• Title/Summary/Keyword: Ammonia concentration

Search Result 1,140, Processing Time 0.039 seconds

Fermentative Bio-Hydrogen Production of Food Waste in the Presence of Different Concentrations of Salt (Na+) and Nitrogen

  • Lee, Pul-eip;Hwang, Yuhoon;Lee, Tae-jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.2
    • /
    • pp.283-291
    • /
    • 2019
  • Fermentation of food waste in the presence of different concentrations of salt ($Na^+$) and ammonia was conducted to investigate the interrelation of $Na^+$ and ammonia content in bio-hydrogen production. Analysis of the experimental results showed that peak hydrogen production differed according to the ammonia and $Na^+$ concentration. The peak hydrogen production levels achieved were (97.60, 91.94, and 49.31) ml/g COD at (291.41, 768.75, and 1,037.89) mg-N/L of ammonia and (600, 1,000, and 4,000) $mg-Na^+/L$ of salt concentration, respectively. At peak hydrogen production, the ammonia concentration increased along with increasing salt concentration in the medium. This means that for peak hydrogen production, the C/N ratio decreased with increasing salt content in the medium. The butyrate/acetate (B/A) ratio was higher in proportion to the bio-hydrogen production (r-square: 0.71, p-value: 0.0006). Different concentrations of $Na^+$ and ammonia in the medium also produced diverse microbial communities. Klebsiella sp., Enterobacter sp., and Clostridium sp. were predominant with high bio-hydrogen production, while Lactococcus sp. was found with low bio-hydrogen production.

Effect of Operating Condition of Stripping Process on Ammonia Removal for Pre-treatment of Swine Wastewater (축산폐수 전처리를 위한 암모니아 탈기공정의 운전조건이 암모니아 제거에 미치는 영향)

  • Whang, Gye-Dae;Cho, Young-Moo
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.1
    • /
    • pp.86-92
    • /
    • 2004
  • Lab-scale experiments have been carried out to investigate ammonia stripping with a modified spray tower for removing ammonia nitrogen from swine wastewater. The operating conditions such as initial pH, temperature, air flow, hole size of distributor determining the diameter of water drops, and influent solids concentration were closely examined focusing on removal efficiency of ammonia. As a result of the experiment, in order to achieve high rate of ammonia removal by the air stripping system, the air flow rate must be supplied at high rate with sufficiently high initial pH, temperature. The optimum operating condition to meet the residual ammonia concentration of 300 mg/L was the initial pH of 11.0 at $35^{\circ}C$ with the air flow rate of 20 L/min. It also showed that the smaller hole size is, the higher removal rate of ammonia is expected. However, when used a small sized distributor (2 mm), the flooding problem at the upper column occurred due to clogging of the hole. With regard to the influent solids concentration, it was showed that the lower concentration of solids, the higher removal rate of ammonia. The removal of particulate materials in influent led to improve the removal efficiency of ammonia, rather than to control the operating condition including initial pH, temperature, and air flow. The empirical correlation between KLa and operating parameters would be driven as, $K_{La}=(0.0003T-0.0047){\cdot}G^{0.3926}{\cdot}L^{-0.5169}{\cdot}C^{-0. 1849}$. The calculated $K_{La}$ from proposed formula can be used effectively to estimate the optimum reaction time and to calculate the volume of modified spray tower system.

Effects of Seed Sources and Concentration of Ammonia on Anaerobic Digestion (혐기성 소화에 대한 식종원 및 암모니아 농도의 영향)

  • Kim, Yang-Ji;Kim, Sung-Il;Shin, Bum-Shic;Ahn, Ki-Sup;Kim, Jong-Soo
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • The seeding sources and concentration of ammonia on anaerobic digestion were investigated by batch culture bioreactors. The sources of seeding on anaerobic digestion were from swine wastewater collection pit of a hog raising farm and from anaerobic digestion sludge of a municipal sewage treatment plant. The inhibition of ammonia on anaerobic microorganisms was initiated at ammonia concentration of $1,500\;mgNH_4-N/L$ and it's effect was increased by increased by increasing ammonia concentration up to $3,500\;mgNH_4-N/L$ regardless the sources of seeding as evidenced by decreases in COD removal efficiencies and biogas yields. The inhibition occurred to not only methanogens but also acidogens since the concentration of volatile fatty acids was maintained at 50 mg/L The COD removal efficiency and biogas yield were Maintained constantly while increasing ammonia concentration up to $3,500\;mgNH_4-N/L$ when swine wastewater collection pit was used as a seeding; however, those were decreased while increasing ammonia concentration when anaerobic digestion sludge was used as a seeding. The results indicate that the seeding acclimated to high concentrations of ammonia for long time was easy in adaptation to high ammonia concentration and less subjective to ammonia inhibitory effects.

