• 제목/요약/키워드: Analysis method

검색결과 81,756건 처리시간 0.111초

Clinical Characteristics and Diagnostic Utility of Eosinophilic Pleural Effusion (호산구성 흉막유출의 임상상과 진단적 의의)

  • Roh, Gil-Hwan;Kang, Soo-Jung;Youn, Jong-Wook;Hwang, Jung-Hye;Ham, Hyoung-Suk;Kang, Eun-Hae;Lim, Young-Hee;An, Chang-Hyeok;Suh, Gee-Young;Chung, Man-Pyo;Kim, Ho-Joong;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • 제49권6호
    • /
    • pp.733-739
    • /
    • 2000
  • Background : Pleural eosinophilia is rare and commonly considered to be an indicator of good prognosis. The diagnostic significance of eosinophilic pleural effusions remains controversial despite a century of observation and discussion. This study was conducted to assess the prevalence of eosinophilia in 446 consecutive samples of pleural fluid, to review the cause of eosinophilic pleural effusion and to determine whether the presence of eosinophils increases the likehood of benign conditions. Method : A retrospective analysis was performed upon patients that underwent first thoracentesis due to pleural effusion between January 1999 and December 1999. Results : Eosinophilic pleural effusions were identified in 24 of the 446 patients (5.4%). Malignancy, parapneumonic effusion and tuberculosis were determined the major causes of pleural effusion (80.6%). Malignancy was diagnosed as frequently in eosinophilic effusions as in non-eosinophilic effusions (54.2% vs 50.5%, p=0.725). No difference was found in the prevalence of eosinophilic and non-eosinophilic effusion according to the etiology. The mean blood eosinophil ratio in patients with eosinophilic pleural effusion was 5.4% and no significant correlation existed between the blood and pleural eosinophilic count. Conclusion : Pleural eosinophilia is not helpful for differentiating benign and malignant etiology and is not related with bood eosinophilia or repeated tapping.

  • PDF

The Clinical Study of Hemoptysis in Lung Disease (객혈을 주소로 입원한 환자의 임상적 고찰)

  • Lee, Hyang-Ju;Um, Hye-Suk;Kim, Jung-Tae;Cho, Dong-Ill;Rhu, Nam-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • 제49권6호
    • /
    • pp.760-773
    • /
    • 2000
  • Background : Hemoptysis is a common clinical symptom responsible for 11% of admission to the hospital chest service. In KOREA pulmonary tuberculosis is still the most common cause of hemoptysis and the incidence of hemoptysis due to neoplasia has increased. Bronchoscopy and high resonance CT are essential for diagnosis of the cause of hemoptysis. We studied the causes, diagnostic tools and treament treatment of hemoptysis Methods : We conducted a retrospective analysis of clinical profiles, radiologic and bronchoscopy findings and treatments of hemoptysis for 220 patients who were admitted to our hospital with hemoptysis between 1994 and 1998. Results : The mean age at diagnosis was 49.3 years and male to female ratio was 2.1 : 1. The main causes were active pulmonary pulmonary tuberculosis in 72 cases(32.7%), inactive pulmonary tuberculosis with sequlae in 69 cases(31.4%) lung cancer in 43 cases(19.5%), bronchiectasis in 10 cases(4.5%), and chronic bronchitis in 10 cases(4.5%). The mean amount of hemoptysis for 24hrs was 120cc. The mean duration of bleeding was 25 days. The number of cases with a past history of pulmonary tuberculosis were 128 cases, in which 24 were relapsed tuberculosis cases, 25 chronic tuberculosis cases, 69 inactive tuberculosis cases, and 10 lung cancer cases. High resonance CT was the most useful method for structural etiologic evaluation of hemoptysis developed in patients with inactive tuberculosis, bronchiectasis and aspergilloma. Sputum study and bronchofiberscopy were the confirmative diagnostic tools for active pulmonary tuberculosis and lung cancer. The treatments of hemoptysis medical in 152 cases(71.7%), bronchial arteη embolization in 39 cases(17.8%), and operation in 9 cases(4.0%). The mean following up duration was 22.4 months. The overall outcomes of hemoptysis were controlled in 77 cases(43.5%), rebleeding in 100 cases (56.5%) and expired in 9 cases (4.0%). The outcomes of hemoptysis in pulmonary tuberculosis were controlled in 21.6%, rebleeding in 78.4%, and expire in 14.7%. Conculsion : The most common cause of hemoptysis was related with pulmonary tuberculosis. HRCT was an important diagnostic tool in AFB smear negative active pulmonary tuberculosis and inactive tuberculosis with sequelae. Early, proper management of pulmonary tuberculosis is important for prevention of hemoptysis in Korea.

