• Title/Summary/Keyword: Air-conditioning system

Search Result 3,314, Processing Time 0.032 seconds

Heat Transfer Characteristics of R-1270 using 12.7mm Inner Fin Tube (12.7mm 내면핀관을 이용한 R-1270의 열전달 특성)

  • Yoon, Jung-In;Seong, Gwang-Hoon;Shim, Gyu-Jin;Jin, Byoung-Ju;Baek, Seung-Moon;Moon, Choon-Geun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.534-541
    • /
    • 2008
  • This paper deals with the heat transfer characteristics of R-290 (Propane), R-600a (Iso-butane) and R-1270 (Propylene) as an environment friendly refrigerant and R-22 as a HCFC's refrigerant for evaporating. The experimental apparatus has been set-up as conventional vapor compression type refrigeration and air-conditioning system. The test section is a horizontal double pipe heat exchanger. Evaporating heat transfer measurements were performed for smooth tube with the outer diameters of 12.70, 9.52 and 6.35 mm and micro-fin tube 12.70 mm, respectively. For the smooth and micro-fin tubes measured in this study, the evaporating heat transfer coefficient was enhanced according to the increase of the mass flux and decrease of the tube diameter. The local evaporating heat transfer coefficients of hydrocarbon refrigerants were superior to those of R-22 and the maximum increasing rate of heat transfer coefficient was found in R-1270. The average evaporating heat transfer coefficients in hydrocarbon refrigerants showed 20 to 28% higher values than those of R-22. Also, the evaporating heat transfer coefficients of R-22 in the tube diameter of the 12.70 mm smooth and micro-fin tube were compared. Generally, the local heat transfer coefficients for both types of tubes increased with an increase of the mass flux. The heat transfer enhancement factor (EF) between smooth and micro-fin tube varied from 1.9 to 2.7 in all experimental conditions.

An experimental study on the performance improvement of dead-end type PEMFC with pulsating effect (맥동 효과를 이용한 dead-end type 연료전지의 성능향상에 대한 실험적 연구)

  • Choi, Jong-Won;Seo, Jeong-Hoon;Hwang, Yong-Sheen;Lee, Dae-Heung;Cha, Suk-Won;Kim, Min-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.567-571
    • /
    • 2008
  • PEM Fuel Cell operation mode can be classified into dead-end mode or open mode by whether the outlet port is blocked or not. Generally, dead-end type fuel cell has some merits on the pressure drop and system efficiency because it can generate more power than the open type fuel cell due to high operating pressure condition. However, the periodic purging process should be done for removing water which is formed as product of a reaction in the gas diffusion layer. In this study, cathode side dead-end type operation has been conducted. Moreover, pulsating flow generator at the outlet of cathode side has been suggested for increasing the period to purge the formed water because the pulsating flow can make formed water scattered uniformly over the whole channel. As a result, the purging period with pulsation increased by 1.5-2 times longer than that without pulsating.

  • PDF

A Study on Typical Rates of Water-use for Primary School, Middle School and High School Facilities (초.중.고등학교 시설의 급수 사용량에 대한 연구)

  • Kim, Kyu-Saeng
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.510-515
    • /
    • 2007
  • A Study on Typical Rates of Water-use for School Facilities has been carried out in this work. Water supply system is given much weight in school facilities. Therefore, it set up a basis efficiency using of water sources to calculate typical rates of water use. The results are summarized as follows ; 1) On the whole, typical rates of water-use was founded out 15 L / stu. d in pirmary school, 10 L / stu. d in middle school and 30L / stu. d in high school smaller than the existing it. It was rate of water-use change as season and Max. Rates of water-use was July. 2) I deem that school hours are 5 hour's in primary school, 7 hour's in middle school and 8 hour's in high school. It the concept of 1 hour that is lesson time 40 minutes and resting time 10 minutes in primary school, lesson time 45 minutes and resting time 10 minutes in middle school and lesson time 50 minutes and resting time 10 minutes in high school. 3) It is desired that we calculate the volume of pump and water tank throughout this concept and the size of water tank should be 1.5 times with taking pick load into consideration by this study on typical rate of water-use. 4) The amount of using water increases in gradually and I consider the life cycle of facilities is more than 10 years. As a result, I can forecast that the size will be insufficiency but I deem that if we devise a plan about parallel pumping on water tank space, we can cope with it. Also, it is expected that we can cut back the transport energy by controlling pump volume.