Reduction of Ammonia Accumulation and Improvement of Cell Viability by Expression of Urea Cycle Enzymes in Chinese Hamster Ovary Cells

  • Chung, Myung-Il;Lim, Mi-Hee;Lee, Yun-Jeong;Kim, Ik-Hwan;Kim, Ick-Young;Kim, Jung-Hoe;Chang, Kern-Hee;Kim, Hong-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.2
    • /
    • pp.217-224
    • /
    • 2003
  • Previously, we developed a CHO cell line (CHO-OTC1-Al9) that expresses the first two enzymes in the urea cycle and exhibits a higher ammonia-removing ability and faster growth rate than a vector-controlled CHO cell line (CHO-neo-5). The current study was undertaken to develop a cell line with an ammonia-removing ability higher than the cell line developed previously. To accomplish this, CHO cell lines expressing the first three, first four, or all five enzymes of the urea cycle were constructed using a stable transfection method. Finally, the CHO-AS-16, CHO-AL-19, and CHO-Arg-11 cell lines expressing the first three, first four, and all five enzymes of the urea cycle, respectively, were selected and found to exhibit higher ammonia-removing ability than the CHO-OTC1-Al9 cell line. Among the three selected cell lines, CHO-AL-19 showed the highest ammonia-removing ability and highest cell viability at a higher cell density, with 40% and 15% lower ammonia concentration in the, culture media than that of CHO-neo-5 and CHO-OTC1-A19 cell lines, respectively. CHO-AL-19 also showed 44% and 10% higher cell viability than the CHO-neo-5 and CHO-OTC-Al9 cell lines, at a higher cell density, respectively. The ammonia concentrations in the culture media were expressed as the ammonia concentration/cell, and the CHO-AL-19 cells revealed 45-60% and 20% lower ammonia concentration/cell than the CHO-neo-5 and CHO-OTC1-Al9 cells, respectively.

Annual Distribution of Atmospheric Ammonia Concentration in Saemangum Reclaimed Land Area (새만금 간척지 지역 공기 중 암모니아 농도의 연간 분포)

  • Hong, Sung-Chang;Kim, Min-Wook;Kim, Jin-Ho
    • Korean Journal of Environmental Agriculture
    • /
    • v.40 no.4
    • /
    • pp.330-334
    • /
    • 2021
  • BACKGROUND: More recently, it has been shown that atmospheric ammonia (NH3) plays a primary role in the formation of secondary particulate matter by reacting with the acidic species, e.g. SO2, NOx, to form PM2.5 aerosols in the atmosphere. The Jeonbuk region is an area with high concentration of particulate matter. Due to environmental changes in the Saemangeum reclaimed land with an area of 219 km2, it is necessary to evaluate the impact of the particulate matter and atmospheric ammonia in the Jeonbuk region. METHODS AND RESULTS: Atmospheric ammonia concentrations were measured from June 2020 to May 2021 using a passive sampler and CRDS analyzer. Seasonal and annual atmospheric ammonia concentration measured using passive sampler was significantly lower in Jangjado (background concentration), and the concentration ranged from 11.4 ㎍/m3 to 18.2 ㎍/m3. Atmospheric ammonia concentrations in Buan, Gimje, Gunsan, and Wanju regions did not show a significant difference, although there was a slight seasonal difference. The maximum atmospheric ammonia concentration measured using the CRDS analyzer installed in the IAMS near the Saemangeum reclaimed land was 51.5 ㎍/m3 in autumn, 48.0 ㎍/m3 in summer, 37.6 ㎍/m3 in winter, and 32.7 ㎍/m3 in spring. The minimum concentration was 4.9 ㎍/m3 in spring, 4.2 ㎍/m3 in summer, and 3.5 ㎍/m3 in autumn and winter. The annual average concentration was 14.6 ㎍/m3. CONCLUSION(S): Long term monitoring of atmospheric ammonia in agricultural areas is required to evaluate the formation of fine particulate matter and its impact on the environment. In addition, continuous technology development is needed to reduce ammonia emitted from farmland.

Application for Measuring the Glucose, Ammonia nitrogen, and Tylosin Concentration using Near Infrared Spectroscopy

  • Kim, Jong-Soo;Cho, Hoon
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.2
    • /
    • pp.19-25
    • /
    • 2008
  • For measurement of tylosin, ammonia nitrogen, and glucose concentration during the culture of Streptomyces fradiae using Near Infrared Spectroscopy, the calibration using various mathematical models was performed and then, based on the linear model, the validation was carried out. In the case of sucrose concentration using the MLR method, the Standard Error of Prediction and Multiple correlation coefficient were 1.97, and 0.991, respectively. In the case of ammonia nitrogen concentration using the PLSR method, the Standard Error of Prediction and Multiple correlation coefficient were 0.13, and 0.990, respectively. In the case of tylosin concentration using the PLSR method, the standard Error of Prediction and Multiple correlation coefficient were 0.54, and 0.984, respectively.

