• 제목/요약/키워드: Adsorption/Catalytic process

검색결과 57건 처리시간 0.03초

평판형 유전체 장벽 방전 반응기에서 충진물질에 따른 아세토나이트릴의 분해 특성 (Decomposition of Acetonitrile Using a Planar Type Dielectric Barrier Discharge Reactor Packed with Adsorption and Catalyst Materials)

  • 김관태;송영훈;김석준
    • 한국대기환경학회지
    • /
    • 제19권2호
    • /
    • pp.157-165
    • /
    • 2003
  • A combined process of non-thermal plasma and catalytic technique has been investigated to treat $CH_3$CN gas in the atmosphere. A planar type dielectric barrier discharge (DBD) reactor has been used to generate the non-thermal plasma that produces various chemically active species, such as O, N, OH, $O_3$, ion, electrons, etc. Several different types of the beads. which are Molecular Sieve (MS) 5A, MS 13X, Pt/alumina beads, are packed into the DBD reactor, and have been tested to characterize the effects of adsorption and catalytic process on treating the $CH_3$CN gas in the DBD reactor. The test results showed that the operating power consumption and the amounts of the by-products of the non-thermal plasma process can be reduced by the assistance of the adsorption and catalytic process.

Catalytic Oxidative and Adsorptive Desulfurization of Heavy Naphtha Fraction

  • Abbas, Mohammad N.;Alalwan, Hayder A.
    • Korean Chemical Engineering Research
    • /
    • 제57권2호
    • /
    • pp.283-288
    • /
    • 2019
  • Catalytic removal of sulfur compounds from heavy naphtha (HN) was investigated using a combination of an oxidation process using hydrogen peroxide and an adsorption process using granulated activated carbon (GAC) and white eggshell (WES). This study investigated the impact of changing several operating parameters on the desulfurization efficiency. Specifically, the volume ratio of $H_2O_2$ to HN (0.01~0.05), agitation speed ($U_{speed}$) of the water bath shaker ($100-500{\pm}1rpm$), pH of sulfur solution (1~5), amount of adsorbent (0.1~2.5 g), desulfurization temperature ($25{\sim}85{\pm}1^{\circ}C$) and contact time (10~180 minutes) were examined. The results indicate that the desulfurization efficiency resulting from catalytic and adsorption processes of GAC is better than that of WES for oxidation and removing sulfur compounds from HN due to its high surface area. The desulfurization efficiency depends strongly on all investigated operating parameters. The maximum removal efficiency of GAC and WES achieved by this study was 86 and 65, respectively.

모노리스 $NH_3-SCR$ 반응기 내에서의 $NH_3$ 흡.탈착 특성에 대한 연구 (A Study of $NH_3$ Adsorption/Desorption Characteristics in the Monolithic $NH_3-SCR$ Reactor)

  • 왕태중;백승욱;정명근;여권구
    • 한국자동차공학회논문집
    • /
    • 제14권3호
    • /
    • pp.125-132
    • /
    • 2006
  • Transient kinetics of $NH_3$ adsorption/desorption and of SCR(selective catalytic reduction) of NO with $NH_3$ were studied over vanadium based catalysts, such as $V_2O_5/TiO_2$ and $V_2O_5-WO_3/TiO_2$. In the present catalytic reaction process, NO adsorption is neglected while $NH_3$ is strongly chemisorbed on the catalytic surface. Accordingly, it is ruled out the possibility of a reaction between strongly adsorbed $NH_3$ and NO species in line with the hypothesis of an Eley-Rideal mechanism. The present kinetic model assumes; (1) non-activated $NH_3$ adsorption, (2) Temkin-type $NH_3$ coverage dependence of the desorption energy, (3) non-linear dependence of the SCR reaction rate on the $NH_3$ surface coverage. Thus, the surface heterogeneity for adsorption/desorption of $NH_3$ is taken into account in this model. The present study extends the pure chemical kinetic model based on a powdered-phase catalytic system to the chemico-physical one applicable to a realistic monolith reactor.

흡착/촉매 공정개선을 위한 사이클론 내 유동특성 및 활성탄 체류시간 산정 (Flow Characteristics and Residence Time of Activated Carbon in the Cyclone for Optimized Design of an Adsorption/Catalysis Reactor)

  • 최청렬
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.416-424
    • /
    • 2007
  • In adsorption/catalytic process, numerical analysis has been performed to identify the flow characteristics of flue gas in the cyclone and to estimate the residence time of activated carbon using Computational Fluid Dynamics (CFD) technique. To consider flue gas and activated carbon particles simultaneously, Euler-Lagrangian model was employed so that residence time could be obtained from the numerical analysis directly. The numerical analysis has been performed with different three particle sizes and compared each flow characteristics with particle’ size. Fundamental flow patterns of flue gas and activated carbon particles, pressure distribution, residence time of flue gas, and activated carbon particles and distribution of activated carbon have been obtained from the numerical analysis.

