• Title/Summary/Keyword: Agreement index

Search Result 514, Processing Time 0.023 seconds

On the Use of the Linguistic Fuzzy Approaches in the Selection of Liquid Levelmeters for Nuclear Energy Facilities (원자력설비용 수위측정기 선정시 언어 모호집합론적 접근법 사용)

  • Ghyym, Seong-Ho
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.11a
    • /
    • pp.119-124
    • /
    • 1999
  • A selection methodology of liquid levelmeters, especially, level sensors in non-nuclear category, to be installed in nuclear energy facilities is developed using linguistic fuzzy approaches such as fully-linguistic and semi-linguistic methods. Depending on defuzzification techniques, the linguistic fuzzy methodology leads to either linguistic (exactly, fully-linguistic) or cardinal (i.e., semi-linguistic) evaluation. For the linguistic method, for each alternative, fuzzy preference index is converted to linguistic utility value by means of a similarity measure determining the degree of similarity between fuzzy index and linguistic ratings. For the cardinal method, the index is translated to cardinal overall utility value. According to these values, alternatives of interest are linguistically or numerically evaluated and a suitable alternative can be selected. Under given selection criteria, the suitable selections out of some liquid levelmeters for nuclear facilities are dealt with using the linguistic fuzzy methodology proposed. Then, linguistic fuzzy evaluation results are compared with qualitative result available in the literature. It is found that as to a suitable option the linguistic fuzzy selection is in agreement with the qualitative selection. Additionally, the comparative study shows that the fully-linguistic method using adequate scale system facilitates linguistic interpretation regarding evaluation results.

  • PDF

Similarity Analysis for the Dispersion of Spiraling Modes on Metallic Nanowire to a Planar Thin Metal Layer

  • Lee, Dong-Jin;Park, Se-Geun;Lee, Seung-Gol;O, Beom-Hoan
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.6
    • /
    • pp.538-542
    • /
    • 2013
  • We propose a simple model to elucidate the dispersion behavior of spiraling modes on silver nanowire by finding correspondence parameters and building a simple equivalent relationship with the planar insulator-metal-insulator geometry. The characteristics approximated for the proposed structure are compared with the results from an exact solution obtained by solving Maxwell's equation in cylindrical coordinates. The effective refractive index for our proposed equivalent model is in good agreement with that for the exact solution in the 400-2000 nm wavelength range. In particular, when the radius of the silver nanowire is 100 nm, the calculated index shows typical improvements; the average percentage error for the real part of the effective refractive index is reduced to only 5% for the $0^{th}$ order mode (11.9% in previous results) and 1.5% for the $1^{st}$ order mode (24.8% in previous results) in the 400-800 nm wavelength range. This equivalent model approach is expected to provide further insight into understanding the important behavior of nanowire waveguides.

Development of diagnosis index for tick/click and tone noise of blower motor using vibration signals (진동 신호를 이용한 블로워 모터 틱/클릭과 톤 소음의 진단 지수 개발)

  • Lee, Songjune;Cheong, Cheolung;Lee, In-Hyuk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.3
    • /
    • pp.363-369
    • /
    • 2019
  • Various studies have been conducted for the diagnosis of noise condition of complex rotary machines. In this study, diagnosis index using vibration signal is developed for the efficient and objective assessment of noise condition of a blower motor. The noise most commonly caused by the abnormal blower motor are Tick/Click noise and Tone noise. According to cause and noise characteristics, time-frequency analysis is used to diagnose Tick/Click noise, and smoothing in frequency domain is used to diagnose tone noise condition. The noise condition of the blower motors were diagnosed using the developed index and these results are compared with the diagnostic results by the experts. As a result, the agreement rate was about 95 %.

Toxoplasma antibody titers by ELISA and indirect latex agglutination test in pregnant women (ELISA 및 간접 latex 응집반응검사에 의한 임산부의 항 톡소포자충 항체가)

  • 류재숙;민득영
    • Parasites, Hosts and Diseases
    • /
    • v.34 no.4
    • /
    • pp.233-238
    • /
    • 1996
  • The seroepidemiologic studies on antral-ToxopIasma antibody titers were carried out using ELISA and indirect latex agglutination test. Among 899 sera prepared from pregnant women, 39 cases (4.3%) revealed positive reaction and 218 sera from middle school students showed 4 positive reaction (1.8%) by ELISA. By LAT (newly established by National Veterinary Research Institute, Korea), the sera of 7 pregnant women (0.8%) showed positive reaction. When 80 sera showing ≥ 1 :8 by LAT were used for comparing the results obtained from LAT and Toxotest-MT (Eikon Chemical Co., Japans, 7 cases and 8 sera were positive, respectively. All of 11 sera of proven toxoplasmosis patients showed positive reaction in both tests. Overall proportion of agreement between LAT kit and Toxotest-MT was 0.94 (K-index : 0.632, p < 0.01), and LAT was considered to be useful for the screening of toxoplasmosis.

