• Title/Summary/Keyword: Air-Distance

Search Result 1,130, Processing Time 0.026 seconds

The Calculation on the Optimum Angle of Tilt Type Window by Length of Transmitted Solar Radiation (투과일사의 유입길이에 따른 Tilt 창호의 적정 기울기 산정)

  • Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.9
    • /
    • pp.635-640
    • /
    • 2010
  • This study is suggested tilt window type to be restrained solar radiation through vertical window type in buildings. The shading and aesthetical effect of buildings would be solved by installation of tilt window type. For investigate optimum an angle of tilt window and building azimuth in reference region, the distance of transmitted solar radiation is calculated. The results of calculation showed optimum an angle of tilt window is obtained $7^{\circ}$ that the distance of transmitted solar radiation is 20% of 1.5m of balcony width. In case of an tilt window angle of $7^{\circ}$, the optimum building azimuth is showed $SW15^{\circ}{\sim}SE15$.

Filtration Efficiency of Electrically Charged Air Filters by a Corona Method

  • Murtadlo, Zainul Alim Ali;Joe, Yun-Haeng;Park, Seok-Hoon;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The influences of corona charging parameters on collection efficiency and surface potential of air filters were investigated. A polypropylene filter medium was electrically charged using a corona charger, and the resulting surface potential and filtration efficiency against neutralized KCl particles were measured. The filter media was charged under different conditions of applied voltage, voltage polarity, charging time, and distance between electrodes. In addition, we considered charging both sides of the filter as well as charging one side of the filter. As a result, electrical force obtained by charged fiber affected filtration efficiency when the apply voltage strength was higher than 7 kV. Negatively charged filter had higher filtration efficiency than positively charged filter while the surface potential of the negatively charged filter was slightly lower than those of positively charged filter. Moreover, the filtration efficiency increased as the charging time of filter fiber increased and the distance between electrodes decreased. The filtration efficiency was more sensitive to changes of charging time than to those of electrode distance, and the efficiency of both sides charged filter was higher than that of single side charged filter.

Distribution of $NO_{x}$ and CO among the Ambient air by traffic volume characteristics and distance from roadside (The Sungnam City Case) (교통량특성과 거리에 따른 대기 오염물질 분포에 관한 연구(성남시의 $NO_{x}$, Co를 중심으로))

  • 권우택;김형철
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.41-49
    • /
    • 1997
  • In South Korea since 1970s the rapid development of economic growth has brought about "Urbanization" in many areas and also raised the level of people's life in many ways. At the same time, however, the industrialization and overpopulated districts in many areas have caused the problems of air pollution in necessary. Among those air pollution, in particular, in large cities has become more serious since 1990s than before. Air pollution, like TSP and SO$_{x}$ caused by heating, generation of electric power and industrialization in 1980s, showed as that of the type of an underdeveloping country and was not hazardous enough to people in the least. Unfortunately, in 1990s NO$_{x}$, CO and O$_{3}$ caused by the soaring numbers of many types of cars have exhausted air pollutant more hazardous as the same air pollution type of many developed countries. So, the purpose of this study would be to analyze the changes of concentration of NO$_{x}$ and CO on environmental air by traffic volume and from the side drive way to the degree of distance in Sungnam City, and recognize the citizens' consciousness to air pollution and suggest the best walking point in part, and plan to design the reasonable use of cars and finally make the air quality improve toward the better-ment in part. From the research result we can know that people walking in the street would be protected from the hazardous air pollutant caused by the cats if they walk apart from a drive way as far as they can in the street. Accordingly, it might, to minimize th affect of air pollution, be thought to be desirable that the consideration of in introduction the system that the vehicle using the diesel engine motor should use the centered-lane aparted from road. Another to be desirable is that along side the road, the trees inhaled the pollution should be planted.

