• 제목/요약/키워드: All-in-one dentin adhesive

검색결과 86건 처리시간 0.036초

Pull-out bond strength of a self-adhesive resin cement to NaOCl-treated root dentin: effect of antioxidizing agents

  • Khoroushi, Maryam;Kachuei, Marzieh
    • Restorative Dentistry and Endodontics
    • /
    • 제39권2호
    • /
    • pp.95-103
    • /
    • 2014
  • Objectives: This study evaluated the effect of three antioxidizing agents on pullout bond strengths of dentin treated with sodium hypochlorite. Materials and Methods: Root canals of 75 single-rooted human teeth were prepared. Fifteen teeth were irrigated with normal saline for a negative control group, and the remaining 60 teeth (groups 2 - 5) with 2.5% NaOCl. The teeth in group 2 served as a positive control. Prior to post cementation, the root canals in groups 3 - 5 were irrigated with three antioxidizing agents including 10% rosmarinic acid (RA, Baridge essence), 10% hesperidin (HPN, Sigma), and 10% sodium ascorbate hydrogel (SA, AppliChem). Seventy-five spreaders (#55, taper .02, Produits Dentaires S.A) were coated with silica and silanized with the Rocatec system and ceramic bond. All the prepared spreaders were cemented with a self-adhesive resin cement (Bifix SE, Voco Gmbh) in the prepared canals. After storage in distilled water (24 h/$37^{\circ}C$), the spreaders were pulled out in a universal testing machine at a crosshead speed of 1.0 mm/min. Pull-out strength values were analyzed by one-way ANOVA and Tukey's HSD test (${\alpha}$ = 0.05). Results: There were significant differences between study groups (p = 0.016). The highest pullout strength was related to the SA group. The lowest strength was obtained in the positive control group. Conclusions: Irrigation with NaOCl during canal preparation decreased bond strength of resin cement to root dentin. Amongst the antioxidants tested, SA had superior results in reversing the diminishing effect of NaOCl irrigation on the bond strength to root dentin.

생체막 제거 방법에 따른 비우식성 치경부 병소의 미세인장강도 비교 (Comparison of microtensile bond strength on non-carious cervical lesions according to biofilm removal method)

  • 성건화;민정범;박태영
    • 대한치과의사협회지
    • /
    • 제58권11호
    • /
    • pp.683-689
    • /
    • 2020
  • Dentin surface of non-carious lesion is usually attached with oral biofilm. The biofilm should be removed before application of restorative material, because it may reduce the bond strength of adhesive system. The aim of this study was to evaluate the microtensile bond strength, when the biofilm was removed with brush or bur. Twenty extracted human third molars were sectioned horizontally to obtain dentin surface. Specimen were divided randomly into four group. Biofilm formation was performed in three group, except for Group 1 (negative control). Biofilm was removed as follows: Group 3, using ICB brush; Group 4, using lowspeed round bur #2. Group 2 (positive control) was not removed Biofilm. And in all four groups, the adhesive system (Optibond FL, Kerr) was applied to etched dentin surface, and resin composite was built up in three 1mm increments. After 24 hour storage in distilled water, the teeth were perpendicularly sectioned to obtain beams (1 × 1 mm2). Microtensile bond strength was measured and the data were statistically analyzed using one-way ANOVA and Tukey's post hoc test (p<0.05). Group 4 showed the highest microtensile bond strength (p<0.05), Group 3 showed no significant improvements when compared to Group 1. Group 2 showed lowest microtensile bond strength (p<0.05). When restoring a non-carious cervical lesion, it is essential to remove the biofilm present on the dentin surface. In addition, in the method of removing the biofilm, both the brush removal method and the bur removal method were effective.

