• 제목/요약/키워드: Adiabatic

검색결과 763건 처리시간 0.03초

INFLUENCE OF CONSTANT HEAT SOURCE/SINK ON NON-DARCIAN-BENARD DOUBLE DIFFUSIVE MARANGONI CONVECTION IN A COMPOSITE LAYER SYSTEM

  • MANJUNATHA, N.;SUMITHRA, R.;VANISHREE, R.K.
    • Journal of applied mathematics & informatics
    • /
    • 제40권1_2호
    • /
    • pp.99-115
    • /
    • 2022
  • The problem of Benard double diffusive Marangoni convection is investigated in a horizontally infinite composite layer system consisting of a two component fluid layer above a porous layer saturated with the same fluid, using Darcy-Brinkman model with constant heat sources/sink in both the layers. The lower boundary of the porous region is rigid and upper boundary of the fluid region is free with Marangoni effects. The system of ordinary differential equations obtained after normal mode analysis is solved in closed form for the eigenvalue, thermal Marangoni number for two types of thermal boundary combinations, Type (I) Adiabatic-Adiabatic and Type (II) Adiabatic -Isothermal. The corresponding two thermal Marangoni numbers are obtained and the essence of the different parameters on non-Darcy-Benard double diffusive Marangoni convection are investigated in detail.

열손실량 보정을 통한 콘크리트 단열온도상승량 예측 장치 (Equipment for Measuring the Adiabatic Temperature Rise of Concrete by Compensating Heat Loss)

  • 진은웅;김진용;김진근
    • 콘크리트학회논문집
    • /
    • 제24권5호
    • /
    • pp.535-542
    • /
    • 2012
  • 매스 콘크리트에서 발생하는 수화열을 예측하기 위한 단열온도상승시험은 시험 비용이 고가이고 시공간상 제약으로 인해 한계가 있는 실정이다. 이에 신속하고 경제적이며 간편한 간이 수화열 측정 장치의 개발이 필요한 실정이다. 이 연구에서는 간이 수화열 측정 장치를 완성하기 전 단열 성능이 뛰어난 보온병에 콘크리트를 타설하고 열손실량을 보정하여, 간이 수화열 측정 장치의 타당성을 입증하고자 하였다. 열손실량을 정확히 예측하기 위해서는 측정 장치의 정확한 열손실계수를 추정하는 것이 필수적인데, 열손실계수는 단열 장치 내부의 수온 변화를 이용하여 추정하였다. 시험 결과 장치 고유의 열손실계수는 외부 온도와 습도, 내부 온도 변화에 크게 변하지 않는 것으로 드러났다. 실제 단열온도상승시험과 열손실량이 보정된 보온병의 단열온도상승량과의 검증 시험을 통해 이 연구의 객관성과 타당성을 입증할 수 있었다.

단열 모세관내 R600a의 유동 특성 (Flow Characteristics of R600a in an Adiabatic Capillary Tube)

  • 구학근
    • 한국산학기술학회논문지
    • /
    • 제11권2호
    • /
    • pp.449-454
    • /
    • 2010
  • 본 논문은 균질유동모델을 적용하여 단열 모세관내 R600a의 유동 특성을 이론적으로 조사하였다. 이 모델은 시뮬레이션 해석에 필요한 기본적인 질량, 에너지, 운동량 방정식에 근거하고 있다. 또한 2개의 마찰인자와 점성계수모델을 이용하여 유동특성을 조사하였다. R600a의 열역학 및 전달 물성치는 EES 물성치 코드를 이용하여 계산하였다. 작동변수들에 대한 기초 설계자료를 제공하고자 단열 모세관내 R600a의 유동 특성을 분석하였다. 본 연구의 작동변수에는 응축온도, 증발온도, 과냉각도, 모세관의 직경이 있다. 주요 결과를 요약하면 다음과 같다. R600a용 단열 모세관내 응축온도, 증발온도, 과냉각도, 관직경은 모세관 전체길이에 영향을 준다. 즉 R600a용 모세관 전체길이는 식(15)와 같은 상관식으로 나타낸다.

