• Title/Summary/Keyword: Angle measuring device

Search Result 112, Processing Time 0.028 seconds

Implementation and Application of the Control Surface Deflection Angle measuring device for UAV using Potentiometer (전위차계를 이용한 무인항공기 조종면 변위 측정 장치 구현 및 적용)

  • Kim, Ji-Chul;Choi, Il-Gyu;Gong, Sung-Chul;Cheon, Dong-Ik;Lee, Sangchul;Oh, Hwa-Suk;Kang, Min-young
    • Journal of Aerospace System Engineering
    • /
    • v.3 no.3
    • /
    • pp.13-16
    • /
    • 2009
  • Aircraft flight control surfaces which are one of the most important elements of safety allow a pilot to adjust and control the aircraft's flight attitude. This paper is described of the control surface deflection angle measuring device. Data analysis through ground test and flight test can provide reliability of this device using the present system. It is also shown that measuring system is capable of detecting failure of control surfaces.

  • PDF

Development of Force Measuring Device in Learning Wind Tunnel Used for Transportation Technology Class (수송 기술에 적합한 학습용 풍동의 힘 측정 장치 개발)

  • Choi, Jun-Seop;Lee, Sung-Gu
    • 대한공업교육학회지
    • /
    • v.32 no.1
    • /
    • pp.117-133
    • /
    • 2007
  • The purpose of this study was to develop the force measuring device of learning wind tunnel, teaching-learning materials in order to enhance understanding of flight principle and give interest about aviation technology in secondary school. The content of this study was consisted of the development and experiment of force measuring device for learning wind tunnel. The main results of this study were as follows: This device developed here is simple structure applying lever principle instead of the comparatively expensive load cell used in engineering college or a aviation research institute and so on. Measurement of lift and drag as well as the comparison experiment of a fluid resistance is possible with only one device developed here. The lift coefficient with angle of attack has shown the same tendency in both of theoretical and experimental values. And the stall phenomenon was found under the larger angle of attack of experimental rather than expected theoretical values. The drag coefficient with angle of attack has shown the same tendency in both of theoretical and experimental values. And drag coefficient the rate of increasement of the experimental values increased more gently than its theoretical values.

Development of a Digital Device for Measuring Soil Physical Properties (I) - Digital Shear Stress Sensor - (토양 물리성 측정을 위한 디지털 장치 개발(I) - 디지털 전단저항 측정장치 -)

  • Park, Jun-Gul;Lee, Kyou-Seung;Cho, Seung-Chan;Lee, Dong-Hoon;Chang, Young-Chang;Noh, Kwang-Mo
    • Journal of Biosystems Engineering
    • /
    • v.33 no.6
    • /
    • pp.416-422
    • /
    • 2008
  • This study was performed to design and construct a digital soil shear stress sensor in order to replace the conventional devices for measuring soil shear property. The developed digital shear stress measuring device can store measured data with GPS position information as a vector format into a computer. Based on the experiments at various field conditions, the measuring characteristic of the device was quite similar to that of a conventional device, SR-2 that has been a major tool to measure the soil shear property. It was concluded that the digital shear stress measuring device was an effective and comprehensive sensor for measuring soil shear property.

The effect of applying a head-weight device on cervical angle and pain of neck muscles

  • Kim, Jin-Hong;Kim, Jong-Gun;Do, Kwang-Sun;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.5 no.2
    • /
    • pp.101-105
    • /
    • 2016
  • Objective: The purpose of this study was to measure the change in pain threshold of levator scapular muscle, carniovertebral angle, and head position angle when applying a head-weight device on healthy adult. Design: Cross-sectional study. Methods: This study was conducted with 21 healthy adult male and female who voluntarily agreed to participate in this study after being informed of the purpose and method of this study. After measuring the cervical angle and pain threshold of levator scapular muscle, subject was instructed to walk for 5 minutes on a treadmill at a speed of less than 5 km/h while wearing after wearing head-weight device of 0.5 kg. Then, cervical spine angle and pain threshold of levator scapula muscle were re-measured. Measurement of cervical spine angle was conducted with photo by using the Bluebeam Revu software and the pain pressure thresholds (PPTs) were measured using an electronic algometer over potential trigger points on the body. Results: The results cervical angle showed a significant change, from $49.62^{\circ}$ to $52.10^{\circ}$ (p<0.05). PPT showed a significant change, from 30.71 to 36.89 (p<0.05). Conclusions: These findings suggest that applying head-weight device has a positive influence on increasing cervical angle and reducing pain when applied as a therapeutic intervention method of forward head posture.