  • PDF

Ser326Cys Polymorphism of hOGG1 Gene and Risk of Primary Lung Cancer in Koreans (한국인에서 hOGG1 유전자의 Ser326Cys 다형성과 원발성 폐암의 위험도)

  • Chae, Sang-Chul;Kim, Kyung-Rock;Joo, So-Young;Lee, Su-Yean;Kang, Kyung-Hee;Jeon, Kyung-Neoyh;Cha, Seung-Ick;Kim, Chang-Ho;Jung, Tae-Hoon;Park, Jae-Yang
    • Tuberculosis and Respiratory Diseases
    • /
    • 제52권1호
    • /
    • pp.5-13
    • /
    • 2002
  • Background: DNA repair plays a crucial role in protecting the genome from cancer-causing agents. Therefore, a reduced DNA repair capacity can increase the susceptibility to cancer. The human OGG1 (hOGG1) gene encodes DNA glycosylase/apurinic lyase and excise 8-hydroxyguanine, one of the major premutagenic DNA lesions, which is produced by oxygen radical forming agents including smoking. Recently several polymorphisms in the hOGG1 gene were identified, and it is possible that these polymorphism') may affect the DNA repair capacity and thus modulate cancer susceptibility. The relationship between the codon 326 polymorphism (Ser to Cys) in the hOGG1 gene and lung cancer risk was investigated. Materials and Method: The Ser326Cys genotypes were determined using PCR-RFLP analysis in 299 primary lung cancer patients and 186 healthy controls who were frequency (case:control=3:2) matched according to age and sex. Result: The frequencies of the Ser326Cys genotypes (Ser/Ser, Ser/Cys and Cys/Cys) among cases (23.4%, 51.8%, and 24.7%, respectively) were not significantly different from those among the controls (22.6%,52.1% and 25.3%, respectively). When the analyses were stratified according to age, sex, smoking status and packyears of smoking, no significant association between this polymorphism and lung cancer risk was found. Moreover, the Ser326Cys genotype showed no apparent relationship with any of the histological types of lung cancer. Conclusion: These result suggest that the hOGG1 Ser326Cys polymorphism is not a major contributor to individual lung cancer susceptibility in Koreans.

The Comorbidity of Periodic Limb Movements Disorder in Patients with Sleep-Related Breathing Disorder (수면관련 호흡장애 환자에서의 수면중 주기성 사지운동장애의 동반이환율)

  • Yang, Chang-Kook;Son, Choon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권5호
    • /
    • pp.1039-1046
    • /
    • 1998
  • Background: Sleep-related breathing disorders(SRBD) and periodic leg movements disorder(PLMD) are both common, and are considered as separate sleep disorders. However, both disorders show high comorbidity. SRBD and PLMD can result in excessive daytime sleepiness and insomnia due to frequent sleep fragmentation. So, it is very important to consider the presence of PLMD, when we are dealing with the diagnosis and management of SRBD. The objectives of this study were to determine the incidence of PLMD in patients with SRBD, and to describe any differences between patients with and without PLMD. Method: The authors reviewed the sleep recordings of 106 patients with a final diagnosis of SRBD(obstructive sleep apnea or upper airway resistance syndrome), who underwent full nocturnal polysomnography, including the monitoring of the anterior tibialis electromyogram. All sleep records were recorded and scored using the standard criteria. The data was analyzed by the student t-test. Result: 106 patients(M=76, F=30) were included in the analysis. Data revealed a mean age of $49.5{\pm}13.6$ years, a respiratory disturbance index(RDI) of $22.3{\pm}25.4$/hour sleep, a lowest oxygen saturation of $84.9{\pm}11.3%$, a maximal esophageal pressure of $-41.0{\pm}19.1cmH_2O$, and PLM index(PLMI) of $13.1{\pm}22.4$movements/hour sleep. Forty four percent(47 of 106 patients) had a PLMI of greater than 5 on this study. The mean age of the patients with PLMD was significantly higher than that of the patients without PLMD(p<0.005). Female patients with SRBD accompanied more PLMD(p<0.05). The apnea index of the patients with PLMD was significantly lower than that of the patients without PLMD(p<0.01). The percentage of stage 1 sleep in the patients with PLMD was significantly lower than that of the patients without PLMD(p<0.05). Conclusion: The prevalence of PLMD in the patients with SRBD was high at 44.3%. The patients with PLMD were older and had more high RDI in comparison to the patients without PLMD, which was consistent with previous findings. The authors recommend that more careful consideration of PLMD is required when diagnosing and treating SRBD.

