• Title/Summary/Keyword: Analytical performance

Search Result 2,982, Processing Time 0.025 seconds

Performance Modeling of an EPC Information Service System

  • Kim, So-Jung;Kang, Yong-Shin;Son, Kyung-Won;Lee, Yong-Han;Rhee, Jong-Tae;Hong, Sung-Jo
    • Industrial Engineering and Management Systems
    • /
    • v.9 no.3
    • /
    • pp.285-293
    • /
    • 2010
  • To obtain visible and traceable information from the supply chain, HW/SW standards for the EPC global network, which process electronic product code (EPC) data read from Radio frequency identification (RFID) tags, are regarded as the de facto industry standard. Supply chain participants install information service systems and provide logistics information to partners by following the EPCglobal architecture framework. Although quality of service (QoS) is essential for providing dependable and scalable services as pointed out by Auto-ID Lab, only a few models for the performance analysis of QoS-related work have been developed in the context of EPC information service systems. Specifically, doing so allows alternative design choices to be tested in an easy and cost-effective manner and can highlight potential performance problems in designs long before any construction costs are incurred. Thus, in this study we construct a model of an EPC information service system for the purposes of performance analysis and designing a dependable system. We also develop a set of building blocks for analytical performance models. To illustrate how the model works, we determine the characteristics of an EPC information service system and then select a combination of these proven modeling concepts. We construct a performance model that considers the response time and shows how to derive meaningful performance values. Finally, we compare the analytical results to measurements of the EPC information service system.

Cyclic Loading Test and an Analytical Evaluation of the Modular System with Bracket-typed Fully Restrained Moment Connections (브래킷형 완전강접합 모듈러 시스템의 반복가력실험과 해석적 평가)

  • Park, Jae-Seong;Kang, Chang-Hoon;Shon, Su-Deok;Lee, Seung-Jae
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.19-28
    • /
    • 2018
  • Key factors that ensure competitiveness of modular unit include consistent high quality and connection condition that ensures high structural performance while minimizing the overall scale of the on-site process. However, it is difficult to evaluate the structural performance of the connection of modular unit, and its structural analysis and design method can be different depending on the connection to its development, which affects the seismic performance of its final design. In particular, securing the seismic performance is the key to designing modular systems of mid-to-high-rise structure. In this paper, therefore, the seismic performance of the modular system with bracket-typed fully restrained moment connections according to stiffness and the shapes of various connection members was evaluated through experimental and analytical methods. To verify the seismic performance, a cyclic loading test of the connection joint of the proposed modular system was conducted. As a result of this study, theoretical values and experimental results were compared with the initial stiffness, hysteresis behavior and maximum bending moment of the modular system. Also, the connection joint was modeled, using the commercial program ANSYS, which was then followed by finite element analysis of the system. According to the results of the experiment, the maximum resisting force of the proposed connection exceeded the theoretical parameters, which indicated that a rigid joint structural performance could be secured. These results almost satisfied the criteria for connection bending strength of special moment frame listed on KBC2016.

Design and Performance Evaluation of Low-Temperature Vacuum Blackbody System (저온-진공 흑체시스템의 설계 및 성능 평가)

  • Kim, Ghiseok;Chang, Ki Soo;Lee, Sang-Yong;Kim, Geon-Hee;Kim, Dong-Ik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.336-341
    • /
    • 2013
  • In this paper, the design concept of a low-temperature vacuum blackbody was described, and thermophysical model of the blackbody was numerically evaluated. Also the working performance of low-temperature vacuum blackbody was evaluated using infrared camera system. The blackbody system was constructed to operate under high-vacuum conditions ($2.67{\times}10^{-2}$ Pa) to reduce temperature uncertainty, which is caused by vapor condensation at low temperatures usually below 273 K. In addition, both heat sink and heat shield including cold shield were installed around radiator to prevent heat loss from the blackbody. Simplified mathematical model of blackbody radiator was analyzed using modified Stefan-Boltzmann's rule. The infrared radiant performance of the blackbody was evaluated using infrared camera. Based on the results of measurements, and simulation, temperature stability of the low-temperature vacuum blackbody demonstrated that the blackbody system can serve as a highly stable reference source for the calibration of an infrared optical system.

