• Title/Summary/Keyword: Analysis of Variance(ANOVA)

Search Result 1,525, Processing Time 0.03 seconds

In Vitro Evaluation of Shear Bond Strengths of Zirconia Cerami with Various Types of Cement after Thermocycling on Bovine Dentin Surface (지르코니아 표면 처리와 시멘트 종류에 따른 치면과의 전단 결합 강도 비교 연구)

  • Cho, Soo-Hyun;Cho, In-Ho;Lee, Jong-Hyuk;Nam, Ki-Young;Kim, Jong-Bae;Hwang, Sang-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.23 no.3
    • /
    • pp.249-257
    • /
    • 2007
  • State of problem : The use of zirconium oxide all-ceramic material provides several advantages, including a high flexural strength(>1000MPa) and desirable optical properties, such as shading adaptation to the basic shades and a reduction in the layer thickness. Along with the strength of the materials, the cementation technique is also important to the clinical success of a restoration. Nevertheless, little information is available on the effect of different surface treatments on the bonding of zirconium high-crystalline ceramics and resin luting agents. Purpose : The aim of this study was to test the effects of surface treatments of zirconium on shear bond strengths between bovine teeth and a zirconia ceramic and evaluate differences among cements Material and methods : 54 sound bovine teeth extracted within a 1 months, were used. They were frozen in distilled water. These were rinsed by tap water to confirm that no granulation tissues have left. These were kept refrigerated at $4^{\circ}C$ until tested. Each tooth was placed horizontally at a plastic cylinder (diameter 20mm), and embedded in epoxy resin. Teeth were sectioned with diamond burs to expose dentin and grinded with #600 silicon carbide paper. To make sure there was no enamel left, each was observed under an optical microscope. 54 prefabricated zirconium oxide ceramic copings(Lava, 3M ESPE, USA) were assigned into 3 groups ; control, airborne-abraded with $110{\mu}m$ $Al_2O_3$ and scratched with diamond burs at 4 directions. They were cemented with a seating force of 10 ㎏ per tooth, using resin luting cement(Panavia $F^{(R)}$), resin cement(Superbond $C&B^{(R)}$), and resin modified GI cement(Rely X $Luting^{(R)}$). Those were thermocycled at $5^{\circ}C$ and $55^{\circ}C$ for 5000 cycles with a 30 second dwell time, and then shear bond strength was determined in a universal test machine(Model 4200, Instron Co., Canton, USA). The crosshead speed was 1 mm/min. The result was analyzed with one-way analysis of variance(ANOVA) and the Tukey test at a significance level of P<0.05. Results : Superbond $C&B^{(R)}$ at scratching with diamond burs showed the highest shear bond strength than others (p<.05). For Panavia $F^{(R)}$, groups of scratching and sandblasting showed significantly higher shear bond strength than control group(p<.05). For Rely X $Luting^{(R)}$, only between scratching & control group, significantly different shear bond strength was observed(p<.05). Conclusion : Within the limitation of this study, Superbond $C&B^{(R)}$ showed clinically acceptable shear bond between bovine teeth & zirconia ceramics regardless of surface treatments. For the surface treatment, scratching increased shear bond strength. Increase of shear bond strength by sandblasting with $110{\mu}m$ $Al_2O_3$ was not statistically different.

The clinical study of acne patients (面疱 患者에 對한 臨床的 硏究)