  • PDF

Clinical Observational study of Pulmonary Tuberculosis for admitted patients at a National Tuberculosis Hospital - Comparison with the previous results in 1995 - (일개 국립결핵병원에 입원치료를 받은 폐결핵환자의 임상양태에 관한 연구 - 1995년과 2002년 비교연구 -)

  • Park, Seung-Kyu;Lee, In-Hee;Kim, Byoung-Ju
    • Tuberculosis and Respiratory Diseases
    • /
    • 제58권4호
    • /
    • pp.392-398
    • /
    • 2005
  • Background : The last national tuberculosis survey was carried out in 1995. In 2000, the KTBS(Korean Tuberculosis Surveillance System) replaced a previous national survey. However, the KTBS does not show some of the important epidemiological indexes such as the prevalence of positive tuberculosis or the drug resistance rate. The aim of this study was to compare the clinical features of pulmonary tuberculosis patients admitted to a national tuberculosis hospital in 1995 and 2002. From this study, the authors expect to estimate the trend of the clinical features of tuberculosis in Korea even though it can not represent the Korean tuberculosis situation as a whole. Method : A cross sectional analysis of the clinical features for 331 pulmonary tuberculosis in-patients admitted to the National Masan Tuberculosis Hospital as of Dec. 2002, was carried out and these results were compared with those reported in 1995. Results : In comparison with the data reported in 1995, the mean age was increased by 3.6 years ($44.1{\pm}14.6$ vs $47.7{\pm}16.4$, p<0.01). The number of past tuberculosis history and used anti-tuberculous drugs prior to admission decreased from $2.0{\pm}1.7$ and $6.1{\pm}2.3$ to $1.7{\pm}1.8$ and $4.6{\pm}3.6$(p<0.05, p<0.001), respectively. While the resistance rate for anti-tuberculous drugs was similar (81.0% vs 77.6%), the initial resistance rate(10.5% vs 21.4%) and initial MDR rate(2.4% vs 16.5%) increased significantly(p=0.012, p=0.001, respectively). In 1995, the public health communities were in charge of approximately 65% of newly diagnosed tuberculosis cases, but this reduced to 40.5% in 2002(p<0.001). Conclusion : The existing national TB program (NTP) needs to be revised and strengthened in order to cope with the unfavorably changing situation of the domestic TB problem because the number of TB patients has not decreased and the initial resistance rate has increased greatly. Furthermore, the public and private sectors should cooperate each other to control the TB problem effectively because the private sector is now managing more than half of the TB patients.

Risk Factors of Extubation Failure and Analysis of Cuff Leak Test as a Predictor for Postextubation Stridor (발관 실패의 위험 인자 및 발관 후 천음과 재삽관의 예측에 있어 Cuff Leak Test 의 유용성과 의미 분석)

  • Lim, Seong Yong;Suh, Gee Young;Kyung, Sun Yong;An, Chang Hyeok;Park, Jung Woong;Lee, Sang Pyo;Jeong, Sung Hwan;Ham, Hyoung Suk;Ahn, Young Mee;Lim, Si Young;Koh, Won Jung;Chung, Man Pyo;Kim, Ho Joong;Kwon, O Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • 제61권1호
    • /
    • pp.34-40
    • /
    • 2006
  • Background: Extubation failure was associated with poor prognosis and high hospital mortality. Cuff leak test (CLT) has been proposed as a relatively simple method for detecting laryngeal obstruction that predispose toward postextubation stridor (PES) and reintubation. We examined the risk factors of extubation failure and evaluated the usefulness and limitation of CLT for predicting PES and reintubation. Methods: Thirty-four consecutive patients intubated more than 24 hours were examined. The subjects were evaluated daily for extubation readiness, and CLT was performed prior to extubation. Several parameters in the extubation success and failure group were compared. The accuracy and limitation of CLT were evaluated after choosing the thresholds values of the cuff leak volume (CLV) and percentage (CLP). Results: Of the 34 patients studied, 6 (17.6%) developed extubation failure and 3 (8.8%) were accompanied by PES. The patients who had extubation failure were more likely to have a longer duration of intubation and more severe illness. The patients who developed PES had a smaller cuff leak than the others: according to the CLV ($22.5{\pm}23.8$ vs $233.3{\pm}147.1ml$, p=0.020) or CLP ($6.2{\pm}7.3$ vs $44.3{\pm}24.7%$, p=0.013). The best cut off values for the CLV and CLP were 50ml and 14.7%, respectively. The sensitivity, negative predictive value, and specificity of CLT were relatively high, but the positive predictive value was low. Conclusion: The likelihood of developing extubation failure increases with increasing severity of illness and duration of intubation. A low CLV or CLP (<50ml or 14.7%) is useful in identifying patients at risk of PES, but the CLT is not an absolute predictor and should not be used an indicator for delaying extubation.

