• Title/Summary/Keyword: Alveolar sound

Search Result 39, Processing Time 0.023 seconds

Coda Sounds Acquisition at Word Medial Position in Three and Four Year Old Children's Spontaneous Speech (자발화에 나타난 3-4세 아동의 어중종성 습득)

  • Woo, Hyekyeong;Kim, Soojin
    • Phonetics and Speech Sciences
    • /
    • v.5 no.3
    • /
    • pp.73-81
    • /
    • 2013
  • Coda in the word-medial position plays an important role in acquisition of our speech. Accuracy of the coda in the word-medial position is important as a diagnostic indicator since it has a close relationship with degrees of disorder. Coda in the word-medial position only appears in condition of connecting two vowels and the sequence causes diverse phonological processes to happen. The coda in the word-medial position differs in production difficulty by the initial sound in the sequence. Accordingly, this study aims to examine the tendency of producing a coda in the word-medial position with consideration of an optional phonological process in spontaneous speech of three and four year old children. Data was collected from 24 children (four groups by age) without speech and language delay. The results of the study are as follows: 1) Sonorant coda in the word-medial position showed a high production frequency in manner of articulation, and alveolar in place of articulation. When the coda in the word-medial position is connected to an initial sound in the same place of articulation, it revealed a high frequency of production. 2) The coda in word-medial position followed by an initial alveolar stop revealed a high error rate. Error patterns showed regressive assimilation predominantly. 3) The order of difficulty that Children had producing codas in the word-medial position was $/k^{\neg}/$, $/p^{\neg}/$, /m/, /n/, /ŋ/ and /l/. Those results suggest that in targeting coda in the word-medial position for evaluation, we should consider optional phonological process as well as the following initial sound. Further studies would be necessary which codas in the word-medial position will be used for therapeutic purpose.

An Acoustic Study of Korean and English Voiceless Sibilant Fricatives

  • Sung, Eun-Kyung;Cho, Yun-Jeong
    • Phonetics and Speech Sciences
    • /
    • v.2 no.3
    • /
    • pp.37-46
    • /
    • 2010
  • This study investigates acoustic characteristics of English and Korean voiceless sibilant fricatives as they appear before the three vowels, /i/, /$\alpha$/ and /u/. Three measurements - duration, center of gravity and major spectral peak - are employed to compare acoustic properties and vowel effect for each fricative sound. This study also investigates the question of whether Korean sibilant fricatives are acoustically similar to the English voiceless alveolar fricative /s/ or to the palato-alveolar /$\int$/. The results show that in the duration of frication noise, English /$\int$/ is the longest and Korean lax /s/ the shortest of the four sounds. It is also observed that English alveolar /s/ has the highest value, whereas Korean /s/ shows the lowest value in the frequency of center of gravity. In terms of major spectral peak, while English /s/ reveals the highest frequency, English /$\int$/ shows the lowest value. In addition, evidence indicates that there is a strong vowel effect in the fricative sounds of both languages, although the vowel effect patterns of the two languages are inconsistent. For instance, in the major spectral peak, both Korean lax /s/ and tense /$s^*$/ show significantly higher frequencies before the vowel /$\alpha$/ than before the other vowels, whereas both English /s/ and /$\int$/ exhibit significantly higher frequencies before the vowel /i/ than before the other vowels. These results indicate that Korean sibilant fricatives are acoustically distinct from both English /s/ and /$\int$/.

  • PDF

EXPERIMENTAL STUDY OF ALVEOLAR BONE WALL DEFECTS USING DIRECT DIGITAL RADIOGRAPHY (디지털방사선촬영법을 이용한 치조골벽 소실에 관한 실험적 연구)

  • Song Nam-Kyu;Koh Kwang-Joon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.49-61
    • /
    • 1997
  • The purpose of this study was to compare E-speed film, CDR, and modified CDR images by means of observing some artificial defects of alveolar bone wall in the sound human dried mandibles. High diagnostic accuracy was shown in 1 wall and 4 wall defects by all 5 observers (2 Radiologists, 2 Periodontists, 1 General practitioner), but the diagnosis in 2 wall and 3 wall defects was inaccurate. Modified CDR images had the more diagnostic accuracy than E-speed film and CDR images, but there was no statistical difference among them. Finally, radiologist used modified CDR images more than others and used equalization effect more than the change in contrast and/or brightness.

