• 제목/요약/키워드: Air quality monitoring stations

검색결과 92건 처리시간 0.028초

서울지역 지하철역의 공기 중 오염인자의 노선별 분포 특성 (Distribution Characteristics between Line and Line for Indoor Air Pollutant Factors at Subway Stations in Seoul Area)

  • 김민영;라승훈;신도철;한규문;최금숙;정일현
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.134-144
    • /
    • 1998
  • A comprehensive air quality monitoring was carried out to investigate the criteria concentration of air pollutant in indoor of subway stations of Seoul City. The samples were collected twice per year (the first and the second half of the year) at each sampling point from February to September in 1997. Sampling point of subway stations was ticket office and platform. The measurement of indoor air pollutants such as sulfur dioxide(SO$_2$), nitrogen dioxide(NO$_2$), carbon monoxide(CO), carbon dioxide(CO$_2$), total suspended particulate(TSP) was performed to determine the indoor air quality. Heavy metals(Pb, Cd, Cu, Cr, As, Hg) were also measured together with those air pollutants. The annual average concentration of CO$_2$ and TSP in subway stations were relatively high while those of heavy metals were within 10% of environmental recommended standard concentration in all stations. As results of regression analysis between line and line of air factors, the concentrations of CO, CO$_2$, TSP, Pb, Cd, Cr and Cu were highly correlated, but those of $SO_2, NO_2$ and Hg were not correlated. As results of regression analysis between ticket office and platform, the concentrations of heavy metals such as Cr and Cu were highly correlated. Results of oneway analysis of variance between the first and the second half of the year air factors also indicated that CO, CO$_2$, Cd, Cu, Hg were significant($\alpha$=0.01), respectively. The average contration of total suspended particulate(TSP) in subway line No. 1 was shown high concentration(200 $\mu g/m^3\cdot$ day) level.

  • PDF

무선센서네트워크에 기반한 공기질 모니터링 연구 (Study of Air Quality Monitoring based on Wireless Sensor Network)

  • 박덕신;조영민;권순박;박은영;옥민환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1756-1760
    • /
    • 2008
  • In this study, it was suggested how to monitor the air quality with use of intelligent wireless sensor network in the subway station. When Zigbee-based ubiquitous sensor network was used, smaller budget was required in configuring the system compared to existing air-quality monitoring method and this system may easily be configured due to easy installation of communication cables. The study will be continued to supplement the network systems currently installed in subway stations and the completion of development of this system is expected to make a large contribution in improvement of indoor air quality.

  • PDF

광주광역시 대기오염측정소 주변 교통량이 대기질에 미치는 영향 (The Effect of Traffic Volume on the Air Quality at Monitoring Sites in Gwangju)

  • 이대행;안상수;송형명;박옥현;박강수;서광엽;조영관;김은선
    • 한국환경보건학회지
    • /
    • 제40권3호
    • /
    • pp.204-214
    • /
    • 2014
  • Objectives: Vehicular emissions are one of the main sources of air pollution in urban areas. Correlation analysis was conducted between air pollutants and traffic volume in order to identify causes of air pollution in Gwangju. Methods: Using traffic volumes and air quality monitoring data from 2002 to 2012 from nine stations (seven urban areas, two roadside areas), especially at three sites where traffic volumes were high, the correlation coefficients were obtained between air pollutants as PM-10 (particulate matter), $NO_2$, $SO_2$, CO and $O_3$ at the stations and traffic volumes near the air monitoring stations. Results: Due to traffic volume and distance between the station and the traffic road, concentrations of pollutants at roadside areas were higher than at urban areas, with the exception of $O_3$. The concentration of $O_3$ showed statistically significance with those of other gas materials as $NO_2$, $SO_2$, and CO in winter (p<0.001) and spring (p<0.05). During the period of October 7 to 20, 2012, excluding periods of yellow dust, smog and rainy season, the ratio of $NO/(NO+NO_2)$ showed the highest value 0.57 and 0.40 at Unam and Chipyeong of two roadside stations, followed by 0.35 at Nongseong with vehicular effects. The correlation coefficient between traffic volume and $O_3$, CO, $NO_2$ became higher when the data on mist and haze days were excluded, than when all hourly data were used in that period, at the three sites of Unam, Chipyeong, and Nongseong. Conclusions: Air quality showed a considerable effect from vehicles at roadside areas compared to in urban areas. Air pollutant diminishment strategies need to be aggressively adopted in order to protect atmospheric environment.

