• Title/Summary/Keyword: Air environment

Search Result 10,267, Processing Time 0.042 seconds

Relation of Acid Depositions and Chlorophyll Concentration in the Pinus thunbergii Leaf (산성강하물과 해송엽 엽록소의 관련성)

  • Lee, Chong-Kyu;Kim, Jong-Kab;Hwang, Jin-Hyeong
    • Journal of agriculture & life science
    • /
    • v.45 no.2
    • /
    • pp.35-41
    • /
    • 2011
  • This study was carried out to investigate the relation of acid depositions and chlorophyll concentration in the Pinus thunbergii leaves. pH of throughfall in Pinus thunbergii forest was 4.20 at industrial sites, and 4.87 at urban sites. Total chlorophyll concentration in leaves were 0.5984 at industrial sites, and 0.6784 at urban sites. The average $SO_2$ concentration in air was 0.029ppm at industrial sites, and 0.011ppm at urban sites. Correlation between chlorophyll concentration in the Pinus thunbergii leaves and acid depositions was pH (r=-0.8769), ${NO_3}^-$ (r=0.6983), ${SO_4}^{2-}$ (r=0.8929), $SO_2$ (r=0.8738), and $NO_2$ (r=0.8523) (p<0.001). respectively. The estimation equation of chlorophyll concentration in the Pinus thunbergii leaf (Y) were given by Y=4.8979 + 0.7698pH + $0.8412{SO_4}^2$ + $0.8673SO_2$, + $0.8767NO_2$+ $0.8767{NO_3}^-$ ($r^2$=0.8873), which coefficients of determination was 0.88.

Temporal and Spatial Distribution of Ambient Sulfur Dioxide Concentration in Forest Areas, Korea (우리나라 산림지역에서의 이산화황 농도의 시.공간적 분포)

  • Seung-Woo, Lee;Lee, Choong-Hwa;Ji, Dong-Hun;Youn, Hee-Jung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.43 no.6
    • /
    • pp.1035-1039
    • /
    • 2010
  • For 65 national forest areas in 1993 to 2008, the ambient sulfur dioxide ($SO_2$) concentrations were measured monthly using passive samplers and compared to the those of urban areas in order to investigate the characteristics of temporal and spatial distribution. In the forest areas, annual average concentration of sulfur dioxide gradually decreased from the beginning year of monitoring to 1997 and then had no significant change, such as the annual trend in urban areas monitored by Ministry of Environment. For the monitoring term, average concentration of sulfur dioxide in the forest areas was 5.6ppb, which was lower than the 10.1ppb in the urban areas and the EC ecological standard level (7.6 ppb). Seasonally, both in forest areas and urban areas the monthly average concentrations were much higher in winter and spring due to much more heating fuel consumption, and lowest in summer. Regional comparison to other regions of Gyeongbuk and Gyeonggi province showed that the concentration of sulfur dioxide was the highest during year. A significant positive correlation between sulfur oxides' emissions and sulfur dioxide concentration by province was observed, reflecting that the size and proximity of sources of atmospheric sulfur oxides could be important factors in determination.

Surface Dose Evaluation According to the Environment Around the Patient after Nuclear Medicine Examination (핵의학 검사 후 환자의 주위 환경에 따른 표면 선량 평가)

  • Lee, Young-Hee;Park, Jae-Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.943-948
    • /
    • 2021
  • The purpose of this study was to investigate changes in surface dose due to increased scattering of gamma rays from patients injected with 99mTc and 18F, which are radioactive isotopes, in close contact with materials with high atomic number such as the walls of the stable room. Prepare 99mTc and 18F by injecting 20 and 10 mCi respectively into the NEMA phantom, and then measuring the surface dose for 60 minutes by positioning the phantom at a height of 1 m above the surface, at a distance of 0, 5 and 10 cm from the wall, and at the same location as the phantom facing the wall. Each experiment was repeated five times for reproducibility of the experiment and one way analysis of variability (ANOVA) was performed for significance testing and Tukey was used as a post-test. The study found that surface doses of 220.268, 287.121, 243.957, and 226.272 mGy were measured at 99mTc, respectively, in the case of empty space and in the case of 0, 5 and 10 cm, while those of 18F were measured at 637.111, 724.469, 657.107, and 640.365 mGy, respectively. In order to reduce changes in surface dose depending on the patient's location while waiting, it is necessary to keep the distance from the ground or the wall where the patient is closely adhered to, or install an air mattress, etc., to prevent the scattered lines as much as possible, considering the scattered lines due to the wall etc. in future setup of the patient waiting room and safety room, and in addition to the examination, the external skin width may be reduced.

