• Title/Summary/Keyword: Air chamber

Search Result 1,334, Processing Time 0.031 seconds

Uncooled Metallic Thin-film Thermopile Infrared Detector (비냉각 금속 박막형 열전퇴 적외선 검지기)

  • Oh, Kwang-Sik;Cho, Hyun-Duk;Kim, Jin-Sup;Lee, Yong-Hyun;Lee, Jong-Hyun;Lee, Jung-Hee;Park, Se-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.2
    • /
    • pp.5-12
    • /
    • 2000
  • Uncooled metallic thin-film thermopile infrared detectors have been fabricated, and the figures of merit for the detectors were examined. The hot junctions of a thermopile were prepared on a $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$-membrane which acts as a thermal isolation layer, the cold junctions on the membrane supported with the silicon rim which functions as a heat sink, and Au-black was used as an infrared absorber. Infrared absorbance of Au-black, which strongly depends on the chamber pressure during Au-evaporation and its mass per area, was found to be about 90 % in the wavelength range from 3${\mu}{\textrm}{m}$ to 14${\mu}{\textrm}{m}$. Voltage responsivity, noise equivalent power, and specific detectivity of Bi-Sb thermopile infrared detector at 5 Hz-chopping frequency were about 10.5V/W, 2.3 nW/Hz$^{1/2}$, 및 $1.9\times10^{7}$ cm.Hz$^{1/2}$/w at room temperature in air, respectively.

  • PDF

A Study on Organic Solvent Measurement Using Diffusive Sampler (확산포집기를 이용한 공기 중 유기용제 포집에 관한 연구)

  • Park, Mi Jin;Yoon, Chung Sik;Paik, Nam Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.208-223
    • /
    • 1994
  • The purpose of this study was to evaluate the efficiency of diffusive(or passive) sampler in measuring airbone organic solvents. Diffusive samplers are generally simple in construction and do not require power for operation. The efficiency of the diffusive samplers has not sufficiently been investigated in Korea. Three types of samplers were studied in this study. The sampling and analytical results by passive samplers were compared with results by charcoal tube method recommended by NIOSH(National Institute for Occupational Safty and Health). The following characteristics are identified and studied as critical to the performance passive monitors; recovery, reverse diffusion, storage stability, accuracy and precision, face velocity and humidity, n-Hexane, TCE(trichloroethylene) and toluene were used as test vapors. A dynamic vapor exposure system consisting of organic vapor generator and sampling chamber for evaluating diffusive samplers are made. The results of the study are summarized as follows. 1. NIOSH recommands that the overall accuracy of a sampling method in the range of 0.5 to 2.0 times the occupational health standard should be ${\pm}25$ percent for 95 percent confidence level. Among three types of diffusive samplers, sampler A has permeation membrane and samplers Band C have diffusive areas, samplers A and B met the criterion that overall accuracy for 95% confidence level of the samplers were within ${\pm}25$ percent of the reference value. Sampler C had overall accuracy ${\pm}9.6%$ and ${\pm}11.8%$ in hexane and TCE, respectively. The concentration of toluene was overestimated in sampler C with overall accuracy of ${\pm}43.9%$. 2. The desorption efficiencies of diffusive samplers were 96-107%. 3. There was no significant sampe loss during four weeks of storage both with and without refrigeration. 4. There was no significant reverse diffusion, when the samplers were exposure to clean air for 2 hours after sampling for 2 hours at the level of 2 TLY. 5. In case of 8 hours sampling, relative differences(RD) of concentrations between charcoal tube method and diffusive method were 15-39%, 13-46%, and 4-35% for sampler A, B and C, respectively. The performance was poor in 8 hours sampling for multiple substance monitors. 6. At high velocity(100 cm/sec), samplers B and C overestimated the concentrations of organic vapors, and sampler A with permeation membrance gave better results. 7. At 80% relative humidity, samplers showed no siginificant effect. Low humidity also did not affect the diffusive samplers.

