• Title/Summary/Keyword: Air-side

Search Result 1,200, Processing Time 1 seconds

Position Control of a Pneumatic Cylinder Actuator using PLC and Proximity Sensors (공압 실린더 액츄에이터 위치제어)

  • Kwon, Soon-Hong;Choi, Won-Sik;Chung, Sung-Won;Park, Jong-Min;Kwon, Soon-Goo;So, Jung-Duk
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.50-55
    • /
    • 2011
  • The fluid power products are widely used in current industrial area such as automation of products and equipment assembly, high-tech machine tool, aircraft, train, and etc. As the development of industry is in progress, the development of the fluid power products is demanding and it is required in every industrial area. This research proposed a pneumatic system to evaluate displacement accuracy of the pneumatic actuator without external load and to analyze capability of integration of the valve system. The pneumatic system consisted of a combination of pneumatic actuator, four two-port valves, two three-port valves, two pressure valve, a check valve, two proximity sensors, and a program logic controller (PLC). The position controller is based on the PLC connected with the proximity sensors. The maximum air pressure applied for tests was $49.05N/cm^2$ and the displacement accuracy of a stroke was measured using a dial gauge. The supply- and discharge-side of air pressure and the length of the stroke of the pneumatic cylinder were varied The test of the position control of the pneumatic cylinder was carried out 50 times at each supply- and discharge-side air pressure of 24.53/34.34, 29.43/39.24, 34.34/44.15, and $39.24/49.05N/cm^2$ and replicated three times. The accuracy of the displacement of the pneumatic cylinder stroke increased as the supply- and discharge-side of air pressure increased with the stroke length of 133mm. Also the displacement accuracy increased as the stroke length increased with the fixed supply- and discharge-side of air pressure of the pneumatic cylinder as 34.34 and $44.15N/cm^2$, respectively. The most accurate displacement of the pneumatic cylinder was obtained at the supplyand discharge-side of air pressure of 39.24 and $49.05N/cm^2$, respectively, and strokes of 170 and 190mm.

A Study of Development and Application for Side Impact Sled Test (모의 측면 충돌 시험 기법 개발 및 응용)

  • 최현진
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.138-144
    • /
    • 2004
  • Occupant protection in the side impact of a vehicle becomes one of the most important issues today. So, to reduce development time and cost, it needs test equipment which conducts an accurate simulation of the side impact crash. This paper describes a new test method for side impact, which utilizes a standard 12inch-HYGE-type sled facility. If a side impact sled test can simulate vehicle intrusion very well, it will contribute to develop full-scale side impact crash performance. The newly developed sled test method enables simulation for dummy motion, injury, door velocity, trim crack, and vehicle structure to be accurate. Ant also this sled test method can be applied to the development of side air-bag.

A Study on Indoor Environment of Interior with Ventilation

  • Kang, Tae-Wook;Koh, Jae-Yoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.267-274
    • /
    • 2006
  • There are no solar loads through windows and heat transfer from outer walls of the building to the interior This study analyzes indoor air temperature and air flow distribution for the interior of buildings or vessels occupying space. Numerical method is adopted to visualize the indoor side environmental situation. that is without heat transmission to outside the building in various cooling load conditions; supply ventilation lighting. occupancy and infiltration in conditioned spaces. Reaching time of an air conditioner is predicted theoretically by cooling load variations. Theoretical modelling of the reaching time shows good agreement with experimental results.

An Economic Analysis of the Natural Gas Air-conditioning (가스냉방의 경제성 분석)

  • Gim, Bong-Jin;Park, Yearn-Hong
    • IE interfaces
    • /
    • v.11 no.1
    • /
    • pp.207-214
    • /
    • 1998
  • Since the natural gas air-conditioning not only increases the base load of the gas company but also decreases the summer peak load of the electricity company, it is considerded as an efficient demand-side management program. This paper suggests the economic evaluation method of the gas air-conditioning program from the perspectives of the participants, the pipeline gas company, the local distribution company, the electricity company, and the total resources. The absorption type gas air-conditioning/space-heating is selected as a case study to illustrate the economic analysis of the natural gas air-conditioning.

  • PDF

A Study on the Mechanical Ventilation Design that Consider Supply and Exhaust Efficiency of the Apartment House Kitchen (공동주택 주방의 급ㆍ배기효율을 고려한 기계환기 설계에 관한 연구)

  • 함진식
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.101-108
    • /
    • 2004
  • To find more efficient exhaust effect, air curtain of upward or downward trend in gas table and left or right side of range hood were made. As result that film vapor from range hood lower part by digital camera, the air current change by moving existence and nonexistence of exhaust fan and direction of air curtain were known. Under all experiment condition, upward air curtain superior exhaust performance.