  • PDF

Effect of Low Intensity Sound Wave on UC-MSC(Umbilical Cord Mesenchymal Stem Cell Growth (저강도 음파 조사가 중간엽 줄기세포 증식에 미치는 영향)

  • Kim, Sung-Min;Kang, Seung-Ho;Jeong, Jae-Hoon;Park, Jung-Keug;Kim, Soo-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.4
    • /
    • pp.521-525
    • /
    • 2011
  • It is known that the low-intensity sound stimulation really affect to grow the cell. The cellular growth mechanism, however, does not been clearly identified even the effect on the low-intensity sound stimulation. The purpose of this study is to investigate the effect of low-intensity sound stimulation on the alveolar UC-MSC proliferation. Before the low-intensity sound stimulation is applied, the UC-MSC are cultured for 24 hours to facilitate their attachments. The cells are divided into two groups. And each was exposed to a medium with or without the low-intensity ultrasound stimulation at 71dB intensity level. The UC-MSC are again divided into three treatment groups of group 1, 2, and 3 and exposed to a frequency at 50Hz, 100Hz, and 1000Hz, respectively. In the results, it is investigated that the growth rates of UC-MSC for the stimulated groups were higher than those of control groups. In 1000Hz frequency, the number of UC-MSC cell is significantly higher than control groups (p>0.05). We would put the hypothesis that the cell growth could be enhanced by an appropriate low-intensity sound stimulation.

Comparison of error characteristics of final consonant at word-medial position between children with functional articulation disorder and normal children (기능적 조음장애아동과 일반아동의 어중자음 연쇄조건에서 나타나는 어중종성 오류 특성 비교)

  • Lee, Ran;Lee, Eunju
    • Phonetics and Speech Sciences
    • /
    • v.7 no.2
    • /
    • pp.19-28
    • /
    • 2015
  • This study investigated final consonant error characteristics at word-medial position in children with functional articulation disorder. Data was collected from 11 children with functional articulation and 11 normal children, ages 4 to 5. The speech samples were collected from a naming test. Seventy-five words with every possible bi-consonants matrix at the word-medial position were used. The results of this study were as follows : First, percentage of correct word-medial final consonants of functional articulation disorder was lower than normal children. Second, there were significant differences between two groups in omission, substitution and assimilation error. Children with functional articulation disorder showed a high frequency of omission and regressive assimilation error, especially alveolarization in regressive assimilation error most. However, normal children showed a high frequency of regressive assimilation error, especially bilabialization in regressive assimilation error most. Finally, the results of error analysis according to articulation manner, articulation place and phonation type of consonants of initial consonant at word-medial, both functional articulation disorder and normal children showed a high error rate in stop sound-stop sound condition. The error rate of final consonant at word-medial position was high when initial consonant at word-medial position was alveolar sound and alveopalatal sound. Futhermore, when initial sounds were fortis and aspirated sounds, more errors occurred than linis sound was initial sound. The results of this study provided practical error characteristics of final consonant at word-medial position in children with speech sound disorder.

DIGITAL IMAGE PROCESSING AND CLINICAL APPLICATION OF VIDEODENSITOMETER (실험적으로 제작한 Videodensitometer의 디지털 영상처리와 임상적 적용에 관한 연구)

