• Title/Summary/Keyword: Airborne exposure

Search Result 263, Processing Time 0.029 seconds

Field Evaluation of Korean Passive Sampler for Organic Vapor (유기용제 측정을 위한 국산 수동식 시료채취기의 현장평가)

  • Paik, Nam Won;Yoon, Chung Sik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.124-132
    • /
    • 1998
  • The Korean-made passive samplers were evaluated at the working environment for field testing. Tested materials were n-hexane, toluene and trichloroethylene. The performance of passive samplers depended on types and concentrations of organic vapors. Sampling rates were not steady until certain concentrations. The optimum concentration for determination of airborne toluene by passive samplers was equal to or over 10 ppm which is 1/10 of the Korean occupational exposure limit. Optimum concentration of n-hexane was equal to and over 1 ppm which is 1/50 of Korean occupational exposure limit. But for trichloroehtylene, coefficient of variation was 53.5 %. Passive samplers may be used for determination of n-hexane. For other materials, further study on the performance of Korean-made passive samplers is required.

  • PDF

Inhaled Nanoparticles and Occupational Health: A Review (흡입된 나노입자와 건강: 고찰)

  • Ku, Bon-Ki
    • Journal of Environmental Health Sciences
    • /
    • v.36 no.4
    • /
    • pp.255-263
    • /
    • 2010
  • In many fields, nanotechnology is leading to the development of purposely-engineered nanoparticles and devices demonstrating new, unique and non-scalable properties. However, concern has been expressed that these same properties may present unique challenges in terms of the potential health impact. Airborne particles associated with engineered nanoparticles are of particular concern, as they can readily enter the body through inhalation. Research into the potential occupational health risks associated with inhaling engineered nanoparticles is actively being conducted in the U.S. and globally. In this article, the potential occupational health effects of inhaled nanoparticles and methods for measuring exposure to nanoparticles are discussed. Critical research needs in this field are also briefly addressed.

The Characteristics of Dispersed Asbestos Fibers Produced From Building Materials (건축재료에서 발생되는 석면입자의 특성 연구)

  • 유성환
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.191-199
    • /
    • 1993
  • This paper describes the results of a systematic study to determine the characteristics of particle generated from various types of asbestos containing material(ACM) and manmade fiber material(MMFM) during operations of cutting and grinding in laboratory and workplace. Tests were conducted with a specially designed glove box which allowed complete sampling of the generated asbestos fibers. Specificially, air measurements were made during ACM and MMFM installation in building. All personal air samples collected were identified by polarized light microscopy(PLM), X-ray diffraction(XRD) and scanning electron microscope with energy dispersive X-ray analysis(SEM/EDXA). Also, the samples were counted by phase contrast microscope(PCM) in order to compare the results with the permissible exposure standard for workplace. Results indicate that the characterisitcs of fibers found in the roofing sheet, the ceiling and the wall insulation boards were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of asbestos, while the characteristics of fibers found in the ceiling insulation board, the floor tile and the sprayed on insulation products in parking area were identical to those of rock wool. The concentrations of airborne fibers from various building materials cut by a grinder for 5 minutes were in the ranges of 0.09 $\sim$ 1.71 fibers/cc(f/cc). The highest concentration(1.71f/cc) was found during grinding the wall insulation board which also contains rock wool. The airborne fiber concentrations generated by installing at workplace were ranged from 0.0009 to 0.029 f/cc. All asbestos fibers from the ceiling insulation board at workplace were less than 20$\mu$m in length and more than 20% of them had the average aspect ratio greater than 20. Therefore, for the purpose of decreasing asbestos and man-made fiber concentrations at the workplace, the ceiling and wall board should use strong binding material to increase the binding force with fiber. Also, the permissible exposure standard for workplace(2.0f/cc) in Korea should be constituted below the maximum avaiable concentration measured at glove box.

  • PDF

A Study on the Biological Hazards Exposure for Waste Handling Industries in Korea (국내 폐기물 취급업의 생물학적 인자 노출실태)

  • Park, Hyunhee;Park, Hae Dong;Lee, Inseop
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.4
    • /
    • pp.265-275
    • /
    • 2012
  • Objectives: The aim of this study was to investigate the distribution patterns and exposure concentrations of biological hazards in waste handling industries. Methods: We selected 3 recyclable waste sorting plants(RWS), 2 food recycling plants(FR), 1 landfill area(LA) and 1 waste incineration plant(WI). Total airborne bacteria and fungi were measured with single stage impactor and gelatin filters. Endotoxin and glucan were measured with polycarbonate filters in total and respirable dust. Results: The geometric mean of airborne bacterial concentration was the highest in FR($3,273CFU/m^3$), followed by LA, RWS, and WI as 1,334, 934, and $860CFU/m^3$. The fungal concentrations were 6,031, 5,052, 3,307, and $713CFU/m^3$ in RWS, WI, FR, and LA, respectively. By process, WI pit showed the highest concentrations of bacteria, fungi, and endotoxin, followed by inside of bulldozer in LA. The indoor to outdoor ratios of bacteria, fungi, endotoxin and glucan were 2.3, 4.0, 2.3, and 5.0 in RWS, 29.5, 4.9, 7.6, and 5.0 in FR, 5.3, 8.7, 26.8, and 9.5 in WI, respectively. Conclusions: We found that biological hazards, specifically bacteria in FR, fungi in RWS and endotoxin in WI pit and bulldozer at LA, should be controlled to prevent worker's respiratory diseases.