배출량 분포에 따른 대구시 일산화탄소 측정망 위치의 적절성 평가 (Assessment of the Locations for Carbon Monoxide Monitoring Stations in Daegu according to Emission Distribution)

  • 김효정;조완근
    • Spatial Information Research
    • /
    • 제20권2호
    • /
    • pp.25-34
    • /
    • 2012
  • 대구지역은 주위가 산으로 둘러싸인 분지형 도시이기 때문에 대기 환경 쾌적성이 타 도시 보다 낮은 편이다. 따라서 본 연구에서는 대구지역 자동대기오염측정소의 위치를 일산화탄소(CO) 배출량 분포에 기초하여 CO를 체계적으로 관리하기위한 적합한 장소에 대해 조사하였다. 이를 위하여 현재 대구지역 CO 관리정책 수립에 기초자료를 제공하는 자동대기측정소의 위치 적절성에 대하여 평가하였다. 대구시 수치지도와 환경부에서 제공하는 CAPSS(대기정책지원시스템 ; Clean Air Policy Support System) 자료를 활용하여 배출량 지도를 작성하였다. 도로, 아파트, 공장, 소각장 4가지로 구분하여 배출량을 입력한 뒤 법정동별 평균 배출량을 산출하였다. CO 배출지역을 고 배출량 지역과 저 배출량 지역 10단계로 구분하고 현재 측정소가 어느 단계에 해당하는지 조사하였다. 결과적으로, 저 배출량 지역 보다는 CO 고 배출량 지역에 해당하는 측정소가 부족한 것으로 나타났다. 특히, 1999년부터 2007년까지 공통적으로 추가 설치가 필요하다고 나온 국우동 외 6곳에 CO 측정망이 설치된다면 보다 다양한 기초 자료의 제공으로 체계적인 CO 관리가 가능할 것으로 판단된다.

부산지역의 다양한 환경적 요인의 변화에 따른 대기오염측정망 평가 (The Assessment of Air Quality Monitoring Network Considering the Change of Various Environmental Factors in Busan)

  • 유은철;박옥현
    • 한국대기환경학회지
    • /
    • 제22권4호
    • /
    • pp.405-420
    • /
    • 2006
  • This study was conducted to understand the change of spatial environmental factors including populations, air pollution source and land-use in Busan, during the period of 1995 and 2004. Firstly, the grids (5 km $\times$ 5 km) were divided using the TM coordinates of Busan and the statistical data of populations and land-use were marked on each grid during studying period. Secondly, the SO$_2$, NO$_2$ and O$_3$ concentrations of areas where air quality monitoring station was not established were estimated on the basis of these air pollutants measured at close air quality monitoring station by kriging method. In order to understand spatial change of air pollution and to investigate duplication and reduction of existing stations, semivariogram, correlation and cluster analysis were carried out. This study showed that the population increased in 2004 only on 8 grids compared to in 1995. The spatial change of SO$_2$, NO$_2$ and O$_3$ was investigated by semivariogram in Busan area. As the results of semivariogram, the spatial change of 502 become smaller and simpler, while that of NO2,03 become larger and more complex in 2004 than in 1995, According to the result of correlation and cluster analysis, the reduction of measurement item or the relocation of air quality monitoring station can be needed in the high dense grid area.