  • PDF

임시접착 후, 치면세마에 따른 Lithium Disilicate Glass-Ceramic의 레진결합강도에 대한 연구 (Resin Bond Strength of Lithium Disilicate Glass-Ceramic by Surface Cleansing Method after Temporary Cementation)

  • 정승화;이진한;오상천
    • 구강회복응용과학지
    • /
    • 제23권3호
    • /
    • pp.259-268
    • /
    • 2007
  • purpose: This study was to evaluate the shear bond strength of Lithium Disilicate Glass-Ceramic by removable method of temporary cement on the abutment tooth. Material and Method: Sixty molar teeth of human with the occlusal surface up were mounted in acrylic resin blocks. The 45 specimens were prepared to exposure dentin by diamond bur and the eugenol-containing temporary cement($Cavitec^{TM}$ ($KERR^{(R)}$, U.S.A)was applied to the dentin surfaces. After initial removal of the cement with a dental explorer, the specimens were divided into 4 groups of 15 specimens each. The dentin surfaces of the specimens were treated by rotary instrument with as follow pastes: $Zircate^{(R)}$ prophy paste(Dentsply, U.S.A), Radent Prophy Paste(Pascal company,inc. U.S.A), and Dental pumice(Wip mix corporation,U.S.A). An adhesive resin luting agent(Variolink $II^{(R)}$, Ivoclar Vivadent, Leichtenstein) including Monobond-S and $Excite^{(R)}$ was applied to all specimens. The ceramic specimens were made with an A1 ingot of IPS Empress $II^{(R)}$ (Ivoclar Vivadent, Leichtenstein). After the specimens were stored in distilled water for 48hr, the shear bond strength(MPa) was measured by a Universal testing machine(Zwick 145641, Zwick, Germany) at a 1mm/min cross-head speed. The data were statistically analyzed by one-way ANOVA and Duncan's multiple range test. Results: In all group, there were no significant differences in comparison with the control group(p>0.05). The pattern of most failure showed the mixed type of cohesive and adhesive failure. Conclusion: Resin bond strength of IPS Empress $II^{(R)}$ was not affected by removal method of the temporary cement.

수종의 One-bottle 상아질 결합제의 전단 결합 강도에 관한 연구 (THE STUDY ON SHEAR BOND STRENGTHS OF VARIOUS ONE-BOTTLE DENTIN ADHESIVES)

  • 오소희;김종수;권순원
    • 대한소아치과학회지
    • /
    • 제28권4호
    • /
    • pp.553-565
    • /
    • 2001
  • 새로운 상아질 결합제인 5세대 상아질 결합제는 산 부식, 전 처치, 그리고 접착의 복잡한 과정을 줄여줌으로써 시술 과정이 간단하고 시간이 단축되며 시술 도중의 오염에 대한 가능성을 줄여준다는 점에서 유용성이 부각되고 있다. One-bottle 상아질 결합제에 관한 기존의 연구들이 아세톤, 에탄올 등의 용매를 포함하는 상아질 결합제를 중심으로 이루어져 본 실험에서는 water-based 상아질 결합제를 우치(牛齒)의 상아질에 적용하여 얻어지는 상아질 결합력을 전단 결합 강도 측정과 주사 전자현미경 관찰을 통해 다음과 같은 결론을 얻었다. 1. 전단결합강도의 측정결과 II군 IV군, I군, III군의 순서로 II군에서 다소 높은 전단강도를 보였으나, 모든 군들간에는 유의 차가 없었다(p>0.05). 2. 주사 전자 현미경 소견에서 II군과 IV군에서 서로 유사한 양상의 잘 형성된 혼화층이 관찰되었으며 레진 테그의 측방 가지 또한 다수 관찰할 수 있었다.

  • PDF

상아질의 봉쇄 시기와 표면처리 방법이 미세인장 결합강도에 미치는 영향 (Influence of air abrasion and different dentin sealing techniques on microtensile bond strength to dentin)

