• Title/Summary/Keyword: Analog digital converter

Search Result 588, Processing Time 0.028 seconds

A CMOS Duty Cycle Corrector Using Dynamic Frequency Scaling for Coarse and Fine Tuning Adjustment (코오스와 파인 조정을 위한 다이나믹 주파수 스케일링 기법을 사용하는 CMOS 듀티 사이클 보정 회로)

  • Han, Sangwoo;Kim, Jongsun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.142-147
    • /
    • 2012
  • This paper presents a mixed-mode CMOS duty-cycle corrector (DCC) circuit that has a dynamic frequency scaling (DFS) counter and coarse and fine tuning adjustments. A higher duty-cycle correction accuracy and smaller jitter have been achieved by utilizing the DFS counter that reduces the bit-switching glitch effect of a digital to analog converter (DAC). The proposed circuit has been designed using a 0.18-${\mu}m$ CMOS process. The measured duty cycle error is less than ${\pm}1.1%$ for a wide input duty-cycle range of 25-75% over a wide freqeuncy range of 0.5-1.5 GHz.

Design and Implementation of the Diseases Diagnosis System Using The Cantilever Micro-Arrays (박막 캔틸레버 어레이 센서를 이용한 질병 진단기 설계 및 구현)

  • Jung, Seung-Pyo;Choi, Jun-Kyu;Lee, Jung-Hoon;Park, Ju-Sung
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.52-57
    • /
    • 2015
  • The disease diagnosis system has been developed using the thin nitride(Si3N4) cantilever arrays which can measure the difference of capacitances between sensor and reference. The system consists of 32-bits RISC(Reduced Instruction Set Computer), RAM/Flash, bus, communication IP's, ADC(Analog Digital Converter) board, and LCD display. The marker selection method, which give us the good accuracy from reasonal numbers of markers, is suggested. The developed system has the resolution under 1fF and can detect 10nM concentration of Thrombin.

A 10-bit 100Msample/s Pipeline ADC with 70dBc SFDR (SFDR 70dBc의 성능을 제공하는 10비트 100MS/s 파이프라인 ADC 설계)

  • Yeo, Seon-Mi;Moon, Young-Joo;Park, Kyong-Tae;Roh, Hyoung-Hwan;Park, Jun-Seok;Oh, Ha-Ryoung;Seong, Yeong-Rak;Jung, Myeong-Sub
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1444-1445
    • /
    • 2008
  • 최근 Wireless Local Area Network(WLAN), Wide-band Code Division Multiple Access(WCDMA), CDMA2000, Bluetooth 등 다양한 모바일 통신 시스템에 대한 수요가 증가하고 있다. 이와 같은 모바일 통신 시스템에는 70dB이상의 SFDR(Spurious Free Dynamic Range)을 가진 ADC(Analog-to-Digital Converter)가 사용된다. 본 논문에서는 모바일 통신 시스템을 위한 SFDR 70dBc의 성능을 제공하는 10비트, 100Msps 파이프라인 ADC를 제안한다. 제안한 ADC는 요구되는 해상도 및 속도 사양을 만족시키기 위해 3단 파이프라인 구조를 채택하였으며, 입력단 SHA(Sample and Hold)회로에는 Nyquist 입력에서도 10비트 이상의 정확도로 신호를 샘플링하기 위해 부트스트래핑 기법 기반의 샘플링 스위치를 적용하였다. residue amplifier 회로에는 전력을 줄이기 위해 8배 residue amplifier 대신 3개의 2배 ressidue amplifier를 사용하였다. ADC의 높은 사양을 만족시키기 위해서는 높은 이득을 가지는 op-amp가 필수적이다. 제안한 ADC 는 0.18um CMOS 공정으로 설계되었으며, 100Msps의 동작 속도에서 70dBc 수준의 SFDR과 60dB 수준의 SNDR(Signal to Noise and Distortion Ratio)을 보여준다.

