EXPERIMENTAL STUDY OF ALVEOLAR BONE WALL DEFECTS USING DIRECT DIGITAL RADIOGRAPHY

디지털방사선촬영법을 이용한 치조골벽 소실에 관한 실험적 연구

  • Song Nam-Kyu (Department of Oral and Maxillofacial Radiology, College of Dentistry, Chunbuk National University) ;
  • Koh Kwang-Joon (Department of Oral and Maxillofacial Radiology, College of Dentistry, Chunbuk National University)
  • 송남규 (전북대학교 치과대학 구강악안면방사선학 교실) ;
  • 고광준 (전북대학교 치과대학 구강악안면방사선학 교실)
  • Published : 1997.08.01

Abstract

The purpose of this study was to compare E-speed film, CDR, and modified CDR images by means of observing some artificial defects of alveolar bone wall in the sound human dried mandibles. High diagnostic accuracy was shown in 1 wall and 4 wall defects by all 5 observers (2 Radiologists, 2 Periodontists, 1 General practitioner), but the diagnosis in 2 wall and 3 wall defects was inaccurate. Modified CDR images had the more diagnostic accuracy than E-speed film and CDR images, but there was no statistical difference among them. Finally, radiologist used modified CDR images more than others and used equalization effect more than the change in contrast and/or brightness.