  • 강동호;한종현;박정원;김선재
    • 대한치과보철학회지
    • /
    • 제48권1호
    • /
    • pp.8-15
    • /
    • 2010
  • 연구 목적: 본 연구에서는 자가부식 접착제를 이용한 즉시 상아질 봉쇄 (immediate dentin sealing; IDS)와 지연 상아질 봉쇄 (delayed dentin sealing; DDS)에서 상아질 접착제의 결합강도를 비교하고 즉시 상아질 봉쇄에서 접착제 표면의 오염물을 제거하기 위해 사용되는 air abrasion이 상아질에 대한 미세 인장 결합강도에 어떠한 영향을 주는지에 대해 평가하였다. 연구 재료 및 방법: 1개월 이내에 발거된 사람의 건전한 대구치 30개를 6개의 군으로 분리하였고 상아질 접착제로는 자가부식 접착제 Clearfil SE bond (Kuraray, Okayama, Japan)를 사용하였다. 군분류는 치관부를 삭제하여 상아질을 노출시킨 후 즉시 접착제를 도포하고 복합레진 Filtek Z250 (3M ESPE, St Paul, MN, USA)을 충전한 군을 대조군 (Control), 노출된 상아질에 즉시 상아질 접착제를 도포하고 2주 후 재차 접착제를 도포해 복합레진과 같이 광중합하는 즉시 상아질 봉쇄군 (IDS), 상아질 노출 후 상아질 접착을 즉시 시행하지 않고 2주 후 상아질 접착과 복합레진의 충전을 시행하는 지연 상아질 봉쇄군 (DDS)으로 분류하였다. 그후Control군에 air abrasion을 시행한 군을 C-A, IDS군에 air abrasion을 시행한 군을 IDS-A군, DDS군에 air abrasion을 시행한 군을DDS-A군으로 세분화하였다. Control군과 C-A을 제외한 모든 군은 2주간 Fermit을 이용한 임시수복기간을 두었으며 대조군과 실험군 모두 미세인장 결합강도 실험 전 24시간동안 증류수에 보관 후 미세인장 결합강도를 측정하였다. 측정된 미세인장 결합강도는 one-way ANOVA를 이용하여 비교 분석하였으며 유의차가 있는 경우 Scheffe test를 이용한 사후검증을 시행하였다. 결과: 1. 자가부식 상아질 접착제인 Clearfil SE bond를 치아 삭제 직후 상아질 접착을 시행하고 2주간 임시수복 기간을 거친 후 접착제를 재도포하고 복합레진을 수복한 군과 치아삭제 후 2주간의 임시수복기간을 거친 후 상아질 접착을 시행하고 복합레진을 수복한 군 사이에 상아질-레진 간 미세인장 결합강도는 유의한 차이가 없었다 (P>.05). 2. 자가부식 상아질 접착제인 Clearfil SE bond를 상아질 접착 시행 전 $50{\mu}m$ 크기의 aluminum oxide particle로 air abrasion 처리하는 것은 상아질-레진 간 미세인장 결합강도에 유의한 영향을 주지 않았다 (P>.05).

치수절단 후 접착레진 도포에 대한 잔존치수조직 반응에 관한 연구 (THE HISTOPATHOLOGICAL STUDY ON THE RESPONSE OF THE REMAINING PULP TISSUES TO THE ADHESIVE RESIN AFTER PULPOTOMY)

  • 임성삼;박동성;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제22권2호
    • /
    • pp.720-730
    • /
    • 1997
  • This study was performed to observe the histopathological response to the bonding resin directly applied on the remaining pulp tissues. 40 teeth from 3 adult dogs were pulpotomized with a sterile round bur and sharp excarvater. In the control group, $Ca(OH)_2$ powder was applied on the pulp tissue and the cavities were sealed with IRM cement. In the experimental group 1, Superbond C&B was applied on the remaining pulp and the cavities conditioned with 10-3 solution were filled with the mixture of the MMA liquid, PMMA powder and Catalyst. Multi-purpose adhesive was used on the remaining pulp tissue in the experimental group 2 and Z-100 was filled in the cavities. In the experimental group 3, Clearfil photobond applied and directly photo-cured on the pulp tissue, then the cavities were treated with CA agent (10% citric acid and 20% $CaCl_2$ aqueous solution) for 20 seconds, washed and applied with Clearfil photobond then filled with Protect liner. The experimental animals were sacrified at the 1st, 2nd, and 4th week. The specimens were routinely processed and stained with H-E for light microscopic observation. The results were as followed : 1. In the experimental group 1, the number and characteristics of the dentin bridge formation case was similar to those in the control group and less cases were observed in the experimental group 2 and 3 than experimental group 3. The inflammatory response in experimental group 1 was less than that in the control group at 1st week but there had been little difference at between 2nd and 4th week. 2. The number of the dentin bridge in experimental group 2 was less than that in control group and experimental group 1. The inflammatory response of the experimental group 1 was similar to that of experimental group 1 but less than that of the control group. A number of bleeding and vascular congestion were observed. The least inflammatory response was seen in the experimental group 2 among all groups. 3. In the experimental group 3, one case of the dentin bridge formation was observed and that was the same as that in the experimental group 2 but smaller than that of the control and experimental group 1. The inflammatory response of the experimental group 3 was least at the 1st week and most at the 4th week in the all group.