Evaluation of Airborne Volatile Organic Compounds Concentrations During Nail Art Practicing for College Students (대학 네일아트 실습 중 발생하는 휘발성 유기화합물의 공기 중 농도 평가)

  • Park, Yunkyung;Choi, Inja;Choi, Hyeyoung;Ahn, Jaekyoung;Choi, Sangjun;Kim, Sujin;Kim, Hyunseo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.4
    • /
    • pp.452-463
    • /
    • 2019
  • Objectives: The purpose of this study is to evaluate airborne concentrations of volatile organic compounds(VOCs) during nail art practice by college students. Methods: Personal samples for students were measured using passive samplers(OVM 3500) during three kinds of practice, including polish nail, gel nail and acrylic French sculpture at two universities located in Gyeongsangbuk-do Province. We also monitored area concentrations using active samplers and real-time total VOC monitors(ppbRAE 3000). All samples were analyzed with a gas chromatography flame ionized detector. Statistical analysis for monitored data were conducted using a web-based Bayesian toolkit, EXPOSTATS(www.expostats.ca). Results: Twenty-four personal samples and ten area samples were collected and five chemicals(acetone, butyl acetate, ethyl acetate, ethyl methacrylate(EMA) and methyl methacrylate(MMA)) were detected. Acetone was detected in all personal samples and ranged from 2.58 ppm to 50.3 ppm. EMA was detected in all personal and area samples with a maximum concentration of 9.78 ppm during acrylic French sculpture. Personal exposure levels to acetone, butyl acetate and mixtures were significantly higher with high occupant density (p<0.05). Geometric mean (GM) concentrations of 3.61 ppm for EMA personal samples were significantly higher than that of area samples, 1.5 ppm (p<0.05). Since there was no local ventilation, total VOC concentration continued to increase as the practice progressed. Conclusions: In order to minimize VOCs exposure for trainees, it is necessary to introduce a local ventilation system and maintain adequate occupant density.

PM10 and CO2 Concentrations in the Seoul Subway Carriage (서울 지하철 객차 내 PM10과 CO2의 농도 변화)

  • Sohn, Hong-Ji;Ryu, Kyong-Nam;Im, Jong-Kwon;Jang, Kyung-Jo;Lee, Ki-Young
    • Journal of Environmental Health Sciences
    • /
    • v.35 no.6
    • /
    • pp.454-460
    • /
    • 2009
  • The subway is the major public transportation system in Seoul with 2.2 million people using it everyday. Indoor air pollution in the subway can be a significant part of population exposure because of the number of people using the subway, time spent in transit and potentially high exposure for certain pollutants. The Korea Ministry of Environment has established the level 2 of recommended standards of $PM_{10}$ and $CO_2$ in subway trains. The aims of this study were to determine the airborne levels of $PM_{10}$, $CO_2$ and any correlation between pollutant levels and number of passenger in a subway train. The airborne $PM_{10}$ and $CO_2$ were measured on the inside of trains on line #4 for 4 different days from October to November in 2008. Average $PM_{10}$ and $CO_2$ levels were $113{\pm}25{\mu}g/m^3$ and $1402{\pm}442$ ppm, respectively. These levels did not exceed the level 2 of recommended standards of $250{\mu}g/m^3$ for $PM_{10}$ and 3500 ppm for $CO_2$. $PM_{10}$ level was not correlated with the number of passengers, while $CO_2$ levels were positively correlated with the number of passengers. The findings suggested that $PM_{10}$ in subway trains may have sources other than those directly associated with the number of passengers.

Exposure Assessments on Biological Contaminants in Homes of Allergy Patients - Bacteria, Fungi, House Dust Mite Allergen and Endotoxin (알레르기 환자 가정에서 생물학적 유해인자에 대한 노출평가 -세균, 진균, 집먼지 진드기 알레르겐, 내독소를 대상으로)

  • Moon Kyong Whan;Byeon Sang Hoon;Choi Dal Woong;Kim Young Whan;Lee Jang Hee;Lee Eun Il
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.2 s.83
    • /
    • pp.120-126
    • /
    • 2005
  • To assess exposure of allergy patients to a biological environment, measurements were made of levels of airborne bacteria and fungi, house dust endotoxin and mite allergens in homes of 7 allergy patients and 12 healthy families. Concentrations of airborne total bacteria and the ratio of indoor and outdoor concentrations(I/O) in allergy patient's homes were high compared to non-allergy houses. But no significant differences could be shown for the concentration of spores of viable fungi and staphylococcus in indoor air between the homes of allergic patients and healthy families. The results of investigation on house dust mites, Dermatophagoids farinae were detected in all mattress samples and the levels in the allergy patient's homes were generally high, with individual measurements exceeding $2{\mu}g/g$ dust found in $30\%$ samples. In contrast with, Dermatophagoids pteronyssinus were detected in only $60\%$ samples and the concentrations were very low. The levels of endotoxin in dust samples collected from the allergy patient's home mattresses were higher than those of control houses. There was a positive correlation between the endotoxin levels and the house dust mite allergens.