Machining Tolerance of Various Implant Systems and their Components (치과용 임플란트 시스템의 기계적 가공오차에 관한 연구)

  • Kim, Hyeong-Seob;Kwon, Kung-Rock;Han, Jung-Suk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.1
    • /
    • pp.57-65
    • /
    • 2008
  • Purpose: Misfit of implant components was very important in terms of prosthodontics. they has been linked to prosthetic complications such as screw loosening and fracture. Although there are many results about rotational freedom or machining tolerance between fixture and abutments, the data about domestic implant systems are lacking. The aim of this in vitro study was to evaluate the rotational freedom of domestic external and internal connection implant systems between their fixtures/anlaogs and abutments comparing imported systems. Materials and Methods: Rotational freedom between abutments and fixtures/analogs was investigated by using digitalized rotational angle measuring device. (1) 1 domestic external connection system(Neobiotec) and 2 imported external connection systems(Nobel Biocare, Anthorgyr), (2) 1 domestic internal connection system(Dentium) and 4 imported external connection systems(Nobel Biocare, Anthorgyr, Straumann, Frident Dentsply), and (3) 1 domestic zirconia external connection abutment(ZirAce) were evaluated. Each group has 3 samples. Mean values for each group were analyzed. Results: The differences relative to rotational freedom between domestic and imported implant systems were observed but domestic external connection implant system showed about 2.67 degrees(in case of fixture) and internal connection system showed about 4.3 degrees(in case of fixture). Domestic zirconia abutment showed less than 3 degrees of rotational freedom in a situation where the abutment was connected to an implant fixture egardless of domestic or imported systems. Conclusion: Newly developed digitalized rotational angle measuring device has high measuring resolution. The rotational freedom of domestic implant systems were similar to imported implant systems.

Development of the Pointing Device using EOG (EOG를 이용한 포인팅 디바이스의 개발)

  • Park, Hyoung-Joon;Park, Jong-Hwan;Chun, Woo-Young
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1356-1363
    • /
    • 1999
  • In this paper, a new method for controlling the pointing device using EOG(electrooculogram) signal generated from eye movement was suggested. The basic idea of the method is to control the direction of pointer, as using the results of measuring each component of the horizontal EOG and the vertical EOG by angle of eye-gaze. As a practical example, pointing device controlling the personal computer's pointer is manufactured. The designed pointing device consists of pre-amplifier, A/D converter, serial transmission device and PC program. That is, first, the EOG is amplified by pre-amplifier. Secondly, the amplified EOG is digitized and transmitted to personal computer by PIC16C74A. Finally, the software for controlling the pointer on personal computer is programed. As the result, the measured horizontal EOG and vertical EOG by eye-gaze angle had high linearity; the correlation coefficients of the regression line were 0.998 and 0.996 respectively. And the developed pointing device is able to control the personal computer's pointer, and the average of the errors between the objective value and the observed value had 3.77% for horizontal axis and 5.85% for vertical axis. The pointing device developed in this study is able to control personal computer's pointer by subject's eye movement, that is, the user's intention. Furthermore, the algorithm of this study is applicable for many field, such as a new method remote control, a new wheelchair control and so forth.

