• Title/Summary/Keyword: Angulation

Search Result 295, Processing Time 0.022 seconds

A study on the geometric correction for the digital subtraction radiograph (디지털 공제방사선영상의 기하학적 보정에 관한 연구)

  • Lim Suk-Young;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.23-34
    • /
    • 2001
  • Purpose : To develop a new subtraction program for registering digital periapical images based on the correspondence of anatomic structures. Materials and Methods: The digital periapical images were obtained by Digora system with Rinn XCP equipment after translation of 1-16 mm, and rotation of 2-20° at the premolar and molar areas of the human dried mandible. The new subtraction program, NIH Image program and Emago/Advanced program were compared by the peak-signal-to noise ratio (PSNR). Results : The new subtraction program was superior to NIH Images program and Emagol Advanced program up to 16 mm translation and horizontal angulation up to 4°. Conclusion: The new subtraction program can be used for subtracting digital periapical images.

  • PDF

PRELIMINARY STUDY ON THE DESIGN OF IMPLANT ABUTMENT SCREW HEAD FOR RAPID FASTENING & LOOSENING (임플랜트 유지 나사 머리 홈의 설계가 나사를 푸는 시간에 미치는 영향에 관한 연구)

  • Lee, Jai-Bong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.40 no.2
    • /
    • pp.193-200
    • /
    • 2002
  • For the purpose of decreasing the chair time in implant cases, the time needed to loosening and fastening the screw must be shortened. Nowadays, the two typical designs of screw head are slot and hexa form. This study aimed at the shortening of loosening and fastening time by modifying the slot and hexa form. Total of twelve dentists participate in these experiments, four of them were experienced and eight of them were novice dentists. 1. There were many differences in the speeds of screw loosening and fastening between personal experiences. Experienced dentists are faster than novice dentists. 2. There were many differences in the speeds by angulation of the implant, by the conditions of the muscle tonicity. 3. Revised slot and hexa Heads show the slightly shortened time for acrew looseing and fastening.

Diagnostic Radiography of Premature Closure of Distal Growth Plate of Ulna in a Dog (개에서 척골의 원위 성장판 조기 폐쇄증에 대한 방사선학적 평가)

  • 송경진;이희천;이기창;권정국;최민철
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.403-405
    • /
    • 2003
  • A 11 month-old Shihtzu was referred to the Veterinary Medical Teaching Hospital, Seoul National University. Clinical signs of this patient were lameness, shortening limb, angular deformity, rotation of foot, subluxaion of elbow joint and restricted range of movement of left forelimb. For the evaluation of the abnormalities of left forelimb, radiographic examination was carried out. Radiographic findings were characteristics of premature closure of distal ulna such as closure of distal ulna growth plate and cranial bowing of radius. With radiographic signs and physical examination, it was diagnosed as premature closure of growth plate of the left forelimb. After osteotomy of the radius and ostectomy of the ulna, radiographic evaluation of limb about angulation of elbow joint was performed every 2-3 weeks for 3 months. In case of premature closure of distal growth plate of ulna, radiography was very useful for diagnositic method of premature closure of distal ulna and monitoring of healing process.

A STUDY OF CORRELATION ON THE SKELETAL FACTORS OF THE ANTERIOR OPEN BITE (전치부 개방교합의 골격요소간 상호연관성에 관한 연구)

  • Kim, Hyung-Il
    • The korean journal of orthodontics
    • /
    • v.15 no.2
    • /
    • pp.249-259
    • /
    • 1985
  • To analyze the skeletal characteristics of the open bite, the faces of normal occlusion and open bite were measured using a cephalogram. The factors which were greatly different from normal occlusion were selected. The effects of these factors on the incisal overbite and correlation on these factors were studied. The following results were obtained: 1. The 13 factors which comprised the characteristics of the open bite were obtained. (Table 5) 2. The cause and amount of the open bite were dependent on the skeletal angulation than skeletal length. 3. For determining the incisal overbite, most highly correlated single factor was the interincisal angle. 4. The correlation on the selected 13 factors which comprised the characteristics of the open bite was obtained. (Table 6) 5. The open bite was due to combination of various factors than due to single factor. (Table 3,4).