  • Chae, Byeong-yoon
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.11 no.1
    • /
    • pp.251-268
    • /
    • 1998
  • 125 Cases of Acne were treated by Acupuncture and Herb-med treatment during a three months duration from April 1996 to February 1998 in Kyung Hee Univ. Department of Ophthal, Otolaryngology. College of Oriental Medicine. We have observed the cases and the results as follows: 1. The age of average was 24.55 age : 21.91 in males, 24.55 in females. and in these, the gulf between males and females were showed statically significant diference. In the age of onset, averag was 16.96 age and mode was 18 age and male's average was 16.96 age, minimun was 11 age, maximum 40 age and female's average was 20.14 age, minimun was 10 age, maximum 40 age. and these were showed statically significant diference between males and females. 2. In the distribution of season, winter was the most with $37.8\%$ of out patients, the rest was similar to difference of each other. but there was clear difference between males and females. 3. In the duration of history, the average was 5.10 years and male's average was 5.13 years. on the other hand female's was 5.09 years but there is no any significant difference have a resemblance with each other. 4. In blood type, O type was the most with $35.20\%$ and there was in the order of A type was $26.40\%\;B\;type\;was\;23.20\%,\;AB\;type\;was\;15.20\%$ but these were not significant difference by the chi-tend and analysis of variance with total cases, males and females. 5. In select of the preference food, patients of the prefer worm food was $42.40\%\;and\;cool\;food\;was\;38.40\%,\;tepid\;food\;was\;24\%$ but these were no significant difference by the chi-test and ANOVA of each other. 6. the state of pulse classified into 11 type and average was 7.2 times, maximum was 29 times with Hyun Sae, at the same time, the female's average was 6.73 times, maximum was 27 times and male's average was 1.5 times. The result of test with each other, these were showed statically significant difference as compared total cases with males but there were not females ones. 7. In the frequency of the major cause, oversensitiveness was the most with $34.93\%$. secondly there was in order of indigestion $30.82\%$ and menstrual irregularity and menstruation pain $23.28\%$. constipation $10.96\%$ and these showed statically significant difference as compared the females with males on the result of test for difference with each other. 8. In frequency of the symptoms, itching was the most with $31.97\%$ and there was in order of nodule $20.49\%$, pustule $18.85\%,\;papule\;15.58\%,\;flare\;13.12\%$ and also these showed statically significant difference as compared the females with males 9. for the Distribution of acne region, face was the most with $64.06\%$ and there was in order of back $14.29\%,\;upper-chest\;11.69\%,\;neck\;7.79\%$ and there was no significant difference as compared total cases with males and females. 10. Acne applied 30 prescription to 4 weeks and over and 20 weeks and over was $23.3\%$, 30 weeks and over was $16.67\%$ and average of administration duration were 4.2 weeks(male's average 5.78, maximum 96 weeks and female's average 3.85, maximum 23 weeks) maximum was 96 weeks, minimum was 1 week. 11. In the acupuncture treatment, $96.6\%$ applied to acupuncture and average was 5.44 times, maximum 46 times, minimum 1 time(male's average 4.64, female's 5.62) but these were not any significant differeence. 12. for the medication, author made a investigation and comparison between control group with treated group in order to observe for the therapeutic effect during the 1 month and 2, 3. From these results, we can see that acne was improved by the oriental treatment. in the 1 month, average of control group was 13.24 and treated group was 11.78. these showed statically significant decrease in P<0.02 as compared the treated group with control group. In the 2 months, average of control group was 13.43 and treated group was 9.03. these showed statically significant decrease in P<0.003 as compared the treated group with control group. In the 3 months, average of control group was 13.78 and treated group was 8.06. these showed statically significant decrease in P<0.008 as compared the treated group with control group.

  • PDF

Biological Activities of Calcium Polyphosphate (Calcium polyphosphate의 생물학적 활성도에 관한 연구)