  • PDF

Personal technique for definite repair of complete unilateral cleft lip: modified Millard technique

  • Han, Kihwan;Park, Jeongseob;Lee, Seongwon;Jeong, Woonhyeok
    • Archives of Craniofacial Surgery
    • /
    • v.19 no.1
    • /
    • pp.3-12
    • /
    • 2018
  • Background: Millard's rotation-advancement repair, which is used by many surgeons, can make a natural philtral column, but most surgeons use a modification of the rotation-advancement flap. The purpose of this article is to introduce a modification utilized by the authors and to provide detailed surgical procedure. Methods: We retrospectively reviewed 82 patients' medical records and presented surgical technique and outcomes. The main features of the authors' strategy are emphasizing horizontal length of the lip, orbicularis oris muscle duplication for improving the definition of the philtral column, overcorrection of domal portion than the non-cleft side in order to compensate for the recurrence during growth. Two judges rated two times the appearance of the patients' nose and lip using Asher-McDade aesthetic index. Intra- and interobserver reliabilities were determined using Cohen's kappa statistics. Results: All patients recovered eventually after surgery; however, two patients have a minor complications (wound infection in one patient, wound disruption due to trauma in the other patient). The improvement of the aesthetic results can be achieved with this modified Millard technique. Total mean scores of the Asher-McDade index was 2.08, fair to good appearance. The intraobserver reliabilities were substantial to almost perfect agreement and the interobserver reliabilities were moderate to almost perfect agreement. Conclusion: We modified Millard method for repair of complete unilateral cleft lip. The surgical outcomes were favorable in long-term follow-up. We hope our technique will serve as a guide for those new to the procedure.

Does Omission of Pharmacy Cost Affect Cost-Efficiency Rankings in Medical Clinics? (약제비 제외가 의원의 진료비 효율성 순위에 영향을 미치는가?)

  • Kang, Hee-Chung;Hong, Jae-Seok
    • Health Policy and Management
    • /
    • v.20 no.4
    • /
    • pp.45-57
    • /
    • 2010
  • Background : If different cost efficiency indexes were informed to the same clinic depending on the inclusion or exclusion of pharmacy cost, it may impair the reliability of provider-profiling system. This study aimed to investigate whether the omission of pharmacy cost affects cost-efficiency rankings in medical clinics. Methods : Data for ambulatory care cost at 23,112 medical clinics were collected from the claims database, which was constructed after review by the Health Insurance Review and Assessment Service (HIRA) of Korea in April 2007. We calculated two types of cost efficiency indexes by inclusion or exclusion of pharmacy cost for a medical clinic. The agreement between the decile rankings of the two indexes was also assessed using the weighted kappa statistic of Landis and Koch. Results : When the cost efficiency index for total cost including pharmacy cost was compared with the index for total cost excluding it, the agreement between the two indexes was only 55%. The agreements between the two indexes were relatively low within specialties which have larger pharmacy volume of total cost and lower correlation between total cost with or without pharmacy cost included than the average level of all the specialties. Conclusion : These results suggest that the omission of pharmacy cost may result in contradictory outcomes that may be confusing to a medical institution and may impair the reliability of provider-profiling systems. It is very important to standardize profiling criteria for the reliability of provider profiling system.

Comparison of five international indices of adherence to the Mediterranean diet among healthy adults: similarities and differences

  • Aoun, Carla;Papazian, Tatiana;Helou, Khalil;El Osta, Nada;Khabbaz, Lydia Rabbaa
    • Nutrition Research and Practice
    • /
    • v.13 no.4
    • /
    • pp.333-343
    • /
    • 2019
  • BACKGROUND/OBJECTIVES: To compare five indices of adherence to the Mediterranean Diet (MD) among adults living in the Mediterranean region. SUBJECTS/METHODS: A total of 100 healthy Lebanese adults aged between 18 and 65 years. Face-to-face interviews to collect sociodemographic and medical information, to take anthropometric measurements, and to fill a validated, culturally adapted, food frequency questionnaire (FFQ). The score for each item was calculated following the recommendations for each corresponding index. The five MD indices were Mediterranean Diet Scale (MDScale), Mediterranean Food Pattern (MFP), MD Score (MDS), Short Mediterranean Diet Questionnaire (SMDQ), and the MedDiet score. RESULTS: Significant correlations were detected between items with P-values < 0.001. Minimal agreement was seen between MDScale and MedDiet score and maximal agreement between MDS and MedDiet score. Univariate and multivariate analyses showed that MDS and MedDiet scores had significant correlations with fiber and olive oil intake, main components of the MD. MDScale showed a significant correlation with waist-to-hip ratio and with total energy intake but none of the five indices was correlated to body mass index (BMI). CONCLUSIONS: The indices that showed the highest correlation with variables related to the MD are the MDScale and the MedDiet score; therefore, they can be used to assess our future study populations. Based on the current results, more than half of the study population was non-adherent to the MD and adherence to this diet did not appear to protect against being overweight ($BMI{\geq}30$).

