• Title/Summary/Keyword: An apartment house

Search Result 392, Processing Time 0.024 seconds

Evaluation of Influence Factors in order to introduce Share-styled Apartment House Successfully (지분형 주택분양제도의 성공적인 도입을 위한 영향요인 분석)

  • Lee, Hyun-Chul;Lim, So-Yean;Go, Seong-Seok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.1
    • /
    • pp.79-87
    • /
    • 2010
  • The purpose of this study is to find decisive factors affecting Share-styled Apartment house Lee Myung-bak announced for the homeless masses in February 2008. This policy tried to add up defects from Half-priced Apartment house enforced in 2007. Seoul is ranked as the highest PIR(Price Income Rate) city in the world, as far as the difficulties in getting own house is concerned. Korean government has announced a lot of policies to control the price of real-estate, especially housing bubble phenomenon, since the convalescence from IMF financial crisis. By making questionnaires to get an important factor and taking counsel with related specialists, this thesis found what kind of roles the objects including government, institutions and people should play or focus on.

An Experimental Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses (천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 실험적 연구)

  • Baek, Eun-Sun
    • KIEAE Journal
    • /
    • v.7 no.1
    • /
    • pp.95-100
    • /
    • 2007
  • In apartment houses, said to be similar to a typical housing form, every household share the walls and floors. Many problems inevitably accompany such as an arrangement, as noise and vibration are shared among households. When investigating the percentage of apartment resident's dissatisfaction with housing environments, discontent due to noise ranks the highest. Among many different kinds of noises, noise such as floor crashing sounds show the highest indication rate in the residents' comparison of discontent. Therefore, it is the practice of insulating against noises such as floor crashing sounds that improves the apartment house environments. The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames +Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

A Study on the Air Flow Characteristics in an Apartment Complex and Ventilation Performance of an Individual Unit for Improving IAQ (주동형태 변화에 따른 아파트 단지내 기류분석 및 단위주호의 환기성능에 관한 연구)

  • Lee, Jung-Hyun;Lee, Seung-Hee;Kim, Taeyeon
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.11-16
    • /
    • 2005
  • The recent trends of high-density and high-rise in apartment housing have caused the problems of decrease in ventilation rates and increase of indoor pollutant contaminants. SHS(Sick House Syndrome) has now become a major issue and threats the health of residents. To solve these indoor air problems, increase in ventilation rate is considered as one of the most efficient approach. Thus, the recent housing development is pursuing improvement in the site design and the layout of apartment building blocks to promote natural ventilation is now investigated as one of the fundamental solutions. This study was focused on the air flow characteristics of outdoor environment in an apartment complex to keep the pollutants out of the site. Age of air and pressure difference have been used as indices of the outdoor air quality. Four different types of apartment building layouts have been analyzed by CFD simulation. This study again selected a real apartment housing complex as a case study model. By analyzing the pressure differences between the front and rear of an apartment building block, the ventilation performance in each individual unit was evaluated, and its impact on ventilation performance is investigated by analyzing the stagnant air around the apartment building blocks. During this process, existing patterns of apartment housing layout have been evaluated, and the most appropriate site layout has been chosen to analyze the outdoor airflow patterns. Based on the analysis of airflow patterns of site layout, the possibilities of improving ventilation performance of an individual apartment housing is proposed.

A study on the Estimation of Standard Heating City Gas Consumption of Apartment Housing (공동주택의 난방용 도시가스 표준사용량 산정에 관한 연구)

  • Shim, Yun-Hee;Choi, Chang-Ho;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.3
    • /
    • pp.89-97
    • /
    • 2006
  • Our Housing culture continuously changes for the correspondence to social development and changes of economy, and be developing. A massive apartment complex continuously increased, and According to this in our country heating energy consumption of a residential building is continuously increasing at country me whom was limited in order to raise efficient residential land use and diffusion ratio of house. If confirm an element to be able to reduce use of a heating energy, and there is saving possibility to parts of energy saving, this study will present the standard amount used with bases to the gas amount used for heating and Field Test data about room temperature. Execute simulation with building balance (public area, a plain), the gas amount useds such as incense of a building, indoor setting temperature ($^{\circ}C$), a position of an apartment house etc. to affect the energy amount used of a valuation object building of a variable through Field Test and research on the actual condition. Calculate the standard amount used of city gas for winter season heating of a comparative analysis apartment house to data value getting the above results through Field Test and simulations with bases.

Energy Consumption on Balcony Remodeling Type in an Apartment House (공동주택에서 발코니 확장형이 에너지소비에 미치는 영향)

  • Hyun, Jong-Hun;Choi, Moo-Hyuck;Kim, Ji-Yeon;Park, Hyo-Soon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1406-1411
    • /
    • 2008
  • The percentage of apartment houses in residential buildings has increased every year, and it result in higher energy consumption of residential buildings. After the house law could be amended to legalize the remodeling of the balcony, buyers and contractors prefer to choose the balcony remodeling type when they choose a house for installment sale. Many construction companies design an apartment house considering balcony remodeling. So, this paper compares the balcony remodeling type with the basic type(prior to remodeling balcony) by using the building energy rating system tool. The balcony remodeling type consumes heating energies more than the basic type, and is unable to receive high rating. If the balcony is remodeled, it is required to improve the performance of wall and window and reduce the area of remodeling balcony.