Quality Control System for Analytical Chemistry Laboratory of Pesticide Products (농약 이화학시험 분석기관 정도관리체계)

  • Chang, Hee-Ra;Lee, Joon-Yeob;Lee, Young-Ju;Kang, Hye-Rim;Kim, Chan-Sub;Kim, Kyun
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.529-544
    • /
    • 2011
  • Many international organizations, such as the International Organization for Standardization (ISO) and Collaborative International Pesticide Analytical Council (CIPAC), have published a guide to quality control requirements, proficiency testing and method validation for pesticide formulation. In general, proficiency testing is to determine the performance of individual laboratories from the comparison of test results and to monitor a laboratory's performance abilities. One of quality assurance (QA) scheme would be include the validation of analytical method that implies a performance characteristics, specificity, selectivity, linearity and so on. According to many international organizations, the quantification methods of active substance in formulated pesticide products are required to be reproducible, accurate and precise. This study was conducted to compare the international guidelines for the quality control, proficiency testing and method validation of analytical laboratories and to propose a general guidance for the establishment of quality control system in the analytical chemistry laboratories of pesticide formulation in domestic.

An Empirical Study of the Recovery Experiment in Clinical Chemistry (임상화학검사실에서 회수율 실험의 실증적 연구)

  • Chang, Sang-Wu;Lee, Sang-Gon;Song, Eun-Young;Park, Yong-Won;Park, Byong-Ok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.3
    • /
    • pp.184-188
    • /
    • 2006
  • The purpose of the recovery experiment in clinical chemistry is performed to estimate proportional systematic error. We must know all measurements have some error margin in measuring analytical performance. Proportional systematic error is the type of error whose magnitude increases as the concentration of analyte increases. This error is often caused by a substance in the sample matrix that reacts with the sought for analyte and therefore competes with the analytical reagent. Recovery experiments, therefore, are used rather selectively and do not have a high priority when another analytical method is available for comparison purposes. They may still be useful to help understand the nature of any bias revealed in the comparison of kit experiments. Recovery should be expressed as a percentage because the experimental objective is to estimate proportional systematic error, which is a percentage type of error. Good recovery is 100.0%. The difference between 100 and the observed recovery(in percent) is the proportional systematic error. We calculated the amount of analyte added by multiplying the concentration of the analyte added solution by the dilution factor(mL standard)/(mL standard + mL specimen) and took the difference between the sample with addition and the sample with dilution. When making judgments on method performance, the observed that the errors should be compared to the defined allowable error. The average recovery needs to be converted to proportional error(100%/Recovery) and then compared to an analytical quality requirement expressed in percent. The results of recovery experiments were total protein(101.4%), albumin(97.4%), total bilirubin(104%), alkaline phosphatase(89.1%), aspartate aminotransferase(102.8), alanine aminotransferase(103.2), gamma glutamyl transpeptidase(97.6%), creatine kinase(105.4%), lactate dehydrogenase(95.9%), creatinine(103.1%), blood urea nitrogen(102.9%), uric acid(106.4%), total cholesterol(108.5), triglycerides(89.6%), glucose(93%), amylase(109.8), calcium(102.8), inorganic phosphorus(106.3%). We then compared the observed error to the amount of error allowable for the test. There were no items beyond the CLIA criterion for acceptable performance.