  • Park Kwan-Soo;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.273-282
    • /
    • 1992
  • The purpose of this study was to propose the utility which was evaluated the digital image processing and clinical application of the videodensitomery. The experiments were performed with IBM-PC/16bit-AT compatible, video camera(CCdtr55, Sony Co., Japan), an color monitor(MultiSync 3D, NEC, Japan) providing the resolution of 512×480 and 64 levels of gray. Sylvia Image Capture Board for the ADC(analog to digital converter) was used, composed of digitized image from digital signal and the radiographic density was measured by 256 level of gray. The periapical radiograph(Ektaspeed EP-21, Kodak Co., U. S. A) which was radiographed dried human mandible by exposure condition of 70 kVp and 48 impulses, was used for primary X-ray detector. And them evaluated for digitzed image by low and high pass filtering, correlations between aluminum equivalent values and the thickness of aluminum step wedge, aluminum equivalent values of sound enamel, dentin, and alveolar bone, the range of diffuse density for gray level ranging from 0 to 255. The obtained results were as follows: 1. The edge between aluminum steps of digitized image were somewhat blurred by low pass filtering, but edge enhancement could be resulted by high pass filtering. Expecially, edge enhancement between distal root of lower left 2nd molar and alveolar lamina dura was observed. 2. The correlation between aluminum equivalent values and the thickness of aluminum step wedge was intimated, yielding the coefficient of correlation r=0.9997(p<0.00l), the regression line was described by Y=0.9699X+0.456, and coefficient of variation amounting to 1.5%. 3. The aluminum equivalent values of sound enamel, dentin, and alvolar bone were 15.41㎜, 12.48㎜, 10.35㎜, respectively. 4. The range of diffuse density for gray level ranging from 0 to 255 was wider enough than that of photodenstiometer to be within the range of 1-4.9.

  • PDF

Alterations of Mucosal Vibration of True Vocal Folds on Tongue-Tip Trill : Preliminary Study Using the Electroglottography (Trill 발성시 전기성문파 측정검사로 분석한 성대점막 진동의 변화 : 예비연구)

  • 진성민;반재호;김남훈;이경철;권기환;이용배
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.11 no.1
    • /
    • pp.76-80
    • /
    • 2000
  • Tongue-tip trill is a sound made by the tongue tip making contract with the alveolar ridge and oscillating rapidly as sound is produced. It is an exercise used by many singers to warm up the voice and used as one of the methods of voice rehabilitation for patients who have the vocal folds scarred postoperatively and also who present with a variety of disorders, particularly hypofunction and presbyphonia. We intended to investigate the mucosal vibration of the true vocal folds on tongue-tip trill by electroglottography and to find e effective methods of tongue-tip trill. One adult male volunteer participated. Spectrography and electroglottography were checked repeatedly 15 times, more than 5 second in each times, at same pitch, in three conditions of phonation : sustained /a/ vowel, anterior trill in which tongue-tip vibrated at anterior portion of alveolar ridge just behind the anterior tooth, and posterior trill in which at palatal crest behind the transverse palatine fold We measured the first and second formant to determine indirectly the position of tongue and calculated speed quotient and the ratio of closing phase to closed phase. Speed quotients of posterior trill were higher than sustained /a/ vowel and anterior trill in 14 times. The ratio of closing phase to dosed phase of posterior trill were lower than the others in 14 times. Mucosa of true vocal folds is vibrated more effectively on posterior trill rather than sustained /a/ vowel and anterior trill. So, when tongue-tip trill is used as a method of voice rehabilitation, we suggest that posterior trill is better in producing effective mucosal vibration

  • PDF

Pain perception and efficacy of local analgesia using 2% lignocaine, buffered lignocaine, and 4% articaine in pediatric dental procedures

  • Afsal, M.M;Khatri, Amit;Kalra, Namita;Tyagi, Rishi;Khandelwal, Deepak
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.19 no.2
    • /
    • pp.101-109
    • /
    • 2019
  • Background: The purpose of this study was to compare the pain perception and anesthetic efficacy of 2% lignocaine with 1:200,000 epinephrine, buffered lignocaine, and 4% articaine with 1:200,000 epinephrine for the inferior alveolar nerve block. Methods: This was a double-blind crossover study involving 48 children aged 5-10 years, who received three inferior alveolar nerve block injections in three appointments scheduled one week apart from the next. Pain on injection was assessed using the Wong-Baker Faces pain scale and the sound eye motor scale (SEM). Efficacy of anesthesia was assessed by subjective (tingling or numbness of the lip, tongue, and corner of mouth) and objective signs (pain on probing). Results: Pain perception on injection assessed with Wong-Baker scale was significantly different between buffered lignocaine and lignocaine (P < 0.001) and between buffered lignocaine and articaine (P = 0.041). The onset of anesthesia was lowest for buffered lignocaine, with a statistically significant difference between buffered lignocaine and lignocaine (P < 0.001). Moreover, the efficacy of local analgesia assessed using objective signs was significantly different between buffered lignocaine and lignocaine (P < 0.001) and between lignocaine and articaine. Conclusion: Buffered lignocaine was the least painful and the most efficacious anesthetic agent during the inferior alveolar nerve block injection in 5-10-year-old patients.