  • Seol, Yang-Jo;Lee, Jae-Il;Lee, Yong-Moo;Lim, Yoon-Tak;Kim, Seok-Young;Ku, Young;Rhyu, In-Chul;Hahm, Byung-Do;Han, Soo-Boo;Choi, Sang-Mook;Chung, Chong-Pyoung
    • Journal of Periodontal and Implant Science
    • /
    • v.30 no.2
    • /
    • pp.213-231
    • /
    • 2000
  • 이 연구의 목적은 다공성의 CPP 내부에 쥐의 장골의 골수에서 유래된 세포를 접종하고 3차 원적으로 배양하여 CPP가 골 형성을 위한 조직공학의 지지체로 적용가능한가를 연구하는 것과 Calcium PolyPhosphate(CPP)의 돌연변이 유발성을 검사하는 것이다. 무수 ($Ca(H_2PO_4)$)를 condensation하여 무결정의 ($Ca(PO_3)$)를 얻고 이를 용융하고 냉각시킨 후 분쇄하여 Calcium polyphosphate(CPP) powder를 얻었다. 다공성의 CPP는 5% $SiO_2$를 첨가하여 sponge 형태로 $450-550{\mu}m$ 소공의 크기를 가지는 것과(CPP-45ppi) $200-300{\mu}m$의 소공의 크기를 가지는 것(CCP-60ppi) 2가지로 제작하였다. 각각의 CPP matrices는 $5mm{\times}5mm{\times}1mm$의 블록 형태로 만들었다. 체중 100g 내외의 백서에서 장골(femur, tibia)을 채취하여 백서의 장골 골수 세포를 분리하여 배양한 후 24well에 CPP block을 넣고 CPP block 당 $10^5$개의 배양한 세포를 접종하였다. 배양 1, 7, 14, 및 21 일째에 각 well에서 trypsin EDTA를 이용하여 2회 반복하여 cell을 분리하였고, 원심분리한 후 hemacytometer로 측정하였다. 또, 45ppi와 60ppi, 그 리 고 Tissue Culture Polystyrene(control group)에 접종, 배양된 세포들의 염기성 인산분해효소활성도를 배양 7, 14, 및 21 일째에 각각 측정하였다. 각 기간별로 배양된 세포-CPP 혼합체내에서 세포의 부착 및 증식과 형성된 조직의 3차원적 형태를 관찰하기 위하여 주사전자현미경하에서의 관찰하였다. CPP의 돌연변이 유발성 검사 (mutagenicity test)를 위해 hypoxanthine-guanine phosphoribosyl transferase(HPRT) assay를 하였다. NIH3T3 cell line과 CHO-K1 cell line으로 각각 $1000{\mu}g/m{\ell}$, $100{\mu}g/m{\ell}$, $10{\mu}g/m{\ell}$ 그리고 $1{\mu}g/m{\ell}$의 CPP 농도에서 측정하였다. 통계적 분석을 위해서 모든 측정은 각군당 4개체 이상 시험하였고, 각 측정값은 평균값${\pm}$표준편차로 나타내었다. 각 군간의 통계적 유의성 검정을 위해서 Analysis of variance(ANOVA)를 이용하였고 Tukey의 방법으로 사후분석을 실시하였다. 제작된 CPP matrices 소공들이 서로간에 연결이 잘 되어있는 형태였다. 두 가지로 제조된 CPP(45ppi와 60ppi) 모두에서 세포의 부착이 잘 일어났고, 부착된 세포의 분열도 잘 일어났다. 2 가지의 CPP 모두에서 7, 14, 21일째의 세포 수는 1일째에 비해 유의성 있게 증가하였다(P<0.01). 3차원적 구조인 Calcium PolyPhosphate에서 배양한 세포는 24well dish(tissue culture polystyrene)에서 평면적으로 배양한 대조군의 세포에서 보다 염기성 인산분해효소 (Alkaline Phosphatase)를 유의성 있게 높게 나타냈다. 주사전자현미경에서 세포-CPP 혼합체를 관찰한 결과, CPP block에 세포들이 잘부착되어 있었고, 시간이 지남에 따라 세포가 여러 층을 형성하면서 뭉치는 현상을 보였다. 또, HPRT assay 결과 , Calcium PolyPhosphate는 돌연변이 유발성을 보이지 않았다. 이상의 결과로 볼 때 CPP에는 세포부착이 잘 일어나고, 지지체 상에서 세포의 분열도 활발하게 일어나므로 골조직을 위한 조직공학의 우수한 지지체가 될 수 있을 것으로 사료된다.

  • PDF

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Rapid Statistical Optimization of Cultural Conditions for Mass Production of Carboxymethylcellulase by a Newly Isolated Marine Bacterium, Bacillus velezensis A-68 from Rice Hulls (통계학적 방법을 사용한 해양미생물 Bacillus velezensis A-68균주의 섬유소 분해효소 생산 조건 최적화)

