• Title/Summary/Keyword: Additional filter

Search Result 436, Processing Time 0.022 seconds

MultiFormat motion picture storage subsystem using DirectShow Filters for a Mutichannel Visual Monitoring System (다채널 영상 감시 시스템을 위한 다중 포맷 동영상 저장 DirectShow Filter설계 및 구현)

  • 정연권;하상석;정선태
    • Proceedings of the IEEK Conference
    • /
    • 2002.06d
    • /
    • pp.113-116
    • /
    • 2002
  • Windows provides Directshow for efficient multimedia streaming processings such as multimedia capture, storage, display and etc. Presently, many motion picture codecs and audio codecs are made to be used in Directshow framework and Windows also supports many codecs (MPEG4, H,263, WMV, WMA, ASF, etc.) in addition to a lot of useful tools for multimedia streaming processing. Therefore, Directshow can be effectively utilized for developing windows-based multimedia streaming applications such as visual monitoring systems which needs to store real-time video data for later retrieval. In this paper, we present our efforts for developing a Directshow Filter System supporting storage of motion pictures in various motion picture codecs. Our Directshow Filter system also provides an additional functionality of motion detection.

  • PDF

Tracking Performance Improvement of Optical Disk Drive System (광디스크 드라이브 시스템의 트랙 추종 성능 향상 방법)

  • Kim Hong Rok;Suh Il Hong
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.6
    • /
    • pp.372-375
    • /
    • 2005
  • The tracking performance of optical disk drive(ODD) system can be improved using disturbance observer(DOB). But, DOB was not easily applied in the ODD system because the additional microprocessor was needed. In this paper, we propose an error-based modified disturbance observer(EM-DOB) for ODD system. Due to the simplified structure of EM-DOB, the system is easily implemented to the digital control algorithm or the analog circuit. In these algorithms, disturbances rejection performance of system can be tuned as Q filter parameters are selected. Based on analysis of sensitivity function, three guidelines of Q filter design are suggested. Experimental results of DOB and EM-DOB are evaluated under the forced disturbances.

Decentralized Suboptimal $H_2$ Filtering : An Exact Model Matching Approach (완전 모형 일치 기법을 이용한 분산 준최적 $H_2$필터)

  • 조남훈;공재섭;서진헌
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.256-264
    • /
    • 1996
  • In this paper, the decentralized suboptimal H$_{2}$ filtering problem is considered. An additional term is added to the centralized optimal H$_{2}$ filter so that the whole filter is decentralized. We derive a necessary and sufficient condition for existence of proposed decentralized filters By employing the solution procedure for the exact model matching problem, we obtain a set of decentralized H$_{2}$ filters, and choose a suboptimal filter from this set of decentralized H$_{2}$ filters.

  • PDF

A simple method to optimize DC-bus capacitor in 3-phase shunt Active power filter system

  • Phan, Dang-Minh;Lee, Hong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.367-368
    • /
    • 2015
  • This paper introduces a shunt active power filter with a small DC bus capacitor by adding additional low-pass filter (LPF). The DC link voltage fluctuation is impressively suppressed with a small value in spite of the low value of DC-link capacitor under the steady-state condition. Consequently, the cost and volume of power converter are significantly reduced thanks to the reduced value of DC-bus capacitor. On the other hand, an indirect control strategy is used to maintain grid-side current when non-linear loads are connected to the system. By using proportional-integral (PI) and modified repetitive controller (RC) in dq0 frame, the calculation time is greatly decreased by 6 times compared with the conventional RC, and the number of measurement devices is also minimized. As a result, the acquired total harmonic distortion (THD) is lower than 2% regardless of the load conditions. Simulation results are carried out in order to verify the effectiveness of the proposed control strategy.

  • PDF

Measurement of cellulase activities

  • 편집실
    • The Microorganisms and Industry
    • /
    • v.11 no.1
    • /
    • pp.21-33
    • /
    • 1985
  • 이글은 다음과 같이 구성되어져 있다. preface 1) introduction 2) general information 3) folin protein determination 4) cellobiase assay 5) filter paper assay for saccharifying cellulase 6) carboxymethyl cellulase assay for endo-.betha.-1,4-glucanase 7) additional assay procedure for endoglucanase 8) evalutaiton of cellulase under process conditions 9) general remartks, references.

  • PDF

Rotor Fault Detection System for Inverter Driven Induction Motors using Currents Signals and an Encoder

  • Kim, Nam-Hun
    • Journal of Power Electronics
    • /
    • v.7 no.4
    • /
    • pp.271-277
    • /
    • 2007
  • In this paper, an induction motor rotor fault diagnosis system using current signals, which are measured using the axis-transformation method is presented. Inverter-fed motor drives, unlike line-driven motor drives, have stator currents which are rich in harmonics and therefore fault diagnosis using stator current is not trivial. The current signals for rotor fault diagnosis need precise and high resolution information, which means the diagnosis system demands additional hardware such as a low pass filter, high resolution ADC, an encoder and additional hardware. Therefore, the proposed axis-transformation method is expected to contribute to a low cost fault diagnosis system in inverter-fed motor drives without the need for any additional hardware. In order to confirm the validity of the developed algorithms, various experiments for rotor faults are tested and the line current spectrum of each faulty situation, using the Park transformation, is compared with the results obtained from the FFT(Fast Fourier Transform).

