• Title/Summary/Keyword: Amperometric Biosensor

Search Result 47, Processing Time 0.02 seconds

Electrochemical properties of the mugwort-embedded biosensor for the determination of hydrogen peroxide (쑥을 이용한 과산화수소 정량 바이오센서의 전기화학적 성질)

  • Lee, Beom-Gyu;Park, Sung-Woo;Yoon, Kil-Joong
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.58-64
    • /
    • 2006
  • A mugwort-tissue-based modified carbon paste electrode was constructed for the amperometric detection of hydrogen peroxide and its electrochemical properties are described. Especially the amperometric signal was very stable and bigger than any other enzyme electrode studied in this lab. The effect of tissue composition on the response was linear within the wide range of experiment and the linearity of Lineweaver-Burk plot showed that the sensing process of the biosensor is by enzymatic catalysis. And pH dependent current profile connoted that two isozymes are active in this system.

Development of Glucose Biosensor Using Sol-Gel Reaction of Tetraethoxysilane (Tetraethoxysilane의 졸-겔 반응을 이용한 전기화학적 glucose biosenor 개발)

  • Chang, Seong-Cheol;Park, Deog-Su
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.311-317
    • /
    • 2012
  • Disposable amperometric screen-printed biosensor strips have been fabricated by a sol-gel encapsulation for the analysis of glucose. The glucose oxidase(GOx) is entrapped in the gel matrix through sol-gel transition of tetraethoxysliane(TEOS). The biosensor is fabricated by GOx containing thin film of TEOS gel on the surface of screen-printed carbon electrode(SPCE). The GOx-containing thin film of TEOS gel offers a one-step modification process on the surface of SPCE. The optimum conditions for glucose determination have been characterized with respect to the applied potential, enzyme loading ratio, and pH. The linear range and detection limit of glucose detection were from 2.0 mM to 16.0 mM and 0.25 mM, respectively.

Electrochemical Detection of Self-Assembled Viologen Modified Electrode as Mediator of Glucose Sensor

  • Lee, Dong-Yun;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.106-110
    • /
    • 2009
  • An amperometric glucose biosensor has been developed using viologen derivatives as a charge transfer mediator between a glucose oxidase (GOD) and a gold electrode. A highly stable self-assembled monolayer (SAM) of thiol-based viologen was immobilized onto the gold electrode of a quartz crystal microbalance (QCM) and GOD was immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of -300mV. Upon immobilization of the glucose oxidase onto the viologen modified electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance, such as pH potential, were optimized and assessed. This biosensor offered excellent electrochemical responses for glucose concentration below ${\mu}$ mol level with high sensitivity and selectivity and short response time. The levels of the RSDs (<5%) for the entire analyses reflected the highly reproducible sensor performance. A linear calibration range between the current and the glucose concentration was obtained up to $4.5{\times}10^{-4}M$. The detection limit was determined to be $3.0{\times}10^{-6}M$.

$H_2O_2$ Detection Property of Glucose Sensor using Self Assembled Viologen Modified Electrode as Mediator (Viologen 유도체를 전하전달체로 이용한 Glucose 센서의 $H_2O_2$ 검출 특성)

  • Lee, Dong-Yun;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.86-87
    • /
    • 2007
  • An amperometric glucose biosensor has been developed using viologen derivatives as electron mediator of glucose oxidase (GOD) at Au electrode. Highly stable self assembled monolayer (SAM) of thiol-based viologen is immobilized onto the Au electrode followed byGOD is immobilized onto the viologen modified electrode. This biosensor response to glucose was evaluated amperometrically in the potential of -300 mV. Upon immobilization of glucose oxidase onto the viologen modified-electrode, the biosensor showed rapid response towards glucose. Experimental conditions influencing the biosensor performance such as, pH, potential were optimized and assessed. This biosensor offered an excellent electrochemical response for glucose concentration below ${\mu}mol$ level with high sensitivity and selectivity and short response time. The levels of the RSD's (< 5 %) for the entire analyses reflected the highly reproducible sensor performance. Using the optimized a linear relationship between current and glucose concentration was obtained up to $4.5{\times}10^{-4}$ M. In addition, this biosensor showed well reproducibility and stability.

  • PDF

Amperometric Determination of Urea Using Enzyme-Modified Carbon Paste Electrode

  • Yang, Jae-Kyeong;Ha, Kwang-Soo;Baek, Hyun-Sook;Lee, Shim-Sung;Seo, Moo-Lyong
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.10
    • /
    • pp.1499-1502
    • /
    • 2004
  • An amperometric biosensor based on carbon paste electrodes (CPEs) for the determination of urea was constructed by enzyme (urease/GL-DH)-modified method. Urea was hydrolyzed to ${NH_4}^+$ by catalyzing urease onto the enzyme-modified electrode surface in sample solution. In the presence of ${\alpha}$-ketoglutarate and reduced nicotinamide adenine dinucleotide(NADH), a liberated ${NH_4}^+$ produce to L-glutamate and $NAD^+$ by Lglutamate dehydrogenase (GL-DH). After the chemical reaction was proceeded, the electrochemical reaction was occurred that an excess of the NADH was oxidized to $NAD^+$. The oxidation current of NADH was monitored at +1.10 volt vs. Ag/AgCl. An optimum conditions of biosensor were investigated: The optimum pH range for catalyzed hydrolysis reaction of urea was pH 7.0-7.4. The linear response range and detection limit were $2.0\;{\times}\;10^{-5}{\sim}2.0\;{\times}\;10^{-4}M\;and\;5.0\;{\times}\;10^{-6}M$, respectively. Another physiological species did not interfere, except L-ascorbic acid.