  • PDF

A Study on the Application of Simulation-based Simplified PMV Regression Model for Indoor Thermal Comfort Control (실내 온열환경 쾌적 제어를 위한 단순 PMV 회귀모델의 적용에 관한 시뮬레이션 연구)

  • Kim, Sang-Hun;Yun, Sung-Jun;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.69-77
    • /
    • 2015
  • The PMV regression analysis was conducted for this model based on a database of the PMV variables. PMV regression model simplification was completed through sensitivity and data analysis. The simplified PMV regression model's and Fanger PMV model was confirmed through MAE and RMSE. And the EMS in EnergyPlus was used to establish a simplified PMV regression analysis-based thermal comfort control. Also, the thermal comfort controls based on simplified PMV model and the Fanger PMV model were applied to the building model, it was confirmed that both controls met the thermal comfort range in more than 90% of cases during the air conditioning period.

A Study of Real Time Security Cooperation System Regarding Hacker's Attack (해커의 공격에 대한 실시간 보안공조시스템 연구)

  • Park, Dea-Woo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.285-288
    • /
    • 2010
  • Chinese hackers hack the e-commerce site by bypass South Korea IP to connect to the third country, finance damaging a violation incident that fake account. 7.7.DDoS attack was the case of a hacker attack that paralyzed the country's main site. In this paper, the analysis is about vulnerabilities that breaches by hackers and DDoS attacks. Hacker's attacks and attacks on the sign of correlation analysis is share the risk rating for in real time, Red, Orange, Yellow, Green. Create a blacklist of hackers and real-time attack will be studied security and air conditioning systems that attacks and defend. By studying generate forensic data and confirmed in court as evidence of accountability through IP traceback and detection about packet after Incident, contribute to the national incident response and development of forensic techniques.

  • PDF

Demand Analysis of Technology Development for Smart Village based on Community Activities (공동체 활동을 기반으로 한 스마트빌리지 기술개발 수요분석)

  • Park, So Yeon;Cho, Hyejin;Jung, Nam-Su
    • Journal of Korean Society of Rural Planning
    • /
    • v.26 no.2
    • /
    • pp.117-126
    • /
    • 2020
  • In this study, demands of smart technology development were analyzed for rural village communities. Questionnaire items were derived by grasping the current status of information and communication technology. 49 villages in 8 regions were selected and surveys and statistical analysis were conducted. The main results of the study are as follows. First, 92% of community leaders use smartphones, search for information (38%), communicate with the Internet (36%) using smartphones, use KakaoTalk (31%), and Facebook (24%). Second, in the rural and urban exchange activities, promote support information service (51%) and promote method suggestion service (48.5%) showed that the demand for services in promote field was high. It is linked to the creation of economic opportunities. Third, in the income and production activities, demand for distribution services technology (39.3%) was high in the field of production and distribution, and cold chains that help maintain freshness until food, such as meat, fish, and vegetables are delivered to consumers when agricultural products are distributed. The constant temperature control system needs to be actively introduced. Fourth, autonomy activities showed the highest demand for air conditioning and control systems (34.2%) of community building, and the lowest demand for electronic voting (9.4%) and videoconferencing (9.4%) services. Lastly, in the general activity area of the community, the demand for technology of emergency services (37.1%) and health self-diagnosis service (35.4%), which are technologies in the welfare sector, ranked first and second respectively.

Study of Hydration Reaction Characteristics of Inorganic Salts for Chemical Cold Storage and Method of Enhancement of Heat and Mass Transfer (화학축냉용 무기염들의 수화반응 및 열 및 물질전달 향상방안)

  • 김상욱;한종훈;황용준;이건홍
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.185-191
    • /
    • 1999
  • An air-conditioning system based on the chemical heat storage principle was considered. $H_2O$ was chosen as the reaction gas and the working fluid as well. Na$_2$S, CaCl$_2$, MnCl$_2$, BaCl$_2$, MgCl$_2$, Fe$_2$(SO$_4$)$_3$ and MnSO$_4$ were tested as the solid reactants by using Cahn pressure balance. Na$_2$S was superior to other salts in respect of high capability of absorption of water gas, 5 moles of $H_2O$ per unit mole of Na$_2$S, and adequate temperature of adsorption, $65^{\circ}C$ at 7torr, and of desorption, 13$0^{\circ}C$ at 76torr. Clausius-Clapeyron diagram of Na$_2$S was obtained via adsorption experiments at several vapor pressures of water gas. To enhance heat and mass transfer characteristics, usually below 1W/m K, of the reactor bed of general adsorption systems, expanded graphite block was adapted as the support of Na$_2$S salt. Expanded graphite blocks had thermal conductivity values of 20~80W/mK with respect to 100~400kg/㎥ of block bulk density. Permeability values of expanded graphite blocks were 10$^{-13}$ ~ 10$^{-14}$ $m^2$ with respect to 100~300kg/㎥ of block bulk density showing highly decreasing values of permeability, below 10$^{-l4}$$m^2$, in the range of above 150kg/㎥ of block bulk density.y.

