• Title/Summary/Keyword: Advanced water treatment system

Search Result 202, Processing Time 0.034 seconds

Evaluation of Water Treament System for Phenol Removal in the Nakdong River Basin (낙동강 수계 페놀처리를 위한 정수처리시스템 평가)

  • Kang, Byung-Jae;Chae, Seon-Ha;Lee, Kyung-Hyuk;Jeon, Hang-Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.609-618
    • /
    • 2009
  • Repeated phenol spill in the Nakdong River has been a big issue in Korea since 1991. In this study, treatment of phenol in each water treatment process and total water treatment system is evaluated. Phenol was highly volatile, easily oxidized by ozone, and readily absorbed onto GAC. When there was phenol of 0.3mg/L in water, by ozonation of 1mg/L or by GAC adsorption with EBCT of 10minutes or longer, it could be treated to lower than 0.005mg/L, the national drinking water standard of phenol. Even when a sufficient contact time(70minutes) was allowed, only 35 to 40% of phenol could be removed by powdered activated carbon(PAC). Based on the test results, it can be concluded that 1.0mg/L or less concentration of phenol can be treated at the plants adopting the combination process of ozone and GAC down to the safe level. In this study, removal characteristics for phenol were evaluated with the existing pilot plant and demo plant in different advanced water treatment processes(AWTPs). In the future, studies on changes in oxidation and adsorption characteristics caused by competitive matters such as DOC and removal characteristics by other various AWTPs including ozone/filter adsorber need to be performed.

Application of Advanced Treatment Process for Nitrogen Compounds Removal of Industrial Waste-water (산업폐수 중의 질소 성분의 제거를 위한 고도처리 공정의 응용)

  • Bhang, Sung-Hun;Lim, Eun-Tae;Jeong, Gwi-Taek;Park, Jae-Hee;Park, Seok-Hwan;Kim, Seong-Jun;Park, Don-Hee
    • KSBB Journal
    • /
    • v.23 no.6
    • /
    • pp.541-545
    • /
    • 2008
  • This paper was studied to research regarding the removal of contained nitrogen in industrial wastewater which uses the A2O4 advanced water treatment process. The field researches of two companies' wastewater occurred in each wastewater treatment site to apply the A2O4 process system, it was observed them for 20 days. As a result of the A2O4 system advanced wastewater process which applied an altitude control process obtained $10{\sim}76\;mg/L$, and 20 mg/L total nitrogen compound concentration in the two wastewater plants. In conclusion, it applied the A2O4 system in the two companies' wastewater system.

Implementation of magnetic Fe3O4@ZIF-8 nanocomposite to activate sodium percarbonate for highly effective degradation of organic compound in aqueous solution

  • Sajjadi, Saeed;Khataee, Alireza;Soltani, Reza Darvishi Cheshmeh;Bagheri, Nafiseh;Karimi, Afzal;Azar, Amirali Ebadi Fard
    • Journal of Industrial and Engineering Chemistry
    • /
    • v.68
    • /
    • pp.406-415
    • /
    • 2018
  • Here, as-synthesized $Fe_3O_4$ nanoparticles were incorporated into the zeolitic imidazolate framework (ZIF-8) lattice to activate sodium percarbonate (SPC) for degradation of methylene blue (MB). The reaction rate constant of $Fe_3O_4@ZIF-8/SPC$ process ($0.0632min^{-1}$) at acidic conditions (pH = 3) was more than six times that of the $Fe_3O_4/SPC$ system ($0.009min^{-1}$). Decreasing the solute concentration, along with increasing SPC concentration and $Fe_3O_4@ZIF-8$ nanocomposite (NC) dosage, favored the catalytic degradation of MB. The $Fe_3O_4@ZIF-8$ NC after fifteen consecutive treatment processes showed the excellent stability with a negligible drop in the efficiency of the system (<10%). The reaction pathway was obtained via GC-MS analysis.

A Study on Removal of Disinfection By-products in High Concentration Powdered Activated Carbon Membrane Bio-reactor Process for Advanced Water Treatment (고도정수처리를 위한 HCPAC-MBR 공정에서의 소독부산물 저감에 관한 연구)

  • Lee, Song-Hee;Jang, Sung-Woo;Seo, Gyu-Tae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2006
  • This study was conducted to evaluate the performance of a membrane bioreactor filled with high concentration of powdered activated carbon (HCPAC-MBR) to reduce DBPs at the drinking water treatment. The pilot system was installed after the rapid sand filtration process whose plant was the conventional treatment process. The removal efficiencies of DBPs were measured during pilot operation period of 2 years. HAA and THM removal rates could be maintained around 80~90% without any troubles and then tremendous reduction of HAA and THM reactivity were observed more than 52%. The average removal rate of HAA formation potential (FP) and THM formation potential (FP) were 70.5% and 67.6% respectively. It is clear that the PAC membrane bioreactor is highly applicable for advanced water treatment to control DBPs.

