, this study intends to develop a manual that considers its applicability to construction practices and contribute to reducing construction companies' fire safety inspection risks.

A Study on risk management measurers about High-rise APT (고층아파트 위험관리 방안)

  • Kim, Jong Won
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.2
    • /
    • pp.178-187
    • /
    • 2013
  • This paper studied the potential risk of high-rise apartment by analysis of the loss ratio of housing fire insurance, statistics related high-rise apartment fire, and the insured amount of housing fire insurance, and, found that it is so high and need the improvement of risk management measures for high-rise apartment. Accordingly, the study recommend the composit risk management measures including preventing of fire expanding for higher stories, a shelter for people of hire-rise apartment, and sprinkler protection, etc. Also as risk transfer measures, the composit risk measures for high-rise apartment includes the full insurance of housing fire insurance, third party property liability insurance, and development of endorsement for special risk such as a typhoon, liability etc.

Multivariate Analysis of Fire Prevention Activities, Special Investigations of Fire Safety, and Fire Safety Management by the Apartment Buildings Management Methods and Inspection of Firefighting Facilities (공동주택 관리방식과 소방시설의 점검에 따른 예방활동·화재안전특별조사·소방안전관리의 다변량 분석)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.489-502
    • /
    • 2020
  • This study shows the difference between groups with multivariate analysis of fire prevention activities, special investigations of fire safety, and fire safety management according to the management method of apartment houses and the inspection of firefighting facilities. The results of the analysis are as follows. First, there was a significant difference in fire prevention activities according to the quality of inspection of firefighting facilities. This means that fire prevention is high if the fire safety manager's ability to inspect firefighting facilities is excellent and the fire safety inspection is conducted in accordance with national fire safety standards and checklists. Second, there was a significant difference in the fire safety special investigation according to the management method of the apartment buildings. The manual operated by the management entity and the management entity's management and execution help the organization members to expedite work. This expedition of work creates a high possiblity to get a good evaluation from the special investigation of fire safety. Third, analysis of fire prevention activities showed a significant interaction between the inspection of firefighting facilities and the management method of apartment buildings. The analysis shows that that there is a positive correlation between the level of fire prevention and both the fire safety manager's ability to inspect firefighting facilities and the degree to which the inspection is conducted to meet national fire safety standards.

A Study on Investigation into Actual Condition of Management in Fire Protection System -Apartment Buildings, Shopping Center, Office Buildings- (소방시설 관리실태조사에 관한 연구 -공동주택, 상가건축물, 사무소건축물-)

  • 김홍배;한상민;이영재;조병선
    • Fire Science and Engineering
    • /
    • v.15 no.3
    • /
    • pp.70-76
    • /
    • 2001
  • In a daily life these days, the safety and the comfort are considered very important. As the same as other areas, the good maintenance of fire protection systems and the fire drill plans in buildings can minimize the loss of human life and the property in case of fires. In this paper, a survey has been conducted to investigate the maintenance status of the fire protection systems of apartment buildings, shopping center and office buildings. Both practical procedures for checking the systems and for fire drills and strategic plans to minimize the losses in case of fires are suggested by analyzing how well the occupants in the buildings acknowledge the evacuation drills when the fire occurs.

  • PDF

A Case of Sprinkler Non-Working by Programming Error (프로그래밍 오류에 의한 스프링클러 미작동 사례)

  • Seo, Young-Il;Cho, Young-Jin;Moon, Byung-Seon;Park, Jong-Jin;Park, Jong-Chan;Park, Nam-Kyu
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.116-120
    • /
    • 2008
  • According to the Fire Services Act revised in 2005, it has been required to set up sprinkler systems to all floors to the newly builded apartments having above 11 floors. But, according to the Fire Services Act before 2005, it had been required to set up sprinkler systems from 16 floors to the top floors to the apartments having above 16 floors. This case is the accident that a victim was dead by the fire which is inferred as an accidental fire by a cigarette butt in a 17th floor apartment unit in an apartment having 17th floors and that the bereaved family called in question why the sprinklers non worked at the fire. Through the field investigation, we checked that the sprinklers worked well when the fire detectors at the 16th floor of the apartment were operated and that the sprinklers non worked when the fire detectors at the 17th floor of the apartment were operated. We made clear that the cause of the sprinkler non-working at the 17th floor is the programming error of the sprinkler controller.

Statistical Analysis on the Structure and Performance of the Front Door in Apartment Housing (공동주택 세대 현관 방화문 구조 및 성능에 관한 통계적 분석)

  • Shim, Han-Young;Park, Won-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.1
    • /
    • pp.115-123
    • /
    • 2022
  • Statistics on the occurrence of fires in residential facilities over the past 10 years, show that approximately 40% are fires in apartment buildings. To prevent the spread of fire and support evacuation in apartment housing, the fire resistance performance and performance design of fire doors are becoming more important. This study established a database using 395 quality inspection reports from 2016 to 2020, which passed the fire performance test, and derived the fire door performance-influencing factors through an analysis of the structure (12 elements) of the fire door. As a result, the effect of core material, adhesive, hinge type, blowing agent, etc. was confirmed in 287 pass cases. On the other hand, it was confirmed that the occurrence of flames and crevices in the 108 cases of failure were the major failure factors in the fire door fire resistance test. Fire doors are composed of composite materials to prevent failure of fire resistance performance, and efficient design and quality control are required through standardization of components.

