• Title/Summary/Keyword: Actual Test

Search Result 3,540, Processing Time 0.03 seconds

An Estimation of the Efficiency and Satisfaction for EEG Practice Using the Training 10-20 Electrode System: A Questionnaire Survey (연습용 10-20 Electrode System을 이용한 뇌파검사 실습의 효율성과 만족도 평가)

  • Lee, Chang Hee;Kim, Dae Jin;Choi, Jeong Su;Lee, Jong-Woo;Lee, Min Woo;Cho, Jae Wook;Kim, Suhng Wook
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.3
    • /
    • pp.300-307
    • /
    • 2017
  • Electroencephalography (EEG) is distinct from other medical imaging tests in that it is a functional test that helps to diagnosis disorders related to the brain, such as epilepsy. The most important abilities for a medical technologist when performing an EEG are knowing the exact location of the electrode and recording the EEG wave clearly, except for artifacts. Although theoretical education and practical training are both included in the curriculum for improving these abilities, sufficient practical training has been lacking due to problems like expensive equipment and insufficient practical training time. We try to solve these issues by manufacturing the training 10-20 electrode system and by estimating the efficiency and satisfaction of the training 10-20 electrode system through a questionnaire. The time required for practical training using this system was $43.58{\pm}9.647min$, which proved to be efficient. The satisfaction score of participants who experienced curriculum practical training was improved from $7.21{\pm}2.285$ to $9.46{\pm}1.166$. Based on these findings, it is considered that practical training via the use of the training 10-20 electrode system will solve the problems, such as lack of equipment and insufficient practical training time. Nonetheless, to further improve the training 10-20 electrode system, it must overcome the limitations of developing a device capable of checking the actual brain waves and validating the exact location of electrode attachment.

The influences of individual personality types on ERP system's acceptance: a preliminary test (개인의 성격유형이 ERP수용에 미치는 영향에 관한 탐색적 연구)

  • Kim, Hyun-Sang;Lee, Jang-Hyung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.4
    • /
    • pp.47-65
    • /
    • 2006
  • The application of the ERP system is becoming more common to the businesses since a firm needs to reinforce positive competitiveness and to maintain competitive advantage. The ERP system is an enterprise integration solution that converts the whole business processes through information technology. Extant research provides plenty of results about the success factors of the ERP system; however, most of the researches focus on the exterior factors such as techniques rather than on the influences that a firm's employees' individual personality has in accepting the information technology of the ERP system. The objective of this study is to investigate the role of the employees' individual personality as a factor that makes the ERP system a success. The surveys--composed of the extent of information technology acceptance about the personality type of MBTI (Myers-Briggs type indicator) and the ERP system--were given to the companies applying the ERP system The personality type of MBTI is measured by 4 types of Myers, and Davis's TAM (technology acceptance model) is used for the information technology acceptance. The results of this study are summarized as follows. First the extraversion and the judging in the personality types of MBTI have a significant influence on the information technology acceptance of the ERP system. However, the thinking and the feeling in the personality types of MBTI were analyzed to not have a critical affect on the ERP system acceptance. Second as verified in the extant research the information technology acceptance verification related to the ERP system has a significant influence on perceived ease of use, perceived usefulness, behavioral intention and actual usage of the ERP system. The results of this study can be used for a successful application of the ERP system as follows. First it offers foundation of perception that the type of the individual personality is a significant key figure for the successful use of the ERP system. Second it provides a basis for the knowledge of combining the model of information technology acceptance and the psychological factors.

  • PDF

A Study on the Utilization of Information and Communication Assistive Devices for Bridging the Digital Divide of the Disabled (장애인 정보격차 해소를 위한 정보통신 보조기기 활용방안 연구)

  • Kim, Jung-Ho;Suh, Jun-Kyo Francis;Koo, Jun
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.581-596
    • /
    • 2010
  • The purposes of this study are to investigate and analyze the level of information and the state of digital divide of the disabled by surveying the demand for information and communication assistive devices, and to provide basic data for plans on the development and utilization of information and communication assistive devices. In order to understand the actual condition and the state of digital divide of persons with disabilities, the differences of possession and accessibility of information technology devices, usage ability, and utilization were analyzed according to the disability profile by using the T-test. The results show that there are significant differences (T=-2.510*) of possession and accessibility of information technology devices with respect to the disability profile, and that the disabled have lower possession and accessibility of devices than the non-disabled. Result of this study's demand forecast shows that about 28% of total respondents are currently using information and communication assistive devices, and a majority (67%) of them answered that the use of assistive devices lend great help to their lives. The proportion of those who have been supported by the government or related organizations with information and communication assistive devices were 36% of the total respondents, and those satisfied with the performance of the devices were 46% of the total responses. Meanwhile, only 36% of total users answered that the operation and use of functions of the devices was easy and convenient, responding that the difficulty of operating assistive devices was the greatest inconvenience. Moreover, the general requests of respondents in regards to the devices were stabilization of device performance, miniaturization of size, simplification of buttons, and reduction of weight.