Quality Assurance of Intensity Modulated Radiation Therapy: Site-Specific Results of Eulji University Hospital (질환별 세기조절방사선치료의 정도관리: 을지대학병원 임상결과)

  • Kim, Sung-Jin;Lee, Mi-Jo;Youn, Seon-Min
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.99-106
    • /
    • 2011
  • Purpose: To analyze our quality assurance (QA) data for intensity modulated radiation therapy (IMRT) according to treatment site and to possibly improve QA for IMRT in Hospital. Materials and Methods: We performed QA on 50 patients (head and neck, 28 patients; Breast, 14 patients; Pelvis, 8 patients) for IMRT. The calculated dose from RTP was compared with the measured value film, gamma index, and ionization chamber for dose measurement in each case. Results: The point dose measurement results in 45 of 50 patients showed good agreement with the calculation dose (${\pm}3%$). The largest error measured thus far has been 3.60%, with a mean of only -0.17% (SD, 2.25%). Each treatment site showed an error rate of -0.13% (SD, 1.93%) for head and neck cases, -0.26% (SD, 2.79%) for breast cases, and 0.24% (SD, 2.44%) for pelvis cases. The gamma index verified with the error rate of head and neck cases (6%), breast (10%), and pelvis (6%), which corresponded to a tolerance of 3 mm (3% for the head and neck, 2%, for the breast 1% for the pelvis, and 0% in the region where the isodose curve was greater than 90%. Conclusion: We recognize the cause of errors for each treatment site of IMRT QA and so we maximize our efforts to reduce error and increase accuracy.

Prognostic Impact of Charlson Comorbidity Index Obtained from Medical Records and Claims Data on 1-year Mortality and Length of Stay in Gastric Cancer Patients (위암환자에서 의무기록과 행정자료를 활용한 Charlson Comorbidity Index의 1년 이내 사망 및 재원일수 예측력 연구)

  • Kyung, Min-Ho;Yoon, Seok-Jun;Ahn, Hyeong-Sik;Hwang, Se-Min;Seo, Hyun-Ju;Kim, Kyoung-Hoon;Park, Hyeung-Keun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.42 no.2
    • /
    • pp.117-122
    • /
    • 2009
  • Objectives : We tried to evaluate the agreement of the Charlson comorbidity index values(CCI) obtained from different sources(medical records and National Health Insurance claims data) for gastric cancer patients. We also attempted to assess the prognostic value of these data for predicting 1-year mortality and length of the hospital stay(length of stay). Methods : Medical records of 284 gastric cancer patients were reviewed, and their National Health Insurance claims data and death certificates were also investigated. To evaluate agreement, the kappa coefficient was tested. Multiple logistic regression analysis and multiple linear regression analysis were performed to evaluate and compare the prognostic power for predicting 1 year mortality and length of stay. Results : The CCI values for each comorbid condition obtained from 2 different data sources appeared to poorly agree(kappa: 0.00-0.59). It was appeared that the CCI values based on both sources were not valid prognostic indicators of 1-year mortality. Only medical record-based CCI was a valid prognostic indicator of length of stay, even after adjustment of covariables($\beta$ = 0.112, 95% CI = [0.017-1.267]). Conclusions : There was a discrepancy between the data sources with regard to the value of CCI both for the prognostic power and its direction. Therefore, assuming that medical records are the gold standard for the source for CCI measurement, claims data is not an appropriate source for determining the CCI, at least for gastric cancer.

The Effects of Turbulent Atmosphere on Terrestrial Optical ASK Communication Systems (교란대기가 ASK 지상 광통신(光通信)시스템에 미치는 영향)

  • Hong, Kwon-Eui;Kim, June-Hwan;Jung, Jin-Ho;Kim, Yung-Kwon
    • Journal of IKEEE
    • /
    • v.1 no.1 s.1
    • /
    • pp.156-163
    • /
    • 1997
  • Since the wireless optical communications system transmits informations through the atmosphere, it is subject to many effects of the constituent materials of atmosphere. The turbulence effect always exists in both clear and cloudy days. It causes a beam wandering, breathing, and scintillation. These disadvantageous phenomena degrade the performance of an optical communications system. In this paper, I designed a refractive index measuring system and subcarrier ASK optical communications system. Through this system I measured refractive index in May and in August. From these measurements, the minimum value of the refractive index in these period was about ${\approx}10^{-15}[m^{-2/3}]$ at night time and the maximum value was about ${\approx}10^{-12}[m^{-2/3}]$ at day time. The refractive index structure parameter. BER(bit error rate), and the burst length were measured simultaneously in these measurements. the theoretically predicted BER and the measured values showed a good agreement.

  • PDF