• Title/Summary/Keyword: Air circulation device

Search Result 30, Processing Time 0.035 seconds

Experimental study on flow distribution in manifolds by a tapered header (경사 분배관에 의한 다지관내의 유속분포에 대한 실험적 연구)

  • 윤영환;이상헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.1-10
    • /
    • 1998
  • A header is the device that makes uniform flow distribution in all branches from header of heat exchangers, pipe burner or chemical equipments. In this study, experimental tests have been performed in order to investigate the flow distribution characteristics in a straight header and tapered header which have 6 and 11 glass pipe branches. The experimental equipment consists of a water circulation system where the fluid velocity in each glass pipe is measured by Ar-ion LDV system. From the experiments and the theoretical equation, it could be recommended that tapered header should be determined so that its internal velocities inside the header become uniform according to taper of the header and number of attached branches for uniform flow distribution in energy systems.

  • PDF

Development of Complex Module Device for Odor Reduction in Sewage

  • KIM, Young-Do;JEONG, Tae-Hwan;Kim, Su-Hye;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.5 no.4
    • /
    • pp.51-56
    • /
    • 2022
  • Purpose: By applying an ultrasonic mechanical device to the liquid fertilizer storage in the pig dropping treatment plant, the initial odor of the odor source is reduced, and the air dilution drainage of the complex odor is fundamentally recognized to facilitate odor treatment on the mechanical and chemical biological treatment devices at the rear. Research design, data and methodology: The odor concentration on the site boundary was measured to confirm the state of reduction. In order to prevent the spread of odor from the collection of the pig dropping treatment plant, it was measured by installing an ultrasonic generator inside the installation wall after installing the sealing wall. Results: The average value of the March and April measurement data remained close to neutral at 8.2 after 8.6 treatment before pH treatment, decreased 97.3% from 462 mg/L before SS treatment to 10.5 mg/L after treatment, and the composite odor was reduced by 85% from 20 to 3 before treatment. It was confirmed that ammonia (NH3) was reduced by 99% from 5.8 ppm to 0.09 ppm, and general bacteria were also reduced by 99% from 3,200 CFU/mL to 57 CFU/mL Conclusion: Applying the ultrasonic air ejector hybrid system and zigzag air complex module development product to resource circulation centers or sewage treatment facilities is thought to reduce inconvenience to residents due to odors caused.

Experimental Study on Wave Attenuating Effect of a Pneumatic Breakwater by Using a Multiple Parallel Manifold (다중 병렬 분기관을 이용한 압축공기 방파제의 소파효과에 관한 실험적 연구)

  • KIM JONG-WOOK;Shin Hyun-Soo
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.257-262
    • /
    • 2004
  • A series of preliminary model tests are performed to find out the wave attenuating effect of the pneumatic breakwater of environment friendly type, which is a bubble screen generated by releasing compressed air from a submerged multiple parallel manifold Rising bubbles induce vertical current, which produces horizontal currents flowing away from the bubble-screen area in both directions. Near bottom, the corresponding currents flow toward the bubble screen, thus completing the circulation pattern. The surface current moving against the direction of wave propagation causes some attenuation of the waves. It becomes more effective as the relative depth (d/ L) increases (short-period waves in deep water). With the same air-discharge, the multiple parallel manifold can be more effective for the attenuation of longer waves through optimum arrangement of manifold number. installation depth, manifold gap, etc. The pneumatic breakwater will give a wide utilization as a device for protecting harbor facilities and as a simple, mobile breakwater.

  • PDF

On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment (수리실험을 이용한 발전소의 순환수 취수부 흡입수조의 와류저감에 관한 연구)

  • Eom, Junghyun;Lee, Du Han;Kim, Hung Soo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.815-824
    • /
    • 2022
  • Among the main facilities of the power plant, the circulating water used for cooling the power generation system is supplied through the Circulation Water Intake Basin (CWIB). The vortexes of various types generated in the Pump Sump (PS) of CWIB adversely affect the Circulation Water Pump (CWP) and pipelines. In particular, the free surface vortex accompanied by air intake brings about vibration, noise, cavitation etc. and these are the causes of degradation of CWP performance, damage to pipelines. Then power generation is interrupted by the causes. Therefore, it is necessary to investigate the hydraulic characteristics of CWIB through the hydraulic model experiment and apply an appropriate Anti Vortex Device (AVD) that can control the vortex to enable smooth operation of the power plant. In general, free surface vortex is controlled by Curtain Wall (CW) and the submerged vortex is by the anti vortex device of the curtain wall. The detailed specifications are described in the American National Standard for Pump Intake Design. In this study, the circulating water intake part of the Tripoli West 4×350 MW power plant in Libya was targeted, the actual operating conditions were applied, and the vortex reduction effect of the anti vortex device generated in the suction tank among the circulating water intake part was analyzed through a hydraulic model experiment. In addition, a floor splitter was basically applied to control the submerged vortex, and a new type of column curtain wall was additionally applied to control the vortex generated on the free surface to confirm the effect. As a result of analyzing the hydraulic characteristics by additionally applying the newly developed Column Curtain Wall (CCW) to the existing curtain wall, we have found that the vortex was controlled by forming a uniform flow. In addition, the vortex angle generated in the circulating water pump pipeline was 5° or less, which is the design standard of ANSI/HI 9.8, confirming the stability of the flow.

