• Title/Summary/Keyword: Amplitude estimate

Search Result 243, Processing Time 0.03 seconds

Excitatory Influences of Noradrenaline on the Spontaneous Contractions and Electrical Activity of Antral Circular Muscle of the Guinea-pig Stomach

  • Lee, Taik-Jong;Kim, Jin-Hwan;Kim, Ki-Whan
    • The Korean Journal of Physiology
    • /
    • v.25 no.2
    • /
    • pp.147-158
    • /
    • 1991
  • The effects of noradrenaline on the spontaneous contraction recorded from a strip of mucosa-free antral circular muscle were studied in the guinea-pig stomach, and the changes in slow waves and membrane resistance were analyzed in order to elucidate the mechanism for the excitatory response to noradrenaline. Electrical responses of circular muscle cells were recorded using glass microelectrodes filled with 3 M KCI. Electrotonic potentials were produced to estimate membrane resistance by the partition stimulating method. All experiments were performed in tris-buffered Tyrode solution which was aerated with 100% $O_2$ and kept at $35^{\circ}C$. The results obtained were as follows: 1) The spontaneous contractions were potentiated dose-dependently by the application of noradrenaline. 2) Through the experiments using adrenoceptor-blockers, the strong excitatory effect via $[\alpha}-adrenoceptors$ and the weak inhibitory efffect via ${\beta}-adrenoceptors$ were noted. 3) Noradrenaline produced hyperpolarization of membrane potential, and increases in the amplitude and the maximum rate of rise of slow waves. 4) In the presence of apamin, Ca-dependent K channel blocker, the characteristic hyperpolarization was not developed. However, the excitatory effect of noradrenaline on spontaneous contraction remained. 5) Membrane resistance was reduced during the hyperpolarized state by the application of noradrenaline, and the change of membrane resistance and the hyperpolarized state were completely abolished by apamin. From the above results, following conclusions could be made: Excitatory responses to noradrenaline result from the dominant ${\alpha}-excitatory$, and the weak ${\beta}-inhibitory$ action of noradrenaline. Hyperpolarization of membrane potential by noradrenaline is due to the activation of Ca-dependent K channel.

  • PDF

Colonial Cyanobacteria, Microcystis Cell Density Variations using Ultrasonic Treatment (초음파 처리 조건에 따른 집락형 유해남조류 Microcystis 세포수 변화 연구)

  • Lee, Hae-Jin;Park, Hae-Kyung;Heo, Jun;Lee, Hyeon-Je;Hong, Dong-Gyun
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.2
    • /
    • pp.210-215
    • /
    • 2018
  • It is difficult to count colonial cyanobacteria Microcystis cells since the thickness of colonies is constrained by amorphous mucilage, making it impossible to estimate the number of cells. Disaggregation of Microcystis colonies into single cell is needed to improve the accuracy and precision of cell density estimation of naturally collected samples. Uultrasonic treatment method is commonly used owing to the simplicity and immediacy of the procedure. However, amplitude, frequency, and duration of ultrasonic treatment also cause cell loss during the experiment. Optimal ultrasonic treatment has not been standardized yet. Therefore, the objective of this study was to investigate optimal ultrasonic treatment by analyzing cell density and colony numbers. We collected colonial Microcystis from Changnyeong-Haman weir area in Nakdong River during harmful algal boom period from September to October in 2017. Ultrasonic treatment method was applied to disrupt colonies into single cells to enumerate cell density. Among treatment conditions, results from continuously treated for 100 seconds were found to be the optimum to reduce colonies to a suspension of single cell without cell losses under high and low density of Microcystis cells. Lugol iodine fixed cells followed by sonication showed less negative impact of cell damage within the optimal treatment time (100 seconds). Furthermore, disaggregated cells treated by sonication enables microscopic observation more easily since gas vacuoles were collapsed to facilitate sedimentation of cells under the counting chamber for quantitative enumeration of buoyant Microcystis cells.