  • PDF

열순환이 상아질 접착제의 결합 내구성에 미치는 영향 (THE EFFECT OF THERMOCYCLING ON THE DURABILITY OF DENTIN ADHESIVE SYSTEMS)

  • 문영훈;김종률;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제32권3호
    • /
    • pp.222-235
    • /
    • 2007
  • 이 논문의 목적은 열순환이 4종 상아질 접착 시스템의 결합 내구성에 미치는 영향을 측정한 것이다. 제3대구치의 상아질층을 노출시킨 후, 무작위로 8개군으로 나눈다: 3단계 산부식 시스템 (Scotchbond Multi-Purpose Plus; SM, All Bond-2 ; AB), 2 단계 산부식 시스템 (Single Bond; SB, One Step plus, OS), 2단계 자가부식 시스템 (Clearfil SE Bond; SE, AdheSE; AD), 1 단계 자가부식 시스템 (Promp L-Pop ; PL, Xeno III; XE). 8개 군에 각 상아질 접착제를 제조사의 지시에 따라 도포하고 복합레진 (Z250)을 적층한 후, 광조사한다. $37^{\circ}C$ 증류수에서 24시간 보관한 후, 각 군마다 정해진 프로그램으로 0, 1000, 2000회 열순환한 후, 저속 diamond saw로 $1\times1mm$ 막대형 시편을 제작한다. Universal testing machine (EZ-test; Shimadzu, Japan)으로 미세인장 결합강도를 측정하였고, 유의수준 0.05 level에서 ANOVA / Duncan's test로 통계분석 하였다. 상아질측 파단면과 접착계면에 대한 주사전자현미경 관찰을 시행하였다. 이 연구의 결과는 다음과 같다; 1. 3단계 상아질 접착제의 결합강도는 열순환 전후에 통계학적으로 유의한 변화를 나타내지 않았다. 2단계 산부식형 상아질 접착제의 결합강도는 열순환 처리에 의하여 유의하게 감소되었다. 2. 2단계 자가부식형 접착제 (SE)의 결합강도가 가장 높았고, 1단계 자가부식 접착제 (PL, XE)는 실험군 중 가장 낮은 결합강도를 보였다. 3. 모든 접착제는 주로 접착성 파괴가 발생하였고, 열순환에 의하여 산부식형 접착제는 접착성 파괴가, 1단계 자가부식형 접착제에서는 혼합형 파괴가 증가하는 경향을 나타내었다. 이상의 결과로, 상아질 접착제의 접착단계/과정이 결합내구성에 영향을 미침을 알 수 있었다. 따라서 접착과정의 단순화가 반드시 접착에 효과적이라고 할 수 없다.