  • PDF

Image Quality Assessment Model of Natural Scene Based on Normal Distribution Analysis (일반 장면의 정규분포 분석을 기반으로 한 화질 측정 모형)

  • Park, Hyung-Ju;Har, Dong-Hwan
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.373-386
    • /
    • 2013
  • In this research, we specify the image consumers' preferred image quality ranges based on objective image quality evaluation factors and follow a method which measures preference of the natural image scenes. In other words, according to No-Reference, we select dynamic range, color, and contrast as factors of image quality measurements. For collecting sample images, we choose the preferred 200 landscapes which have over 30 recommendations by image consumers on the internet photo gallery. According to the scores of three objective factors of image quality measurements, the final expected score which means the image quality preference is measured and its total score is 100 points. In the main test, the actual image sample shows dynamic range 10 stop, LAB mean value L:54.7, A:2.96, B:-15.84, and RSC contrast 376.9. Total 200 image samples' normal distribution z value represents in dynamic range 0.21, LAB mean value L:0.15, A:0.38, B:0.13, and RSC contrast 0.08. In the standard normal distribution table, we can convert the z value as a percentage; dynamic range is 8.32%, LAB mean value is L:5.96%, A:14.8%, B:5.17%, and RSC contrast is 3.19%. And then, we convert the percentage values into the scores of 100; dynamic range is 91.68, LAB mean value is 91.36, and RSC contrast is 96.81. Therefore, we can conclude that the sample image's total mean score is 94.99 based on three objective image quality factors. Throughout our proposed image quality assessment model, we can measure the preference value of natural scenes. Also, we can specify the preferred image quality representation ranges and measure the expected image quality preference.

  • PDF

Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor (판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발)

  • Kim, Hoe Woong;Kim, Sang Hwal;Han, Jae Won;Joo, Young Sang;Park, Chang Gyu;Kim, Jong Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.48-57
    • /
    • 2015
  • In a sodium-cooled fast reactor, which is a Generation-IV reactor, refueling is conducted by rotating, but not opening, the reactor head to prevent a reaction between the sodium, water and air. Therefore, an inspection technique that checks for the presence of any obstacles between the reactor core and the upper internal structure, which could disturb the rotation of the reactor head, is essential prior to the refueling of a sodium-cooled fast reactor. To this end, an ultrasound-based inspection technique should be employed because the opacity of the sodium prevents conventional optical inspection techniques from being applied to the monitoring of obstacles. In this study, a ranging inspection technique using a plate-type ultrasonic waveguide sensor was developed to monitor the presence of any obstacles between the reactor core and the upper internal structure in the opaque sodium. Because the waveguide sensor installs an ultrasonic transducer in a relatively cold region and transmits the ultrasonic waves into the hot radioactive liquid sodium through a long waveguide, it offers better reliability and is less susceptible to thermal or radiation damage. A 10 m horizontal beam waveguide sensor capable of radiating an ultrasonic wave horizontally was developed, and beam profile measurements and basic experiments were carried out to investigate the characteristics of the developed sensor. The beam width and propagation distance of the ultrasonic wave radiated from the sensor were assessed based on the experimental results. Finally, a feasibility test using cylindrical targets (corresponding to the shape of possible obstacles) was also conducted to evaluate the applicability of the developed ranging inspection technique to actual applications.

A Study on Development of Prototype Test Train Design in G7 Project for High Speed Railway Technology (G7 고속전철기술개발사업에서의 시제차량 통합 디자인 개발)

