• Title/Summary/Keyword: Air quality standards

Search Result 255, Processing Time 0.022 seconds

Exploration of the Relationship between Traffic Volume and Air Quality Using Existing Monitoring Data (기존 교통량/대기질 모니터링 시스템 구축 자료를 활용한 상관성 분석)

  • Go, Jun-Ho;Choe, Yu-Jin;Lee, Se-Hui;Lee, Tae-Gyeong
    • Journal of Korean Society of Transportation
    • /
    • v.27 no.5
    • /
    • pp.29-37
    • /
    • 2009
  • As the level of the ambient air quality becomes increasingly important, transportation management strategies tend to incorporate air quality standards into their measure of effectiveness. However, previous research efforts did not pay much attention to the empirical relationships between traffic volume and air quality, potentially due to the lack of data. With this background, this study investigates the relationship using Seoul's existing traffic and air quality monitoring data collected over the period of three years, from 2005 through 2007. In particular, those paired monitoring sites with a distance of less than one kilometer apart were utilized, targeting the emissions of CO, NO, $NO_2$, and $PM_{10}$. As a result, in general the data of two monitoring systems exhibited lower correlations, $NO_2$ showing a relatively higher correlation with traffic volumes than other emissions. In addition, it was found that the degree of correlation can be higher for the data obtained over the morning time period, 6am-9am, and the day after rainy days.

Recent Advances in Titania-based Composites for Photocatalytic Degradation of Indoor Volatile Organic Compounds

  • Raza, Nadeem;Kim, Ki-Hyun;Agbe, Henry;Kailasa, Suresh Kumar;Szulejko, Jan E.;Brown, Richard J.C.
    • Asian Journal of Atmospheric Environment
    • /
    • v.11 no.4
    • /
    • pp.217-234
    • /
    • 2017
  • Indoor air pollutants can cause severe health problems, specifically in terms of toxicological impacts on human. Every day, a complex mixture of many air pollutants is emitted from various sources and subject to atmospheric processes that can create varied classes of pollutants such as carboxylic acids, aldehydes, ketones, peroxyacetyl nitrate, and hydrocarbons. To adhere to indoor air quality standards, a number of techniques such as photocatalytic oxidation of various volatile organic compounds (VOCs) have been employed. Among these techniques, titania ($TiO_2$) based photocatalytic reactions have proven to be the best benchmark standard approach in the field of environmental applications. Over the last 45 years, $TiO_2$-based photocatalytic reactions have been explored for the degradation of various pollutants. This review discusses the indoor air quality profile, types of indoor pollutants, available indoor air cleaning approaches, and performance of $TiO_2$-based catalysts. Finally, we have presented the perspectives on the progress of $TiO_2$ induced photocatalysis for the purification of indoor air.

The Characteristics of Monoterpene and Air Quality in Ambient Air at Forested Road in Jeollanam-do (전남지역 숲길의 모노테르펜류 농도와 공기질 특성)

  • Oh, Gil-Young;Seo, Yun-Gyu;Park, Gui-Hwan;Kim, Ik-San;Bae, Ju-Soon;Park, Hye-Young;Yang, Soo-In;Jeon, Jun-Min;Jeong, Man-Ho;Seo, Yun-Seob;Lee, Wan-Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.2
    • /
    • pp.195-202
    • /
    • 2012
  • Three-season field study was conducted to investigate the distribution of monoterpene(10) and air anion in ambient air at five forests. ${\alpha}$-Pinene, camphene, sabinene, ${\beta}$-pinene, myrcene, terpinolene, limonene, 1,8-cineol, linalool, and camphor were quantified in the samples collected. The highest 4-hour mean concentration of total monoterpene were ${\beta}$-pinene+myrcene as 958 pptv at Juknokwon dominated by bamboo and ${\alpha}$-pinene (524 pptv), limonene (445 pptv) at Wood Land and Suncheon Bay, respectively. The seasonal means were observed to peak during spring with their maximum at Wood Land and Seonam Temple and during summer at Juknokwon and Suncheon Bay. The 24 hour concentration mean of atmosphere standards were found with much lower values than those by law. The highest concentrations of air anion were measured $400{\sim}3,000ea{\cdot}mL^{-1}$ through the sites. There is no significant correlation between the concentration of monoterpene and air anion.