  • Kim, Bo-Kyung;Kim, Hye-Jin;Lee, Jin-Woo
    • Journal of Life Science
    • /
    • v.23 no.6
    • /
    • pp.757-769
    • /
    • 2013
  • A microorganism producing carboxymethylcellulase (CMCase) was isolated from seawater, identified as Bacillus velezensis by analyses of 16S rDNA and partial sequences of the gyrA, and designated as B. velezensis A-68. The optimal conditions for production of CMCase by B. velezensis A-68 were established using response surface methodology (RSM). The optimal concentrations of rice hulls and yeast extract, and initial pH of the medium for cell growth were 60.2 g/l, 7.38 g/l, and 7.18, respectively, whereas those for production of CMCase were 50.0 g/l, 5.00 g/l, and 7.30. The analysis of variance (ANOVA) implied that the most significant factor for cell growth as well as production of CMCase was yeast extract. The optimal concentrations of $K_2HPO_4$, NaCl, $MgSO_4{\cdot}7H_2O$, and $(NH_4)_2SO_4$ in the medium for cell growth were 7.50, 1.00, 0.10, and 0.80 g/l, respectively, which were the same as those for production of CMCase. The optimal temperatures for cell growth and production of CMCase were 30 and $35^{\circ}C$, respectively. The maximal production of CMCase under optimized conditions was 83.8 U/ml, which was 3.3 times higher than that before optimization. In this study, rice hulls, agro-byproduct, were developed as a substrate for production of CMCase and time for production of CMCase was reduced to 3 days using a newly isolated marine bacterium.

The Effects of Different Types of Treatment on EPOC and Anti-Oxidant Systems after Horseback Riding Exercise (승마기구운동 후 서로 다른 회복처치가 초과산소섭취량 및 항산화력에 미치는 영향)

  • Kim, Cheol-Woo;Baek, Yeong-Ho;Kwak, Yi-Sub
    • Journal of Life Science
    • /
    • v.21 no.11
    • /
    • pp.1612-1618
    • /
    • 2011
  • The present study was undertaken to analyze the effects of different types of treatment on excess post exercise oxygen consumption (EPOC), flexibility, free radical and antioxidants in women using a horseback riding therapeutic device. Subjects were trained in regular horseback riding exercises for 12 weeks (3 times/wk). The effects of this exercise were examined by means of a single session of horseback riding that lasted for 30 min. 21 women were recruited from a public health center and divided into 3 groups (passive recovery group, passive+massage recovery group, and dynamic recovery group). 3 types of recovery patterns were determined after a single trial of horseback riding exercise. Their flexibility were determined pre-and post-training by Paired T test, and ANOVA were used to analyze the data. The results were as follows: Among the 3 groups, the dynamic recovery group showed the highest levels of EPOC compared to the other groups, and also showed higher levels of anti-oxidants, as did the passive+massage recovery group compared to the passive recovery group. Moreover, horseback riding exercise greatly increased flexibility in the women. In conclusion, regular horseback riding training is recommended to enhance the flexibility of women and dynamic recovery is recommended to enhance EPOC and anti-oxidants after a single bout of exercise. Further study is needed in this area.

COMPARATIVE STUDY OF BEHAVIOR AND COGNITIVE FUNCTION BY ADMINISTRATION OF METHYLPHENIDATE AND IMIPRAMINE IN ATTENTION DEFICIT-HYPERACTIVITY DISORDER (Methylphenidate와 Imipramine투여에 따른 주의력 결핍${\cdot}$과잉운동장애 환아의 행동 및 인지기능 변화에 대한 연구)

  • Ahn, D.H;Hong, K.E;Oh, K.J;Shin, M.S;Yoo, B.C;Chung, K.M
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.3 no.1
    • /
    • pp.26-45
    • /
    • 1992
  • This study presents the behavioral and cognitive changes by administration of methylphenidate(MPH) and imipramine(IMI) for the treatment of attention-deficit hyperactivity disorder(ADHD) in $5_{1/2}{\sim}12$ years old children referred to child psychiatric clinics. Behavioral changes are assessed with parent's and teacher's ratings. Drug effects on attention. short-term memory, and impulsivity are evaluated with psychological tests in laboratory. The changes were assessed twice in a 8-week periods. The data were analyzed seperately for 15 subjects each drug using repeated measured analysis of variance(ANOVA). The findings indicates that behavioral and cognitive impairments are improved by both drugs, but impulsivity is not. And MPH is superior to IMI on the improvement of attentional problem ; especially the findings indicates important differences between simple task and complex. perceptual-search task. These data confirm the effectiveness of MPH for treatment of ADHD, also raise questions regarding assessment method of attention and impulsivity as fell as importance of impulsivity in ADHD.