Temporary Cement가 상아질 접착제의 접착성능에 미치는 영향 (EFFECT OF TEMPORARY CEMENT ON TENSILE BOND STRENGTH OF DENTIN BONDING AGENT)

  • 장헌수;조규증
    • Restorative Dentistry and Endodontics
    • /
    • 제20권2호
    • /
    • pp.685-698
    • /
    • 1995
  • Temporary cement가 상아질 접착제의 접착 성능에 미치는 영향을 평가하기 위해 소의 하악 전치 100개를 사용하여 순면의 상아질을 노출 시키고 유지놀을 함유하지 않은 Nogenol 및 TempBond NE와 유지놀을 함유한 TempBond 및 산화아연 유지놀세멘트를 각각 도포하여 7일 경과 후 제거하였다. All-Bond 2 및 SuperBond C&B 상아질 접착제를 제조회사의 지시대로 사용하여 접착시킨뒤 $37^{\circ}C$ 항온조에서 24시간 보관 후 인장접착강도를 측정하고, 응집 파단율을 산정하였다. 그리고 temporary cement를 적용하지 않은 상아질면과 temporary cement를 도포하였다가 제거한 상아질면에 10% 인산 수용액 및 10% 구연산 수용액으로 각각 산처리한 상아질 표면성상과 접착실험후의 파단면을 주사전자현미경으로 관찰하여 다음의 결과를 얻었다. 1. All-Bond 2로 접착시킨 경우에 는 사용한 temporary cement의 종류에 관계없이 실험군의 인장접착강도가 temporary cement를 사용하지 않은 대조군에 비해 유의하게 낮게 나타냈으나(p<0.05), Super-Bond C&B로 접착시킨 경우에는 유의한 차이가 없었다.(p>0.05). 2. 유지놀을 함유하는 temporary cement와 유지놀을 함유하지 않는 temporary cement를 각각 적용한 실험군들의 인장접착 강도 간에는 유의한 차이가 없었다.(P>O.05). 3. 응집파단율 산정결과 All-Bond 2로 접착 시킨 경우에는 대조군에서 응집-부착성의 혼합파단양상이,실험군에서는 부착성 파단양상이 주로 나타났으나, Super-Bond C&B로 접착 시킨 경우에는 대조군과 실험군 모두에서 용접성파단양상이 우세하게 나타났다. 4. 주사전자현미경적 관찰상에서 temporary cement의 종류에 관계없이 temporary cement를 도포한후 제거하고 10% 인산 수용액 또는 10-3 용액으로 전처리한 모든 시편에서 미세한 temporary cement의 잔존물을 관찰할 수 있었다.

  • PDF

상아질-레진 계면의 공초점 현미경적 형태 및 전단결합강도와의 관계 (CONFOCAL LASER SCANNING MICROSCOPIC MORPHOLOGY OF DENTIN-RESIN INTERFACE AND ITS RELATIONSHIP WITH SHEAR BOND STRENGTH)

