• Title/Summary/Keyword: Aluminum-26

Search Result 294, Processing Time 0.019 seconds

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

TEMPERATURE CHANGE IN THE PULP ACCORDING TO POLISHING CONDITION OF VARIOUS RESTORATIVE MATERIALS (여러가지 수복물의 polishing조건에 따른 치수 온도변화)

  • Baik, Byeong-Ju;Park, Jong-Ha;Yang, Jeong-Suk;Lee, Seung-Young;Kim, Jae-Gon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.365-376
    • /
    • 1999
  • The importance of finishing and polishing the restoration has been described by several authors. The final step provides for improved metallurgical properties, better marginal adaptation, reduced plaque accumulation. Unfortunately, finishing of the restorations can produce damage from temperature rises at the pulpal wall. The aim of this study was to determine the changes in temperature can be occurred during the use of finishing and polishing instruments under a variety of conditions. ; with or without a water coolant, intermittent or continuous operation, high or low rotation speed, remaining dentin thickness and various restorative materials. Class V preparations were cut on extracted molars and restored with composite resin(Z 100), resin-modified glass ionomer cements(Dyract, Fuji II LC), and amalgam. Finishing was done with aluminum oxide coated disc($Sof-lex^{(R)}$ polishing disc, 3M, USA). The following results were obtained. 1. The rise of temperature during polishing of amalgam restorations was the highest among the all experimental groups except polishing with water coolant(P<0.05). However, there were no statistical differences in temperature rises between Z 100, Dyract and Fuji II LC(P>0.05). 2. The intrapulpal temperature was greatly influenced by the applied time, and intermittent polishing was showed significantly lower temperature rises than continuous polishing(P<0.01). 3. The intrapulpal temperature was increased according to the application of polishing regard less of using water coolant. However, polishing with water coolant showed significantly lower temperature in the pulp than not used water coolant(P<0.01).

  • PDF

A Study on Electron Dose Distribution of Cones for Intraoperative Radiation Therapy (수술중 전자선치료에 있어서 선량분포에 관한 연구)

  • Kang, Wee-Saing;Ha, Sung-Whan;Yun, Hyong-Geun
    • Progress in Medical Physics
    • /
    • v.3 no.2
    • /
    • pp.1-12
    • /
    • 1992
  • For intraoperative radiation therapy using electron beams, a cone system to deliver a large dose to the tumor during surgical operation and to save the surrounding normal tissue should be developed and dosimetry for the cone system is necessary to find proper X-ray collimator setting as well as to get useful data for clinical use. We developed a docking type of a cone system consisting of two parts made of aluminum: holder and cone. The cones which range from 4cm to 9cm with 1cm step at 100cm SSD of photon beam are 28cm long circular tubular cylinders. The system has two 26cm long holders: one for the cones larger than or equal to 7cm diamter and another for the smaller ones than 7cm. On the side of the holder is an aperture for insertion of a lamp and mirror to observe treatment field. Depth dose curve. dose profile and output factor at dept of dose maximum. and dose distribution in water for each cone size were measured with a p-type silicone detector controlled by a linear scanner for several extra opening of X-ray collimators. For a combination of electron energy and cone size, the opening of the X-ray collimator was caused to the surface dose, depths of dose maximum and 80%, dose profile and output factor. The variation of the output factor was the most remarkable. The output factors of 9MeV electron, as an example, range from 0.637 to 1.549. The opening of X-ray collimators would cause the quantity of scattered electrons coming to the IORT cone system. which in turn would change the dose distribution as well as the output factor. Dosimetry for an IORT cone system is inevitable to minimize uncertainty in the clinical use.

  • PDF

The Monitoring on Plasticizers and Heavy Metals in Teabags (침출용 티백 포장재의 안전성에 관한 연구)

  • Eom, Mi-Ok;Kwak, In-Shin;Kang, Kil-Jin;Jeon, Dae-Hoon;Kim, Hyung-Il;Sung, Jun-Hyun;Choi, Hee-Jung;Lee, Young-Ja
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.231-237
    • /
    • 2006
  • Nowadays the teabag is worldwide used for various products including green tea, tea, coffee, etc. since it is convenient for use. In case of outer packaging printed, however, there is a possibility that the plasticizers which is used for improvement in adhesiveness of printing ink may shift to inner tea bag. In this study, in order to monitor residual levels of plasticizers in teabags, we have established the simultaneous analysis method of 9 phthalates and 7 adipates plasticizers using gas chromatography (GC). These compounds were also confirmed using gas chromatography-mass spectrometry (GC-MSD). The recoveries of plasticizers analyzed by GC ranged from 82.7% to 104.6% with coefficient of variation of $0.6\sim2.7%$ and the correlation coefficients of each plasticizer was $0.9991\sim0.9999$. Therefore this simultaneous analysis method was showed excellent reproducibility and linearity. And limit of detection (LOD) and limit of quantitation (LOQ) on individual plasticizer were $0.1\sim3.5\;ppm\;and\;0.3\sim11.5\;ppm$ respectively. When 143 commercial products of teabag were monitored, no plasticizers analysed were detected in filter of teabag products. The migration into $95^{\circ}C$ water as food was also examined and the 16 plasticizers are not detected. In addition we carried out analysis of heavy metals, lead (Pb), cadmium (Cd), arsenic (As) and aluminum (Al) in teabag filters using ICP/AES. $Trace\sim23{\mu}g$ Pb per teabag and $0.6\sim1718{\mu}g$ Al per teabag were detected in materials of samples and Cd and As are detected less than LOQ (0.05 ppm). The migration levels of Pb and Al from teabag filter to $95^{\circ}C$ water were upto $11.5{\mu}g\;and\;20.8{\mu}g$ per teabag, respectively and Cd and As were not detected in exudate water of all samples. Collectively, these results suggest that there is no safety concern from using teabag filter.