A Study on Distance Relay of Transmission with UPFC Using Artificial Neural Network (신경회로망을 이용한 UPFC가 연계된 송전선로의 거리계전기에 관한 연구)

  • Park, Jeong-Ho;Jung, Chang-Ho;Shin, Dong-Joon;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.196-198
    • /
    • 2002
  • This paper represents a new approach for the protective relay of power transmission lines using a Artificial Neural Network(ANN). A different fault on transmission lines need to be detected, classified and located accurately and cleared as fast as possible. However, The protection range of the distance relay is always designed on the basis of fixed settings, and unfortunately these approach do not have the ability to adapt dynamically to the system operating condition. ANN is suitable for the adaptive relaying and the detection of complex faults. The backpropagation algorithm based multi-layer perceptron is utilized for the learning process. It allows to make control to various protection functions. As expected, the simulation result demonstrate that this approach is useful and satisfactory.

  • PDF

Wavelet-Based Digital Watermarking Method (웨이브릿 기반 디지털 워터마킹 방법)

  • 이경훈
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.7
    • /
    • pp.871-880
    • /
    • 2002
  • In this paper, I proposed the adaptive watermarking based on the discrete wavelet transform for the very robust watermarking against intentional distortion which attacks on image. A watermark is an binary image such as document(sign), and such watermark image is embedded in the LH and HL band of wavelet transformed domain for copyright protection of image data. To evaluate robustness of the proposed method, we applied some basic algorithm of image processing such as brightening, darkening, sharpening, blurring, cropping, histogram equalizing and lossy compression(JPEG, gif). As a result of experiment, the proposed method has the good image quality and the high perceptibility of watermark. It was demonstrated by experiments that the proposed algorithm can provide an excellent protection under various attacks.

  • PDF

A Study on Adaptive Information Hiding Technique for Copyright Protection of Digital Images (디지털 영상물의 저작권 보호를 위한 적응적 정보 은닉 기술에 관한 연구)

  • Park, Kang-Seo;Chung, Tae-Yun;Oh, Sang-Rok;Park, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2427-2429
    • /
    • 1998
  • Digital watermarking is the techinque which embeds the invisible signal into multimedia data such as audio, video, images, for copyright protection, including owner identification and copy control information. This paper proposes a new watermark embedding and extraction technique by extending the direct sequence spread spectrum technique. The proposed technique approximates the frequency component of pixels in spatial domain by using Laplacian mask and adaptively embeds the watermark considering the HVS to reduce the degradation of Image. In watermark extraction process, the proposed technique strengthens the high frequency components of image and extracts the watermark by demodulation. All this processes are performed in spatial domain to reduce the processing time.

  • PDF

Fault Detection Relaying for Transmission line Protection using ANFIS (적응형 퍼지 시스템에 의한 송전선로보호의 고장검출 계전기법)

  • 전병준
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.9 no.5
    • /
    • pp.538-544
    • /
    • 1999
  • In this paper, we propose a new fault detection algorithm for transmission line protection using ANFIS(Adaptive Network Fuzzy Inference System). The developed system consists of two subsystems: fault type classification, and fault location estimation. We use rms value, zero sequence component and positive sequence of current, and then using learning method of neural network, premise and consequent parameters are tuned properly. To prove the performance of the proposcd system, generated data by EMTP(Electr0- Magnetic Transient Program) sin~ulationi s used. It is shown that the proposed relaying classifies fault types accurately and advances fault location estimation.

  • PDF

A Study on Protection system to the Load Characteristics on the AC Feeder System (부하 특성에 따른 교류 급전시스템에서의 보호방식 연구)

  • Jung Ho-Sung;Han Moon-Seob;Lee Chang-Mu;Kim joorak
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1370-1372
    • /
    • 2004
  • At present. distance relay and ${\Delta}I$ current increment relay are used as primary and secondary protection in the AC feeder system. However. electric railway vehicles according to power electronic's development had developed resistance control, thyristor phase control and PWM control system. and operation of train is increasing in a feeder section. Therefore this paper analyzes the load characteristics and situation of relay's maloperation caused by load current increase, harmonics, regenerative braking current and operation of the different vehicles in same feeder section. Based on this analysis. this paper proposes consideration items for relay correction and advanced adaptive relay that can change operation area according to load current.