  • PDF

Response of Anchovy to Artificial Sounds (소리자극에 대한 멸치의 반응)

  • 김상한
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.57-62
    • /
    • 1978
  • When fisherman use the boat seine net to catch anchovy, a large noise (drum can, small drum and small gong) is used to scare the anchovy school along the wing nets, and into the bag net were they are caught. We want to know how much of an effect these s:mnds have on forceing the anchovy school towards the bag net. The underwater sounds of ancho\'y, drum can, small drum and small gong were analyzed in the labroatory. The behavioral responeses to the playback sounds of anchovy feeding and sounds of artificial instruments were also investigated. The feeding and artificial sounds of the samples were recorded by a tape recorder through a hydrophone in an anechoic aquarium. The sound intensity level was measured by means of a sound level meter in an anechoic chamber. The frequency and intensity of various sounds were analyzed with an analyzing system consisting of a ~-octave filter set, a high speed level recorder, an amplifier and an oscilloscope. The most successful recording was edited into a 9 to 10 second sound track and was repeated in a sequence of 9 to 10 second intervals. The sequence was then reproduced into an anechoic aquarium through the underwater speaker. The results of investigation are as follows; 1. The frequency of the feeding sound was 63~80Hz, and the pressure level produced was less than 32db. 2. The frequencies of the artificial sounds were 315~ 1,OOOHz, and the pressure levels were 88~95 db in the air. 3. When a hydrophone was placed 70cm below the surface with artificial sounds (drum can, small drum and small gong) produced 1 meter above the surface, the pressure level decreased about 30db. 4. The feeding sound was ineffective in attracting the anchovy, because of interference from ambient noise. 5. The artificial sounds had such a small effect on the anchovy's that they could not be used in ocean fisheries.

  • PDF

Determination of Quality Factors for Cylindrical Ionization Chambers in kV X-rays: Review of IAEA Dosimetry Protocol and Monte Carlo Calculations and Measurements for N23333 and N30001 Chambers (kV X-선에서 원통형전리함의 선질인자 결정에 관한 연구: IAEA 프로토클 고찰과 N23333, N30001 전리함에 대한 몬테칼로 계산 및 측정)

  • Lee Kang Kyoo;Lim Chunil;Chang Sei Kyung;Moon Sun Rock;Jeong Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.53-61
    • /
    • 2005
  • The quality factors for cylindrical ionization chambers for kV X-rays were determined by Monte Carlo calculation and measurement. In this study, the X-rays of 60-300 kV beam (lSO-4037) installed in KFDA and specified in energy spectra and beam qualities, and the chambers of PTW N23333 and N30001 were investigated. In calculations, the $R_{\mu}\;and\;R_{Q,Q_{0}}$ in IAEA dosimetry protocols were determined from the air kerma and the cavity dose obtained by theoretical and Monte Carlo calculations. It is shown that the N30001 chamber has a flat response of $\pm1.7\%$ in $110\~300kV$ region, while the response range of two chambers were shown to $\pm3\~4\%$ in $80\~250kV$ region. From this work we have discussed dosimetry protocol for the kV X-rays and we have found that the estimation of energy dependency is more important to apply dosimetry protocol for kV X-rays.

  • PDF

Effects of Light and Inoculation of Frankia and Alpova diplophloeus on the Tripartite Symbioses Development in Alnus rubra Bong. Seedlings (광도(光度)와 Frankia 질소고정균(窒素固定菌) 및 Alpova diplophloeus 외생균근균(外生菌根菌)의 접종(接種)이 루브라 오리나무 묘목내(苗木內) 삼자공생관계(三者共生關係) 발달(發達)에 미치는 영향(影響))