DentalVibe versus lignocaine hydrochloride 2% gel in pain reduction during inferior alveolar nerve block in children

  • Menni, Alekhya Chowdary;Radhakrishna, Ambati Naga;Prasad, M. Ghanashyam
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.6
    • /
    • pp.397-402
    • /
    • 2020
  • Background: Inferior alveolar nerve block (IANB) is the most common, painful, and anxiety-provoking procedure involving needle insertion for anesthetic solution deposition. DentalVibeⓇ (DV) delivers vibration at a sustained frequency as a counter-stimulation to the site of injection, thereby alleviating pain. The aim of this study was to evaluate and compare the effectiveness of DV and lignocaine hydrochloride 2% gel (Lox 2% jelly) in pain reduction during IANB in children. Methods: A split-mouth randomized clinical trial was designed with a sample of 60 children (age, 6 to 12 years) requiring bilateral IANB for various dental procedures; DV was used while administering IANB and Lox 2% jelly was used as the topical anesthetic before administering IANB at subsequent appointments. During both appointments, pain perception was measured using the sound, eye, motor (SEM) scale and Wong-Baker faces pain rating scale (WBFPRS); oxygen saturation (SpO2) and pulse rate were measured using a pulse oximeter before, during, and after the IANB procedure. The obtained values were tabulated and subjected to statistical analysis. Wilcoxon test was used for intergroup comparison, and Friedman test, for intragroup comparison of measured variables at different treatment phases. Results: The medians and interquartile ranges of the WBFPRS scores recorded during the IANB procedure for DV and Lox 2% jelly were 2 (2-4) and 2 (0-2), respectively (P < 0.05). The SEM scale scores, mean SpO2, and pulse rate did not show any significant differences during the IANB procedure between both treatments. Conclusion: Both DV and Lox 2% jelly were found to be effective in pain reduction during IANB in children.

Spectral moment analysis of distortion errors in alveolar fricatives in Korean children (치조 마찰음 왜곡 오류 유무에 따른 아동 발화 적률분석 비교)

  • Yunju Han;Do Hyung Kim;Ja Eun Hwang;Dae-Hyun Jang;Jae Won Kim
    • Phonetics and Speech Sciences
    • /
    • v.16 no.1
    • /
    • pp.33-40
    • /
    • 2024
  • This study investigated acoustic features in spectral moment analysis, comparing accurate articulations with distortions of alveolar fricatives such as dentalization, palatalization, and lateralization. A retrospective analysis was conducted on speech samples from 61 children (mean age: 5.6±1.5 years, 19 females, 42 males) using the Assessment of Phonology & Articulation for Children (APAC) and Urimal-test of Articulation and Phonology I (U-TAP I). Spectral moment analysis was applied to 169 speech samples. The results revealed that the center of gravity of accurate articulations was higher than that of palatalization, while palatalization was lower than dentalization. The variance of dentalization was higher than that of both accurate articulations and palatalization. The skewness of dentalization was higher than that of accurate articulations, and the skewness of palatalization was higher than that of accurate articulations. The kurtosis of palatalization was higher than that of both accurate articulations and dentalization. No significant differences were observed for the position of fricatives (initial, medial) and tense type (plain, tense) across all variables of spectral moment analysis for each distortion type. This study confirmed distinct patterns in center of gravity, variance, skewness, and kurtosis depending on the type of alveolar fricative distortion. The objective values provided in this study will serve as foundational data for diagnosing alveolar fricative distortions in children with speech sound disorders.