Effect of the size of active device and heatsink of power MOSFETs on its the junction to ambient transient thermal behavior

  • Koh, Jeong-Wook;An, Chul
    • Proceedings of the IEEK Conference
    • /
    • 2000.11b
    • /
    • pp.241-244
    • /
    • 2000
  • To investigate the compact effect of the different area of an active layer and the different type of heatsink on the junction to ambient transient thermal impedance, we have characterized the thermal behavior of power MOSFETs that have three different areas of an active layer and two types of heatsink. To do so, the "cooling curve method" has been used in order to measure the junction-to-ambient transient thermal impedance Zthja that represents the thermal behavior of the devices. The measured data depiets that the larger area of an active layer gives the better-in other words. smaller-thermal impedance, and that the larger size of a heatsink improves the thermal impedance.

  • PDF

A Study on the Vehicle Digital Broadcasting System of Active Electronic Control Method using Phase Shifter (위상변위기를 이용한 능동전자제어방식의 차량용 디지털 위성방송 시스템에 관한 연구)

  • 김기열;이상호;박종국
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.7
    • /
    • pp.903-908
    • /
    • 1999
  • In this paper, it is proposed the phase shifter array active system to receive digital satellite broadcasting for vehicle. To receive satellite broadcasting data in vehicle, it is inevitable to have active antenna system, which traces the satellite in real time. Also if it is used in vehicle, it must be thin and light structure. To develop this type of antenna system, several techniques should be integrated properly. These are the design and manufacturing technique of high gain antenna, algorithm for tracking satellite and its manufacturing technique, controller design and manufacturing technique, system integration technique and so on. The validity of the proposed AVDBS system was confirmed by simulation and experimental results.

  • PDF

Design of an Asymmetrical Three-phase Inverter for Load Balancing and Power Factor Correction Based on Power Analysis

  • Mokhtari, M.;Golshannavaz, S.;Nazarpour, D.;Aminifar, F.
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.293-301
    • /
    • 2011
  • This paper presents a novel theoretical method based on power analysis to obtain voltage reference values for an inverter-based compensator. This type of compensator, which is installed in parallel with the load, is usually referred to as the active filter. The proposed method is tailored to design the compensator in such a way that it can simultaneously balance the asymmetric load, as well as correct the power factor of the supply side. For clarity, a static compensator is first considered and a recursive algorithm is utilized to calculate the reactance values. The algorithm is then extended to calculate voltage reference values when the compensator is inverter based. It is evident that the compensator would be asymmetric since the load is unbalanced. The salient feature associated with the proposed method is that the circuit representation of system load is not required and that the load is recognized just by its active and reactive consumptions. Hence, the type and connection of load do not matter. The validity and performance of the new approach are analyzed via a numerical example, and the obtained results are thoroughly discussed.

A Study on the Prefilter to Protect Overshoot of Active Magnetic Bearing using Integral Type LQR-design Method (적분형 LQR 설계 기법을 이용한 능동자기베어링의 오버슈트 방지용 입력필터에 관한 연구)

  • Kang, Seong-Gu;Lee, Kee-Seok;Chung, Jun-Mo;Shin, Woo-Cheol;Hong, Jun-Hee
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.2
    • /
    • pp.1-7
    • /
    • 2007
  • Active magnetic bearing has been adopted to support the rotor by electomagnetic force without mechanical contact and lubrication process. A property of the control system for magnetic bearing is improved in accordance with making higher system gain. If the control system has integral part, an excessive overshoot response is shown by making higher integral gain. Therefore, this paper suggests a PID control system in order to eliminate the overshoot at the first stage and improve response characteristics to an impact disturbance at the status of levitation. The control gain was obtained by LQR design method which has the structure of I-PD control system in the state space. The PID control system containing prefilter has the same structure as the I-PD control system. Therefore, the PID control system adopted is able to be tuned by LQR design method. Finally, this paper shows the effect of the prefilter on the active magnetic bearing system through response experiments for levitation responses.