  • PDF

Evaluation of Angle Optimization on Edge Test Device Setting in Modulation Transfer Function (변조전달함수 방법에서 엣지 장치 설정에 대한 각도 최적화 평가)

  • Min, Jung-Whan;Jeong, Hoi-Woun
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • This study was purpose to evaluation of Modulation Transfer Function in Measurements by using the International electrotechnical commission standard(IEC 62220-1) which were edge device each angle by using edge method. In this study was Aero(Konica, Japan) image receptor which is a indirect Flat panel detector(FPD) was used. The size of matrix 1994 × 2430 (14"× 17" inch) which performed 12 bit processing and pixel pitch is 175 ㎛. The results of shown as MTF measurements at IEC standard. The amount of data seemed reasonable and at an MTF value of 0.1 the spatial frequencies were 2.56 cycles/mm at an angle of 2.4°. MTF value of 0.5 the spatial frequencies were 1.32 cycles/mm at an angle of 2.4°. This study were to evaluate MTF by setting each angle 2.0°~2.8° degrees the most effective optimal edge angle and to suggest the quantitative methods of measuring by using IEC.

Torque Profile Measuring and Sensibility Evaluation of a Haptic Device (햅틱 장치의 프로파일 측정 및 감성 평가)

  • Jun, Cha-Soo;Choo, Heon-Seong;Park, Se-Hyung;Kim, Lae-Hyun;Shin, Sang-Kyun
    • Korean Journal of Computational Design and Engineering
    • /
    • v.15 no.3
    • /
    • pp.222-233
    • /
    • 2010
  • Developed in this research is a TP (tangible prototyping) system, which consists of two modules; (1) a virtual reality model to evaluate the functions and appearance of the product, and (2) a haptic device to emulate tactile and kinesthetic properties of mechanical dial knobs. As an example, a washing machine is modeled using a commercial CAD system and transformed in VRML and X3D formats. Some dynamic behaviors and kinematic characteristics are programmed using X3D script and Java. Various haptic behaviors of the dial are generated by modulating torque profile according to the rotation angle. A torque profile measuring system is developed to evaluate the behaviors of the haptic dial physically. Haptic sensibility evaluations are accomplished using the TP by semantic differential method.

Fiber-optic Ccurrent Sensor Using a Long-period Fiber Grating Inscribed on a High Birefringent Fiber (복굴절이 큰 광섬유에 제작된 장주기 광섬유 격자를 이용한 광섬유 전류 센서)

  • Lee, Yong-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.10
    • /
    • pp.1823-1825
    • /
    • 2007
  • Based on Faraday effect, the variation of current flowing through the conductor can be encoded as that of azimuth angle of light polarization propagating through the fiber coil wound onto the conductor. The amount of current can be obtained by measuring the variation of the light intensity transformed from that of the azimuth angle through a polarization analyzer. In this paper we propose a fiber-optic current sensor system that employs a fiber polarization analyzer as a sensor interrogation device. The fiber polarization analyzer was prepared by inscribing a long-period fiber grating on a high birefringent fiber. At the fixed wavelength of 1522.5 nm, the fabricated fiber device has the polarization extinction ratio of more than 25 dB. The measurement of large current up to 600 Arms was accomplished based on a simple fiber interrogation device and the measurement output of the sensor system showed a good linearity.

Failure Detection Filter for the Sensor and Actuator Failure in the Auto-Pilot System

  • Suh, Sang-Hyun
    • Journal of Hydrospace Technology
    • /
    • v.1 no.1
    • /
    • pp.75-88
    • /
    • 1995
  • Auto-Pilot System uses heading angle information via the position sensor and the rudder device to control the ship's direction. Most of the control logics are composed of the state estimation and control algorithms assuming that the measurement device and the actuator have no fault except the measurement noise. But such asumptions could bring the danger in real situation. For example, if the heading angle measuring device is out of order the control action based on those false position information could bring serious safety problem. In this study, the control system including improved method for processing the position information is applied to the Auto-Pilot System. To show the difference between general state estimator and F.D.F., BJDFs for the sensor and the actuator failure detection are designed and the performance are tested. And it is shown that bias error in sensor could be detected by state-augmented estimator. So the residual confined in the 2-dimension in the presence of the sensor failure could be unidirectional in output space and bias sensor error is much easier to be detected.

  • PDF