단열성 재료 함량에 따른 PET 원사의 기계적 물성 및 직물의 단열성에 관한 연구 (Study on the Mechanical Properties of PET Fiber and the Adiabatic Properties of PET Fabrics by their Adiabatic Material Contents)

  • 김태윤;권선민;채시현;정예담;조현제;최익성;김종원
    • 한국염색가공학회지
    • /
    • 제35권2호
    • /
    • pp.128-136
    • /
    • 2023
  • Recently, the automobile industry is developing as the demand for automo- biles increases due to industrial development and population growth. In addition, many studies are being conducted to reduce heat loss inside the automobiles in order to save energy inside the automobiles due to environmental regulations. In this study, alumina, nanosilicon, and aerogel, which are adiabatic materials, were filled in PET to manufacture yarn, identify physical and mechanical properties, and weave into fabric to confirm adiabatic performance. As the content of the adiabatic material increased, the tensile strength of the fibers filled with alumina and nanosilicon decreased greatly, and the adiabatic property slightly increased. The tensile strength of fibers filled with the aerogel decreased slightly, but the adiabatic properties were greatly increased. Therefore, it is considered to be due to the large volume fraction in the PET yarn due to the low density of the aerogel.

Symmetric Adiabatic Logic Circuits against Differential Power Analysis

  • Choi, Byong-Deok;Kim, Kyung-Eun;Chung, Ki-Seok;Kim, Dong-Kyue
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.166-168
    • /
    • 2010
  • We investigate the possibility of using adiabatic logic as a countermeasure against differential power analysis (DPA) style attacks to make use of its energy efficiency. Like other dual-rail logics, adiabatic logic exhibits a current dependence on input data, which makes the system vulnerable to DPA. To resolve this issue, we propose a symmetric adiabatic logic in which the discharge paths are symmetric for data-independent parasitic capacitance, and the charges are shared between the output nodes and between the internal nodes, respectively, to prevent the circuit from depending on the previous input data.

흐름 영각에 따른 강제공랭 모듈 주위의 열전달 특성에 관한 연구 (A Study on the Heat Transfer Characteristics Around a Surface-Mounted Air-Cooled Module for the Flow Angle-of-Attack)

  • 박상희;신대종
    • 대한기계학회논문집B
    • /
    • 제26권9호
    • /
    • pp.1267-1275
    • /
    • 2002
  • An experimental study was performed to investigate adiabatic wall temperature and heat transfer coefficient around a module cooled by forced air flow. The flow angle of attack to the module were 0$^{\circ}$and 45$^{\circ}$. In the first method, inlet air flow(1~7m/s) and input power.(3, 5, 7W) were varied after a heated module was placed on an adiabatic floor(320$\times$550$\times$1㎣). An adiabatic wall temperature was determinated to use liquid crystal film. In the second method to determinate heat transfer coefficient, inlet air flow(1~7m/s) and the heat flux of rubber heater(0.031~0.062W/$m^2$) were varied after an adiabatic module was placed on rubber heater covering up an adiabatic floor. Additional information is visualized by an oil-film method of the surface flow on the floor and the module. Plots of $T_{ad}$ and $h_{ad}$ show marked effects of flow development from the module and dispersion of thermal wake near the module. Certain key features of the data set obtained by this investigation may serve as a benchmark for thermal-design codes based on CFD.

HVOF 열용사 프로세스에서의 연소특성에 관한 수학적 모델링(I): 연소생성물의 화학조성 및 단열화염온도 (Mathematical Modeling of Combustion Characteristics in HVOF Thermal Spray Processes(I): Chemical Composition of Combustion Products and Adiabatic Flame Temperature)

  • 양영명;김호연
    • 한국연소학회지
    • /
    • 제3권1호
    • /
    • pp.21-29
    • /
    • 1998
  • Mathematical modeling of combustion characteristics in HVOF thermal spray processes was carried out on the basis of equilibrium chemistry. The main objective of this work was the development of a computation code which allows to determine chemical composition of combustion products, adiabatic flame temperature, thermodynamic and transport properties. The free energy minimization method was employed with the descent Newton-Raphson technique for numerical solution of systems of nonlinear thermochemical equations. Adiabatic flame temperature was calculated by using a Newton#s iterative method incorporating the computation module of chemical composition. The performance of this code was verified by comparing computational results with data obtained by ChemKin code and in the literature. Comparisons between the calculated and measured flame temperatures showed a deviation less than 2%. It was observed that adiabatic flame temperature augments with increase in combustion pressure; the influence was significant in the region of low pressure but becomes weaker and weaker with increase in pressure. Relationships of adiabatic flame temperature, dissociation ratio and combustion pressure were also analyzed.