Application and Utilization of Environmental DNA Technology for Biodiversity in Water Ecosystems (수생태계 생물다양성 연구를 위한 환경유전자(environmental DNA) 기술의 적용과 활용)

  • Kwak, Ihn-Sil;Park, Young-Seuk;Chang, Kwang-Hyeon
    • Korean Journal of Ecology and Environment
    • /
    • v.54 no.3
    • /
    • pp.151-155
    • /
    • 2021
  • The application of environmental DNA in the domestic ecosystem is also accelerating, but the processing and analysis of the produced data is limited, and doubts are raised about the reliability of the analyzed and produced biological taxa identification data, and the sample medium (target sample, water, air, sediment, Gastric contents, feces, etc.) and quantification and improvement of analysis methods are also needed. Therefore, in order to secure the reliability and accuracy of biodiversity research using the environmental DNA of the domestic ecosystem, it is a process of actively using the database accumulated through ecological taxonomy and undergoing verification procedures, and experts verifying the resolution of the data increased by gene sequence analysis. This is absolutely necessary. Environmental DNA research cannot be solved only by applying molecular biology technology, and interdisciplinary research cooperation such as ecology-taxa identification-genetics-informatics is important to secure the reliability of the produced data, and researchers dealing with various media can approach it together. It is an area in desperate need of an information sharing platform that can do this, and the speed of development will proceed rapidly, and the accumulated data is expected to grow as big data within a few years.

Smoke Control Experiment of a Very Deep Underground Station Where Platform Screens Doors are Installed - Analysis on Smoke Control Performance by Fans equipped in Tunnel (스크린도어가 설치된 대심도 지하역사의 제연 실험 - 터널 송풍기에 의한 제연의 효과 분석)

  • Park, Won-Hee;Kim, Chang-Yong;Cho, Youngmin
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.9
    • /
    • pp.721-736
    • /
    • 2019
  • In this paper, the behavior of the fire smoke due to the operation of the ventilation systems when the fire occurred in the underground station (6 basement floors) and the tunnel at the great depth was measured. Fire smoke was generated by using a smoke generator which realized heat buoyancy effect by using hot air blower. The two locations of the fire were selected on the platform and on the platform of the tunnel located outside the screen door. A ventilation mode is generally used in which smoke is exhausted through a vent hole provided in a platform when a platform fire occurs. The tests were performed by operating the exhaust through the ventilation holes of the tunnel part located at both ends of the platform. The smoke density and the wind speed/velocity were measured at various positions, and the videos were taken to analyze the movement and smoke of the smoke. In both cases for fire inside the platform and in the railway tunnel, due to the ventilation mode operation of the fan for the platform and the exhaust of the fans in the tunnel smoke were well exhausted and the smoke propagation to the area near the smoke zone was suppressed. The smoke-control mode, which is applied to both fans for the platform and fans for in the tunnel at both ends of the platform, can provide a safer evacuation environment to the passengers from the fire smoke when the platform fire or fire train stops.

The Study of Wave, Wave-Induced Current in CHUNG-UI Beach (충의휴양소 전면 해수욕장의 파랑 및 해빈류에 관한 연구)

  • Chang, Pyong-Sang;Bae, Sung-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.142-149
    • /
    • 2019
  • In this study, the past erosion history and current status in the CHUNG-UI beach of Eulwang-dong, Jung-gu, Incheon-Si, South Korea were investigated and analyzed the wave with wave-induced current to investigate the causes of coastal erosion. As a result, the significant wave height ($H_{1/3}$) was in the range of 0.07~1.57 m and the mean value was 0.21 m. The maximum wave height ($H_{max}$) was in the range of 0.02-4.76m and the mean value was 0.27m. The vertical wave height and cycles were estimated through numerical model experiments of wave transformation. The 50-year frequency design wave height ranged from 0.82m to 3.75m. As a result of the experiment of wave-induced current, wave-induced current in the CHUNG-UI beach was decreased after the installation of the Detached breakwater and the Jetty. On the other hand, when the crest elevation was increased up to 5 m, there was no significant change, but when the crest elevation was increased to 8m, strong wave-induced current occurred around the submerged breakwaters due to lowered depth of water. In addition, the main erosion of the CHUNG-UI beach is due to the intensive invasion of the wave characteristics coming from the outer sea into the white sandy beach. The deformation of the wave centered on the front of the sandy beach caused additional longshore currents flowing parallel to the sandy beach and rip currents in the transverse direction, thus confirming that the longshore sediment was moved out of the front and out of the sea. The results of this study can be used as preliminary data for the recovery of the sand and the selection of efficient erosion prevention facilities.