  • PDF

A Numerical Analysis of the Abatement of VOC with Different Photocatalytic Honeycomb Filters (광촉매 필터형상에 따른 휘발성 유기화합물의 제거에 관한 수치해석적 연구)

  • 류무성;김창녕
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-7
    • /
    • 2004
  • This study has been numerically conducted to investigate the removal efficiency of Volatile Organic Compound (VOC) for different photocatalytic honeycomb filters. Recently, the photocatalysis is being applied to air-cleaner, air-conditioner and vacuum-cleaner with the capability of air-purification, sterilization and antibiosis. However, photocatalysis is less efficient than other methods for removing VOC except in the case of low concentration. So far most of studies have focused on an improvement of the photocatalytic materials, but this study have placed emphasis on the improvements of shape of photocatalytic honeycomb filter. UV irradiation, concentration profile and pressure drop have been investigated for different cross sections of filters and for different filter lengths. Light intensity is dropped sharply with increasing distance from the UV-lamp, and becomes very low in the middle of the filters. Since photocatalytic reaction rate is a function of light intensity, VOC concentration gradient might be small in the middle of long filters. Thus, most of reaction have risen within only three times of dimensionless axial distance. These results can be used effectively for the design of advanced photocatalytic honeycomb filters.

Calibration of an $^{192}Ir$ Source Used for High Dose Rate RALS. (RALS에 장착한 Ir-192 선원의 강도측정에 대한 고찰)

  • Moon, Un-Chull
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.6 no.1
    • /
    • pp.56-60
    • /
    • 1994
  • In the past, brachytherapy was carried out mostly with radium or radon sources. Currently. use of artificially produced radionuclially produced radionuclides such as $^{137}Cs,\;^{192}Ir,\;^{198}Au,\;and\;^{125}I$ is rapidly increasing. Although electrons are often used as an alternative to interstitial implants, brachytherapy continues to remain an important mode of therapy, either alone or combined with external beam. The National Council on Radiation Protection and Measurements(NCRP) recommends that the strength of any ${\gamma}$ emitter should be specified directly in terms of exposure rate in air at a specified distance such as 1m. The air kerma strength is defined as the product of air kerma rate in 'free space' and the square of the disrance of the calibration point from the source center along the perpendicular bisector, i. e., $S_k=K_L{\times}L^2$. Where $S_K$ is the the air kerma strength and K is the air kerma rate at a specified distance L. (usually 1m). Recommended units for all kerma strength are ${\mu}Gym^{2}h^{-1}$.

  • PDF

Three-Dimensional Trajectory of a Fluid Particle in Air with Wind Effects and Air Resistance (공기 저항과 바람의 영향을 고려한 대기에서의 유체입자의 3차원 궤적)

  • 이동렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.4
    • /
    • pp.797-808
    • /
    • 2001
  • Three-dimensional trajectory of fluid particle is simulated by a particle motion, which is able to examine the influences of changes in the several parameters. To calculate the trajectory of a particle, the Runge-Kutta method was utilized. The use of a projectile of particles for the trajectory of liquid jet has been shown to be useful to estimate the influence of different operating parameters such as best particle diameter, density of liquid body, initial take-off velocity, wind velocity, cross wind velocity, take-off angle, and base angle for a released flow from the nozzle. The results give the trajectories of various types of particle of body and at different elevations, base angles, wind velocities and densities of liquid body. The trajectories in a vacuum show that air resistances decreases both the distance and the maximum height of a projectile, and also explain that the termination time is also reduced in air. In addition, the maximum distance in the x direction was obtained with take-off angles from 30 degrees to 45 degrees in still air and the projectile of particles was highly effected by wind and cross wind. Clearly, a particle has to be so positioned as to take the optimum possible advantage of the wind if the maximum distances is requested. The wind astern increased the maximum distances of x direction compared with the wind ahead. Finally, it is possible to optimize the design of pump by using these results.