  • 정경렬;이병종;윤세균
    • Archives of design research
    • /
    • v.16 no.4
    • /
    • pp.185-196
    • /
    • 2003
  • The demand for an environment-friendly transportation system, equipped with low energy consumption, and low-or zero-pollution has been on the increase since the beginning of the World Trade Organization era. Simultaneously, the consistent growth of high-speed tram technology, combined with market share, has sparked a fierce competition among technologically-advanced countries like France, Germany, and Japan in an effort to keep the lead in high-speed train technology via extensive Research and development(R&D) expenses. These countries are leaders in the race to implement the next-generation transportation system, build intercontinental rail way networks and export the high-speed train as a major industry commodity. The need to develop our own(Korean) 'high-speed train' technology and its core system technology layouts including original technology serves a few objectives: They boost the national competitive edge; they develop an environmental friendly rail road system that can cope with globalization and minimize the social and economic losses created by the growing traffic-congested delivery costs, environment pollution, and public discomforts. In turn, the 'G7 Project-Development of High Speed Railway Technology' held between 1996 and 2002 for a six-year period was focused on designing a domestic train capable of traveling at a speed of 350km/h combined and led to the actual implementation of engineering and producing the '2000 high-speed train:' This paper summarizes and introduces one of the G7 Projects-specifically, the design segment achievement within the development of train system engineering technology. It is true that the design aspect of the Korean domestic railway system program as a whole was lacking when compared with the advanced railroad countries whose early phase of train design emphasized the design aspect. However, having allowed the active participation of expert designers in the early phase of train design in the current project has led to a new era of domestic train development and the implementation of a way to meet demand flexibly with newly designed trains. The idea of a high-speed train in Korea and its design concept is well-conceived: a faster, more pleasant, and silent based Korean high-speed train that facilitates a new travel culture. A Korean-type of high-speed train is acknowledged by passengers who travel in such trains. The Korean high-speed prototype train has been born, combining aerodynamic air-cushioned design, which is the embodiment of Korean original design of forehead of power car minimized aerodynamic resistance using a curved car body profile, and the improvement of the interior design with ergonomics and the accommodation of the vestibule area through the study of passenger behavior and social culture that is based on the general passenger car.

  • PDF

A study on accuracy and application of the implant torque controller used in dental clinic (임상에서 사용하고 있는 임플란트 토크조절기의 정확도와 적용에 관한 사용실태)

  • Joo, Young-Hun;Lee, Jin-Han
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.197-205
    • /
    • 2011
  • Purpose: This study was to evaluate the accuracy of the implant torque controller used in dental clinics and to investigate whether it was applied appropriately. Materials and methods: Fifty dentists who work in dental clinics were enrolled in this study. Dental (implant) practice career, experience frequency of implant screw loosening and fracture, education of implant torque controller application and infection control methods were included in the survey. 25 Ncm and 30 Ncm of the tightening torque applied to the implant screw were measured by 50 clinicians. After measuring the torque value by using the torque controller, the torque mean according to where education about the implant torque controller was received was analyzed with independent t-test at the significance level of 0.05. Results: The torque controller used in private dental clinics showed 4.78% error ratio. When 50 dentists applied 25 Ncm to the implant screw was $29.0{\pm}8.4$ Ncm, and that in 30 Ncm was $34.3{\pm}9.1$ Ncm. Statistical significance was found between the group that was educated about implant torque application and the group that was not educated. Conclusion: During the prosthodontic treatment with implant, there was difference between actual applied torsion force and the amount torque controller indicated. Clinicians have to not only be well-informed about the accurate usage method of the torque controller, but also keep and manage the torque controller so as to maintain continuous and accurate torque values. Through this, it is considered to achieve clinical results to minimize problems of screw loosening or fracture.

Effective Customer Risk Management at the Nuclear Medicine Department: Risk Managemont MOT Development Application and Producing Public Relations Film (핵의학과 내에서의 효과적인 고객위험관리: 위험관리 응대 MOT 개발적용 및 홍보동영상 제작)

  • Ham, Jong-Hum;Hwang, Jae-Bong;Kim, Joon-Ho;Lee, Gui-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.110-122
    • /
    • 2009
  • Purpose: Nowadays, A medical institution assesment could get more interest about a quality of medical services from many hospitals that developed the active activities for improving medical services. Also, there is an other additional issue which is the patients risk management. Uijeongbu ST. Mary's hospital Nuclear Medicine department has been changed many work process after PET-CT introduction and renovation of its place since 2008. Therefore, modified structure and the way of existing work process have contained risk factors. The purpose of this study would be the appropriate risk management process while imaging examination process, the removal risk factors and improved activities through the analysis risk factors. Materials and Methods: Nuclear Medicine department new process should analysis through many-sided, Firstly, make and trained risk management manual after then apply an actual work. Result analysis showed the number of risk accident occurrence that comparing the last year and after the improved activities. Secondly, producing risk management public relations film has been showed an applicable patient after then the customer service measurement checked for a hundred patient by questionnaire. Lastly, Risk factors were eliminated through the facilities participation improving activities which could change for the better risk factors. Results: The number of safety accident occurrence(medication error, fall and collision) were checked as zero after the improving activities both PET-CT and gamma camera examination. The results of questionnaire showed as follows; 74% marked as understanding of the test process and 81% checked "satisfaction" after the public relations film showing. The question "Did you consider about the risk factors?", both PET-CT and gamma camera checked as 94% and 89% respectively. Customer risk management could be accomplished effectively through the improving activities at the nuclear medicine department. Conclusions: The study would be an opportunity that spread risk factors were systematically showed and analyzied. Also, It showed the possibility of the minimized safety accident and its feedback, if application of the response manuel that could be a standard of radiology technician's work method to react safety accident. It was the more effective that visual material could be easy to approach as a methodology of risk factors. As far as I have concerned that It could help the safety and convenience through continuous and detailed activities that offer to patients.