Comparison of Correlation between Total Airborne Bacteria and Particulate Matter in University Spaces (일부 학교 내 총부유세균 및 미세먼지의 상관성 비교)

  • Hyekyung Seo;Harim An
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.2
    • /
    • pp.115-124
    • /
    • 2024
  • Objectives: The aim of this study is to assess indoor air quality within and around buildings and evaluate the health risks associated with exposure to indoor air pollution. The study compares IAQ standards established by the World Health Organization with those set by South Korea's Ministry of Environment and Ministry of Education. Methods: The study utilized an Anderson Sampler and DustTrakTM II to collect samples of total airborne bacteria and PM in indoor and outdoor environments. Collected samples were analyzed using biological and biochemical methods. Statistical analysis was conducted using SPSS to examine the correlation between airborne bacteria and PM. Results: The study revealed that the concentration of total airborne bacteria in indoor air generally remained below the Ministry of Environment's standard of 800 CFU/m3, although it surpassed this threshold in certain instances. PM concentrations did not exceed the standards. Indoor fine dust concentration was higher when there were people (P<0.05). There was no difference in total floating bacterial concentrations between indoor and outdoor environments (P=0.184). Finally, there was a correlation between fine dust and airborne bacteria concentrations. Conclusion: The study evaluated the concentrations of total airborne bacteria and PM in indoor air, emphasizing the importance of managing IAQ. Further research in various environments is essential to ensure a healthy indoor environment. The findings underscore the need for ongoing research and management to enhance IAQ and create safer and healthier living environments.

A Comparative Study on Ambient Air Quality Standards for Particulate Matters (입자상 오염물질의 대기환경기준에 관한 비교연구)

  • 허정숙;남보현;김동술
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.353-354
    • /
    • 1999
  • 입자상물질에 관한 초기연구는 TSP (Total Suspended Particle)에 집중되었으나, TSP만으로는 인체에 미치는 영향이나 시정악화 같은 현상을 정확하게 설명한 수 없었다. 보건학적 관점에서, PM10과 사망률사이에 강한 상관관계가 있는 것으로 조사된 바 있으며 (Pope et al, 1995), 특히 PM10 중에서 미세입자 (PM2.5미만)는 인체에 미치는 영향이 더욱 큰 것으로 알려지고 있다 (Joel et al., 1996). 이에 따라 입자상 물질의 규제 관리는 미세입자 측면에서 강화될 필요가 있다.(중략)

  • PDF

Seasonal impact to air qualities in industrial areas of the Arabian Gulf region

  • Al-Taani, Ahmed A.;Howari, Fares M.;Nazzal, Yousef;Yousef, Ahmad
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.143-149
    • /
    • 2018
  • Air quality conditions and pollution status have been evaluated in the industrial area between Sharjah and Ajman border in UAE. Daily concentrations of $O_3$, CO, $NO_2$, $SO_2$, $PM_{2.5}$, $PM_{10}$, Total Volatile Organic Compounds (TVOC) and Total Suspended Particulate (TSP) have been monitored from Sept. 2015 to April 2016. The monthly average concentrations of $O_3$, CO, $NO_2$, $SO_2$, TVOC were within the UAE ambient air quality standards during the survey period. However, $PM_{10}$ and TSP levels exceeded the recommended limits in Sept. 2015, Oct. 2015 and March 2016. Temporal variations in air quality parameters showed highest levels in March 2016 for $PM_{2.5}$, $PM_{10}$, $NO_2$, TVOC and TSP, whereas $O_3$, $SO_2$ and CO showed relatively low values in this month. $PM_{2.5}$ levels in ambient air were above the EPA guideline of $35{\mu}g/m^3$ in all months. $PM_{2.5}$ was the critical ambient air pollutant with Index for Pollutant ($I_p$) values varying from 103-209, indicating Air Quality Index categories of unhealthy for sensitive groups (62.5%) to unhealthy (25%) to very unhealthy (12.5%). The $I_p$ average values of $PM_{2.5}$ decreased from Sept. 2015 to reach lowest value in Dec. 2015 before increasing gradually, peaking in March 2016. These results suggest the potential health risks associated with $PM_{2.5}$ is low in winter, where the prevailing meteorological conditions of lower temperatures, higher humidity, higher wind speed reduced particulate matter. The results revealed the industrial area is impacted by anthropogenic and natural sources of particulate matter.

Assessment of PM2.5 and Black Carbon Concentrations among Street Vendors: Focusing on Cooking Stalls (거리 가판대에서의 초미세먼지(PM2.5)와 블랙 카본(BC)의 농도평가: 조리 가판대를 중심으로)

