• 제목/요약/키워드: Aerosol Particle

검색결과 666건 처리시간 0.018초

에어로졸 공정에 의한 Graphene-$TiO_2$ 복합체 제조 및 염료감응 태양전지 특성평가 (Preparation of graphene-$TiO_2$ composite by aerosol process and it's characterization for dye-sensitized solar cell)

  • 조은희;김선경;장희동;장한권;노기민;김태오
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.51-57
    • /
    • 2013
  • A graphene(GR)-$TiO_2$ composite was synthesized from colloidal mixture of graphene oxide(GO) nanosheets and $TiO_2$ nanoparticles by an aerosol assisted self-assembly. The morphology, specific surface area and pore size of asprepared GR-$TiO_2$ composite were characterized by FE-SEM, BET, and BJH respectively. The shape of GR-$TiO_2$ composite was spherical. The average particle size was 0.5-1 ${\mu}m$ in diameter and the pore diameter ranged 20-50 nm. Photovoltaic characteristics of a mixture of the GR-$TiO_2$ and $TiO_2$ nanoparticles were measured by a solar simulator under simulated solar light. The highest photoelectric conversion efficiency of the mixture photoanode was 5.1%, which was higher than that of $TiO_2$ photoanode.

광산란방식을 이용한 미세먼지 실시간 모니터링 장치 개발 및 성능평가 (Development and Performance Evaluation of a Real-time PM Monitor based on Optical Scattering Method)

  • 강두수;오정은;이상열;신희준;봉하경;김대성
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.107-119
    • /
    • 2018
  • In this study, we have developed a real-time monitoring device for measuring PM10 and PM2.5 of ambient aerosol particles. The real-time PM monitor (SENTRY Dust Monitor) uses the optical scattering method and has 16 channels in particle size. The laboratory and field tests were carried out to evaluate the developed SENTRY Dust Monitor. Arizona Test Dust particles were used as test particles in the laboratory test and the field test was carried out at the Jongno-gu Observatory in Seoul. The measurements of PM10 and PM2.5 concentrations obtained by SENTTRY Dust Monitor were compared with Grimm Dust Monitor (Model 1.108) and a beta ray gauge. It was shown that the PM10 and PM2.5 concentrations obtained by SENTRY Dust Monitor agree well with that of the reference devices. Based on the results obtained in this study, it could be concluded that the SENTRY Dust Monitor can be used as a PM monitoring device for real-time monitoring of the ambient aerosols.

Dual-PDA를 이용한 절삭유 에어로졸 특성분석에 관한 연구(II) - 선삭공정의 절삭유 에어로졸 예측 (A Study on the Characteristics Analysis of Cutting Fluid Aerosol Using Dual-PDA System(II) - for Cutting Fluid Aerosol Prediction in Turning Process)

  • 정의식;황덕철;우창기;황준
    • 한국분무공학회지
    • /
    • 제10권2호
    • /
    • pp.32-40
    • /
    • 2005
  • This paper presents the analytical approaches to predict cutting fluid aerosol formation characteristics in machining process. The prediction model which is based on the rotary atomization theory analyzes aerosol behaviors in terms of size and concentration. Experiments were tarried out to verify the aerosol formation prediction model under various operational conditions. The experimental results which are obtained by Dual-PDA measurement show resonable agreement with prediction results of aerosol concentration. This study can be provided as a basis to estimate and control the hazardous cutting fluid aerosol in machining process in view of environmental consciousness.

  • PDF

Faraday cup array 개발을 위한 Particle Beam Mass Spectrometer 시스템 내에서의 입자 확산 연구 (A Study on Particle Diffusion to Develop Faraday Cup Array of Particle Beam Mass Spectrometer System)