  • PDF

계단시편의 간극이 단열전단밴드의 형성에 미치는 영향 (Effects of Clearance on the Formation of Adiabatic Shear Band in Stepped Specimen)

  • 유요한;전기영;정동택
    • 대한기계학회논문집
    • /
    • 제17권7호
    • /
    • pp.1700-1709
    • /
    • 1993
  • The stepped specimen which is subjected to step loading is modeled to study the initiation and growth of adiabatic shear band using explicit time integration finite element method. Three different clearance sizes are tested. The material model for the stepped specimen includes effects of strain hardening, strain rate hardening and thermal softening. It is found that the material inside the fully grown adiabatic shear band experiences three phase of deformation, (1) homogeneous deformation phase, (2) initiation/incubation phase, and (3) fast growth phase. The second phase of deformation is initiated after sudden shear stress drop which occurs at the same time regardless of the clearance size. The incubation time prior to fast growth phase increases, as the clearance size of the stepped specimen increases. Whereas, after incubation period, the growth rate of the adiabatic shear band decreases, as the clearance size decreases. It is also found that two adiabatic shear band may develop instead of one for the smaller clearance size.

사각공동내 자연대류에서 측면 단열벽에 의한 영향 (Effect of Adiabatic Sidewalls on Natural Convection in a Rectangular Cavity)

  • 허정환;정범진
    • 대한기계학회논문집B
    • /
    • 제34권9호
    • /
    • pp.825-834
    • /
    • 2010
  • 사각공동내 자연대류 열전달 실험에서, 단열벽에 의해 열전달이 저하가 관찰되는 영역을 실험적으로 그리고 수치해석적으로 평가하였다. $Gr_H$$1.53\times10^7$부터 $1.01\times10^{10}$까지 변화시키며, 단열벽이 존재할 때와 그렇지 않을 때를 구분하여 열전달률을 측정하였다. FLUENT 실험의 결과를 예측할 수 있는지 확인하고 실험으로 수행하기 어려운 매우 좁은 영역에 대해 FLUENT를 수행하였다. 실험과 FLUENT의 결과를 다른 연구와 비교한 바 일치함을 보였다. 단열벽이 전체 열전달에 미치는 영향은 예상과 같이 단열벽 근처의 매우 좁은 영역에 국한하여 나타남을 확인하였다. 본 연구는 유사성(Analogy) 원리를 이용하여 열전달계를 전기도금계의 물질전달계로 모사하는 방법론을 개발하는 과정에서 실험을 효율화하고자 하는 방안을 강구하기 위하여 추진되었다. 본 연구를 통하여 단열벽간 거리(전극의 폭)를 매우 줄일 수 있는 이론적 근거를 확보하였다.

ADCL 버퍼를 이용한 단열 논리회로용 AC 전원과 동기화된 저전력 클럭 발생기 설계 (Design of Low-power Clock Generator Synchronized with the AC Power Source Using the ADCL Buffer for Adiabatic Logics)

  • 조승일;김성권;하라다 토모치카;요코야마 미치오
    • 한국전자통신학회논문지
    • /
    • 제7권6호
    • /
    • pp.1301-1308
    • /
    • 2012
  • 본 논문에서는 ADCL(adiabatic dynamic CMOS logic) buffer를 이용한 단열 논리회로용 AC 전원과 동기화된 저전력 클럭 발생기를 제안한다. CMOS 논리회로의 전력 손실을 줄이고 ADCL의 저전력 동작을 위해서, 논리회로의 clock 신호는 AC 전원 신호와 동기화 되어야 한다. 설계된 Schmitt trigger 회로와 ADCL buffer를 사용한 ADCL 주파수 분주기를 이용하여 AC 신호와 단열동작을 위한 clock 신호가 발생된다. 제안된 저전력 클럭 발생기의 소비전력은 3kHz와 10MHz에서 각각 1.181uW와 37.42uW으로 시뮬레이션에서 확인하였다.