  • Minjung, Kim;Jiyun, Shin;Jiwon, Jeong;Sueun, Choi;Kiyoung, Lee
    • Journal of Environmental Health Sciences
    • /
    • v.48 no.6
    • /
    • pp.291-297
    • /
    • 2022
  • Background: PM2.5 and black carbon (BC) can be generated from cooking and from vehicle operation. Street vendors may be exposed to PM2.5 and BC due to their proximity both to roads and to cooking activities. Objectives: The objectives of this study were to evaluate the PM2.5 and BC concentrations in cooking stalls and to determine the effects of cooking activity and of types of cooking. Methods: Indoor and outdoor PM2.5 and BC concentrations, temperature, and relative humidity were measured in 32 stalls in April and May 2022. Behavioral factors such as the presence of cooking activity and types of cooking were observed. Student's T-test was performed using the difference of indoor and outdoor PM2.5 and BC concentrations to compare the effects of cooking activity and to compare types of cooking. Results: One-hour averages of the difference in indoor and outdoor PM2.5 concentrations for cooking stalls and non-cooking stalls were 9.7±15.7 ㎍/m3 (n=22) and -0.5±0.4 ㎍/m3 (n=10), respectively. The difference in indoor and outdoor PM2.5 concentrations in cooking stalls was significantly higher than in non-cooking stalls (p<0.05). The indoor PM2.5 concentration for stalls for Chinese pancakes and teokbokki exceeded the standards for indoor air quality in South Korea (50 ㎍/m3 ). The indoor PM2.5 concentration for Korean pancake stalls exceeded the standards for outdoor air quality in South Korea (35 ㎍/m3 for 24 hours). Conclusions: The PM2.5 concentrations in stalls with cooking activity was significantly higher than those in stalls without cooking activity. Some stalls with certain types of foods exceeded standards for indoor and outdoor air quality in South Korea. Better management of indoor air quality in stalls with cooking activities is necessary.

System design of an air-cooled 3-stage reciprocating air compressor and performance testing (공랭식 3단 왕복동 공기압축기의 시스템 설계 및 성능시험)

  • Lee, An-Seong;Kim, Yeong-Cheol;Jeong, Yeong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1380-1391
    • /
    • 1997
  • A 150 m$^{3}$/hr, 30 kg/cm$^{2}$, air-cooled 3-stage reciprocating air compressor is designed to be used in starting large diesel engines. A basic design procedure is presented to meet the targeted pressure and flow rate, and especially the volumetric efficiency. Temperature and stress analyses of the cylinder are performed using FEM modelings. The dynamics of valve system is analyzed and stress at the valve seat due to valve impact is evaluated. To reduce friction loss and wear at the compressor engine system, tribological design practices are suggested. Fin-type coolers are designed to dissipate generated compression heat at each stage. Finally, a prototype is manufactured and performance test is carried out utilizing an air tank. Performance results are compared to the design targets, other foreign specifications, and some quality standards.

Design of a Guide Vane for Improving Inside Flow Uniformity of Electrostatic Precipitator (전기집진기 내부의 유동 균일성 향상을 위한 가이드 배인의 최적설계)

  • Noh, Kyung-Wook;Bae, Seong-Jun;Park, Sookhee;Kang, Sunkyun;Lee, Jangmyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.523-528
    • /
    • 2013
  • In recent years, many efforts are increasingly being made to conserve the natural environment with enhanced emission standards and air quality standards. Also there are various methods necessary to be researched to minimize the emission of air pollutants. In particular, boilers of industrial facilities are major portions of the air pollution. The front duct which needs to be designed to reduce the gases to the electrostatic precipitator requires a bent tube, a reduction/extend tube and an auxiliary equipment, that is, a guide vane. This paper proposes an optimum design of the guide vane by a case study for electrostatic precipitator's flow uniformity. The operating conditions of this study are as follows: BMCR (Boiler Maximum Continuous Rate) and MGR (Maximum Guaranteed Rate) are 75%, 50%, and 30%; turbulent fluid dynamics model is based upon K-${\varepsilon}$ formulation. Presentation of the computed motion of particles is found to be quite useful to predict the precipitator performance by use CFD (Computational Fluid Dynamics).

Study on the Assessment of Air Quality Before and After Action Plan of Atmospheric Environment Improvement Establish at Gimhae, Gyeongnam Province (경남 김해지역의 대기환경개선 실천계획 수립 전후의 대기질 평가에 관한 연구)

  • Park, Jong-Kil;Jung, Woo-Sik;Kim, Seok-Cheol;Kim, Eun-Byul
    • Journal of Environmental Science International
    • /
    • v.17 no.10
    • /
    • pp.1111-1120
    • /
    • 2008
  • In order to study the degree of improved air quality as an outcome of the action plan of Atmospheric Environment Improvement in Gimhae, Gyeongnam Province, we investigated the status and trends of air pollutant before and after the plan. Nitrogen dioxide and ozone, both classified as hazardous substances, were closely monitored with particular attention. The level of sulfur dioxide, nitrogen dioxide, fine particles and ozone (but for carbon monoxide) was decreased after the plan was implemented. The number of days on which ozone exceeded the National Ambient Air Quality Standard has decreased, but the level was still often exceeded. The level of nitrogen dioxide did not surpass until the 2006 standard, but when the revised 2007 standard was implemented, it exceeded 80% of some standards. The yearly level of ozone has decreased since the plan was introduced. The concentration of nitrogen dioxide, however, has reduced in high order area while increased in low order area.