• Title/Summary/Keyword: Ambient measurement

Search Result 500, Processing Time 0.03 seconds

The Characteristic Change of Pressure and Differential Transmitter due to a Rapid Change of Ambient Temperature (주위 온도의 급격한 변화에 따른 압력 및 차압 전송기의 특성 변화)

  • Chung, Jong-Tae;Ha, Young-Cheol;Lee, Cheol-Gu;Her, Jae-Young
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.321-326
    • /
    • 2004
  • The pressure and differential pressure(DP) transmitters are used for gas flow rate calculation on the orifice gas metering system. On site, the pressure and DP transmitters are installed in a shelter to diminish the affects of environmental change such as an ambient temperature. But there has been an argument about the effectiveness of the shelter and this brought up the necessity to verify the affects of ambient temperature. These experiments were performed to verify the ambient temperature effects as observing the output of transmitters when the ambient temperature were changed from $-30^{\circ}C$ to $50^{\circ}C$. The results showed that the most of transmitters were operated in the spec range of performance criteria presented by manufacturer but the rapid change of ambient temperature could cause the larger measurement error for the DP transmitter of low span than others. Therefore the pressure and DP transmitters need to be operated and controlled within the proper range of ambient temperature.

  • PDF

Experimental Performance Verification of Load Carrying Capacity Algorithm of Bridges using Ambient Vibration (상시진동을 이용한 교량 내하력 추정 알고리즘의 실험적 성능 검증)

  • Lee, Woo-Sang;Park, Ki-Tae;Han, Sung-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.83-90
    • /
    • 2010
  • In this study, it is conducted that the performance verification of the ambient load carrying capacity algorithm using long-term measurement systems of bridges. For this purpose, a steel-box type model bridge is fabricated and the public load carrying capacity of a steel-box model bridge is estimated by conducting the numerical analysis and load test. In addition, we compare the public load carrying capacity with the estimated result of a steel-box model bridge using the ambient load carrying capacity algorithm. By the assessment result, it is shown that the estimated ambient load carrying capacity is the difference of approximately 6.0 percentages as compared with the public load carrying capacity.

The Analysis in Measurement Performance MEMS Sensor Through the Low-Noise Vibration Measurement APP (저노이즈형 진동계측 앱을 통한 MEMS 센서의 계측성능분석)

  • Jung, Young-Seok;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.1
    • /
    • pp.93-100
    • /
    • 2017
  • With increasing number construction of high-rise building which has about 40 to 60 floors there have been many kinds of problem which related with usage from vibration. To predict response acceleration, it is important to assess correct natural frequency. However, due to the noise of MEMS sensor, it is difficult to measure dynamic characteristic such as natural frequency when measuring ambient vibration using MEMS sensor within cell phone. Therefore, a comparative analysis on vibration measuring applications was performed after measuring ambient vibration of 2 skyscrappers which have height between 133.5~244.3m that are located in Seoul and Observation tower using I-jishin APP with noise reduction function of MEMS sensor in order to verify the effectiveness of low noise type vibration measurement APP.

Study on RDE (Real Driving Emission) Characteristic of Gasoline Vehicle Depending on the Ambient Temperature (대기 온도에 따른 가솔린 차량의 실도로 배출가스 특성 연구)

  • Kim, Hyun-Jin;Kim, Sung-Woo;Lee, Min-Ho;Kim, Ki-Ho;Lee, Jung-Min
    • Journal of ILASS-Korea
    • /
    • v.23 no.4
    • /
    • pp.221-226
    • /
    • 2018
  • Despite the increasingly stringent automotive emissions regulations, the impact of vehicle emissions on air pollution remains large. In addition, since the issue of emission of more exhaust gas than the exhaust gas measured in the test room when the vehicle passing the exhaust gas regulation standard is run on the actual road, many countries studied and introduced gas regulations about Real Driving Emission using Portable Emission Measurement System. At present, Korea regulations restrict the number of NOx and PN in diesel vehicles. In the case of gasoline vehicles, there is no regulation on emission gas, but there is a problem of continuing automobile exhaust gas problems and a large amount of gasoline GDI vehicle's PN emission. So research and interest are increasing due to this problem. In this study, characteristics of exhaust gas depending on changes of ambient temperature were analyzed among various factors affecting exhaust gas measurement of gasoline vehicles. As a result, at the low temperature test, the lower the ambient temperature, the more the exhaust gas was emitted. At ordinary temperature test, no specific tendency was observed due to changes of ambient temperature.