  • PDF

Study on the efficient noise prediction for an apartment house (공동주택 소음예측 방법에 관한 연구)

  • Ko, J.H.;Kim, D.J.;Park, S.J.;Chang, S.I.;Cho, M.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.505-509
    • /
    • 2008
  • This paper studied the efficient noise prediction method for new apartment house near the road traffic noise. Three noise prediction software were compared by each prediction noise level using the simple model which is included the road, soundproofing wall and building. Two foreign national calculation models(RLS-90 and NMPB) were verified by comparison of measured sound level. Frequency of sound level was predicted by NMPB and compared by measured data. The sphere of noise source and facade reflection were proposed to accurate predict the road traffic noise in new apartment house.

  • PDF

A Study on Functionality Evaluation of Profit Model for Remodeling of Apartment House (공동주택 리모델링을 위한 수익모델의 기능성 평가 연구)

  • An, Min-Jae;Pyo, Jin-Myung;Kim, Eui-Sik
    • Journal of the Korea Institute of Building Construction
    • /
    • v.5 no.2 s.16
    • /
    • pp.107-113
    • /
    • 2005
  • This study analyzes remaining repair rate and applied repair rate with the presentation of profit model for the purpose of pursuing maximization of added value through remodeling of apartment house. Objects of remodeling and item applying the whole replacement of functionality evaluation items include exterior of building (3 items maintaining the current conditions, 8 items requiring the whole replacement), water supply/sanitary/gas/ventilation facilities (6 items maintaining the current conditions, 6 items requiring the whole replacement, electric/fire fighting/elevator facilities (8 items maintaining the current conditions, 20 items requiring the whole replacement) and heating/water heater facilities (2 items requiring the whole replacement).

The Study on Case Analysis of an Apartment House Defects (공동주택 하자사례 분석에 관한 연구)

  • 이희두;이해진;김진호;임남기
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.130-135
    • /
    • 2001
  • In this study, I have researched into the causes of defects in apartment house, The results of this study are listed below. (1) Water leakages which result from land sinking and cracks, results of misuse of back filling method, are the main reason of defects in civil engineering work and architectural work. (2) Inexperience and unwillingness are the main reason of defects in plaster work. (3) In windows work and painting work, the main reasons are lacks of precision construction and efflorescence resulting from outdoor air, respectively. (4) Defects in waterproofing work and electric work result from fault construction by low unit Costs. (5) Equipment work requires uses of standardized construction materials and management, and landscape architecture work requires minimizing human mistakes, for instance, degin carelessness. For the reasons stated above, the causes of defects in apartment house are insufficient construction labors, inferior construction materials, urgent construction process time, and conscientiousless industrialists who only seek after a profit margin.

  • PDF

Field Measurement of the Reverberation Time in Occupied and Unoccupied Apartment Houses (공동주택 입주 전.후 세대에서의 잔향시간 측정 및 비교)

  • Lee, Byoung-Ki;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.654-657
    • /
    • 2005
  • The aim of this study is to investigate and to analyze the reverberation times of apartment houses Measurements were conducted in a total of 44 rooms(36 rooms were in occupied houses and 8 rooms were in unoccupied houses) according to KS F 2864. The results showed that the averaged reverberation time of the occupied and the unoccupied houses were about 0.3$\sim$0.5sec and 1.2$\sim$l.5 sec, respectively, at 500Hz octave band frequency. And the averaged absorbtion coefficient of the occupied and the unoccupied houses were about 0.13$\sim$0.35 and 0.11$\sim$0.20, respectively. In addition, We verified that the reverberation time generally depended on the frequency; the lower the frequency, the higher the reverberation time.

  • PDF

A Study on the City Wind Trail in Daegu (대구시 도시풍도에 대한 연구)

  • Choi, Young-Sik
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.1
    • /
    • pp.29-35
    • /
    • 2006
  • The population of Daegu, the third biggest city in Korea, is two point six million. Daegu is known as a basin or a city where it is not only too hot in summer but also too cold in winter. Recently with redevelopment apartment house boom, a 40-story or more apartment complexes are under construction near Shin-cheon and Dondaegu-ro, the south-north axis of Daegu. It is necessary to raise several points about blocking a road of the wind by high-rise apartment buildings and apartment complexes. As a kind of the green policy, Daegu enlarge the distance between apartment building by reconstructing low-rise apartment into high-rise and impose a duty of a green space on the ground by making a parking zone into an underground. Through this process, apartment complexes changed from a '一'shape to a '口'shape. It increases heat island phenomenon of a city by blocking a road of the wind that comes from Shin-cheon and Dondaegu-ro. To circulate the polluted air of Daegu basin, we need local wind. There are four effective measures. 1) Throw three greens into one in the center of the road at the north side in the same way of the south side of Dongdaegu-ro, 2) reflect the information of roads of the wind including heights, spaces and directions of buildings, 3) steer clear of a high-rise buildings and development apartment house constructions, and 4)select a city for benchmarking to be the environmental capital.

  • PDF