• Title/Summary/Keyword: Angiography, Digital Subtraction

Search Result 106, Processing Time 0.025 seconds

Role of Multislice Computerized Tomographic Angiography after Clip Placement in Aneurysm Patients Based on Comparison with Three Dimensional Digital Subtraction Angiography

  • Han, Myung-Hwan;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.2
    • /
    • pp.103-111
    • /
    • 2007
  • Objective : We evaluated the accuracy of multislice computerized tomographic angiography (MCTA) in the postoperative evaluation of clipped aneurysms by comparising it with three dimensional digital subtraction angiography (3D-DSA). Methods : Between May 2004 and September 2006, we included patients with ruptured cerebral aneurysm of the anterior circulation that was surgically clipped and evaluated by both postoperative MCTA and postoperative 3D-DSA. We measured the diagnostic performance and calculated the sensitivity and specificity of postoperative MCTA compared to 3D-DSA in the detection of aneurysm remnants. Results : A total of 11 neck remnants among the 92 clipped aneurysms (11.9%) were confirmed by 3D-DSA. According to Sindou's classification of aneurysm remnants, 8.7% of clipped aneurysms (8/92) had only neck remnant on 3D-DSA and 3.2% (3/92 aneurysms) had residuum of the neck and sac on 3D-DSA. There were 12 (13.04%) equivocal cases that were difficult to interpret based on the postoperative MCTA. The reasons for the equivocal cases included multiple clips (6 cases, 50.0%). beam-hardening effect (4 cases, 33.3%), motion artifact (1 case, 8.3%), fenestrated clip (1 case, 8.3%) and other combined causes. The sensitivity and specificity of the postoperative MCTA was 81.8% and 88.9%, respectively by ROC curve (p=0.000). Conclusion : MCTA is an accurate noninvasive imaging method used for the assessment of clipped aneurysms in the anterior circulation. If the image quality of postoperative MCTA is good quality and the patient has been treated with a single titanium clip, except a fenestrated clip, the absence of an aneurysm remnant can be diagnosed by MCTA alone and the need for postoperative DSA can be reduced in a large percentage of cases.

Applications of digital subtraction angiography in the management of penetrating injuries of the maxillofacial region: A case report

  • Fonseca, Vitor Jose;Chaves, Roberta Rayra Martins;Campos, Felipe Eduardo Baires;Lehman, Luiz Felipe;Moraes, Gustavo Meyer;Castro, Wagner Henriques
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.295-300
    • /
    • 2018
  • This report presents a clinical case of trauma due to assault with a knife, and describes the importance of using the correct imaging modality in cases of facial penetrating trauma involving the superficial and deep anatomical planes. Penetrating wounds in the maxillofacial region are rare and poorly reported, but can result in serious complications that are difficult to resolve and may compromise the patient's quality of life, especially when large blood vessels or other vital structures are involved. Thus, it is essential to determine the extent of the affected blood vessels and the proximity of the retained object to the anatomical structures. In this case, digital subtraction angiography was the imaging modality chosen. The use of appropriate imaging examinations allows a proper map of the surgical field, reducing the chances of vascular damage during the surgical procedure.

Rupture of De Novo Anterior Communicating Artery Aneurysm 8 Days after the Clipping of Ruptured Middle Cerebral Artery Aneurysm

  • Ha, Sung-Kon;Lim, Dong-Jun;Kim, Sang-Dae;Kim, Se-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.3
    • /
    • pp.236-238
    • /
    • 2013
  • Rapidly developed de novo aneurysm is very rare. We present a rapidly developed and ruptured de novo anterior communicating aneurysm 8 days after the rupture of another aneurysm. This de novo aneurysm was not apparent in the initial 3-dimensional computed tomography and digital subtraction angiography. We reviewed the literature and discussed possible mechanisms for the development of this de novo aneurysm.

Three-Dimensional Digital Subtraction Angiographic Evaluation of Aneurysm Remnants after Clip Placement

  • Ahn, Soon-Seob;Kim, Young-Don
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.3
    • /
    • pp.185-190
    • /
    • 2010
  • Objective : The aneurysm remnants rate was evaluated via three-dimensional digital subtraction angiography (3D-DSA) in the postoperative evaluation of clipped aneurysms. Methods : Data on surgically clipped aneurysms of anterior circulation obtained via postoperative 3D-DSA from February 2007 to March 2009 were gathered. The results of the postoperative 3D-DSA and of two-dimensional digital subtraction angiography (2D-DSA) for the detection of aneurysm remnants were compared, and an investigation was performed as to why 2D-DSA had missed some aneurysm remnants that were detected in the 3D-DSA. Various surgical factors that revealed aneurysm remnants in the 3D-DSA were also evaluated. Results : A total of 39 neck remnants of 202 clipped aneurysms (19.3%) were confirmed in 3D-DSA, and these were classified according to Sindou's classification of aneurysm remnants. Patients with only a neck remnant found in the 3D-DSA represented 17.3% (35/202 aneurysms) of the whole series, and those with a residuum of neck plus sac found in the 3D-DSA represented 1.9% (4/202 aneurysms). The causes of aneurysm remnants were no full visualization (14/39, 35.9%), parent and perforator artery protection (10/39, 25.6%), clip design problems (8/39, 20.5%), and broadnecked aneurysm (7/39, 17.9%). Conclusion : Patients with ${\leq}2$mm aneurysm remnants showed an increased risk of undetectable aneurysm remnants in the 2D-DSA. The most frequent location of the missed aneurysm in 2D-DSA was the anterior communicating artery. 3D-DSA showed more aneurysm remnants than what is indicated in the existing literature, the 2D-DSA.