  • PDF

On-line Quality Assurance of Linear Accelerator with Electronic Portal Imaging System (전자포탈영상장치(EPID)를 이용한 선형가속기의 기하학적 QC/QA System)

  • Lee, Seok;Jang, Hye-Sook;Choi, Eun-Kyung;Kwon, Soo-Il;Lee, Byung-Yong
    • Progress in Medical Physics
    • /
    • v.9 no.3
    • /
    • pp.127-136
    • /
    • 1998
  • On-line geometrical quality assurance system has been developed using electronic portal imaging system(OQuE). EPID system is networked into Pentium PC in order to transmit the acquisited images to analysis PC. Geometrical QA parameters, including light-radiation field congruence, collimator rotation axis, and gantry rotation axis can be easily analyzed with the help of graphic user interface(GUI) software. Equipped with the EPID (Portal Vision, Varian, USA), geometrical quality assurance of a linear accelerator (CL/2100/CD, Varian, USA), which is networked into OQuE, was performed to evaluate this system. Light-radiation field congruence tests by center of gravity analysis shows 0.2~0.3mm differences for various field sizes. Collimator (or Gantry) rotation axis for various angles could be obtained by superposing 4 shots of angles. The radius of collimator rotation axis is measured to 0.2mm for upper jaw collimator, and 0.1mm for lower jaw. Acquisited images for various gantry angles were rotated according to the gantry angle and actual center of image point obtained from collimator axis test. The rotated images are superpositioned and analyzed as the same method as collimator rotation axis. The radius of gantry rotation axis is calculated 0.3mm for anterior/posterior direction (gantry 0$^{\circ}$ and 170$^{\circ}$) and 0.7mm for right/left direction(gantry 90$^{\circ}$ and 260$^{\circ}$). Image acquisition for data analysis is faster than conventional method and the results turn out to be excellent for the development goal and accurate within a milimeter range. The OQuE system is proven to be a good tool for the geometrical quality assurance of linear accelerator using EPID.

  • PDF

Analysis of the Factors Affecting Anaerobic Thermophilic Digestibility of Food Wastes (음식물쓰레기의 고온 혐기성 소화도에 미치는 요소에 대한 분석)

  • Kim, Do Hee;Hyun, Seung Hoon;Kim, Kyung Woong;Cho, Jaeweon;Kim, In S.
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.8 no.2
    • /
    • pp.130-139
    • /
    • 2000
  • Serial basic tests were conducted for the determination of fundamental kinetics and for the actual application of kinetic parameter to food waste digestion with precise measurement of methane production under a thermophilic condition. The effects of food particle size, sodium ion concentration, and volatile solid (VS) loading rate on the anaerobic thermophilic food waste digestion process were investigated. Results of serial test for the determination of fundamental kinetic coefficients showed the value of k (maximum substrate utilization rate coefficient) and KS (half-saturation coefficient) as $0.24hr^{-1}$ and $700mg/{\ell}$, respectively, for non-inhibiting organic loading range. No inhibition effect was shown until $5g/{\ell}$ of sodium ion concentration was applied to a serum bottle reactor. However, the volume of methane gas was decreased gradually when the concentrations of more than $5g/{\ell}$ of sodium ion applied. All sizes of food waste particle showed the same constants (A : 0.45) but the maximum substrate utilization rate constant ($k_{HA}$) was inversely proportional to particle size. As an average particle size increased from 1.02 mm to 2.14 mm, $k_{HA}$ decreased from $0.0033hr^{-1}$ to $0.0015hr^{-1}$. The result reveals that particle size is one of the most important factors in anaerobic food waste digestion. There was no inhibition effect of sodium ion when VS loading rate was $30g/{\ell}$. And maximum injection concentration of VS loading rate was determined about $40g/{\ell}$.

  • PDF