Enhanced Sensitivity of PEDOT Microtubule Electrode to Hydrogen Peroxide by Treatment with Gold (금 처리를 통한 PEDOT 마이크로튜브 전극의 과산화수소 검출 특성 향상)

  • Park, Jongseo;Son, Yongkeun
    • Polymer(Korea)
    • /
    • v.38 no.6
    • /
    • pp.809-814
    • /
    • 2014
  • An array structure of conducting polymer microtubule was fabricated for an amperometric biosensor. 3,4-Ethylenedioxythiophene (EDOT) was electropolymerized in the microporous template membrane with poly(3,4-ethylenedioxythiophene)/poly(4-styrenesulfonic acid) (PEDOT/PSS) composite as a binder. The array structure can provide enhanced current collecting capability due to large active surface area compared to the macroscopic area of the electrode itself. For a biosensor application, the array electrode was tested for $H_2O_2$ detection and showed very sluggish electrochemical response to $H_2O_2$. To enhance the detection efficiency to the oxidation of $H_2O_2$, gold was treated on the electrode by two different approaches: sputtering and electrochemical deposition. Gold treatment with either method greatly enhanced the sensitivity of the electrode to $H_2O_2$. So, conducting polymer microtubule array with gold treatment was expected to be a sensitive amperometric biosensor system based on the detection of $H_2O_2$.

Quantitative Analysis of Ergosterol as a Biomarker of Mold-contaminated Foods Using the Enzyme Biosensor (효소 바이오센서를 이용한 식품의 곰팡이 오염 지표물질인 Ergosterol 정량분석)

  • Kim, Mi-Kyeong;Kim, Jong-Won;Kim, Mee-Ra
    • Korean journal of food and cookery science
    • /
    • v.25 no.2
    • /
    • pp.252-259
    • /
    • 2009
  • Ergosterol is the significant component of the cell wall of fungi. Its presence is regarded as evidence of fungi contamination in grain and other foods. Many studies on ergosterol detection have been carried out using chemical methods, but those methods required complicated pre-treatments and long analysis times. In this study, an amperometric biosensor was developed for fast and precise ergosterol detection. The biosensor system used the electron transfer of hydrogen peroxide produced from the reaction of ergosterol with cholesterol oxidase. The biosensor system consisted of a peristaltic pump, a syringe loading sample injector, an enzyme reactor, a fabricated flow-through cell containing a working electrode, a reference electrode and a counter electrode, and a potentiostat/recorder. The working electrode was prepared by coating modified multi-wall carbon nanotube (MWNT) on glassy carbon electrode. The $MWNT-NH_2$ coated glassy carbon electrode linearly responded to hydrogen peroxide in the range of $1{\times}10^{-5}{\sim}8{\times}10^{-5}$ M with a detection limit of $10^{-7}$ M in the basic performance test. The currents produced from the ergosterol biosensor showed the linearity in a range from $1.0{\times}10^{-6}$ M to $1.0{\times}10^{-5}$ M ergosterol.

Enrichment of Electrochemically Active Bacteria Using a Three-Electrode Electrochemical Cell

  • Yoon, Seok-Min;Choi, Chang-Ho;Kim, Mi-A;Hyun, Moon-Sik;Shin, Sung-Hye;Yi, Dong-Heui;Kim, Hyung-Joon
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.110-115
    • /
    • 2007
  • Electrochemically active bacteria were successfully enriched in an electrochemical cell using a positively poised working electrode. The positively poised working electrode (+0.7 V vs. Ag/AgCl) was used as an electron acceptor for enrichment and growth of electrochemically active bacteria. When activated sludge and synthetic wastewater were fed to the electrochemical cell, a gradual increase in amperometric current was observed. After a period of time in which the amperometric current was stabilized (generally 8 days), linear correlations between the amperometric signals from the electrochemical cell and added BOD (biochemical oxygen demand) concentrations were established. Cyclic voltammetry of the enriched electrode also showed prominent electrochemical activity. When the enriched electrodes were examined with electron microscopy and confocal scanning laser microscopy, a biofilm on the enriched electrode surface and bacterium-like particles were observed. These experimental results indicate that the electrochemical system in this study is a useful tool for the enrichment of an electrochemically active bacterial consortium and could be used as a novel microbial biosensor.

Spinach Root-Tissue Based Amperometric Biosensor for the Determination of Hydrogen Peroxide (시금치 뿌리 조직 바이오센서를 이용한 과산화수소의 정량)

  • Lee, Beom-Gyu;Yoon, Kil-Joong;Kwon, Hyo-Shik
    • Analytical Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.315-322
    • /
    • 2000
  • The response characteristics of the bioelectrode developed by the co-immobilization of spinach root tissue and ferrocene in a carbon paste matrix for the amperometric determination of hydrogen peroxide were evaluated. In the range of electrode potential examined (-0.3~0.0V vs. Ag/AgCl). the response time was relatively short ($t_{95%}=11.8$ sec) and it responded in the wide range of pH. Also, its detection limit was $2.25{\times}10^{-6}M$ (S/N=3) and a relative standard deviation of the measurements which were repeated 15 times using $1.0{\times}10^{-3}M$ hydrogen peroxide was 1.87%. The bioelectrode sensitivity decreased to 40% of the original value in 19 days of continuous use.

  • PDF