  • PDF

A Study on the Performance of Steam Ejector by Variation of Steam Pressure (증기압력 변화에 따른 증기 이젝터의 성능에 관한 연구)

  • Jun You-Sin;Shin You-Sik;Jin Zhen Hua;Jeong Hyo-Min;Chung Han-Shik
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.761-766
    • /
    • 2006
  • This paper describes a study on the performance of steam ejector by variation of steam pressure. Water temperature is especially important for good qualify of fish in an inland aquafam. In summer season, the water temperature increases above $25^{\circ}C$, but for good quality breeding or fish is the maintenance of optimum aquafam temperature by about $20^{\circ}C$. Therefore it is needed to drop the water temperature to provide suitable conditions of fish growth. There are many kinds of cooling system, in this study using steam ejector. After cooling the water in vacuum tank with the steam ejector then circulate this water to inland aquafam. In this way to minimizes fish stress that it is caused by water temperature. The objective of research confirms the difference of the case which there is no water in the vacuum tank and has water in the vacuum tank. The purpose of this paper is to examine the effects on the performance of steam ejector by variation of steam pressure.

  • PDF

A study to detect and leaked personal information on the smartphone. (Web을 이용한 안드로이드 기기 제어 시스템 설계)

  • Kim, Wung-Jun;He, Yi-Lun;Park, Sung-Hyun;Ban, Tae-Hak;Kim, Yong-Un;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.845-847
    • /
    • 2014
  • In recent years, the mobile OS market, enlargement and, at the same time, Android has mounted various smart phones and feature air conditioning, smart TV, cleaning robot, camera, etc. that the number is being spread at a rapid pace. But a lot of devices to control the modules and applications at once, this is not a device for controlling the dissemination of applications all in one place, and in charge of the devices that allow you to manage applications are lacking. Accordingly, in this paper, use the Web Server registered in the appliance can be controlled by management, Web access, is proposing and designing the system. This is the current research is actively in progress in the field of IoT (Internet of Things) would be utilized.

  • PDF

AutoML-based Refrigerant Leakage Detection of Air-Conditioning System (머신러닝 기반 실내 냉방기의 냉매누설 검출 방법)

  • Woo, Yeoungju;Kim, Yumin;Ahn, Sohyun;Ko, Seoyeong;Nguyen, Hang Thi Phuong;Shin, Choonsung;Jeong, Hieyong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.391-392
    • /
    • 2021
  • 해마다 실내 냉방기 냉매누설 문제가 고질적으로 반복되며 소비자들의 피해도 커져가고 있다. 특히 제조사와 설치 업체가 다른 경우 냉매 누수의 원인이 제품인지, 설치하자인지 책임소재를 두고 갈등을 빚는 경우가 빈번하다. 이에 더 이상 소비자들의 피해를 막기 위해 냉매누설 검출 방안 마련이 필요해 보인다. 본 연구에서는 실내 냉방기 설치 후 냉매누설 검출을 위한 별도의 하드웨어 장치 추가 없이 냉방기의 운영을 위해 설치된 센서들의 값을 이용하여 냉매누설의 유무를 판단할 수 있는 방안을 제안하는 것을 목적으로 한다. 데이터 분석을 위하여 제조사의 제품 출하 전 현장 테스트 단계에서 측정한 온도값, 전류값, 습도값을 취합하여 데이터 셋을 구축하였다. 이때 자동화된 머신러닝(AutoML)을 이용하여 데이터의 80%를 훈련 데이터로 20%를 테스트 데이터로 사용하여 냉매량 80%는 1, 그 이하는 0으로 훈련시켰다. 구축한 데이터 셋을 이용하여 훈련시킨 결과 99% 정확도로 냉매누설 검출을 분별할 수 있었다. 또한 냉매누설과 관련성이 높은 중요 특징 4개를 추출할 수 있었다. 본 연구를 통하여 별도의 하드웨어 장치 추가 없이 소프트웨어적인 접근 방법으로 문제를 해결할 수 있는 feasibility를 확인할 수 있었다.