  • 문지훈;신용현;김태성;강상우
    • 한국입자에어로졸학회지
    • /
    • 제8권1호
    • /
    • pp.29-35
    • /
    • 2012
  • The Faraday cup electrode of different size has been developed and evaluated to investigate the diffusion effect of particles by Brownian motion in a particle beam mass spectrometer(PBMS). Particles which focused and accelerated by aerodynamic lens are charged to saturation in an electron beam, and then deflected electrostatically into a Faraday cup detector for measurement of the particle current. The concentration of particles is converted from currents detected by Faraday cup. Measurements of particle current as a function of deflection voltage are combined with measured relationships between particle velocity and diameter, charge and diameter, and mass and diameter, to determine the particle size distribution. The particle currents were measured using 5, 10, 20, 40 mm sized Faraday cup that can be move to one direction by motion shaft. The current difference for each sizes as a function of position was compared to figure out diffusion effect during transport. Polystyrene latex(PSL) 100, 200 nm sized standard particles were used for evaluation. The measurement using 5 mm sized Faraday cup has the highest resolution in a diffusion distance and the smaller particles had widely diffused.

에어로졸 입자의 중력응집에 관한 실험 및 수치적 연구 (Experimental and Numerical Study of Aerosol Coagulation by Gravitation)

  • 권순박;이규원
    • 한국대기환경학회지
    • /
    • 제16권1호
    • /
    • pp.1-10
    • /
    • 2000
  • The behavior of aerosos due to gravitational coagulation was studied experimentally and numerically. In experimental study, the geometric mean particel size increased as time elapsed in a vertical tube column, while the size decreased when the tube was set horizontally. The particle size distribution was observed to maintain the lognormal form during the coagulation process. Separately, numerical calculations were performed for studying the aerosol behavior under gravitational and Brownian coagulation using the moment method. By comparing the expeimented results with the numerical predictions, the governing mechanism of the aerosol behavior proved to be gravitational coagulation.

  • PDF

Effects of Spray Surfactant and Particle Charge on Respirable Coal Dust Capture

  • Tessum, Mei W.;Raynor, Peter C.
    • Safety and Health at Work
    • /
    • 제8권3호
    • /
    • pp.296-305
    • /
    • 2017
  • Background: Surfactant-containing water sprays are commonly used in coal mines to collect dust. This study investigates the dust collection performance of different surfactant types for a range of coal dust particle sizes and charges. Methods: Bituminous coal dust aerosol was generated in a wind tunnel. The charge of the aerosol was either left unaltered, charge-neutralized with a neutralizer, or positively- or negatively-charged using a diffusion charger after the particles were neutralized. An anionic, cationic, or nonionic surfactant spray or a plain water spray was used to remove the particles from the air flow. Some particles were captured while passing through spray section, whereas remaining particles were charge-separated using an electrostatic classifier. Particle size and concentration of the charge-separated particles were measured using an aerodynamic particle sizer. Measurements were made with the spray on and off to calculate overall collection efficiencies (integrated across all charge levels) and efficiencies of particles with specific charge levels. Results: The diameter of the tested coal dust aerosol was $0.89{\mu}m{\pm}1.45$ [geometric $mean{\pm}geometric$ standard deviations (SD)]. Respirable particle mass was collected with $75.5{\pm}5.9%$ ($mean{\pm}SD$) efficiency overall. Collection efficiency was correlated with particle size. Surfactant type significantly impacted collection efficiency: charged particle collection by nonionic surfactant sprays was greater than or equal to collection by other sprays, especially for weakly-charged aerosols. Particle charge strength was significantly correlated with collection efficiency. Conclusion: Surfactant type affects charged particle spray collection efficiency. Nonionic surfactant sprays performed well in coal dust capture in many of the tested conditions.

원자로건물 내부 방사성 에어로졸 입자의 특성 (Characteristics of Radioactive Aerosol Particles in Nuclear Power Plant Containments)