  • PDF

Development of Nondestructive Grouping System for Soil Organic Matter Using VIS and NIR Spectral Reflectance

  • Sung J.H.
    • Agricultural and Biosystems Engineering
    • /
    • v.6 no.1
    • /
    • pp.15-21
    • /
    • 2005
  • This study was conducted to develop a nondestructive grouping system for soil organic matter using visible (VIS) and near infrared (NIR) spectroscopic method. The artificial light was irradiated on the cut soil surface at 15 to 20 cm depths to reduce the errors of light at open field. The reflectance energy from the cut soil surface was measured to group the soil organic matter using VIS/NIR light sensor with narrow band pass filter. From reflectance spectra of soil samples, the sensitive wavelengths for measuring the soil organic matter were selected and compared to previous research results. The grouping system for soil organic matter consisted of light sensor with band pass filter measuring the reflectance energy of the cut soil surface, global positing system (GPS), analog-to-digital (AD) converter, computer and operating software. The regression models to predict the soil organic matter were developed and evaluated. From field test, the accuracies of the developed light sensor system were 81.3% for five-stage grouping of the soil organic matters and 91.0% for three-stages grouping of the soil organic matters, respectively. It could be possible to support the decision making for variable rate applications with the developed grouping system for soil organic matter in precision agriculture.

  • PDF

Horary System of the Early Chosen and the King Sejong′s Striking Clepsydra : (1) Water-Clocks (조선초기의 시제와 세종의 자격루:(1) 물시계)

  • 남문현;한득영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.697-701
    • /
    • 1996
  • King Sejong's Striking water-clock which brought in use on the first of July in 1434 was mainly composed of timekeeping and time announcing parts signalling twelve double-hours, and five night-watches and night-watch-divisions automatically by means of ball-operating jackworks. The clock was arranged with dual timekeeping system, the one for a full day(twelve double-hours) and the other for five night-watches achieving twelve double-hours and one-hundred interval horary systems. The vessels were arrayed in inflow-type water-clock, a large reservoir on the highest story, a constant-level tank for supplying water to the measuring vessel evenly in the middle, and the lowest tank to receive water from the above constant-level tank. An indicator-rod on the float was raised upwards depending on the water-level increase to show timing scales and also to release small bronze balls from the ball-rack mechanisms implanted on the measuring vessel to signal timing intervals.

  • PDF

An Ultra-precision Electronic Clinometer for Measurement of Small Inclination Angles

  • Tan, Siew-Leng;Kataoka, Satoshi;Ishikawa, Tatsuya;Ito, So;Shimizu, Yuuki;Chen, Yuanliu;Gao, Wei;Nakagawa, Satoshi
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.539-546
    • /
    • 2014
  • This paper describes an ultra-precision electronic clinometer, which is based on the capacitive-based fluid type, for detection of small inclination angles. The main parts of the clinometer low-noise electronics are two capacitance measurement circuits for converting the capacitances of the capacitors of the clinometer into voltages, and a differential amplifier for obtaining the difference of the capacitances, which is proportional to the input inclination angle. A 16 bit analog to digital (AD) converter is also embedded into the same circuit board, whose output is sent to a PC via RS-232C, for achieving a small noise level down to tens of ${\mu}v$. A compensation method, which is referred to as the delay time method for shortening the stabilization time of the sensor was also discussed. Experimental results have shown the possibility of achieving a measurement resolution of $0.0001^{\circ}$ as well as the quick measurement with the delay time method.

Detection of Blood Agent Gas Using $SnO_2$ Thin Film Gas Sensor

  • Choi, Nak-Jin;Kwak, Jun-Hyuk;Lim, Yeon-Tae;Joo, Byung-Su;Lee, Duk-Dong;Bahn, Tae-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.E2
    • /
    • pp.69-75
    • /
    • 2004
  • In this study, thin film gas sensor based on tin oxide was fabricated to examine its characteristics. Target gas is acetonitrile ($CH_3$CN) which is a blood simulant for the chemical warfare agent. Sensing materials are SnO$_2$ SnO$_2$/Pt, and Sn/Pt with thickness from 1000 to 3000 $\AA$. The sensor consists of a sensing electrode with inter-digit (IDT) type in front side and a heater in rear side. Resistance changes of sensing materials are monitored on real time basis using a data acquisition board with a 12-bit analog to digital converter. Sensitivities are measured at different operating temperatures also with different gas concentrations and film thickness. The high sensitivity is obtained for Sn (3000 $\AA$)/Pt (30 $\AA$) at 30$0^{\circ}C$ for 3 ppm. Response and recovery times were about 40 and 160 s, respectively. Repetition measurements showed very good results with $\pm$3% in full scale range.