A Feasibility Review for an Uneven Baseline Basis Minimal Ballast Ship

  • Kang, Hee Jin;Kim, Kwang-Soo;Choi, Jin;Lee, Yeong-Yeon;Ahn, Haeseong;Yim, Geun-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.1
    • /
    • pp.1-12
    • /
    • 2020
  • Although there are many kinds of advanced ballast water management systems, pioneering studies for ballast-water free ship and minimal ballast water ship concepts are in progress. In this study, the existing alternatives of ballast water are reviewed and a new design concept is studied on the basis of the existing bulk carrier hull form. To develop a new design alternative which has minimal ballast for ballast water discharge free operation, the new concept should have technical feasibilities that are related to the role of the ballast water, berth access, loading constraints, etc. For this purpose, a simplified systems engineering basis design approach is adopted using a business model as the system analysis and control tool. To check the performance feasibility of the new concept, ship resistance performance is reviewed based on a model scale ship resistance performance analysis.

Shipboard Test of Ballast Water Treatment System by Ozonation

  • Park, Sung-Jin;Kim, Ki-Wook;Kim, In-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.3
    • /
    • pp.391-398
    • /
    • 2010
  • This study is currently giving priority to developing the ballast water treatment system using ozone(Ozone BWTS). The Ozone BWTS, were equipped on the real merchant vessel named as M. V. Hyundai Hong Kong to carried out shipboard tests of ballast water treatment system in accordance with orders of IMO G8 Guidelines. The study results show that the Ozone BWTS is capable of meeting the Ballast Water Performance Standard under Regulation D-.2 of the International Convention for the Control and Management of Ships’ Ballast Water and Sediments, and also the more stringent standards being proposed under US legislation.

Assessment of Micro Organic Pollutants Removal Using Advanced Water Treatment Process and Nanofiltration Process (고도처리공정과 나노여과공정에서의 미량유해물질 제거 평가)

  • Kang, Joon-Seok;Choi, Yang-Hun;Kwon, Soon-Buhm;Yu, Young-Beom
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.8
    • /
    • pp.579-587
    • /
    • 2014
  • Various kinds of micro organic pollutants have frequently been detected from a water system. Therefore, it is considered to be very important part in the drinking water treatment system. And the research about removal process and processing efficiency have been being conducted briskly. In this study, the removal efficiency was evaluated using advanced water treatment process and nanofiltration process. The removal efficiency of nanofiltration process was very different according to physical and chemical characteristics of materials. The molecular weight of cutoff was the most influential factor in the removal efficiency. And when pKa value was higher than pH of raw water or Log Kow value was below 2, the removal efficiency of material was decreased. In case of oxidation reaction, the bigger the molecular weight of material was and the more hydrophobic a material was, the less oxidation reaction occurred. And the removal efficiency was decreased. Most unoxidized materials were removed by absorption. And the more actively oxidation reaction occurred by $H_2O_2$, the more absorption reaction increased.

Evaluation of Advanced Water Treatment Operation

  • Kim, Seung-Hyun
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.54-64
    • /
    • 2002
  • This study evaluated advanced water treatment (AWT) system in Korea. There are currently 16 plants operating with AWT. However, no attempt has been made to evaluate AWT system. This study selected one water treatment plant with AWT (pre-ozonation + BAC). Using the operation data from 1995 to 2001 and pilot study results, the post-evaluation of the AWT system has been conducted. The study found that AWT improved water qualities of organic, ammonia, and turbidity, as expected. However, the extent of the improvement was generally short of the pilot study expectations. Pre-ozonation failed to decrease coagulant consumption. The dosage increased rather than decreased. AWT was, however, successful to decrease chlorine consumption. The chlorine reduction was related to the change in raw water characteristics and AWT introduction. Pre-ozonation failed to decrease coagulant consumption. The dosage increased rather than decreased. AWT was, however, successful to decrease chlorine consumption. The chlorine reduction was related to the change in raw water characteristics and AWT introduction, Both operation of pre-ozonation and reduced ammonia loading were responsible for the reduction. AWT increased the operation cost. Maintenance, raw water, and power cost increased, while labor and chemical cost decreased. Manpower reduction resulting form automation caused the decrease of labor cost. The reduction of chlorine consumption caused the decrease of chemical cost.

  • PDF

Experimental Study on Evaluation of Bond Strength after Ozone Treatment and Ozone Resistance of Concrete Metal Spray Coating for Advanced Water Treatment (고도정수처리용 콘크리트 금속용사 피막의 내오존성 및 오존처리 후 부착강도 평가에 관한 실험적 연구)

  • Park, Jin-Ho;Jang, Hyun-O;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • The introduction of advanced water treatment facilities has increased as the conventional purification method cannot remove the substance clearly. However, the internal waterproofing and Anticorrosion materials of the advanced water treatment facility using ozone deteriorate due to the oxidation power of ozone and affects the concrete, which causes a decrease in durability. This study is to evaluate the ozone resistance according to the type of spray metal and the surface treatment method of the coating, and the bond strength after ozone treatment in order to develope a finishing method to prevent deterioration of concrete structure of water treatment facility using metal spraying method as a way to construct metal panel with excellent ozone resistance and chemical resistance by an easier way than the previous. The Experimental results show that spray metal Ti has superior ozone resistance even after spraying. It is considered to be the most suitable method for ozone resistance and bond performance by finishing using Teflon sealing as surface treatment method.