Analysis of Measurement Error for PM-10 Mass Concentration by Inter-Comparison Study (비교 측정을 통한 PM-10 질량농도의 오차 분석)

  • Jung, Chang-Hoon;Cho, Yang-Sung;Hwang, S.M.;Jung, Y.G.;Ryu, J.C.;Shin, D.S.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.689-698
    • /
    • 2007
  • Particular attention is paid to the validity of PM-10 measurement using beta attenuation method. In this study, the inter-comparison studies were undertaken for PM-10 sampler with different measuring methods. The three beta attenuation monitoring instruments (BAM1020, FH C-14, and DIGS-150) and filter based gravitational method using High Volume Air Sampler were collocated and mass concentrations were compared from August to November, 2006. The results of the investigation show that beta attenuation monitoring instruments are comparable with gravitational method within 10% of measurement error. For specific conditions under high humidity and high concentrations, the inter-comparison results also showed a relatively good agreement and this can be explained as the effect of inlet heating of beta attenuation instrument. Subsequently, this study shows that beta attenuation monitoring instruments can be equivalently used with reasonable validity when compared gravimetric method.

Characteristic in Mg-doped p-type GaN changing activation temperature in $N_2$ gas ambient

  • Lee, Sung-Ho;Kim, Chul-Joo;Seo, Yong-Gon;Seo, Mun-Suek;Hwang, Sung-Min
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.113-114
    • /
    • 2008
  • Conventional furnace annealing (CFA) for activating Mg-doped p-type GaN films had been performed in pure $N_2$ ambient. All sample activated the same gas ambient. The annealing process change temperature: the first process is performed at $550^{\circ}C$ for 10 min. but, the first process is the same bulk. From second to five process increase activation temperature to change $50^{\circ}C$ and annealing time keeping for 10 min. It is found that the samples characteristic measure hall measurement. Similar results were also evidenced by photoluminescence (PL) measurement.

  • PDF

Comparison of the Natural Period Obtained by Eigenvalue Analysis and Ambient Vibration Measurement in Bearing-Wall Type Apartment (고유치해석과 진동계측을 통한 벽식 공동주택의 고유주기 비교)

  • Yoon, Sung-Won;Jeong, Sug-Chang;Lim, In-Sik
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.43-50
    • /
    • 2006
  • This paper is concerned with the natural periods of ambient vibration and eigenvalue analysis. Ambient vibration tests were conducted to four bearing-wall reinforced concrete buildings ranging from twelve to nineteen stories. The performance of modeling in eigenvalue analysis was investigated using consideration of rigidity out of the plane in the slab and the non-structural bearing wall. Measured natural period was also compared with the value by the KBC2005. Natural period of the short direction in eigenvalue analysis is well fitted with the measured one. In the other hand, Natural period of the long direction in eigenvalue analysis is slightly more overestimated than the measured one. Natural period of the long direction in eigenvalue analysis was found to be enhanced by considering the effect of the stiffness out of the plane of the slab and non-structural wall in the structural modeling.

  • PDF

Natural Frequency of Tall Building Through Ambient Vibration Measurement (고층건물의 상시진동계측을 통한 고유진동수)

  • Yoon, Sung Won;Ju, Young Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.2
    • /
    • pp.117-124
    • /
    • 2003
  • Wind-induced motions, like acceleration for instance, often influence designs for high-rise buildings. As a consequence, correct assessment of natural frequency becomes important. The empirical expressions used to quantify this parameter at the design phase tend to yield values that are significantly different from each other. This paper is concerned with the natural periods of steel buildings. It describes the vibration measurement methods that were employed for testing buildings. This paper will also present reliable methods of assessing the natural period from ambient vibration tests. Data from measurements on 21 buildings in Seoul were provided while 21 buildings were tested by ambient vibration measurements to obtain the natural periods. While regression formulas of natural periods for steel-frarried tall buildings were suggested,the obtained formula was compared with the empirical expressions of structural standards and the Eigen-value analysis.

Drop Size Measurement using Image Processing Method under High Ambient Pressure Condition (고압환경에서 이미지 프로세싱 기법을 이용한 액적크기 측정)

  • Lim Byoungjik;Khil Taeock;Jung Kihoon;Yoon Youngbin
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.111-114
    • /
    • 2003
  • Drop size is one of the most important parameters which are control the performance of the engine using liquid fuel/oxidizer and drop formation is mainly controlled by aerodynamic force caused by ambient gas. Because of this, empirical data and correlation acquired under standard ambient condition are not valid. So experiments under high ambient pressure condition to measure the drop size using image processing method And find the empirical correlation between SMD and chamber pressure(density), injection velocity.

  • PDF

Identification of Underwater Ambient Noise Sources Using Hilbert-Huang Transfer (힐버트-후앙 변환을 이용한 수중소음원의 식별)

  • Hwang, Do-Jin;Kim, Jea-Soo
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.30-36
    • /
    • 2008
  • Underwater ambient noise originating from geophysical, biological, and man-made acoustic sources contains information on the source and the ocean environment. Such noise affectsthe performance of sonar equipment. In this paper, three steps are used to identify the ambient noise source, detection, feature extraction, and similarity measurement. First, we use the zero-crossing rate to detect the ambient noisesource from background noise. Then, a set of feature vectors is proposed forthe ambient noise source using the Hilbert-Huang transform and the Karhunen-Loeve transform. Finally, the Euclidean distance is used to measure the similarity between the standard feature vector and the feature vector of the unknown ambient noise source. The developed algorithm is applied to the observed ocean data, and the results are presented and discussed.