A Risk Assessment of Asbestos Fiber Leaks to Environment during Asbestos Removal Activity in Buildings (건물 내 석면제거 작업과 공기 중 석면의 외부누출 위험성 평가)

  • Paik, Namwon;Lee, Soungcheoul;Byeon, Jaecheol;Lee, Donghee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.405-411
    • /
    • 2020
  • Objectives: The objectives of this study were to investigate whether airborne fibers were released to the outside air from the asbestos removal area in buildings, and to confirm the existence of asbestos fibers in samples using transmission electron microscopy(TEM). Methods: A total of 1,295 samples was collected from inside and outside 155 asbestos removal areas. To investigate the release of asbestos fibers from the removal area, samples were collected at three locations, such as an entrance to change room, an exit of negative pressure unit(NPU) and perimeter areas. Samples were also collected in the removal area prior to and after removal activity. All samples were analyzed by phase contrast microscopy(PCM) and one-tenth of the samples was analyzed using TEM to discriminate asbestos fibers. Results: During the asbestos removal activity, 27(4.1%) of 662 samples collected outside the removal area showed airborne fiber concentrations equal to or in excess of 0.01 f/cc, the permissible emission standard of the Korean Ministry of Environment. Further, 111 samples were analyzed using TEM. The distribution of asbestos fiber concentrations was log-normal. It was found that 51 of 111 samples(46%) contained asbestos fibers. Conclusions: There is a potential risk of asbestos exposure among neighbors and the public outside the asbestos removal areas. It is recommended that the asbestos removal work be conducted strictly following the specifications required by government and/or professional organizations.

Comparison of Dose Rates from Four Surveys around the Fukushima Daiichi Nuclear Power Plant for Location Factor Evaluation

  • Sanada, Yukihisa;Ishida, Mutsushi;Yoshimura, Kazuya;Mikami, Satoshi
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.4
    • /
    • pp.184-193
    • /
    • 2021
  • Background: The radionuclides released by the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident 9 years ago are still being monitored by various research teams and the Japanese government. Comparison of different surveys' results could help evaluate the exposure doses and the mechanism of radiocesium behavior in the urban environment in the area. In this study, we clarified the relationship between land use and temporal changes in the ambient dose rates (air dose rates) using big data. Materials and Methods: We set a series of 1 × 1 km2 meshes within the 80 km zone of the FDNPP to compare the different survey results. We then prepared an analysis dataset from all survey meshes to analyze the temporal change in the air dose rate. The selected meshes included data from all survey types (airborne, fixed point, backpack, and carborne) obtained through the all-time survey campaigns. Results and Discussion: The characteristics of each survey's results were then evaluated using this dataset, as they depended on the measurement object. The dataset analysis revealed that, for example, the results of the carborne survey were smaller than those of the other surveys because the field of view of the carborne survey was limited to paved roads. The location factor of different land uses was also evaluated considering the characteristics of the four survey methods. Nine years after the FDNPP accident, the location factor ranged from 0.26 to 0.49, while the half-life of the air dose rate ranged from 1.2 to 1.6. Conclusion: We found that the decreasing trend in the air dose rate of the FDNPP accident was similar to the results obtained after the Chernobyl accident. These parameters will be useful for the prediction of the future exposure dose at the post-accident.

Occupational Exposure Monitoring for Diesel Particulate Matter Using Two Sampling Methods (디젤입자 채취를 위한 방법의 비교)

  • Lee, Su Gil;Jankewicz, Ganyk;Lee, Nae Woo
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.6
    • /
    • pp.9-14
    • /
    • 2020
  • This study was to compare the sampling efficiencies for monitoring of diesel particulate matter (DPM) using two different sampling methods; In-House PVC cyclone sampling heads and commercial airborne DPM (EC) sampling heads mounted on Dorr-Oliver cyclone heads. Personal exposure levels of DPM, analysed for elemental carbon (EC) were 0.004 - 0.2 mg/m3 for the loader drivers and 0.005 - 0.34 mg/m3 for the specialised mining vehicle (SMV) drivers were similar to previous study results. The highest result (0.34 mg/m3) might be from an irregular production schedule and multiple job tasks requested. The results using the two sampling heads were not significantly different and it is thought that the In-House PVC cyclone with 37 mm quartz filter could be used in place of the commercial sampler as a preliminary screen in place of using the commercial sampler.