  • PDF

A study on the shear bond strength between Co-Cr denture base and relining materials (금속의치상과 의치이장재료 간의 결합력에 관한 연구)

  • Lee, Na-Young;Kim, Doo-Yong;Lee, Young-Soo;Park, Won-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.8-15
    • /
    • 2011
  • Purpose: This study evaluated the bonding strength of direct relining resin to Co-Cr denture base material according to surface treatment and immersion time. Materials and methods: In this study, Co-Cr alloy was used in hexagon shape. Each specimen was cut in flat surface, and sandblasted with $110\;{\mu}m$ $Al_2O_3$ for 1 minute. 54 specimens were divided into 3 groups; group A-control group, group B-applied with surface primer A, group C-applied with surface primer B. Self curing direct resin was used for this study. Each group was subdivided into another 3 groups according to the immersion time. After the wetting storage, shear bond strength of the specimens were measured with universal testing machine. The data were analyzed using two-way analysis of variance and Tukey post hoc method. Results: In experiment of sandblasting specimens, surface roughness of the alloy was the highest after 1 minute sandblasting. In experiment of testing shear bond strength, bonding strength was lowered on group B, C, A. There were significant differences between 3 groups. According to period, Bonding strength was the highest on 0 week storage group, and the weakest on 2 week storage group. But there were no significant differences between 3 periods. According to group and period, bonding strength of all group were lowered according to immersion time but there were no significant differences on group B and group C, but there was significant difference according to immersion time on group A. Conclusion: It is useful to sandblast and adopt metal primers when relining Co-Cr metal base dentures in chair-side.

Quality Assessment and Comparison of Several Radioimmunoassay Kits and Chemiluminescence Immunoassay Methods for Evaluating Serum Estradiol (혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교)

  • Choi, Sung Hee;Noh, Gyeong Woon;Kim, Jin Eui;Song, Yoo Sung;Paeng, Jin Chul;Kang, Keon Wook;Lee, Dong Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.1
    • /
    • pp.72-80
    • /
    • 2015
  • Purpose Serum estradiol ($E_2$) measurement is requested for diagnosing menstrual cycles, ovulation induction, infertility, and menopause. $E_2$ is measured using several methods and kits including radioimmunoassay (RIA) and chemiluminescece immunoassay (CLIA). The purpose of this study was to evaluate quality of these methods and to compare them with each other. Materials and Methods Seven radioimmunoassay kits and two CLIA methods were included in the analysis. Using standard samples and patient samples, intra-assay precision, inter-assay precision, correlation between other methods, sensitivity, and recovery rate were evaluated. Results For all tested kits and methods, coefficients of variance (CVs) of intra-assay precision test were 10.9~13.6% in low-level samples and less than 10% in medium and high-level samples. CVs of inter-assay precision test were 10.8~12.3% in low-level samples and less than 10% in medium and high-level samples with all tested kits and methods. Recovery rates were $92.7{\pm}12.4%$ for SIEMENS, $101.4{\pm}18.4%$ for DIAsource, $95.1{\pm}11.5%$ for AMP, $108.4{\pm}18.5%$ for BECKMAN COULTER, $104.2{\pm}13.5%$ for BECKMAN COULTER Ultra Sensitive, $101.3{\pm}11.6%$ for CIS Bio, and $93.1{\pm}13.2%$ for MP kits. Sensitivity was 7.5, 6.2, 5.7, 6.2, 5.3, 4.5, and 5.5 pg/mL for SIEMENS, DIAsource, AMP, BECKMAN COULTER, BECKMAN COULTER Ultra Sensitive, CIS Bio, and MP kits, respectively. The measurement by MP kit was slightly higher than those by other kits in low-level samples, and the measurement by E170 was slightly higher than those of other kits in medium and high-level samples. In the measurement of standard sample for external quality control, SIEMENS kit produced relatively lower values whereas E170, Architect, and MP kits produced relatively higher values compared with other kits. Conclusion All tested kits for $E_2$ measurement have satisfactory performance for clinical use. However, correlation between kits should be considered when test kits are to be changed, because some pairs of kits do not have correlations with each other.

  • PDF