  • PDF

THE COMPARISON OF SHEAR STRENGTH AND BRACKET PLACEMENT BETWEEN BONDING TECHNIQUES (접착술식에 따른 전단강도 및 Bracket위치의 비교)

  • Pak, Yun-Kyong;Kook, Yoon-A;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.513-520
    • /
    • 1991
  • The purpose of this study was to compare the bracket placement and the shear bond strength of indirect-bonded brackets with those of direct-bonded ones. Forty eight extracted human teeth were collected and attached with brackets and tested on shear bond strength, using Instron. Fourteen patients from Wonkwang University Dental Hospital were selected for direct bonding of brackets and their teeth were measured on bracket angulation and bracket height. The obtained results were as follows: 1. The shear bond strengths of incisors were higher in direct-bonding,group, rather than in-direct-bonding group. But, the shear bond strength of premolars showed no significant differences between groups. 2. The bracket angulations of indirect-bonding group were preciser than those of direct-bonding group, especially in upper first premolars, lower lateral incisors, canines, premolars. 3. In bracket height, there were no significant differences between groups.

  • PDF

A MORPHOLOGIC STUDY ON STRAIGHT WIRE BRACKET FOR KOREAN (한국인의 Straight Wire Bracket의 형태에 관한 연구)

  • Park, Youngchel
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.481-493
    • /
    • 1991
  • The purpose of this study was to obtain the norm of the crown shape (tip, torque, in/out) and arch form, and to provide basic data for fabricating straight wire bracket and ideal arch wire for Korean. 100 subjects aged from 17 to 26 (50 females, 50 males) were selected with a normal occlusion. By measuring the size, angulation, inclination, arch width, facial prominance of the teeth and the molar offset, the following results were obtained. 1. Average, standard deviation, minimum, maximum of each measuring item for each teeth were obtained. 2. Intermolar width (${\underline{6}}$ to ${\underline{6}}$) of upper arch before occlusal surface cutting and intermolar width of upper arch (${\underline{6}}$ to ${\underline{6}}$, ${\underline{7}}$ to ${\underline{7}}$) after occlusal surface cutting showed statistical difference. There was no difference between sexes in any other measuring items. 3. Arch form and specification of straight wire bracket for Korean who have normal occlusion was obtained.

  • PDF

THE STUDY OF TECHNICAL FAILURE OF INTRAORAL ROENTGENOGRAPHY (국내 X-선 촬영술에 있어서 실패의 원인분석에 관한 연구)

  • Kang Yong Sang
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.7 no.1
    • /
    • pp.27-30
    • /
    • 1977
  • To insure accuracy in dental roentgenographs, it is important that the patient's head position and angulation of the x-ray tube. In 1907 Cieszynski applied the rule of isometry to dental radiography and established that in the production of an accurate image of a tooth, the central ray must be porjected perpendicularly to a plane bisecting angle formed by the longitudinal axis of the tooth and the film plane. Proper exposure of the film is a part of the production of a good dental radiograph, and correct processing also makes an essential contribution to the quality of the radiograph. The author analysed the failure of exposure and processing results, and recommended followings. 1. The patient head must be positioned that occlusal plane are parallel with the horizontal floor. 2. Central ray must be projected to the objective tooth and supporting structure and projected as perpendicularly to tooth axis and film surface as possible. 3. In processing, the temperature of the solution and the processing time must be correct.

  • PDF

LOCALIZATION TO THE PRODUCTION OF RADIOGRAPHIC IMAGE (X선상 형성과정에서 위치측정에 관하여)

  • Park T. W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.75-78
    • /
    • 1981
  • The diagnostic value of a intra oral film is related to projecting technic and interpretation. The intra-oral film is a single plane representation of a three dimensional object, therefore superimposition is inevitablly present. The purpose of this article is to show how foreign objects in the jaw may be localized. The author used double exposure technics, that are changed angulation of vertical or horizontal to one film. The obtained results are as fallow: 1. In the upper anterior region, the moving distance of the labially impacted reference object was greater than that of the palatally impacted one. 2. In the upper molar region, the moving distance of the mesiobuccal root apex was the greatest and that of palatal root apex was the shortest. 3. In the lower molar region, the change of the alveolar bone level in the buccal side was greater than that of lingual side.