Experimental study on impeller discharge flow of a centrifugal compressor (원심 압축기 임펠러 출구 유동에 관한 실험적 연구)

  • 신유환;김광호;손병진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.483-494
    • /
    • 1998
  • This study describes the characteristics on impeller discharge flow of a centrifugal compressor with vaneless diffuser. Distorted flow at impeller exit was investigated by measuring of unsteady velocity fluctuation using hot-wire anemometer. As a result, a wake region appears near shroud side and moves to suction side and also to hub side as flow rate decreases. Jet, wake, and their boundary region which can be defined in jet-wake flow model are clearly observed at a high flow rate for the flow coefficient of 0.64, however, as flow rate decreases to the flow coefficient of 0.19, the classification of their regions disappears. Turbulence intensity also increases as flow rate decreases. Measurement error from uncertainty analysis is estimated about 4% at the flow coefficient of 0.19

  • PDF

Characteristics of NOx emission in lobed burner (로브형 버너에서의 NOx 배출특성)

  • Cho, H.C.;Cho, K.W.;Lee, Y.K.
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.140-147
    • /
    • 2000
  • Using lobed burner, flame visualization and measurements of NOx and CO concentration in the combustor exit were carried out to evaluate the relation between the lobed structure in a burner and pollutant emission characteristics. The flame stability is enhanced by the lobed burner compared to conventional circular one. The correlation on fuel discharge velocity for flame blowout should be included on a variable related to the wall effect of the burner, because the flame blowout is observed at the burner having large perimeter. The burner having lobed structure in fuel discharge side compared to conventional burner reduces by 5% NOx emission due to lower flame intensity through flame elongation. Meanwhile the burner having lobed structure in air discharge side and both fuel and air discharge side increase the NOx emission.

  • PDF

Flow and Heat Transfer Characteristics in Ice Making Heat Exchanger Applied to Ice-Storage System (빙축열 시스템의 제빙용 열교환기내에서 유동 및 열전달 특성)

  • Back, Young-Ryoul;Lee, Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.110-119
    • /
    • 1994
  • Three dimensional characteristics of fluid flow and heat transfer have been studied numerically around the latent heat storage vessel which was applied to the practical ice-storage system. The result obtained indicates that the value of frictional coefficient decreases with decrease of baffle width. For the baffle spacing. $S/H_D=9.375$, baffle height. $H/H_D=0.5$ and various pressure drop, average Nusselt numbers in heat transfer surface are much dependent on the width of side baffle and middle baffle. that is. Nu_m decreases with decrease of the width of middle baffle when the width of side baffle is 4.375, where as the optimum condition of side baffle for $Nu_m$ exists in the range of 3.5< $B_1/H_D$ <4.375 at the width of middle baffle, $B_2/H_D=6.875$.

  • PDF

Clinical Evaluation of open Thoracotomy in Spontaneous Pneumothorax (자연기흉의 개흉례에 대한 검토)

  • Kim, Jong-Won;Lee, Jong-Su
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.835-839
    • /
    • 1985
  • Spontaneous pneumothorax is the sudden collapse of a lung usually caused by air leaking from a sub-visceral pleural bleb. Response to closed thoracotomy, needle aspiration and simple observation is usually prompt and effective. But in some cases, these are unsuccessful and open thoracotomy is indicated. Author reviewed 37 cases of open thoracotomy in spontaneous pneumothorax experienced in the Dept. of Thoracic and Cardiovascular Surgery, Pusan National University Hospital, since Jan., 1980 to Dec., 1984. The results were as follows: 1. The causes of spontaneous pneumothorax: 73.0% was primary, 27.0% was secondary origin. 2. The most frequent age group of the patient: Between 11 and 30 years old. 3. All of te patient were male. 4. The side of open thoracotomy: 58.8% was right side, 8.8% was both side. 5. The most common indication of open thoracotomy; Persistent air leakage. 6. The most frequent sites of bleb or bullae: A-P segment in the L.U.L. and apical segment in the R.U.L.

  • PDF

Development of New Measurement Device for the Coefficient of Kinetic Friction by Using Side Air-Guide Track (측면 에어 가이드 트랙을 이용한 새로운 운동마찰계수 측정 장치의 개발)

  • Nam, Hyoung Joo
    • Journal of Engineering Education Research
    • /
    • v.21 no.3
    • /
    • pp.12-19
    • /
    • 2018
  • In this study, a new experimental device was developed for measurement of the coefficient of kinetic friction using a photo gate timer system which have advantages of easy and accurate detection of motion. This device, consisting of a side air-guide track and a side friction-free glider, forces a friction sample to move in a straight line without producing unnecessary friction. The new device is compared to two conventional measuring methods of friction for four different friction samples: one is using a camera system and the other is using a force sensor. It is demonstrated that the developed friction device in this study is easier to operate and produces the most accurate and the least deviating results among them. On the basis of these results, we propose that friction experiment using the new friction device is included in general physics experiment, so that engineering students should have a chance to get correct understanding of classical mechanics including friction phenomenon.