  • Koo, Chang-Duck;Molina, Randy;Miller, Steven
    • Journal of Korean Society of Forest Science
    • /
    • v.84 no.3
    • /
    • pp.306-318
    • /
    • 1995
  • To investigate the effect of low light intensities and the inoculation of Frankia and/or Alpova diplophloeus on the symbioses development and their host growth, red alder(Alnus rubra Bong.) seedlings were grown in an air - filtered walk - in growth chamber with either $N_2$ - fixing Frankia inoculation or N - fertilization and live or dead spore inoculation of the ectomycorrhizal fungus A. diplophloeus(Zeller & Dodge) Trappe & Smith. When they were 20 weeks old, the seedlings were grown under three levels of light intensities of 680, 320 and $220{\mu}mol/m^2/s$ PPFD(photosynthetic photon flux density) for three weeks. PPFD of 220 significantly decreased the development of A. diplophloeus mycorrhizae and nodules, the rates of $N_2$ - fixation and $CO_2$ exchange, and the growth of tile seedlings. PPFD 320 significantly decreased the $CO_2$ exchange rate only. Frankia inoculation significantly increased mycorrhiza formation and seedling growth. Alpova inoculation significantly increased seedling growth but not nodule development and $N_2$ - fixation. None of the symbionts affected $CO_2$ exchange rates. Frankia was more critical for seedling growth and mycorrhizal development than the mycorrhizal fungus for seedling growth and nodule development.

  • PDF

$\textrm{NO}_2$ Absorption and Physiological Response of Lettuce in a Semi-closed Plant Production System (부분 밀폐형 식물생산시스템에서 상추의 $\textrm{NO}_2$ 흡수 및 생육반응)

  • Jung Eek Son;Jong Seok Park
    • Journal of Bio-Environment Control
    • /
    • v.10 no.4
    • /
    • pp.207-212
    • /
    • 2001
  • The environmental characteristics, absorption rate of NO$_2$, physiological response, and quality of lettuces were examined in a semi-closed plant production system consisted of human and plant modules. Leaf lettuces were transplanted to 10-cm diameter pots at 4-to 5-leaf stage, and grown in a gas-fumigated plant module. Air containing NO$_2$was circulated 10 min-ON/ 20 min-OFF between the human and plant modules by a diaphragm. At 0.13, 0.30, and 0.45 $\mu$mol.mol$^{-1}$ NO$_2$, NO$_2$ decrements in the chamber during the 10 min were 0.040, 0.109, and 0.149 $\mu$mol.mol$^{-1}$ , respectively. The NO$_2$absorption rate of the plants was estimated to be 0.078 $\mu$mol.mol$^{-1}$ .m$^{-2}$ .min$^{-1}$ at 0.45 $\mu$mol.mol$^{-1}$ NO$_2$ was less than that of the control plant at 4th and 5th days, whereas the respiration rate was the same. The lettuce grown at 0.45 $\mu$mol.mol$^{-1}$ NO$_2$ had similar leaf length, leaf area, dry and fresh weights, and quality to that grown without NO$_2$.

  • PDF

Analysis of the commercial diving national qualification system for the introduction of a diving supervisor (잠수기능장 제도 신설을 위한 산업 잠수 국가자격체계 분석)

  • Sim, Kyoung-Bo;Cha, Joo-Hong;Kang, Sin-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.7
    • /
    • pp.655-662
    • /
    • 2016
  • This study proposes that a diving supervisor, who can perform the role of both a field manager and a supervisor, be introduced in the national qualification system. The goal was achieved by surveying the general status of the commercial diving sector, including the statistics of an underwater construction company, commercial diving equipment operation condition, diver working hours, diver supply and demand status, and underwater construction market size. The national qualification and national competency standard (NCS) systems were also analyzed to deduce the role definition and work scope of the diving supervisor. Consequently, the following proposition is made: the diving supervisor should be an "on-site manager with the highest job skill in the commercial diving field, who can perform the on-site process management as well as guide, supervise, and educate project participants and serve as an intermediary between the contractor and the workers." The responsibilities of the diving supervisor are proposed to include "diving planning and operation of the diving team," "diving with surface-supplied air and mixed-gas diving system," "chamber operation," "underwater construction," and "ship salvage." The persistent issues in commercial diving sectors, such as diver career development, management, and worker supervision, are expected to be largely resolved with the introduction of this qualification.