A Study on LLC Resonant Converter Employing Coupled Inductor to Reduce Output Current Ripple (커플드 인덕터를 활용하여 출력 전류 리플을 저감하는 LLC 공진형 컨버터에 관한 연구)

  • Lee, Yong-Chul;Kang, Min-Hyuck;Kang, Chan-Ho;Hong, Sung-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.23 no.3
    • /
    • pp.208-216
    • /
    • 2018
  • In this paper, an LLC resonant converter employing two coupled inductors on the secondary side of the converter is proposed. The conventional LLC converter exhibits serious power loss during secondary winding of the transformer because of generation of tremendous output current ripples. To overcome this problem, an LLC resonant converter with a current doubler as a rectifying circuit was recently proposed. However, the current-doubler rectifying circuit requires coupled inductors with a high coupling ratio to retain the designed resonance characteristics. Therefore, an additional hardware filter is required at the output stage to address large output current ripples. Additional design procedures are also necessary because the inductance component of the added filter affects the designed resonant network. To solve this issue, an LLC resonant converter employing two coupled inductors is proposed in this paper. Mathematical analysis shows that the proposed secondary-side current-doubler circuit does not affect the designed resonance characteristics. The operating principles and theoretical analyses are proven through a simulation and experiments with a 54 V/28 A prototype.

Processor Design Technique for Low-Temperature Filter Cache (필터 캐쉬의 저온도 유지를 위한 프로세서 설계 기법)

  • Choi, Hong-Jun;Yang, Na-Ra;Lee, Jeong-A;Kim, Jong-Myon;Kim, Cheol-Hong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.1
    • /
    • pp.1-12
    • /
    • 2010
  • Recently, processor performance has been improved dramatically. Unfortunately, as the process technology scales down, energy consumption in a processor increases significantly whereas the processor performance continues to improve. Moreover, peak temperature in the processor increases dramatically due to the increased power density, resulting in serious thermal problem. For this reason, performance, energy consumption and thermal problem should be considered together when designing up-to-date processors. This paper proposes three modified filter cache schemes to alleviate the thermal problem in the filter cache, which is one of the most energy-efficient design techniques in the hierarchical memory systems : Bypass Filter Cache (BFC), Duplicated Filter Cache (DFC) and Partitioned Filter Cache (PFC). BFC scheme enables the direct access to the L1 cache when the temperature on the filter cache exceeds the threshold, leading to reduced temperature on the filter cache. DFC scheme lowers temperature on the filter cache by appending an additional filter cache to the existing filter cache. The filter cache for PFC scheme is composed of two half-size filter caches to lower the temperature on the filter cache by reducing the access frequency. According to our simulations using Wattch and Hotspot, the proposed partitioned filter cache shows the lowest peak temperature on the filter cache, leading to higher reliability in the processor.

Comparison of Dose and Quality of Copper and Nickel Additional Filter Plate in Diagnostic X-ray Generator (진단용 엑스선 발생장치에서 부가 여과판에 따른 선량과 화질 비교)

  • Lee, Hyun-Kyung;Go, Yu-Rim;Park, Young-Kyeong;Han, Dong-Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.6
    • /
    • pp.459-466
    • /
    • 2017
  • The purpose of this study was to evaluate the difference of dose and image quality according to the material of the additional filter plate by selecting copper and nickel. First, the absorbed dose was measured using a Rando phantom setting the additional filter plates of copper and nickel None, 0.1 mm, 0.2 mm, and 0.3 mm under 120 kVp, and 6.3 mAs. Second, We acquired image according to filter thickness of copper and nickel. by changing the tube voltage of 90 kVp, 100 kVp, 110 kVp, 120 kVp and exposure indexes of 400, 800 and 1600. Third, we obtained the SNR and CNR values using the Image J program and evaluated quantitatively and then evaluated image quality. As a result, Absorbed dose measurements showed that nickel was higher than copper, and the absorbed dose decreased as the thickness increased(p<0.05). Furthermore, Quantitative analysis of images showed no significant difference between the two images according to change the voltage and the exposure index(p>0.05). In conclusion, this study confirms that the nickel addition plate can maintain the current image quality while reducing the exposure dose compared to copper.

Changes of Radiation Dose and Image Quality Due to Additional Filtration Material in Computed Radiography (Computed Radiography에서 Additional Filtration Material에 따른 Radiation Dose와 Image Quality의 변화)

  • Kwon, Soon-Mu;Cho, Hyung-Wook;Kang, Yeong-Han;Kim, Boo-Soon;Kim, Jung-Su
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.239-246
    • /
    • 2014
  • Filter absorbs low-energy X-ray to increase the average energy and reduces patient exposure dose. This study investigates if the materials of Mo and W could be used for the digital imaging device CR by conducting image assessment and dose measurement of SNR, FOM and histogram. In addition, measurement of beam quality was conducted depending on the material of the filter, and at the same time, a proper combination of filters was examined depending on the change in tube voltage (kVp). In regard to entrance skin dose, Mo filter showed the dose reduction by 42~56%, compared to Cu filter. Moreover, Mo filter showed higher transmission dose by around 1.5 times than that of Cu filter. In image assessment, it was found that W was unsuitable to be used as a filter, whereas Mo could be used as a filter to reduce dose without decline in image quality at the tube voltage of 80 kVp or higher. As tube voltage increased, 2.0 mm Al+0.1 mm Mo almost had a similar histogram width to that of 2.0 mm Al+0.2 mm Cu. Therefore, Mo filter can be used at relatively high tube voltage of 80 kVp, 100 kVp and 120 kVp. The SNR of 2.0 mm Al+0.1 mm Mo did not show any significant difference from those of 2.0 mm Al+0.2 mm Cu and 2.0 mm Al+0.1 mm Cu. As a result, if Mo filter is used to replace Cu filter in general radiography, where 80 kVp or higher is used for digital radiation image, patient exposure dose can be reduced significantly without decline in image quality, compared to Cu filter. Therefore, it is believed that Mo filter can be applied to chest X-ray and high tube voltage X-ray in actual clinical practice.