Growth Control System for Romaine Lettuce in Automated Plant Factories (식물공장 자동화를 위한 로메인 상추 생육 제어 시스템)

  • Min-Hye Lee;Tae-Soo Yu;Soon-Ja Lim
    • Journal of Industrial Convergence
    • /
    • v.22 no.10
    • /
    • pp.29-35
    • /
    • 2024
  • As the demand for healthy food increases, an automated system capable of precisely controlling the growth environment is essential for stable crop production. This study proposes an automated system for monitoring and controlling plant factories. It manages the growth environment using Arduino and various sensors, utilizing an efficient air circulation method to maintain stable internal temperatures. The experiment showed that the proposed system maintained a temperature deviation of ±1℃, a pH of 6.0, and an electrical conductivity of 1.6 dS/m, meeting standard performance. Additionally, leaf growth was found to be superior compared to crops grown in open-field conditions. The proposed system is expected to help reduce labor costs and improve the efficiency of cultivating high-quality crops.

Design and Analysis of Flap System with Shape Memory Alloy (형상기억합금이 적용된 플랩 시스템의 설계 및 해석)

  • ;Scott R, White;Eric Loth
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.596-599
    • /
    • 1997
  • In this study, the flow control system with shape memory alloy in jet engine inlet was suggested to adjust the shock boundary layer interact~on for supersonic flight system. It consisted of the flap with shape memory alloy, spar with steel, and fixing device with aluminum alloy. The advantages of itself are a simple configuration, a passive air circulation by using the flap deflection due to pressure difference, and no need to be required the auxiliary devices. Finite element analysis was conducted to predict the thenno-mechanical behavlor of the flap system with shape memory alloy. The user-defined subroutine UMAT was implemented with ABAQUS to accon~modate the thermo-mechanical constitutive relation of shape memory alloy.

  • PDF

Ionic Liquid-based Electrolytes for Li Metal/Air Batteries: A Review of Materials and the New 'LABOHR' Flow Cell Concept

  • Bresser, Dominic;Paillard, Elie;Passerini, Stefano
    • Journal of Electrochemical Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.37-44
    • /
    • 2014
  • The $Li-O_2$ battery has been attracting much attention recently, due to its very high theoretical capacity compared with Li-ion chemistries. Nevertheless, several studies within the last few years revealed that Li-ion derived electrolytes based on alkyl carbonate solvents, which have been commonly used in the last 27 years, are irreversibly consumed at the $O_2$ electrode. Accordingly, more stable electrolytes are required capable to operate with both the Li metal anode and the $O_2$ cathode. Thus, due to their favorable properties such as non volatility, chemical inertia, and favorable behavior toward the Li metal electrode, ionic liquid-based electrolytes have gathered increasing attention from the scientific community for its application in $Li-O_2$ batteries. However, the scale-up of Li-$O_2$ technology to real application requires solving the mass transport limitation, especially for supplying oxygen to the cathode. Hence, the 'LABOHR' project proposes the introduction of a flooded cathode configuration and the circulation of the electrolyte, which is then used as an oxygen carrier from an external $O_2$ harvesting device to the cathode for freeing the system from diffusion limitation.

Development of a Low-cost and High-efficiency Post-harvest Bulk Handling Machinery System of Onion - Performance Evaluation and Control

  • Park, Jongmin;Kim, Jongsoon;Jung, Hyunmo
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.26 no.2
    • /
    • pp.61-69
    • /
    • 2020
  • As post-harvest processes of onions are carried by a 20 kg-net package which results in high-cost and low-efficiency, especially, the insufficient drying and physical damage of onions after harvesting leads to a huge second loss in storage, we had developed a low-cost, high-efficiency post-harvest bulk handling machinery system by collecting onions on a farm using ton-bags, drying with forced air circulation, and sorting/packaging. The post-harvest bulk handling machinery system consisted of 6 devices, and this study designed an automatic feed hopper with a feeding rate control device, an inclined belt conveyor with a two-step chute, and an automatic pallet unloading device for feeding onions into the sorting/packing line. This study also analyzed the performance and control of the total system. The device had 1-ton handling capacity, but the operational condition was set to increase the capacity. The three-step filling method of pallet by the velocity control of the inclined belt conveyor was applied in the post-harvest bulk handling machinery system for the prevention of physical damage. If one worker was set to operate the total system, the time required to complete one palletized load was approximately 5 minutes and 5 seconds. The calculated daily handling capacity was approximately 94 tons, when the daily actual working time was 8 hours. When the developed system was applied to the managerial size of 2,000 ton, the processing cost per ton of the system was decreased by 19.5%, compared with the existing 20 kg-net package-based handling. The developed post-harvest bulk handling machinery system would be a good substitute for the rapid decline and aging of rural labor.

The A Study on the Non-powered Circulator to Solve the Temperature Stratification of a Convection Heating Device during Winter Using 3D Printer (3D프린터를 이용한 겨울철 대류난방기구의 온도 성층화 해결을 위한 무동력 서큘레이터 디자인에 관한 연구)

  • Kang, Hee-Ra
    • Journal of Digital Convergence
    • /
    • v.19 no.6
    • /
    • pp.285-292
    • /
    • 2021
  • Due to the recent Corona 19 outbreak, camping culture is rapidly drawing attention from many people. Convective heating devices, which many campers use during winter, have the temperature stratification problem. To solve this problem, various power circulators are being used. Several non-powered circulators are also on sale, but the direction of the circulator is designed to be at the right angle relative to the convection heating mechanism and the circulator does not properly play the role of air circulation. To solve this problem, a 3D printer is used to design a non-powered circulator in the same direction as the convection heating mechanism. Electricity is generated without power using Peltier element and ceramic paper and the circulator is produced to withstand heat using HTPLA-CF filament. This study presents a method to solve the temperature stratification problem through efficient convective circulation. In addition, the purpose of this study is to manufacture products at a lower cost by using a 3D printer.

Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition (병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구)

  • Kang In-Seak;Choi Dong-Kyu;Kim Taig-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.