유해대기오염물질 모니터링을 위한 대도시 우선순위 측정지점 선정기법 제안 (Suggestions on the Selection Method of Priority Monitoring Sites for Hazardous Air Pollutants in Megacities)

  • 권혜옥;김성준;김용표;김상균;홍지형;최성득
    • 한국대기환경학회지
    • /
    • 제33권6호
    • /
    • pp.544-553
    • /
    • 2017
  • There is an overall guideline of the installation of air quality monitoring stations in Korea, but specified steps for the selection of monitoring sites for hazardous air pollutants(HAPs) are not provided. In this study, we proposed a systematic method for the selection of monitoring sites for HAPs using geographic information system (GIS). As a case study, the Seoul metropolitan area (Seoul, Incheon, and Gyeonggi Province) was chosen, and 15 factors including population, vehicle registration, and emission data were compiled for each grid cell ($7km{\times}7km$). The number of factors above the top 30% of individual data for each grid cell was used to select priority monitoring sites for HAPs. In addition, several background sites were added for data comparison and source identification. Three scenarios were suggested: Scenario 1 with 7 sites, Scenario 2 with 17 sites, and Scenario 3 with 30 sites. This proposal is not the final result for an intensive monitoring program, but it is an example of method development for selecting appropriate sampling sites. These results can be applied not only to HAPs monitoring in megacities but also to the national HAPs monitoring network.

해풍이 부산 지역의 대기 오염 농도에 미치는 영향 (The Influences of Sea Breeze on Air Pollution Concentration in Pusan, Korea)

  • 전병일;김유근;이화운
    • 한국환경과학회지
    • /
    • 제3권4호
    • /
    • pp.357-365
    • /
    • 1994
  • Air pollution characteristics and the influence of sea breeze on air pollution concentration were studied using the data measured at 7 air quality continuous monitoring stations in Pusan, 1993. Maximum air pollution concentration in Pusan was Gamjeondong for $SO_2$, Sinpyeongdong for TSP, Daeyeondong for $O_3, Kwangbokdong for $NO_2$, Beomcheondong for CO and all substances were under annual ambient air quality standards. Increased rate of concentration for sea breeze was 24.4% for 502, 31.5% for TSP, 8.0% fort $O_3, 26.7% for $NO_2$, 15.7% for CO. Frequencies distribution of $SO_2$, TSP, $O_3$, $NO_2$, and CO concentration for sea breeze moved toward high concentration class.

  • PDF

무선 센서네트워크를 이용한 역사에서의 대기오염 모니터링 (Air Pollution Monitoring of Subway using Wireless Sensor Network)

  • 박덕신;조영민;권순박;박은영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.989-993
    • /
    • 2007
  • It was intended in this study to seek for the measures to utilize the USN technique, which has high usability due to low price and low power consumption, in air quality monitoring. As a method, the sensors of temperature, humidity, particulate matters (PM10), and carbon dioxide ($CO_2$) were installed in the self-manufactured sensor nodes; the nodes were installed in the waiting rooms and platforms of a subway station and the measurements were collected at real time with use of a computer which micro gateway was built in. Collected data was to be processed by the statistics program installed in the computer; the collected data is to be used in managing the air quality of stations after transmission to the ventilation system of ventilation chambers.

  • PDF

지하역사의 공기질 감시 시스템 구성에 관한 연구 (A Study on Indoor Air Quality Monitoring System for Subway Stations)

  • 이병석;황선주;이준화;김규식;김조천
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.48-50
    • /
    • 2009
  • This paper presents an IAQ(Indoor Air Quality) Monitoring System using equipments for measurement of fine Particle($PM1{\sim}PM10$), $CO_2$, VOCs(Volatile Organic Compounds), temperature and humidity for IAQ monitoring of subway station which millions of people use a day. The necessity of IAQ monitoring system is getting increased for more effective subway station monitoring in line with the recent government's regulation for IAQ is reinforcing. Subway Station is an unusual case. The structure of subway station is closed and complicated. Therefore when data of equipments are transferred, transmission error can happen occasionally. To prevent transmission error, an IAQ Monitoring System is needed the appropriate position and selection of equipments or sensor module. In addition IT(Information Technology) can be utilized like "WiBro(Wireless Broadband)" and "GateWay" for facilitate movement of data and construction of IAQ monitoring system of subway station.

  • PDF