  • PDF

Finite Element Method Modeling for Individual Malocclusions: Development and Application of the Basic Algorithm (유한요소법을 이용한 환자별 교정시스템 구축의 기초 알고리즘 개발과 적용)

  • Shin, Jung-Woog;Nahm, Dong-Seok;Kim, Tae-Woo;Lee, Sung Jae
    • The korean journal of orthodontics
    • /
    • v.27 no.5 s.64
    • /
    • pp.815-824
    • /
    • 1997
  • The purpose of this study is to develop the basic algorithm for the finite element method modeling of individual malocclusions. Usually, a great deal of time is spent in preprocessing. To reduce the time required, we developed a standardized procedure for measuring the position of each tooth and a program to automatically preprocess. The following procedures were carried to complete this study. 1. Twenty-eight teeth morphologies were constructed three-dimensionally for the finite element analysis and saved as separate files. 2. Standard brackets were attached so that the FA points coincide with the center of the brackets. 3. The study model of a patient was made. 4. Using the study model, the crown inclination, angulation, and the vertical distance from the tip of a tooth was measured by using specially designed tools. 5. The arch form was determined from a picture of the model with an image processing technique. 6. The measured data were input as a rotational matrix. 7. The program provides an output file containing the necessary information about the three-dimensional position of teeth, which is applicable to several finite element programs commonly used. The program for a basic algorithm was made with Turbo-C and the subsequent outfile was applied to ANSYS. This standardized model measuring procedure and the program reduce the time required, especially for preprocessing and can be applied to other malocclusions easily.

  • PDF

Reproducibility and accuracy of tooth size measurements obtained by the use of computer (컴퓨터를 이용한 치아크기 계측시 재현도와 정확도에 관한 연구)

  • Kim, Eun-Jeong;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.563-573
    • /
    • 1999
  • The purpose of this study was to evaluate the availability of computer system for the measurement of tooth size in the model analysis through the comparison of two measurements: One was to use a computer; and the other was to use vernier calipers. Twenty sets of casts were used, which showed a moderate degree of crowding and full eruption of all teeth. The mesio-distal width of 12 teeth from the left central incisor to the left first molar at each set of the casts were measured twice with vernier calipers and a computer respectively. This measurement was repeated two weeks later. First, for the reproducibility analysis, the two computer measurements were compared then the vernier calipers measurements were compared. Second, all the teeth were sepapated into the region of mesiodistal contact points and its width was measured by a micrometer to obtain standard measurements. For the accuracy analysis, these standard measurements were compared with the measurements from the dental casts using two methods. The difference between them was defined as the measurement error. To investigate the cause of measurement error, an examination was made for the presence and degree of contact point deviation on each tooth from the upper and lower occlusograms, and the mesio-distal angulation of each tooth was measured with TARG. Following results were obtained through statistical analysis. 1. In the analysis for reproducibility; the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in one out of twelve teeth. 2. In the analysis for accuracy; compared with the standard measurements, the measurements with vernier calipers showed significant differences in three out of twelve teeth while the computer measurements showed significant differences in two out of twelve teeth. 3. Compared with the standard measurements, the measurements with vernier calipers were apt to be larger at the upper first molar, and smaller at the lower first molar The computer measurements, however, were apt to be larger at both upper and lower first molars. 4. The measurements with vernier calipers showed the largest error at the lower first molar and the degree of error was variable according to the tooth while the difference of error was small in the computer measurements. 5. In the analysis for the correlation of the degree of measurement errors with the contact point deviation index and the mesio-distal crown angulation of each tooth, the measurements with vernier calipers did not show significant correlation while the measurements with computer showed slight Positive correlations. The results of this study indicate that a computer system may be useful for the measurement of tooth size in the model analysis.

  • PDF