  • PDF

Sloped rolling-type bearings designed with linearly variable damping force

  • Wang, Shiang-Jung;Sung, Yi-Lin;Hong, Jia-Xiang
    • Earthquakes and Structures
    • /
    • v.19 no.2
    • /
    • pp.129-144
    • /
    • 2020
  • In this study, the idea of damping force linearly proportional to horizontal isolation displacement is implemented into sloped rolling-type bearings in order to meet different seismic performance goals. In addition to experimentally demonstrating its practical feasibility, the previously developed analytical model is further modified to be capable of accurately predicting its hysteretic behavior. The numerical predictions by using the modified analytical model present a good match of the shaking table test results. Afterward, several sloped rolling-type bearings designed with linearly variable damping force are numerically compared with a bearing designed with conventional constant damping force. The initial friction damping force adopted in the former is designed to be smaller than the constant one adopted in the latter. The numerical comparison results indicate that when the horizontal isolation displacement does not exceed the designed turning point (or practically when subjected to minor or frequent earthquakes that seldom have a great displacement demand for seismic isolation), the linearly variable damping force design can exhibit a better acceleration control performance than the constant damping force design. In addition, the former, in general, advantages the re-centering performance over the latter. However, the maximum horizontal displacement response of the linearly variable damping force design, in general, is larger than that of the constant damping force design. It is particularly true when undergoing a horizontal isolation displacement response smaller than the designed turning point and designing a smaller value of initial friction damping force.

Assay of $\beta$-Galactosidase Using High Performance Liquid Chromatography (고속액체크로마토그래피를 이용한 유당분해효소의 활성도 측정)

  • Shin, Myung Gon;Chang, Pahn Shick;Min, Bong Kee;Kim, Sun Chang
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.465-469
    • /
    • 1992
  • An analytical procedure is presented for the quantitative determination of lactose, glucose, and galactose in the hydrolyzate of lactose by ${\beta}$-galactosidase with high-performance liquid chromatography. An Aminex HPX-87C column at $85^{\circ}C$ and refractive index detector were used to resolve lactose, glucose, and galactose in only 12 minutes with distilled and deionized water as a mobile phase. The validity of high-performance liquid chromatography as a method for the assay of ${\beta}$-galactosidase was supported by recovery experiments and comparision of results with those by ONPG method, a spectrophotometric assay. The procedure was appropriate for determination of sugars in the enzyme reaction mixture and could by applied to analysis of ${\beta}$-galactosidase activity.

  • PDF

Development and Assessment of New RT-qPCR Assay for Detection of HIV-1 Subtypes

  • Lim, Kwanhun;Park, Min;Lee, Min Ho;Woo, Hyun Jun;Kim, Jong-Bae
    • Biomedical Science Letters
    • /
    • v.22 no.3
    • /
    • pp.83-97
    • /
    • 2016
  • The measurement of viral load in HIV-1 infected patients is essential for the establishment of a therapeutic strategy. Several commercial assays have shown shortcomings in quantifying rare genotypes of HIV-1 such as minor groups of N and O. In this study, the HIV-1 RT-qPCR assay was developed. The primers and probe of HIV-1 were designed to target the pol gene and to increase the detection efficiency of various subtypes including group N and O. The HIV-1 quantitative RT-qPCR assay was assessed for its analytical performance and clinical evaluation. The LoD was determined to 33.9 IU/ml. The LoD of several subtypes including A, C, D, CRF_01AE, F, CRF_02AG, G and H, were determined to less than 40 IU/ml. The HIV-1 quantitative RT-qPCR assay was evaluated using the China National Reference Panel of HIV-1 RNA to determine the analytical performance. The results were all within the acceptable range. The clinical evaluation was performed at Hunan CDC in China. The clinical evaluation results were compared with those of the China domestic commercial kit. A significant correlation (fresh samples; $R^2=0.84$, P<0.001, frozen samples; $R^2=0.76$, P<0.001) between the two systems was observed for 64 fresh samples and 76 frozen samples with viral loads, and the Bland-Altman plot showed good agreement (98.4%, 96.1%, respectively). In conclusion, the HIV-1 quantitative RT-qPCR assay had comparable analytical performance with several commercial kits. The study provides basic data for the research of HIV-1 diagnosis and the development of P < HIV-1 molecular diagnostic assay.