여러가지 수복물의 polishing조건에 따른 치수 온도변화

TEMPERATURE CHANGE IN THE PULP ACCORDING TO POLISHING CONDITION OF VARIOUS RESTORATIVE MATERIALS

  • 백병주 (전북대학교 치과대학 소아치과학교실 및 구강생체과학연구소) ;
  • 박종하 (전북대학교 치과대학 소아치과학교실 및 구강생체과학연구소) ;
  • 양정숙 (전북대학교 치과대학 소아치과학교실 및 구강생체과학연구소) ;
  • 이승영 (전북대학교 치과대학 소아치과학교실 및 구강생체과학연구소) ;
  • 김재곤 (전북대학교 치과대학 소아치과학교실 및 구강생체과학연구소)
  • Baik, Byeong-Ju (Department of Pediatric Dentistry and Institute of Oral Bioscience, College of Dentistry, Chonbuk National University) ;
  • Park, Jong-Ha (Department of Pediatric Dentistry and Institute of Oral Bioscience, College of Dentistry, Chonbuk National University) ;
  • Yang, Jeong-Suk (Department of Pediatric Dentistry and Institute of Oral Bioscience, College of Dentistry, Chonbuk National University) ;
  • Lee, Seung-Young (Department of Pediatric Dentistry and Institute of Oral Bioscience, College of Dentistry, Chonbuk National University) ;
  • Kim, Jae-Gon (Department of Pediatric Dentistry and Institute of Oral Bioscience, College of Dentistry, Chonbuk National University)
  • 발행 : 1999.05.31

초록

수복물의 연마의 중요성에 대하여 많은 연구들이 이루어져 왔으며, 이는 수복물의 금속성질의 개선, 변연적합성의 증가 그리고 치태축적의 감소 등을 이유로 시행된다. 그러나 불행하게도 수복물에 대한 연마시 열의 발생으로 인하여 치수부위에 손상을 초래하므로 열의 발생을 최소화하려는 노력이 뒤따라야 할 것이다. 이에 본 연구에서는 수복물의 연마시 회전속도의 차이, 냉각제의 적용 유무, 여러 종류의 수복물의 차이, 간헐적인 연마와 연속적인 연마의 차이 그리고 잔존 상아질의 두께의 정도에 따른 치수내부에서의 열의 변화를 알아보기 위하여 발거된 구치에 5급 와동을 형성한 후 복합레진(Z100, 3M co), resin-modified GIC(Dyract, Fuji II LC) 그리고 아말감(Degussa) 등으로 충전하였으며, 다양한 조건에서의 연마를 시행, 치수내부에서의 열의 변화를 측정하여 다음과 같은 결과를 얻었다. 1. Amalgam을 건조한 상태에서 연마시 다른 재료에 비해 가장 큰 치수내 온도 상승을 보였다(P<0.05). 그러나, Z100, Dyract Fuji II LC 간에는 간헐적 수복물 연마와 연속적인 수복물 연마 모두 어떤 경우든 유의차가 없었다(P>0.05). 2. 같은 조건으로 연마를 시행했을 때, 간헐적인 연마보다 연속적인 연마를 한 경우가 치수내 온도가 더 크게 상승하였다(P<0.01). 3. 아말감과 Dyract 에 있어서는 잔존 상아질의 차이에 따른 치수내 온도변화에 유의한 차이를 보였으나(P<0.01), Fuji II LC에 있어서는 유의성이 없었다(P>0.05). 4. 냉각제의 유무에는 관계없이 어떤 경우든 시간에 따른 온도 상승을 보였다. 그러나, 냉각제를 사용한 경우가 냉각제를 사용하지 않은 경우에 비해 온도 상승값이 훨씬 작았다(P<0.01).

The importance of finishing and polishing the restoration has been described by several authors. The final step provides for improved metallurgical properties, better marginal adaptation, reduced plaque accumulation. Unfortunately, finishing of the restorations can produce damage from temperature rises at the pulpal wall. The aim of this study was to determine the changes in temperature can be occurred during the use of finishing and polishing instruments under a variety of conditions. ; with or without a water coolant, intermittent or continuous operation, high or low rotation speed, remaining dentin thickness and various restorative materials. Class V preparations were cut on extracted molars and restored with composite resin(Z 100), resin-modified glass ionomer cements(Dyract, Fuji II LC), and amalgam. Finishing was done with aluminum oxide coated disc($Sof-lex^{(R)}$ polishing disc, 3M, USA). The following results were obtained. 1. The rise of temperature during polishing of amalgam restorations was the highest among the all experimental groups except polishing with water coolant(P<0.05). However, there were no statistical differences in temperature rises between Z 100, Dyract and Fuji II LC(P>0.05). 2. The intrapulpal temperature was greatly influenced by the applied time, and intermittent polishing was showed significantly lower temperature rises than continuous polishing(P<0.01). 3. The intrapulpal temperature was increased according to the application of polishing regard less of using water coolant. However, polishing with water coolant showed significantly lower temperature in the pulp than not used water coolant(P<0.01).

키워드