  • PDF

A Study on Prediction of On-line Type Pulse Air Jet Bag Filter Effective Pulsing Distance (연속탈진형 충격기류식 여과집진장치의 여과포 유효탈진거리 예측)

  • Jeong-Sam Son;Jeong-Min Suh;Jeong-Ho Park
    • Journal of Environmental Science International
    • /
    • v.32 no.8
    • /
    • pp.555-561
    • /
    • 2023
  • A study is to predict the effective pulsing distance following to the pulsing pressure, nozzle diameter, filtration velocity using numercial analysis techniques and use it as an efficient operation condition and economic data for on-line type pulse air jet bag filter. Filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the primary experiments using coke dust. For CFD simulation, analysis pulsing characteristics about nozzle diameter, filtration velocity and pulsing pressure. The maximum pulsing length of on-line type pulse air jet bag filter, in 10mm nozzle, filtration velocity 1.5m/min and pulsing pressure 5 bar conditions, is 2,285 mm, maximum length is 76.2% of the total filter bag, which is sufficient to pulsing. In 12mm nozzle, pulsing pressure 5 bar and filtration area 1.22 m2 conditions, the maximum pulsing length of on-line type pulse air jet bag filter is 1,744~2,952 mm, and the maximum length is 2,952 mm indicates pulsing air can be reached to the bottom of filter bag. When the nozzle diameter is increased 8mm to 10mm, maximum pulsing length is extended 40~47%, and increased 10mm to 12 mm, maximum pulsing length is extended 10~17%. For effective pulsing, over the 5bar of pulsing pressure and larger than 10 mm of nozzle diameter are required.

Study of Electromagnetic Characteristics for Air discharge using Ultra - wideband Antenna (광대역 안테나를 이용한 기중방전현상에 대한 전자기적 특성에 관한 연구)

  • Lee K. W.;Yoon S. C.;Kim M. Y.;Baik K. S.
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1489-1491
    • /
    • 2004
  • PD in air is accompanied by light, sound and electromagnetic wave. Light and sound can be prevented from blocking between PD sources and sensor but electromagnetic wave can be transferred to long distance without any interference an captured by antenna. This paper investigated the wideband antenna is appropriate for sensing Partial discharge in air. PD was generated from simulated PD source which consist of needle and flat electrode with small gap. Signals obtained from wideband antenna were diminished in both time and frequence region with the distance between PD source and antenna.

  • PDF

Thermal Transport from an Aluminum Foam Heat Sink in a Confined Impinging Air Jet (국한 충돌공기제트에 의한 발포 알루미늄 방열기의 열전달 특성)

  • Hwang, Jun;Kim, Seo-Young;Kang, Byung-Ha
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.4
    • /
    • pp.496-503
    • /
    • 2003
  • An experimental study has been performed on thermal transport from an aluminum foam heat sink under a confined impinging air jet. Three kinds of aluminum foam heat sinks with 10, 20 and 40 PPI and a conventional pin-fin heat sink are tested in the present study. The jet Reynolds number is varied in the range of Re=667~5672 The effect of the confinement disk diameter and the distance between the confinement disk and the heater surface on the averaged Nusselt number is investigated in detail. The results are also compared with those of the unconfined impinging air jet. The critical distance, at which thermal performance shows a minimum compared to the unconfined jet impinging, will be described in terms of the Reynolds number and the pore density of the aluminum foam.

The distance and polarization characteristics of electromagnetic wave radiated at needle-to-plane electrodes in Air and complex dielectric (공기 및 복합유전체 갭에서의 방사전자파의 거리 및 편파특성)

  • 김충년;이현동;박광서;박원주;이광식;이동인;이동헌
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.241-245
    • /
    • 2000
  • In this paper, VHF(30~230[MHz]) electromagnetic waves radiated from partial discharge(PD) at two-type electrodes in air are measured and the peculiar patterns of their spectra are reported. Also, the polarization and distance characteristics of electromagnetic wave rediated by PD, were investigated. In case of epoxy insulator in inserted, the noise level of radiated electromagnetic waves is 0.6~6.2[dB] higher than the case in air at below 90[MHz]. The frequency spectrum distribution of radiated electromagnetic waves appears different in the whole frequency range according to the arrangement of antenna.

  • PDF