Ammonia Effects on Anaerobic Digestion of Swine Wastewaters (양돈폐수의 혐기성 소화에 대한 암모니아의 영향)

  • Kim, Jong-Soo
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.10 no.1
    • /
    • pp.102-108
    • /
    • 2002
  • The effects of ammonia on mesophilic anaerobic digestion were investigated by operating lab-scale two-stage ASBF reactors using swine wastewaters as influent without and with ammonia removal at HRT of 1-2 days and OLR of $2.2{\sim}9.6kg-COD/m^3{\cdot}d$ for 250 days. The COD removal efficiency and biogas generation of two-stage ASBF reactors was decreased by increasing influent ammonia concentrations to 1,580 mg(T-N)/L with increasing OLR to $6.3kg-COD/m^3{\cdot}d$, while those were increased by maintaining influent ammonia concentrations below 340 mg(T-N)/L by MAP precipitation with increasing OLR to $9.6kg-COD/m^3{\cdot}d$. Initial inhibirion of ammonia on anaerobic processes was observed at a concentration of 760 mg(T-N)/L and the COD removal efficiency and biogas generation dropped to 1/2 at ammonia concentration ranges of 1,540~1,870 mg(T-N)/L. It is essential to remove ammonia in swine wastewaters to an initial inhibition level before anaerobic processes for the effective removal of COD.

  • PDF

Experimental Performance Study of the Bubble Pump for the Diffusion Absorption Refrigerating System (확산형 흡수식 냉동시스템의 기포펌프 성능실험)

  • 이재효;정의갑;윤재호;정의갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.287-292
    • /
    • 2004
  • An experimental investigation was carried out to study the performance of a bubble pump for the diffusion absorption refrigerating system. Ammonia was used as the refrigerant and the helium was charged in order to balance the pressure between the low and high pressure side. As experimental variables, the concentration of ammonia charged into system, heat input, and the pressure of helium were selected. Experimental results show that the generation rate of ammonia vapor and the circulation rate of diluted ammonia solution were increased as the heat input increases, but the ratio of the solution to vapor flow rate was decreased. The generation rate of refrigerant vapor and the circulation rate of diluted ammonia solution increased as the system pressure decreased. Finally under the condition of 25 bars, the concentration of rich ammonia solution was not affected by the generation rate of ammonia vapor and the circulation of diluted ammonia solution.

Estimation of Ammonia Flux and Emission Factor from Cattle Housing Using Dynamic Flux Chamber (Dynamic Flux Chamber를 이용한 소사육시설의 암모니아 플럭스 및 배출계수 평가)

  • Sa, Jae-Hwan;Jeon, Eui-Chan
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.1
    • /
    • pp.33-43
    • /
    • 2010
  • Atmospheric ammonia is a very important constituent of the environment because it is the dominant alkaline gaseous species present in the atmosphere. Ammonia is known to affect ecosystems at relatively low concentration. In this study flux profiles of ammonia emitted from the cattle housing were evaluated using a dynamic flux chamber (DFC). We have developed the emission factor of $NH_3$ from the cattle housing. Analysis of ammonia flux variation was made with respect to such variables as manure surface temperature, pH, and ammonium concentration. Ammonia flux has been measured up to summer in 2007 at calf and cattle housing. In the fall, average ammonia flux from calf and cattle housing was estimated as 1.406 (${\pm}0.947$) and 1.534 ((${\pm}0.956$) $mg\;m^2\;min^1$, respectively. In the winter, average ammonia flux was estimated 1.060 ((${\pm}0.569$) from the calf housing and 1.216 ((${\pm}0.655$) $mg\;m^2\;min^1$ from the cattle housing. The correlation coefficient (R=0.732) between ammonia flux and manure surface ammonium concentration exhibited stronger relationship than manure surface pH and temperature. In the fall, ammonia emission factor from calf and cattle housing was estimated as 3.94 ((${\pm}2.66$) and 11.41 ((${\pm}5.86$) kg-$NH_3$ animal$^1\;yr^1$, respectively. In the winter, ammonia average flux was estimated as 2.89 ((${\pm}1.59$) from the calf housing and 6.51 ((${\pm}3.67$) kg-$NH_3$ animal$^1\;yr^1$ from the cattle housing.

Exergy Analysis of Regenerative Ammonia-Water Rankine Cycle for Use of Low-Temperature Heat Source (저온열원 활용을 위한 암모니아-물 재생 랭킨사이클의 엑서지 해석)

  • Kim, Kyoung-Hoon;Ko, Hyung-Jong;Kim, Se-Woong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.1
    • /
    • pp.65-72
    • /
    • 2012
  • Rankine cycle using ammonia-water mixture as a working fluid has attracted much attention, since it may be a very useful device to extract power from low-temperature heat source. In this work, the thermodynamic performance of regenerative ammonia-water Rankine cycle is thoroughly investigated based on the second law of thermodynamics and exergy analysis, when the energy source is low-temperature heat source in the form of sensible energy. In analyzing the power cycle, several key system parameters such as ammonia mass concentration in the mixture and turbine inlet pressure are studied to examine their effects on the system performance including exergy destructions or anergies of system components, efficiencies based on the first and second laws of thermodynamics. The results show that as the ammonia concentration increases, exergy exhaust increases but exergy destruction at the heat exchanger increases. The second-law efficiency has an optimum value with respect to the ammonia concentration.