Thermal catalytic de-NOX 공정에서 첨가제가 촉매의 활성에 미치는 영향에 관한 연구 (Effect of Additives on Catalytic Activity in Thermal Catalytic De-NOx Process)

  • 이진구;김태원;최재순;김정호;이재수;장경욱;박해경
    • 한국대기환경학회지
    • /
    • 제15권3호
    • /
    • pp.249-255
    • /
    • 1999
  • We sdudied effect of additives on catalytic activity in thermal catalytic de-NOx process which was composed of thermal reduction, catalytic reduction and catalytic oxidation stage. Pd-Pt/${\gamma}$-$Al_2O_3$ catalysts with the addition of transition metals(Co, Cu, Fe, Ni, W, Zn, Zr) and rare earth metals(Ce, Sr) were prepared by the conventional washcoating method. Those catalysts were characterized by CO pulse chemisorption, ICP, $N_2$ adsorption, SEM and XRD. The effect of catalyst additives on NOx removal for diesel emission was studied in thermal catalytic de-NOx process at reduction temperature(350~50$0^{\circ}C$), space velocity(5,000~20,000 $hr^{-1}$) and the engine load(0~120kW). The concentraton of CO, $CO_2$, NO and $NO_2$ in the exhaust gas increased with the engine load. On the other hand the concentration of $O_2$ decreased. The de-NOx activityof all prepared catalysts increased with respect to high CO and low $O_2$ level in the thermal reduction stage of the process. Insertion of Ce to Pt-Pd/${\gamma}$-$Al_2O_3$ catalyst showed the best activity of all the catalysts under these experimental conditions. De-NOx catalysts are effective to remove CO in addition to NOx in the catalytic reduction stage.

  • PDF

Estimation of VOCs Emissions from Small-Scale Surface Coating Facilities in Seoul

  • Jin-Ho, SHIN;Woo-Taeg, KWON
    • 웰빙융합연구
    • /
    • 제6권1호
    • /
    • pp.17-22
    • /
    • 2023
  • Purpose: VOCs (volatile organic compounds) are all the organic compounds that react with solar rays and increase the concentration of ozone in the troposphere and are partially also known as carcinogens. The adsorption using activated carbon is usually applied to remove VOCs. Research design, data and methodology: The 20 places of surface coating facilities were selected to evaluate the emission amount of VOCs in Seoul. In addition, the removal efficiency of VOCs in 25 places of automobile coating facilities was evaluated. Results: The average emission amount of VOCs was 10.903 kg/hr from automobile coating facilities, while 3.520 kg/hr from other surface coating facilities. The removal efficiency in adsorption with the combustion catalytic process has the mean value of 87.9% and the regeneration efficiency of activated carbon has the mean value of 95.0%. Conclusions: The removal efficiency in adsorption with the biofiltration process has the mean value of 89.8% and the regeneration efficiency of activated carbon has the mean value of 94.8%. The removal efficiency in the plasma catalyst process has the mean value of 79.3%.

연소 배출가스의 유입방식에 따른 백필터를 활용한 흡착/촉매 통합공정 시스템 반응기 내 유동특성 (Flow Characteristics with Inflow-Duct Types in the Reactor of an Integrated Adsorption/Catalysis Process with Bag Filters)

  • 최청렬
    • 대한기계학회논문집B
    • /
    • 제31권5호
    • /
    • pp.425-434
    • /
    • 2007
  • An integrated adsorption/catalytic process has been considered to treat dioxin and $NO_x$ simultaneously. The process consists of a cyclone and a reactor with nine bag filters. In this study, numerical analysis has been performed to understand flow characteristics with inflow-duct types in the reactor. To consider flue gas and activated carbon particles simultaneously, Euler-Lagrangian model was employed. Fundamental flow patterns of flue gas and activated carbon particles, pressure distribution and distribution of activated carbon have been obtained from the numerical analysis. Also trace length and residence time of flue gas, residence time of activated carbon particles have been calculated directly. Flow patterns of flue gas and activated carbon particles in the reactor were very complicated and they moved along very various paths. Therefore, their residence time in the reactor was also various. The flow characteristics in the reactor were strongly influenced by inflow-duct types. The results obtained would be effectively used to estimate the removal efficiency in the reactor once the residence time is combined with the reaction equation.