Comparison of bone subtraction CT angiography with standard CT angiography for evaluating circle of Willis in normal dogs

  • Soyon An;Gunha Hwang;Rakhoon Kim;Tae Sung Hwang;Hee Chun Lee
    • Journal of Veterinary Science
    • /
    • v.24 no.5
    • /
    • pp.65.1-65.9
    • /
    • 2023
  • Background: Bone subtraction computed tomography angiography (BSCTA) is a useful alternative technique for improving visualization of vessels surrounded by skull bone. However, no studies have compared computed tomography angiography (CTA) and BSCTA for improving the visibility of canine cerebral blood vessels. Objectives: To evaluate the potential benefit of BSCTA for better delineation of brain arteries of the circle of Willis (CoW) in dogs by comparing BSCTA with non-subtraction computed tomography angiography (NSCTA). Methods: Brain CTA was performed for nine healthy beagle dogs using a bolus tracking method with saline flushing. A total dose of 600 mgI/kg of contrast agent with an iodine content of 370 mgI/mL was injected at a rate of 4 ml/s. Bone removal was achieved automatically by subtracting non-enhanced computed tomography (CT) data from contrast CT data. Five main intracranial arteries of the CoW were analyzed and graded on a scale of five for qualitative evaluation. Results: Scores of basilar artery, middle cerebral artery, and rostral cerebral artery in the BSCTA group were significantly higher than those in the NSCTA group (p = 0.001, p = 0.020, and p < 0.0001, respectively). Scores of rostral cerebellar artery (RcA) and caudal cerebral artery (CCA) did not differ significantly between the two groups. However, scores of RcA and CCA in the BSCTA group were higher than those in the NSCTA group. Conclusions: BSCTA improved visualization of intracranial arteries of the CoW with close contact to bone. Thus, it should be recommended as a routine scan method in dogs suspected of having brain vessel disease.

Usefulness of 3-Dimensional Gadolinium-enhanced MR Angiography for the Evaluation of Pedal Artery. : Comparison with digital subtraction angiography (족부혈관 평가에 있어서의 3차원 Gadolinium 조영증강 자기공명혈관조영술의 유용성 : 디지털 감산 혈관조영술과의 비교)

  • Ji, Youn-Sang;Lee, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.23-28
    • /
    • 2001
  • The purpose of this study is to compare the 3-dimensional MR angiography(MRA) with digital subtraction angiography(DSA) for the evaluation of pedal artery. MR angiography was performed using three-dimensional FISP acquisition before, and four sequential acquisitions after the injection of gadolinium(0.2 mmol/kg, 3 ml/sec). MRA was compared with DSA for a correct identification of the arterial segment. Out of 168 segments, 32 segmints were invisible in both MRA and DSA. At the level of ankle, 48 segments were visible in both examinations, and 18 segments were visible only in MRA. In the foot area, 34 segments were visible in MRA, but not in DSA. Three arterial segments were visible only in DSA. 3D MRA is comparable to DSA for the evaluation of pedal artery, thus it gives additional Information for the planning of treatment in lower extremity artery.

  • PDF

Digital Subtraction Technique for Intravenous X-ray Image System (컴퓨터 영상처리 방식을 이용한 정맥내 혈관 조영술 시스템 개발)

  • 이승지;이태수
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.109-116
    • /
    • 1981
  • The objective of this research is to develop the hardware and software systenls of the digital intravenous angiographic system. The system will be used in clinical diagnosis of cardiovascular and cerebrovascular diseases. By utilizing computer image processing technique and digital subtraction method, the system can decrease the patient's harzard and expenses in performing intravenous angiography, as compared with conventional angiograms of the arterial injection.

  • PDF

A Real Time Digital Subtraction Angiography (실시간 디지털 혈관조영술에 관한 연구)

  • 민병구;이태수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.3
    • /
    • pp.48-53
    • /
    • 1985
  • A real time digital subtraction angiographic system (RTDSA) was developed and utilized for diagnosis of the diseases related with the blood vessel conditions in 200 patients. In this paper, we present the system configurations and the real time processed images of the patients'abdominal, renal, femoral, and hepatic arteries.

  • PDF