Estimation of Pump Induced Vibration Force by Frequency Response Function (진동수응답함수 측정에 따른 펌프 가진력 산정)

    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.3 no.1
    • /
    • pp.103-112
    • /
    • 1999
  • This is study to estimate the pump induced vibration in time and frequency domain by frequency response function between two points in case of 20Hp and 50Hp centrifugal pumps. The frequency response function has real and imaginary information of signals, and response function has also real and imaginary information. So the vibration force can be obtained from the response function and frequency response function by complex calculation. And it is compared with the theoretically estimated values and it is suggested that the amplitude of vibration with main frequency is about 10~25% of pump and motor weight, and the magnitude of unbalanced mass is about 30~60% of pump and motor weight to estimated vibration force in time domain. There are the other kinds of vibration components with different frequency values of 2~3 times of its main frequency, and these kinds of information are used to control the tuning ratio between operating frequency of pump and structural frequency of concrete slab.

  • PDF

Finite Element Modelling of Axially Compressed GFRP Cylindrical Panels (축방향으로 압축을 받는 GFRP 원통형 판넬의 유한요소 모델링)

  • Kim, Ki Du
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.15-25
    • /
    • 1993
  • In order to promote the efficient use of composite materials, effort is currently being directed at the development of design criteria for composite structures. Insofar as design against buckling is concerned, it is well known that, for metal shells, a key step is the definition of 'knockdown' factors on the elastic critical buckling stress accounting mainly for the influence of initial geometric imperfections. At present, the imperfection sensitivity of composite shells has not been explored in detail. Due to the large number of parameters influencing buckling response (considerably larger than for isotropic shells), a very large number of tests would be needed to quantify imperfection sensitivity experimentally. An alternative approach is to use validated numerical models for this task. Thus, the objective of this paper is to outline the underlying theory used in developing a composite shell element and to present results from a validation exercise and subsequently from a parametric study on axially loaded glass fibre-reinforced plastic (GFRP) curved panels using finite element modelling. Both eigenvalue and incremental analyses are performed, the latter including the effect of initial geometric imperfection shape and amplitude, and the results are used to estimate 'knockdown' factors for such panels.

  • PDF

A Study on Multi Beam Steering using Weight Error Compensation Algorithm and SVD in Wireless System (무선 시스템에서 가중치 오차 보정 알고리즘과 SVD를 이용한 다중 빔 조향에 대한 연구)

  • Lee, Kwan-Hyeong;Song, Woo-Young;Lee, Myeong-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.2
    • /
    • pp.143-148
    • /
    • 2013
  • This paper study about multi-beam for ditection of arrival estimation in wireless system. estimate a direction of arrival of target in multi input-output array antennas system. Beam steering method are divided by beam steering method of elevation angle or beam forming method, stack beam steering, frequency steering, phase steering radar and digital beam forming radar. Proposed algorithm is combined SVD method and antenna weight error compensation method with phase and amplitude compensation to effectivity beam steering. Through simulation, we were analysis of performance that general algorithm and proposed target estimation algorithm in this paper. It was proved to improved proposal algorithm than general algorithm in target direction of arrival estimation.

A Study of the Guided Wave Propagation in the Water Supplying Pipes with Scale (스케일이 있는 급수관내의 유도초음파의 전파 특성에 관한 연구)

  • Song, Sung-Jin;Lee, Dong-Hoon;Lee, Hyun-Dong;Bae, Cheol-Ho;Park, Jung-Hoon;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2003
  • Since the scale in pipes reduces the flow rate, a quantitative evaluation of the scale is essential for the proper maintenance of pipes. Guided waves were employed to estimate the amount of scale in water supplying pipes. Using variable angle wedge, several modes of guided waves wire generated and their propagation charcteristics along the pipes with stale were analyzed. It was experimentally observed that the amplitude of F(M,2) modes at $f{\times}d=1.5MHz\;mm$ decreased significantly with increasing amount of scale. The present study showed that F(M,2) modes were optima) to evaluate the scale in water supplying pipes.

Analysis of Harmonic Wave Generation in Nonlinear Oblique Crack Surface (비선형 경사 균열면에서의 고조파 발생 특성 해석)

  • Kim, Noh-Yu;Yang, Seung-Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.4
    • /
    • pp.376-387
    • /
    • 2012
  • Based on the nonlinear spring model coupled with perturbation method, 2nd harmonic waves generated by oblique incident ultrasound on nonlinear crack interface were calculated and investigated. Reflected and transmitted waves from the interface were determined and analyzed at various angle of incidence for the cracks with different interfacial stiffness in order to estimate the 2nd harmonic generation of incident ultrasound. It was shown in computer simulation that the 2nd harmonic components changed much with the increase of incidence angle in both reflected and transmitted wave, but became very small when the incident angle approached toward 90 degree. It can be concluded that the 2nd harmonic component of reflected wave has a meaningful amplitude as much as the transmitted 2nd harmonic wave from partly closed crack.