  • 최낙원;조병훈;손호현
    • Restorative Dentistry and Endodontics
    • /
    • 제24권2호
    • /
    • pp.310-321
    • /
    • 1999
  • In this in vitro study, confocal laser scanning microscopic morphology of dentin-resin interface and its relationship to shear bond strength were investigated after the exposed dentin surfaces were treated with 3 different kinds of dentin adhesive systems[three-step; Scotchbond Multi-Purpose Plus(SMPP), self-priming bonding resin; Single Bond(SB), self-etching primer; Clearfil Liner Bond 2(LB2)]. 52 extracted human molar teeth without caries and/or restorations. The experimental teeth were randomly divided into three groups of seventeen teeth each. In five teeth of each group, class V cavities(depth: 1.5mm) with 900 cavosurface angles were prepared at the cementoenamel junction on buccal and lingual surfaces. Bonding resins of each dentin adhesive system were mixed with rhodamine B. Primer of SMPP was mixed with fluorescein. In group 1. the exposed dentin was conditioned with etchant, applied with above primer and bonding resin of SMPP. In group 2, with etchant and self-priming bonding agent of SB. In group 3, with self-etching primer and bonding agent of LB2. After treatment with dentin adhesive systems, composite resin were applied and photocured. The experimental teeth were cut longitudinally through the center line of restoration and grounded so that about $90{\mu}m$-thick wafers of buccolingually orientated dentin were obtained. And, $70{\sim}80{\mu}m$-thick wafers sectioned horizontally, thus presenting a dentinal tubules at 900 to the cut surface of a remaining tooth, were obtained. Primer of SMPP mixed with rhodamine B was applied to these wafers. Confocal laser scanning microscopic investigations of these wafers were done within of 24 hours after treatment. To measure shear bond strength, the remaining twelve teeth of each group were grounded horizontally below the dentinoenamel junction, so that no enamel remained. After applying dentin adhesive systems on the dentin surface, composite was applied in the shape of cylinder. The cylinder was 5mm in diameter, and 2mm in thickness. Shear bond strength was measured using Instron with a cross-head speed of 0.5mm/min. It was concluded as follows ; 1. Hybrid layer of SMPP(mean: $4.56{\mu}m$) was thicker than that of any other groups. This value was not statistically significant thicker than that of SB(mean: $3.41{\mu}m$, p>0.05), and significant thicker than that of LB2(mean: $1.56{\mu}m$, p<0.05). There was a statistical difference between SB and LB2(p<0.05). 2. Although there were variations in the length of resin tag even in a sample, and in a group, most samples in SMPP and SB showed resin tags extending above $20{\mu}m$. But samples in LB2 showed resin tags of $10{\mu}m$ at best. 3. Besides primer's infiltration into demineralized peritubular dentin and dentinal tubules, fluorophore of primer was detected in the lateral branches of dentinal tubules. 4. All groups demonstrated statistically significant differences from one another(p<0.05), with shear bond strengths given in descending order as follows: SMPP(18.3MPa), SB(16.0MPa) and LB2(12.4MPa). 5. LB2 having thinnest hybrid layer($1.56{\mu}m$) showed the lowest shear bond strength(12.4MPa).

  • PDF

상아질접착제에 대한 광조사가 접착에 미치는 영향 (INFLUENCE OF LIGHT IRRADIATION OVER SELF-PRIMING ADHESIVE ON DENTIN BONDING)

  • 류현욱;김기옥;김성교
    • Restorative Dentistry and Endodontics
    • /
    • 제26권5호
    • /
    • pp.409-417
    • /
    • 2001
  • 상아질접착제의 광조사가 상아질접착에 미치는 영향을 알아보기 위하여 in vitro에서 접착실험을 하였다. 120개의 발거된 소의 전치 협면 상아질을 노출시키고 산 부식 한 다음 self-priming형 상아질접착제 Prime&Bond$^{\circledR}$NT (Dentsply DeTrey, GmbH, Konstanz, Germany)를 도포 하였으며 600 mW/$\textrm{cm}^2$의 일반광도 또는 1930 mW/$\textrm{cm}^2$의 초고광도 광조사를 각각 20초 및 3초간 시행한 군과 시행하지 않은 군으로 나누어 복합레진 첨가후 광조사하였다. 접착제에 대한 광조사를 시행하지 않은 경우에는 복합레진 첨가 후 초고광도로 3초, 6초 및 12초간 광조사하였다. 접착양상 평가를 위해 만능시험기로 전단접착강도를 측정하고 파단면을 입체 현미경으로 관찰한 바를 일원 및 이원 변량분석법과 카이제곱검사법으로 통계 분석하여 다음과 같은 결과를 얻었다. 1. 상아질접착제를 광조사한 군이 광조사하지 않은 군에 비해 유의하게 높은 전단접 착강도를 나타내었다 (p<0.05). 2. 일반 광도 및 초고광도 광조사에 따른 전단접착강도에는 유의한 차이가 나타나지 않았다 (p>0.05). 3. 상아질접착제를 광조사하지 않고 복합레진 첨가 후 초고광도로 광조사한 군간에 조사시간에 따른 전단접착강도에는 유의 한 차이가 나타나지 않았다 (p>0.05). 4. 파단면 관찰 결과, 모든 군에서 접착계면에서의 파절을 포함하는 혼합파단양상이 가장 많이 나타났으며 군간에는 유의한 차이가 없었다 (p>0.05).

  • PDF