  • 김민영;박성훈
    • 한국입자에어로졸학회지
    • /
    • 제10권4호
    • /
    • pp.137-154
    • /
    • 2014
  • 문헌조사를 통해 그동안 선행연구로부터 밝혀진 방사성 에어로졸의 특성을 종합하고 정리하였다. 가상사고 실험 중 각재계통 및 원자로건물에서 측정한 에어로졸의 특성, 냉각재계통 및 원자로건물에서의 방사성 에어로졸 거동 해석을 위해 사용된 모델 에어로졸의 특성, 공학적 안전설비 성능평가를 위한 실험에 사용된 모델 에어로졸의 특성 등과 관련한 선행연구 내용을 종합해 볼 때, 원전사고 시 발생하는 에어로졸의 MMD는 $0.1{\sim}5{\mu}m$, GSD는 1.33~2.9, 에어로졸 농도는 $0.06{\sim}132g/m^3$의 범위를 보였다. 향후 공학적 안전설비의 설계를 위한 MMD와 GSD의 대표값은 대략 $1.5{\mu}m$와 1.8 내외라고 할 수 있으며, 에어로졸 농도는 대략 $10g/m^3$을 대표값으로 볼 수 있다.

해염성분에 의한 에어로솔 물성변화 모사연구 (A Modeling Study on Aerosol Property Changes due to Sea-Salts)

  • 김용표
    • 한국대기환경학회지
    • /
    • 제16권2호
    • /
    • pp.113-120
    • /
    • 2000
  • Effects of sea-salts on the properties of aerosol collected in a coastal region were studied by applying a gas-particle equilibrium model SCAPE to the measurement data from Korea Cheju Island in summer 1994. It was found that the observed higher ammonium concentrations in fine particles (PM2.5) than in TSP were caused by forced evaporation of ammonium in coarse fraction of aerosol by sea-salts and the degree of evaporation was quantified through an application of SCAPE. By subtracting the sea-salt fraction from the measured concentra-tions the changes of aerosol property were also studied. The concentrations of nitrate at both TSP and PM2.5 decreased when alkaline sea-salt fraction was removed from the measured data. Estimates of aerosol acidity increased for most samples with sea salt loadings, However in some cases with high mass fractions of sea-salt components the aerosol acidity of PM2.5 decreased slightly. This is though to be related with the formation of solid salt with the removal of sea-salts.

  • PDF

다양한 조건의 저압 공정 모니터링을 위한 입자 집속 장치 개발 (Development of particle focusing device to monitor various low pressure processes)

  • 김명준;김동빈;강상우;김태성
    • 한국입자에어로졸학회지
    • /
    • 제13권2호
    • /
    • pp.53-63
    • /
    • 2017
  • As semiconductor process was highly integrated, particle contamination became a major issue. Because particle contamination is related with process yields directly, particles with a diameter larger than half pitch of gate should be controlled. PBMS (Particle beam mass spectrometry) is one of powerful nano particle measurement device. It can measure 5~500 nm particles at ~ 100 mtorr condition in real time by in-situ method. However its usage is restricted to research filed only, due to its big device volume and high price. Therefore aperture changeable aerodynamic lenses (ACALs) which can control particle focusing characteristics by changing its aperture diameter was proposed in this study. Unlike conventional aerodynamic lenses which changes particle focusing efficiency when operating condition is changed, ACALs can maintain particle focusing efficiency. Therefore, it can be used for a multi-monitoring system that connects one PBMS and several process chambers, which greatly improves the commercialization possibility of the PBMS. ACALs was designed based on Stokes number and evaluated by numerical method. Numerical analysis results showed aperture diameter changeable aerodynamic lenses can focus 5 to 100 nm standard particles at 0.1 to 10 torr upstream pressure.

사무용기기에서 발생되는 미세입자 측정 및 분석방법 연구 (Particle Emission Characteristics and Measurement of Ultrafine Particles from Laser Printer)

  • 이경환;김선만;안강호
    • 한국입자에어로졸학회지
    • /
    • 제6권3호
    • /
    • pp.123-129
    • /
    • 2010
  • As the indoor activity increases in recent years, the indoor air quality becomes more important. One of the major contaminants in office space is the copy machines and the laser based printers. These devices usually emit nano-particles and chemical species that may give some health effect. The amount of particles generated by the printers and copy machines depend on printer models, printing speed, toners, papers, humidity and so on. To evaluate the emission rate of nano-particles from Laser Printers, the mass concentration measurement method has been used (BAM, 2004). However, the mass concentration measurement method for nano-particles is tedious and time consuming. Therefore, for the development of a new nano-particle counting method, the nano-particle emission characteristics and size distributions are evaluated.