• 제목/요약/키워드: Aging Diagnosis

검색결과 350건 처리시간 0.025초

표면방전의 집중에 따른 옥외용 설비의 성능평가 (The Estimation of Outdoor Insulation According to the Concentration of Surface Discharge)

  • 임장섭;정승천;이진;노진양
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.212-216
    • /
    • 2001
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outdoor insulator because those testing can carry out very short time in Lab-testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outdoor HV machine/system. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab-testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from procelain insulator, used 22.9[KV] distribution, is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in SD concentration according to applied time.

  • PDF

인위적 열화 애자에 대한 누설전류와 온도와의 관계 (Correlation between leakage current and temperature Rise for artificially aged insulators)

  • 김정태;김지홍;구자윤;윤지호;함길호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.186-188
    • /
    • 2001
  • In this study, the correlation between leakage currents and temperature rise was investigated for the more accurate diagnosis of bad insulator by use of the infrared camera. For the purpose, leakage currents and thermal images were measured for the artificially aged insulators using salt fog. From the results, it is concluded as follows ; in case of artificially aged insulators, the leakage. current was decreased with the duration of voltage application and was largely affected by humidity, which seems due to ionic conduction. Also, the correlation between temperature rise and leakage current was appeared to be quite linear, although it showed below linearity at large leakage current.

  • PDF

파괴수명예측을 통한 지중배전용 전력케이블의 열화 진단 (Aging Diagnosis of Underground Distribution Power Cables Using Breakdown Lifetime Prediction)

  • 김충배;이정빈;임장섭;장영학;이진;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.222-225
    • /
    • 1999
  • Degradation diagnosis of XLPE insulated URD cables was accomplished through out new method. which was to be analyzed non-electrical experiments and synthesized by degradation points. To supplement this method, it was also carried out using several electrical analyses. Breakdown voltages were measured and breakdown lifetimes were Predicted appling for Weibull distribution function. As a result, breakdown lifetime in failure cables was shorted up to 1/3 times than that in general cables. It was very available to estimate cable degradation using above method, but it needs further study on XLPE insulated URD cables in order to improve reliability.

  • PDF

PD패턴과 방전량의 통계적 분포 및 정규화 (The Normalization and Statistical Distril in Partial Discharge Quantities and Patter)

  • 임장섭;이진;김덕근
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.161-164
    • /
    • 1999
  • Estimation system of aging diagnosis using partial discharge(PD) is being highlighted as a research area for the residual lifetime pridiction of industrial equipment. But the application of PD requires complicated analysis method as expert system because the PD has complex progressing forms according to external stress. In this paper, it has been investigated the statistical distribution to express the 2D PD patterns of the diagnosis system using neural network(NN).

  • PDF

견인전동기의 고장예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 절연저항 및 성극지수 특성 연구 (Condition Diagnosis by the Complex Accelerating Degradation for fault Prediction & estimation of reliability on the traction motor - Insulation Resistance & Polarization Index Properties)

  • 왕종배;변윤섭;백종현;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1374-1376
    • /
    • 2000
  • In this paper, sample coils for stator form-wound winding of traction motor were tested by the accelerative thermal degradation, which composed of heat, vibration, moisture and overvoltage applying. Reliability and expected life were evaluated on the insulation system for 200 class traction motor. After aging of 10 cycles, insulation resistance and PI properties were investigated as diagnosis tests in the range of $20{\sim}160^{\circ}C$. Analysis of polarization properties was performed on the base of do current-time change.

  • PDF

A Vehicle SoC Fault Diagnosis Technique using FlexRay Protocol

  • Kang, Seung-Yeop;Jung, Ji-Hun;Park, Sung-Ju
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권1호
    • /
    • pp.39-47
    • /
    • 2016
  • In this paper, we propose vehicle SoC fault diagnosis platform using FlexRay protocol in order to detect the faults of semiconductor control chip even after vehicle production. Before FlexRay protocol by sending NFI (Null Frame Indicator) bit among the header segment and a specific identifier in the payload segment of FlexRay frame, this technique can be distinguishable from normal mode and test mode. By using this technique, it is possible to detect the faults such as performance degradation of vehicle network system caused by the aging or several problems of vehicle semiconductor chip. Also high reliability and safety of vehicle can be maintained by using structural test for vehicle SoC fault detection.

적외선방사카메라를 이용한 트래킹열화 온도분포 (Temperature Distribution of Tracking Degradation Using IRR-Camera)

  • 정승천;임장섭;천종철;정우성;이진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.59-63
    • /
    • 2000
  • The conventional tracking testing as IEC-60587 is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of outside HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IIR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, SD occurred from IEC-60587 is measured with partial temperature distribution in real time, the degradation grade of SD is analyzed through produced patterns in IEC-60587 according to applied time.

  • PDF

적외선 모니터링 관측의 와이블 분포해석 (The Analysis of Weibull Distribution on the Monitoring of IRR Camera)

  • 임장섭;김진국;이학현;이진;이우선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.264-267
    • /
    • 2004
  • The conventional testing as IEC-60587 is widely used in surface aging measurement of outside insulator those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of out side HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis.

  • PDF

변압기 온도 변화특성 모니터링 (Temperature Distribution Monitoring of Transformer)

  • 이우선;정찬문;손동민;서용진;임장섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

터널시설물 점검진단 데이터의 텍스트마이닝 분석을 통한 유형별·지역별 중점 유지관리요소의 이해 (Understanding Facility Management on Tunnel through Text Mining of Precision Safety Diagnosis Data)

  • 서정은;오진탁
    • 한국공간구조학회논문집
    • /
    • 제21권3호
    • /
    • pp.85-92
    • /
    • 2021
  • The purpose of this paper is to understand the key factors for efficient maintenance of rapidly aging facilities. Therefore, the safety inspection/diagnosis reports accumulated in the unstructured data were collected and preprocessed. Then, the analysis was performed using a text mining analysis method. The derived vulnerabilities of tunnel facilities can be used as elements of inspections that take into account the characteristics of individual facilities during regular inspections and daily inspections in the short term. In addition, if detailed specification information and other inspection results(safety, durability, and ease of use) are used for analysis, it provides a stepping stone for supporting preemptive maintenance decision-making in the long term.