Injury Responses of Landscape Woody Plants to Air Pollutants - Visible Injury and Ethylene Production - (조경수목(造景樹木)의 대기오염물질(大氣汚染物質)에 대한 피해반응(被害反應)(II) - 엽피해(葉被害)와 Ethylene 발생량(發生量)을 중심으로 -)

  • Kim, Myung Hee;Lee, Soo Wook
    • Journal of Korean Society of Forest Science
    • /
    • v.82 no.4
    • /
    • pp.328-336
    • /
    • 1993
  • This study was conducted to investigate sensitivity of tree seedlings to $SO_2$. Visible injury symptoms and changes of ethylene production were investigated in tree seedlings with the fumigation of $SO_2$ in gas chamber 4 hours a day for six days. The symptoms of visible injury did not appear below 0.5ppm level of $SO_2$ exposure but a change of visible injury with the passage of time appeared at 1.5 and 2.5ppm in all seedlings. With the higher the concentration and/or the longer exposure of $SO_2$ the visible injury symptoms on leaves increased in all seedlings. The sensitivity of seedlings to $SO_2$ was the highest in Liriodendron tulipifera followed by Pinus strobus, Ginkgo biloba, Pinus densiflora and Pinus koraiensis. The amount of ethylene production was more at 1.5 and 2.5ppm of $SO_2$ exposure than at 0.5ppm and the peak time of it came faster at higher levels. The amount of ethylene production was significantly different among tree seedlings. It showed a higher at production of ethylene in Liriodendron tulipifera compared to Ginkgo biloba and the ethylene production of Pinus trees to $SO_2$ were the highest in Pinus strobus followed by Pinus densiflora and Pinus koraiensis. In needle of Pinus strobus the ethylene production increased with the increasing rate of visible injury until the injury rate of 40-50% and than decreased with the increasing rate of visible injury since the rate of 50%.

  • PDF

Experimental Investigation on the Performance of Small-Sized Dehumidification Rotor for Residential Use (가정용 소형 제습로터의 성능에 대한 실험적 연구)

  • Han, Ji-Chao;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2344-2349
    • /
    • 2015
  • In Korea, summer is hot and humid, and air-conditioners consume too much electricity due to large amount of latent heat. Simultaneous usage of dehumidifier may reduce the latent heat and save the electricity. In this study, dehumidification performance was measured in a constant temperature and humidity chamber for a small-sized dehumdification rotor made of inorganic fiber impregnated with metallic silicate. Variables were rotor speed, room temperature, regeneration temperature, room relative humidity and frontal velocity to the rotor. Results showed that there existed optimum rotor speed (1.0 rpm), and optimum regeneration temperature ($100^{\circ}C$). Above the optimum rotor speed, incomplete regeneration is responsible for reduced dehumidification. Above the optimum regeneration temperature, increased temperature difference between regeneration and dehumidification process is responsible for reduced dehumidification. The amount of dehumidification also increases with the increase of relative humidity, dehumidification temperature and flow velocity into the rotor.

Heat Exchange Performance of Improved Heat Recovery System (개량형 열회수 시스템의 열교환 성능)

  • Suh, Won-Myung;Yoon, Yong-Cheol;Kwon, Jin-Keun
    • Journal of Bio-Environment Control
    • /
    • v.12 no.3
    • /
    • pp.107-113
    • /
    • 2003
  • This study was carried out to improve the performance of pre-developed heat recovery devices attached to exhaust-gas flue connected to combustion chamber of greenhouse heating system. Four different units were compared in the aspect of heat recovery performance; A-, B-, and C-types are exactly the same with the old ones reported in previous studies. D-type newly developed in this experiment is mainly different with the old ones in its heat exchange area and tube thickness. But airflow direction(U-turn) and pipe arrangement are similar with previous three types. The results are summarized as follows; 1. System performances in the aspect of heat recovery efficiency were estimated as 42.2% for A-type, 40.6% for B-type, 54.4% for C-type, and 69.2% for D-type. 2. There was not significant improvement of heat recovering efficiency between two different airflow directions inside the heat exchange system. But considering current technical conditions, straight air flow pattern has more advantage than hair-pin How pattern (U-turn f1ow). 3. The main factors influencing on heat recovery efficiency were presumably verified to be the total area of heat exchange surface, the thickness of ail-flow pipes, and the convective heat transfer coefficient influenced by airflow velocity under the conditions of allowable pipe durability and safety. 4. Desirable blower capacity for each type of heat recovery units were significantly different to each other. Therefore, the optimum airflow capacity should be determined by considering in economic aspect of electricity required together with the optimum heat recovery performance of given heat recovery systems.