The Effect of Three Surface Sealants on Microleakage of Class V Composite Resin Restorations (복합레진으로 수복한 5급 와동의 미세누출에 대한 3종의 레진 표면 전색제의 효과)

  • Lee, Won-Cheol;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제47권2호
    • /
    • pp.182-190
    • /
    • 2009
  • Statement of problem: Microleakage at the occlusal and gingival margin of Class V cavities restored with composite resin has traditionally been considered an obstacle to successful restoration. Purpose: The aim of this study was to assess the effectiveness of three different surface sealants(Fortify, Permaseal and Biscover LV) on the marginal sealing of Class V light-activated composite resin restorations(Z250). Material and methods: Forty noncarious human premolars and molars extracted within a three-month period were selected. Class V cavities with the occlusal margin in enamel and gingival margin in cementum were prepared in both buccal and lingual surfaces. The teeth, randomly assigned in four groups with twenty cavities in each group, were restored with composite resin after applying an adhesive system(Clearfil SE bond). After the finishing and polishing procedures, the restorations were covered with a specific surface sealants, except for the control samples, which were not sealed. After placing restorations, the specimens were thermocycled, and immersed in a 2% methylene blue solution for twenty four hours and sectioned longitudinally. The marginal microleakage was evaluated at the occlusal and gingival interfaces using a microscope and compared among the four groups using ANOVA test and Wilcoxon Rank-Sum test($\alpha$=0.05). Results: Statistical analysis showed that there was significantly less leakage when the surface sealants were used than there was in control group(P<.05). There were no significant differences of microleakage at occlusal and gingival margins among groups. There were no significant differences between microleakage of occlusal and gingival margins in each group. Fortify was not statistically different from control group at the gingival margin(P>.05). Conclusion: Application of surface sealants was an effective method of surface coating in reducing microleakage at occlusal and gingival margins of Class V composite resin restorations. However, it is certain that some microleakage still occurred despite the application of surface sealants, especially gingival margins.

Polishing characteristics of polyetherketoneketone on Candida albicans adhesion (Polyetherketoneketone의 연마 특성이 Candida albicans의 부착에 미치는 영향)

  • Kim, Hyunyoung;Lee, Jonghyuk;Lee, Sung-Hoon;Baek, Dongheon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제58권3호
    • /
    • pp.207-216
    • /
    • 2020
  • Purpose: To compare the polishing characteristics and their influence on Candida albicans adhesion to the recently introduced polyetherketoneketone (PEKK) and the conventional polymethylmethacrylate (PMMA) denture resin material. Materials and methods: Specimens from PEKK (Group E) and PMMA (Group M) were made in dimensions of 8 mm in diameter and 2 mm in thickness. The specimens were further divided into sub-groups according to the extent of polishing (ER, MR: rough; EP, MP: polished, N = 12 each). The specimens were polished using polishing machine and SiC foil. ER and MR group specimens were polished with 600 grit SiC foil only. EP and MP groups were further polished with 800, 1,000, 1,200 grit SiC foils sequentially. To measure the surface roughness values (Sa) of specimens, atomic force microscope (AFM) was used and scanning electron microscope (SEM) observation under 1,000, and 20,000 magnifications was performed to investigate surface topography. The polished specimens were soaked in C. albicans suspension for 2 hours with shaking to promote adhesion. The attached C. albicans were detached from the surface with 10 times of pipetting. The suspension of detached C. albicans was performed by serial dilution to 103 times, and the diluted suspensions were inoculated on Sabouraud dextrose agar plates using spread plate method. After incubating the plate for 48 hours, colony forming unit (CFU)/plate of C. albicans was counted. Statistical analysis was performed using one-way ANOVA and Tukey HSD test to confirm significant difference between the groups (α=.05). Results: Average Sa value was significantly higher in MR group compared to other groups (P<.05), meaning that additional polishing steps reduced surface roughness effectively only in the PMMA specimens. There was no significant difference in Sa values between MP and EP groups. In SEM images, PEKK specimens showed numerous spikes of abraded material protruding from the surface and this phenomenon was more significant in EP group. The mean CFU/plate value was the highest in EP group and this was significant when it was compared to MP group (P<.05) which was the lowest. Conclusion: Polishing PEKK using serial SiC abrasive foil may result in higher adhesion of C. albicans. In clinic, this should be considered carefully.