The Influence of the Presence of Balconies on Flame Acceleration in Multi-unit Dwellings (공동주택의 발코니 유·무가 화염분출 특성에 미치는 영향 연구)

  • Kang, Youn-Gyu
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.1-6
    • /
    • 2016
  • We are living in the 21st century, a new era of high-technology. Due to movements in population towards certain preferred areas, caused by material and technological advancement, growth has occurredn beyond the metropolis, leading to the development of the so-calleda "megalopolis." This development has changed the culture of housing, notably the characteristics of high-rise buildings, and underground facilities (such as subways and shopping centers), and has generally enlarged the scale of the facilities. Due to the increase in the number of single-family households, - notably ones including only the nuclear family, there has been a growing overpopulation problem, with apartments and urban housing developments expanding at rates beyond institutional safety regulations. In this study, we analyze the phenomenon of fire spreading in apartment buildings through actual apartment fire case studies, including that of the MunjonPonpuri apartment building. It was found that the speed at which the fire spreads is lower in apartments without than in those with an extended balcony. Based on the findings from case studies and the test results, we propose a series of safety countermeasures and responses for apartment fires.

How Visual-Field Obstruction from Fire Smoke Influences a Resident's Necessary Time to Reach Fire Escape and Evacuation Route in a High-rise Apartment Housing (연기발생으로 인한 시야장애가 초고층 공동주택 거주자의 피난계단실 진입시간과 피난경로에 미치는 영향)

  • Seo, Sang-Mok;Choi, Jun-Ho;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.19 no.5
    • /
    • pp.103-110
    • /
    • 2008
  • The purpose of this study is to know how visual-field obstruction from fire smoke influences a resident's necessary time to reach fire escape and evacuation movement in a high-rise apartment housing. Generally, fire smoke not only gives visual-field obstruction and breath troubles to residents but interrupts their evacuation behavior. If a fire smoke layer is formed in the core department when evacuee enters at the evacuation staircase until, residents will be made to undergo a range of vision obstacle. In order to set a situation like that, participants wore eye bandage which had been made especially before the experiment. Also as a comparative standard, through no.1442 Japanese construction ministry notices about the building evacuation safety verification method, this study calculated smoke layer's dissent time and evacuation time. Then to compare with the former, the participants without an eye bandage joined a experiment once again. This study has understood how fire smoke effects on one's evacuation delay by analyzing residents' evacuation time to reach the staircase and movement route, however, in this study a toxic gas is not considered because it might threaten participants not to breathe.

Effect of Apartment Residents' Safety Awareness on Fire Response Performance: Focusing on the Moderating Effect of Control Offices' Control Competence (아파트 거주자의 안전의식이 화재대응성과에 미치는 영향 : 관리사무소의 관리역량 조절효과를 중심으로)

  • Kim, Jong-Nam;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.1
    • /
    • pp.43-53
    • /
    • 2020
  • The purpose of this study is to reduce the anxiety factors of fires by following evacuation tips in case of fire in an apartment household. This study analyzed the moderating effects of the control offices' competence in control on safety awareness and fire response. The study results were as follows. First, the residents and control staff's safety awareness had a positive effect on the fire response performance. This indicates that the higher the residents and control staff's safety awareness level, the higher the fire responsive performance. Second, the higher the control offices' control competence level, the better the apartment residents and control staff's safety awareness had a positive effect on the fire response performance. These results indicate that the higher the control office heads' leadership, the higher the apartment residents' housing satisfaction and that the more communicative the control office heads' attitude toward the residents, the better their attitude had a positive effect on the fire response performance. Lastly, the control offices' control competence was analyzed to have a moderating effects on the effect of the apartment residents and control staff's safety awareness level on the fire response performance. These results showed that the change in the model's R2 value showed an increasing trend in stages as the value increased more in the stage 2 than the stage 1 and even more in the stage 3 with the interaction terms of the moderating variables added. For this reason, the control offices' control competence which was a moderating variable was analyzed to have a moderating effect on the effect of residents and control staff's safety awareness level on the fire response performance.

A study for introduction plan of Evacuation Exit ladder in apartment (아파트에 있어서의 피난사다리 도입 방안에 관한 연구)

  • Kim, Tae-Hwan
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.11-16
    • /
    • 2008
  • The trend of constructing skyscraper has arisen to the offistel and apartment complex due to the lack of exploitable land and urbanization. But, the phenomenon of the multi-story buildings is different from the regular building because of the possibility of mass disaster in fire. Therefore, Analyzing and comparing our actual condition and Japanese, It is going to be suggested that the introduction of fire escape ladder for residents in emergency.

  • PDF