백필터를 활용한 흡착/촉매 통합공정 시스템의 반응기 내 유동특성 및 체류시간에 대한 수치해석적 연구 (Numerical Analysis on Flow Characteristics in the Reactor of an Integrated Adsorption/Catalysis Process with Bag Filters)

  • 최청렬;구윤서
    • 한국대기환경학회지
    • /
    • 제23권2호
    • /
    • pp.203-213
    • /
    • 2007
  • Numerical analysis has been performed to understand flow characteristics in the reactor with bag filters in an integrated adsorption/catalytic process which can treat dioxin and $NO_{x}$ together. Computational fluid dynamics technique was employed with Euler-Lagrangian model to consider flue gas and activated carbon particles simultaneously, so that residence time of flue gas and activated carbon particle could be obtained from the numerical analysis directly. The numerical analysis has been performed with different three particle sizes and compared each flow characteristics with particle's size. Fundamental flow patterns of flue gas and activated carbon particles, pressure distribution, residence time of flue gas and activated carbon particles, and distribution of activated carbon have been obtained from the numerical analysis. Flow patterns of flue gas and activated carbon particles in the reactor were very complicated and they moved along very various paths. Therefore, their residence time in the reactor was also various. The results obtained would be effectively used to estimate the removal efficiency in the reactor once the residence time is combined with the reaction equation.

Formation Fe2O3 Nanowalls through Solvent-Assisted Hydrothermal Process and Their Application for Titan Yellow GR Dye Degradation

  • Ahmed, Khalid Abdelazez Mohamed
    • 대한화학회지
    • /
    • 제58권2호
    • /
    • pp.205-209
    • /
    • 2014
  • Hematite iron oxide (${\alpha}$-$Fe_2O_3$) nanowalls were fabricated on aluminum substrate by a facile solvent-assisted hydrothermal oxidation process. The XRD and EDS patterns indicate that the sample has a rhombohedral phase of hematite $Fe_2O_3$. FE-SEM, TEM, HR-TEM, SA-ED were employed to characterize the resulting materials. $N_2$ adsorption-desorption isotherms was used to study a BET surface area. Their capability of catalytic degradation of titan yellow GR azo dye with air oxygen in aqueous solution over $Fe_2O_3$ catalysts was studied. The result indicates that the as-prepared product has a high catalytic activity, because it has a larger surface area. Langmuir and Freundlich isotherms of adsorption dye on the catalysts surface were investigated and the decomposition of titan yellow GR follows pseudo-first order kinetic.

Removal of toxic hydroquinone: Comparative studies on use of iron impregnated granular activated carbon as an adsorbent and catalyst

  • Tyagi, Ankit;Das, Susmita;Srivastava, Vimal Chandra
    • Environmental Engineering Research
    • /
    • 제24권3호
    • /
    • pp.474-483
    • /
    • 2019
  • In this study, iron (Fe) impregnated granular activated carbon (Fe-GAC) has been synthesized and characterized for various properties. Comparative studies have been performed for use of Fe-GAC as an adsorbent as well as a catalyst during catalytic oxidation of hydroquinone (HQ). In the batch adsorption study, effect of process parameter like initial HQ concentration ($C_o=25-1,000mg/L$), pH (2-10), contact time (t: 0-24 h), temperature (T: $15-45^{\circ}C$) and adsorbent dose (w: 5-50 g/L) have been studied. Maximum HQ adsorption efficiency of 75% was obtained at optimum parametric condition of: pH = 4, w = 40 g/L and t = 14 h. Pseudo-second order model best-fitted the HQ adsorption kinetics whereas Langmuir model best-represented the isothermal equilibrium behavior. During oxidation studies, effect of various process parameters like initial HQ concentration ($C_o:20-100mg/L$), pH (4-8), oxidant dose ($C_{H2O2}:0.4-1.6mL/L$) and catalyst dose (m: 0.5-1.5 g/L) have been optimized using Taguchi experimental design matrix. Maximum HQ removal efficiency of 83.56% was obtained at optimum condition of $C_o=100mg/L$, pH = 6, $C_{H2O2}=0.4mL/L,$ and m = 1 g/L. Overall use of Fe-GAC during catalytic oxidation seems to be a better as compared to its use an adsorbent for treatment of HQ bearing wastewater.