  • PDF

Fuzzy Techniques in Optimal Bit Allocation

  • Kong, Seong-Gon
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.1313-1316
    • /
    • 1993
  • This paper presents a fuzzy system that estimates the optimal bit allocation matrices for the spatially active subimage classes of adaptive transform image coding in noisy channels. Transform image coding is good for image data compression but it requires a transmission error protection scheme to maintain the performance since the channel noise degrades its performance. The fuzzy system provides a simple way of estimating the bit allocation matrices from the optimal bit map computed by the method of minimizing the mean square error between the transform coefficients of the original and the reconstructed images.

  • PDF

A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance (2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구)

  • 이원석;정창호;김진오
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.4
    • /
    • pp.221-226
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.

A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance (2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구)

  • 이원석;정창호;김진오
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.4
    • /
    • pp.221-221
    • /
    • 2004
  • Power system has recently used Double-circuit Line and Multi-circuit Line in the industrial development. This has an advantage of system stability and reliability, but the complexity of the system has a disadvantage that makes it difficult to protect the power line. Double-circuit Line has two operation conditions in the Single-circuit operation and Double-circuit operation, so it has mutual impedance. To make it possible for the remaining single-line to operate independently while there is a fault with first line or when maintenance is needed, a trip region for the single-circuit operation should be set in order to set the relay trip region. An optimal trip region for each operation, a different operational conditions for the relay setting should be calculated. In this paper, trip regions of each operation condition have been compared by considering mutual impedance and fault resistance that led to the calculation of fault impedance. Also, as we know that one of the advantages in the distance relay is the back-up protection, we calculated the trip region(Zone-2) in consideration of the mutual impedance.

An Unequal Protection FEC Scheme for Video over Optical Access Networks

  • Cao, Yingying;Chen, Xue;Wang, Liqian;Li, Xicong
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.6
    • /
    • pp.1463-1479
    • /
    • 2013
  • In this paper, we propose an unequal protection physical coding sub-layer (PCS) forward error correction (FEC) scheme for efficient and high-quality transmission of video data over optical access networks. Through identifying and resolving the unequal importance of different video frames and passing this importance information from MAC-layer to PCS, FEC scheme of PCS can be adaptive to application-layer data. Meanwhile, we jointly consider the different channel situations of optical network unit (ONU) and improve the efficiency of FEC redundancy by channel adaptation. We develop a theoretical algorithm and a hardware method to achieve efficient FEC assignment for the proposed unequal protection scheme. The theoretical FEC assignment algorithm is to obtain the optimal FEC redundancy allocation vector that results in the optimum performance index, namely frame error rate, based on the identified differential importance and channel situations. The hardware method aims at providing a realistic technical path with negligible hardware cost increment compared with the traditional FEC scheme. From the simulation results, the proposed Channel and Application-layer data Adaptation Unequal Protection (CAAUP) FEC scheme along with the FEC ratio assignment algorithm and the hardware method illustrates the ability of efficient and high-quality transmission of video data against the random errors in the channel of optical access networks.

The Fourth Industrial Revolution and Social Cohesion: Longitudinal Analysis for OECD Countries(2006-2015) (4차 산업혁명과 사회통합: OECD 회원국 종단분석(2006-2015))

  • Song, Jeong An
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.298-305
    • /
    • 2018
  • This paper explored the impact of adaptive efforts for the 4th Industrial Revolution(hereafter, 4IR) on social cohesion at national level. To examine this relationship, Latent Growth Model was applied to thirty one OECD membership countries, 2006-2015. Adaptive efforts for 4IR was measured by the 4IR Relative Readiness(WEF, 2016) and social cohesion was measured by Corruption Perception Index(Transparency International) and trust on politicians(WEF). Results showed that corruption perception significantly decreased by the 4IR Relative Readiness and legal protection(judiciary independency and corporate ethics) and trust on politicians significantly increased by judiciary independency. These results imply that public and corporate efforts for the 4IR does not necessarily have negative impact on social cohesion as long as legal protection such as judiciary independency and corporate ethics are equally pursuit at national level.