Emission Characteristics of Black Carbons Generated by Wood Combustion through a Stove (목재연료 사용에 따른 블랙카본의 배출특성)

  • Yi, Chi Yeong;Choi, Bong Seok;Sa, Jae Hwan;Jeon, Eui-Chan;Choi, Sang Jin;Park, Seong Kyu
    • Journal of Climate Change Research
    • /
    • v.4 no.1
    • /
    • pp.41-49
    • /
    • 2013
  • Recent findings have revealed that black carbon is one of the substantial materials affecting climate change along with greenhouse gases. Usually, black carbon is generated by incomplete combustion of biomass and deposited on snow and ice surface, resulting in increasing adsorption of radiant energy and accelerating ice melting. However, it is still questionable what the emission characteristics of black carbons from biomass combustion is. We investigated the emission characteristics of black carbon generated from a wood stove in this study. We found that the emission of black carbon was highly dependent upon combustion temperature and the amount of combustion air supplied. The emission factors were 1.01 g-BC/kg-Oak for fireplace wood burning under incomplete combustion, 0.37 g-BC/kg-Oak for fireplace wood burning under complete combustion and 0.29 g-BC/kg-Oak for small wood-stove burning.

A experimental Feasibility of Magnetic Resonance Based Monitoring Method for Underground Environment (지하 환경 감시를 위한 자기공명 기반 모니터링 방법의 타당성 연구)

  • Ryu, Dong-Woo;Lee, Ki-Song;Kim, Eun-Hee;Yum, Byung-Woo
    • Tunnel and Underground Space
    • /
    • v.28 no.6
    • /
    • pp.596-608
    • /
    • 2018
  • As urban infrastructure is aging, the possibility of accidents due to the failures or breakdowns of infrastructure increases. Especially, aging underground infrastructures like sewer pipes, waterworks, and subway have a potential to cause an urban ground sink. Urban ground sink is defined just as a local and erratic collapse occurred by underground cavity due to soil erosion or soil loss, which is separated from a sinkhole in soluble bedrock such as limestone. The conventional measurements such as differential settlement gauge, inclinometer or earth pressure gauge have a shortcoming just to provide point measurements with short coverage. Therefore, these methods are not adequate for monitoring of an erratic subsidence caused by underground cavity due to soil erosion or soil loss which occurring at unspecified time and location. Therefore, an alternative technology is required to detect a change of underground physical condition in real time. In this study, the feasibility of a novel magnetic resonance based monitoring method is investigated through laboratory tests, where the changes of path loss (S21) were measured under various testing conditions: media including air, water, and soil, resonant frequency, impedance, and distances between transmitter (TX) and receiver (RX). Theoretically, the transfer characteristic of magnetic field is known to be independent of the density of the medium. However, the results of the test showed the meaningful differences in the path loss (S21) under the different conditions of medium. And it is found that the reflection coefficient showed the more distinct differences over the testing conditions than the path loss. In particular, input reflection coefficient (S11) is more distinguishable than output reflection coefficient (S22).

Economic Efficiency of the BAT Standards in a Multi-pollutant Environment (다오염물질 상황에서의 최적가용기법 기준의 경제적 효율성에 관한 연구)

  • Han, Taek-Whan;Lim, Dongsoon
    • Journal of Environmental Impact Assessment
    • /
    • v.28 no.2
    • /
    • pp.141-151
    • /
    • 2019
  • Korea has passed the Act on the Integrated Control of Pollutant-Discharging Facilities in 2015, and the integrated environmental management under the BAT standard is underway. To summarize the nature of integrated environmental management, it is the regulation by the integration of the management of the multi-pollutant source and the technical standard of BATs. In general, in environmental economics, regulation-based on technical standards are known to be inefficient. This paper attempts to evaluate the efficiency of BAT standards from an economic point of view. A simple multi-pollutant model demonstrates that the inefficiency of the environmental tax with imperfect information in a single pollutant situation is amplified under multi-pollutant conditions. The simultaneous introduction of BAT and IPPC can be partially explained by this logic. It is also highlighted by the strengthening of BAT standards by EU, as a countermeasure to the potential deterioration of air quality caused by the change of effective environmental taxes accompanying the fuel and emission price changes.

A Comparison between Korean and English News Editorials with Focus on U.S.-North Korea Summit Based on Expressive Language (언어표현 기반의 북미 정상회담에 관한 한미 신문사설의 비교)

  • Noh, Bokyung;Ban, Hyun
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.125-130
    • /
    • 2019
  • This research is about alternative measure of main components for sprinkler system like automatic wet pipe sprinkler system, dry pipe sprinkler system, pre-action sprinkler system, vacuum sprinkler system, deluge sprinkler system, and so on. By replacing the alarm check valve, dry valve, pre-operated valve, and deluge open valve with a solenoid valve, it be can be simplifed the various processes of the manufacturing process into one process, it creates an environment in which one standardized product can be produced simultaneously on a single machine. Therefore, it could improve the price competitiveness of products, reduce the maintenance cost, and help the adaptability of new sprinkler systems in the future. There is a benefit when it comes to apply to sprinkler system. Only replace the valve which is used to control primary and secondary valve such as wet, dry, pre operated, vacuum, deluge system valve. Other components such as retarding chambers, automatic air compressors, accelerators or adjusters, supervisory panels, vacuum pumps, and manual starters can be used as they are, so they can be easily applied to existing sprinkler system. It is needed to legal and institutional study for solenoid valve applied sprinkler system to commercialize.