LOCAL ANOMALIES AROUND THE THIRD PEAK IN THE CMB ANGULAR POWER SPECTRUM OF WMAP 7-YEAR DATA

  • Ko, Kyeong Yeon;Park, Chan-Gyung;Hwang, Jai-Chan
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.2
    • /
    • pp.75-91
    • /
    • 2013
  • We estimate the power spectra of the cosmic microwave background radiation (CMB) temperature anisotropy in localized regions of the sky using the Wilkinson Microwave Anisotropy Probe (WMAP) 7-year data. We find that the north and south hat regions at high Galactic latitude ($|b|{\geq}30^{\circ}C$) show an anomaly in the power spectrum amplitude around the third peak, which is statistically significant up to 3. We try to explain the cause of the observed anomaly by analyzing the low Galactic latitude ($|b|$ < $30^{\circ}C$) regions where the galaxy contamination is expected to be stronger, and the regions weakly or strongly dominated byWMAP instrument noise. We also consider the possible effect of unresolved radio point sources. We find another but less statistically significant anomaly in the low Galactic latitude north and south regions whose behavior is opposite to the one at high latitude. Our analysis shows that the observed north-south anomaly at high latitude becomes weaker on regions with high number of observations (weak instrument noise), suggesting that the anomaly is significant at sky regions that are dominated by the WMAP instrument noise. We have checked that the observed north-south anomaly has weak dependences on the bin-width used in the power spectrum estimation, and on the Galactic latitude cut. We also discuss the possibility that the detected anomaly may hinge on the particular choice of the multipole bin around the third peak. We anticipate that the issue of whether or not the anomaly is intrinsic one or due to WMAP instrument noise will be resolved by the forthcoming Planck data.

A New Fading Estimation Method for PSAM in Digital Land Mobile Radio Channels (PSAM방식에 적용할 수 있는 새로운 페이딩 추정방식)

  • 김영수;김창주;정구영;문재경;박한규;최상삼
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.2
    • /
    • pp.126-136
    • /
    • 1997
  • When we apply the spectrally efficient quadrature amplitude modulation(QAM) to mobile communications, it is necessary to estimate and compensate the channel charac- teristics. In this paper, a new type fading estimation method for PSAM using sinc function is presented. Gaussian interpolation method has a drawback that the performance degrades rapidly if pilot symbol period increases even though pilot sysbol period is less than Nyquist sampling rate. The Wiener filter method does not degrade until pilot symbol period is equal to the Nyquist sampling rate. It is difficult for Wiener filter method to be applied to real system because autocorrelation function of channel gain, Doppler frequency and SNR(signal to noise ratio) must be known to optimize the filter coefficients. But proposed method has a similar performance to the Wiener filter method, and does not need to know the autocorrelation function of channel gain, the doppler frequency and SNR. Therefore the proposed method cna be applied to real system easily.

  • PDF

Prediction of Reliability of Fatigue Limit of S34MnV Steel for Marine Diesel Engine Crank Throw Components (선박용 디젤 엔진 크랭크 스로 부품용 S34MnV강의 피로한도에 대한 신뢰도 예측)

  • Kim, Seon Jin;Kong, Yu Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.8
    • /
    • pp.751-757
    • /
    • 2016
  • The aim of this study is to estimate the reliability of fatigue limit of the material used for crank throw components according to the staircase method. The material used for crank throw components is forged S34MnV grade steel, which is heat treated by normalizing and tempering. In this work, to predict the reliability of the design fatigue strength, axially loaded constant amplitude fatigue testing was conducted. The test specimens were loaded with an axial push/pull load with a mean stress of 0 MPa, which corresponds to a stress ratio of R=-1. The fatigue test results were evaluated by Dixon-Mood formulas. The values of mean fatigue strength and standard deviation predicted by the staircase method were 296.3 MPa and 10.6 MPa, respectively. Finally, the reliability of the fatigue limit in some selected probability of failure is predicted. The proposed method can be applied for the determination of fatigue strength for design optimization of the forged steel.