A Study on the Influence of Finishing and Polishing Methods on the Gap between Denture Base Resin and Soft Liner (의치의 마무리와 연마법이 의치상 레진과 연성 이장재 간의 공극에 미치는 영향에 관한 연구)

  • Jung, Seung-Hwan;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제24권4호
    • /
    • pp.325-335
    • /
    • 2008
  • The junction between resilient denture liner and the denture base is difficult to finish and polish due to difference of the physical property of the materials. Gaps tend to be formed during finishing and polishing procedures. The purpose of this study was measuring the width of junctional gap between $Molloplast-B^{(R)}$ and denture base material after finishing and polishing procedure, and evaluating the effect of method and direction on gap width. $Molloplast-B^{(R)}$ was processed (according to the manufacturer's instruction) against Lucitone $199^{(R)}$ acrylic resin. 50 specimens were fabricated with a raised center section. All of specimens were examined and photographed with a stereoscopic microscope(x120), and the largest gap along the junction of $Molloplast-B^{(R)}$ and acrylic resin on each specimen was measured. One-way analysis of variance(ANOVA) and independent t-test at 95% confidence level were used to analyze the data and to compare groups. The results of this study were as follows. In comparison with finishing tools, the gap width was the largest in $Molloplast^{(R)}$-Cutter and the smallest in FSQ-cross cut bur. There was statistically significant difference between FSQ-cross cut bur and $Molloplast^{(R)}$-Cutter(p<0.05). There was no significant difference in gap width between the direction of polishing. The mean value of gap width was the smallest in case of no polishing, and the largest in case of polishing with pumice & tin oxide. There was statistically significant difference between pumice and pumice & tin oxide. From the results, it is concluded that the use of $Molloplast^{(R)}$-Cutter in clinic need serious consideration even though it has good cutting ability. Further careful study is needed for finishing and polishing methods for decreasing gap width in junction of two materials.

The Effect of Packing Method of Relining Material on the Flexural Strength of Denture Base Resin (첨상용 레진의 성형법이 의치상의 굴곡강도에 미치는 영향)

  • Kim, Min-Chul;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제27권2호
    • /
    • pp.197-207
    • /
    • 2011
  • The study aimed at examining how different reline resins affect flexural strength and flexural modulus of denture base. A total of 80 specimens ($64{\times}10{\times}3.3$ mm, according to ISO 1567:1999) of heat-polymerized resin, 40 specimens for (Lucitone199(Dentsply Int., NewYork, USA), SR Ivocap(Ivoclar AG, Schaan, Liechtenstein)) respectively, were polymerized according to the manufacturer's instructions and divided into eight groups(n = 10). Control group specimens remained intact. Specimens in the other groups were abraded on both sides to 2 mm thickness, and were relined in 1.3 mm thickness with 3 types of resins (Lucitone199(Dentsply), SR Ivocap(Ivoclar), and Rebase II(Tokuyama Co., Ltd, Tokyo, Japan)). All specimens were preserved in distilled water at $37^{\circ}C$ for 50 hours, and then were subjected to flexural strength testing in a universal testing machine using 3-point loading. A crosshead speed of 5 mm/min was used, and the distance between the supports was 50 mm. Data analyses included one-way analysis of variance(ANOVA) and the Tukey Honestly Significant Difference test (p=.05). Both heat-polymerized resin groups and auto-polymerized resin groups showed statistically low flexural strength and flexural modulus than control groups. Specimens relined with Lucitone 199 showed significantly higher flexural strength and flexural modulus than those relined with SR-Ivocap. Specimens relined with auto-polymerized resin showed significantly lower flexural strength and flexural modulus than those relined with heat-polymerized resin. Relining with heat-polymerized resins showed superior mechanical properties to relining with an auto-polymerized resin. Relining with the same heat-polymerized resin as the denture base does not affect mechanical properties of a denture. Lucitone199 using a compression-mould technique resulted in the highest flexural strength.