A Fast RSSI using Novel Logarithmic Gain Amplifiers for Wireless Communication

  • Lee, Sung-Ho;Song, Yong-Hoon;Nam, Sang-Wook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.9 no.1
    • /
    • pp.22-28
    • /
    • 2009
  • This paper presents a fast received signal strength indicator (RSSI) circuit for wireless communication application. The proposed circuit is developed using power detectors and an analog-to-digital converter to achieve a fast settling time. The power detector is consisted of a novel logarithmic variable gain amplifier (VGA), a peak detector, and a comparator in a closed loop. The VGA achieved a wide logarithmic gain range in a closed loop form for stable operation. For the peak detector, a fast settling time and small ripple are obtained using the orthogonal characteristics of quadrature signals. In $0.18-{\mu}m$ CMOS process, the RSSI value settles down in $20{\mu}s$ with power consumption of 20 mW, and the maximum ripple of the RSSI is 30 mV. The proposed RSSI circuit is fabricated with a personal handy-phone system transceiver. The active area is $0.8{\times}0.2\;mm^2$.

Posture for Distortion Measurement and Analysis Through the Pressure Distribution During a Person Walking (인체보행 시 양발에 가해지는 압력분포를 통한 자세 뒤틀림 측정 및 분석)

  • Hong, Ju-Hee;Kim, Kyung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.487-492
    • /
    • 2016
  • In this paper, a device for analyzing the pressure distribution during walking was produced by using the pressure sensor on the heel. This device was limited to a frequency band by using the 1st low-pass filter. And an algorithm to analyze the value of the quantity to pressure using a analog to digital converter. It is used by using the threshold voltage of pressure sensor, it is suggested the algorithm. The algorithm is detected the peak which is exceeded the threshold voltage. and thus in accordance, it is detected the number of steps. And the calorie consumption were detected by using it. Also it used an MCU and Bluetooth. And by confirming the data at the LCD of the other MCU, it was to reduce the size of the device. According to this algorithm, it has the advantage that there is no restriction on the activity than when using an imaging device and it is inexpensive than other sensors such as an acceleration sensor or a gyro and it is easy to handle.

A Hybrid Audio ${\Delta}{\Sigma}$ Modulator with dB-Linear Gain Control Function

  • Kim, Yi-Gyeong;Cho, Min-Hyung;Kim, Bong-Chan;Kwon, Jong-Kee
    • ETRI Journal
    • /
    • v.33 no.6
    • /
    • pp.897-903
    • /
    • 2011
  • A hybrid ${\Delta}{\Sigma}$ modulator for audio applications is presented in this paper. The pulse generator for digital-to-analog converter alleviates the requirement of the external clock jitter and calibrates the coefficient variation due to a process shift and temperature changes. The input resistor network in the first integrator offers a gain control function in a dB-linear fashion. Also, careful chopper stabilization implementation using return-to-zero scheme in the first continuous-time integrator minimizes both the influence of flicker noise and inflow noise due to chopping. The chip is implemented in a 0.13 ${\mu}m$ CMOS technology (I/O devices) and occupies an active area of 0.37 $mm^2$. The ${\Delta}{\Sigma}$ modulator achieves a dynamic range (A-weighted) of 97.8 dB and a peak signal-to-noise-plus-distortion ratio of 90.0 dB over an audio bandwidth of 20 kHz with a 4.4 mW power consumption from 3.3 V. Also, the gain of the modulator is controlled from -9.5 dB to 8.5 dB, and the performance of the modulator is maintained up to 5 nsRMS external clock jitter.