Exposure Assessments on Biological Contaminants in Homes of Allergy Patients - Bacteria, Fungi, House Dust Mite Allergen and Endotoxin
![]() |
Moon Kyong Whan
(Department of Environmental Health, College of Health Sciences, Korea University)
Byeon Sang Hoon (Department of Environmental Health, College of Health Sciences, Korea University) Choi Dal Woong (Department of Environmental Health, College of Health Sciences, Korea University) Kim Young Whan (Department of Environmental Health, College of Health Sciences, Korea University) Lee Jang Hee (Environmental Health Research Center, College of Health Sciences, Korea University) Lee Eun Il (Department of Preventive Medicine, College of Medicine, Korea University) |
1 | 박동욱 : 생물학적 유해인자에 의한 건강장해와 노출 평가법. 산업보건, 3월호. 4-10. 2004 |
2 | Seitz, TA : NIOSH indoor air quality investigations: Proceedings of the Indoor Air Quality International Symposium, Cincinnati, OH, National Institute for Occupational Safety and Health, 1989 |
3 | 박동욱,조경아,윤충식,한인영,박두용 : 유치원 교설 에서 공기중 박테리아와 곰팡이 발생에 영향을 미치는 요인. 한국환경보건학회지,30(5),440-448,2004 |
4 | 전숙영,염혜영,류정우,정병주,김규언,이기영 : 아토피피부염 환아에서 두피의 비듬내 집먼지 진드기 항원 농도와 임상증상 사이의 상관관계. 소아알레르기 및 호흡기학회,9,1999 |
5 | 박동욱 : 생물학적 유해인자에 의한 건강장해와 노출 평가법,산업보건,4월호,2004 |
6 | Gehring,U., Bischof,W., Besrte, M., Herbarth,O.,Wichmann,H. E. and Heinrich,J. : Levels and prerotcid of endotoxin in mattress dust samples from east and west German homes,Indoor Air,14,2004 |
7 | Roaa,M. A. : Association of asthma symptoms and severity with indoor bioaerosol. Allergy,55,705-711,2000 DOI ScienceOn |
8 | 홍천수 : 집먼지 진드기에 대한 환자의 감작상태와 환자 집먼지내 집먼지 진드기의 생태에 관한조사. 알레르기,11,1991 |
9 | 하경수,김창수,문지영,양지연,신동천,홍천수 : 실내 공기 중 bioaerosol의 분포 및 건강에 미치는 영향 평가. 한국실내환경학회 학술대회 논문집 ,236-238,2004 |
10 | McNeel, S. V. and Kreutzer, R. V. : Fungi & Indoor Air Quality. Health & Environment Digest, 10(2), 912, 1996 |
11 | 이인순, 문정순: 기관지 천식환자들의 주거환경과 집 먼지 진드기 항원량. 대한보건협회학술지,28(2), 2002 |
12 | ScienceDaily, http://www.sciencedaily.com/releases/ 2001/04/01 041 |
13 | http://blog.naver.com/hongjig/140004996133 |
14 | Lewis, FA: Regulating indoor microbes: The OSHA proposed rule on IAQ, International Conference on Fungi and Bacteria in Indoor Air Environments. 1994 |
15 | 대한 천식 및 알레르기 학회 :천식과 알레르기 질환. 군자출판사,99-106,2002 |
16 | Thad Godish: Indoor Environmental Quality, Lewis publishers, 143-164, 2001 |
17 | 이원구,조백기: 집먼지 진드기류의 생태학적 연구. 대한피부과학회잡지,1984 |
18 | 박근칠 : 진균서식에 관한 임상적 고찰. 알레르기, 4(2),1984 |
19 | Occupational Safety and Health Administration : OSHA Technical manual, section III, Chapter 2, Indoor air quality, Available from URL : http:// www.osha-slc.gov/dts/otm |
20 | 김윤신,이은규,엽무종,김기영 : 다중이용시설에서의 실내공기중 미생물분포에 관한 연구. 한국환경위생학회지,28(1),85-92,2002 |
![]() |