Effect of Sa-am Acupuncture Method for Chronic Tension-type Headache;A Randomized Controlled Trial (만성 긴장성 두통 환자에 대한 사암침 치료효과의 Pilot 임상연구)

  • Hong, Kwon-Eui;Park, Yang-Chun;Jo, Jeong-Hyo;Jo, Hyun-Gyeong;Jeong, In-Cheol;Kang, Wee-Chang;Lee, Sang-Bong;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.24 no.1
    • /
    • pp.13-28
    • /
    • 2007
  • Objectives : Clinical character of chronic tension-type headache is bilateral, moderate intensity, persistent and chronic, repeating disease and CTTH is a common prevalent disease, but pathophysiology and likely mechanism remain unclear. It impedes subjective quality of life. The purpose of this research is to examine the effect of sa-am acupuncture method for chronic tension-type headache. Methods : In this randomized, single blind, placebo-controlled study, we compared active acupuncture with sham acupuncture for the treatment of chronic tension-type headache. Volunteers who satisfied the requirements were enrolled in study. Evaluation of chronic tension-type headache was measured by VAS and Headache Disability Inventory(HDI), Six point Linkert Scale before and after treatments. Results : 26 subjects finished study. There were not difference between two groups on age, sex, weight, height, blood pressure, pulse, respiratory rate, Byeonjeung, sunrise of treatment. In change of VAS, there were not difference between two groups on before treatment. Before treatment per visit, VAS of 6th and 7th visit were significantly decreased in active acupuncture(each p=0.039, p=0.008) and were not decreased in sham acupuncture. In change of VAS on a withdrawing needling after treatment, VAS of 1st, 2nd, 6th and 7th visit were significantly decreased in active acupuncture (each p=0.001, 0.038, 0.035, 0.008) and VAS of 2nd, 4th and 5th, 6th visit were significantly decreased in sham acupuncture(each p=0.033, 0.032, 0.035, 0.031). In change of VAS on 2hrs after treatment, VAS of 4th and 5th, 6th visit were significantly decreased in active acupuncture(each p=0.014, 0.023, 0.027) and 5th visit were significantly decreased in sham acupuncture(each p=0.004, 0.009). In change of VAS on 4hrs after treatment, VAS of 4th and 5th, 6th visit were significantly decreased in active acupuncture(each p=0.018, 0.011, 0.015) and 5th, 6th visit were significantly decreased in sham acupuncture(each p=0.020, 0.015). In change of VAS on the next day after treatment, VAS of 3th and 4th and 5th, 6th visit were significantly decreased in active acupuncture(each p=0.032, 0.011, 0.005, 0.012) and 4th, 5th visit were significantly decreased in sham acupuncture(each p=0.001, 0.012). In change of VAS according to a current time(before treatment, after a withdrawing needling, 2hrs, 4hrs, the next day), total score of VAS was decreased more active acupuncture group than sham acupuncture group, but there were no statistical significance compared with sham acupuncture group. In change of HDI score, after treatment was decreased than before treatment in two group, but there were no statistical significance compared with two group. In change of Six point Linkert scale score, after treatment was decreased than before treatment in two group on 6th, 7th visit(active acupuncture 6th 7th each p=0.002, 0.003, sham acupuncture 6th 7th each 0.003, 0.009), but there were no statistical significance compared with tow group. Conclusion : Sa-am acupuncture treatment is effective to improve the symptoms and quality of life in patients with chronic tension-type headache.

  • PDF

Types of Nurse's Attitudes Toward the Aging Process A Q-Methodological Approach (늙어감에 대한 간호사의 태도 - Q 방법론적 접근 -)

  • Jo, Kae-Hwa;An, Gyeong-Ju
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.6
    • /
    • pp.823-834
    • /
    • 2007
  • Purpose: The purpose of this study was to analyze types of nurse's attitudes toward the aging process. Methods: A Q-methodology which provides a method of analyzing the subjectivity of each item was used. Thirty-four selected Q-statements from each of 38 subjects were classified into a shape of normal distribution using a 9 point scale. The collected data was analyzed using a QUANL PC program. Results: Five types of attitudes towards the aging process from research subjects in Korean nurses were identified. Type I is a positive acceptance type, Type II is a negative acceptance type, Type III is a passive coping type, Type IV is an active coping type, and Type V is an ambiguous acceptance type. Conclusion: The results of the study indicate that different approaches of educational programs for elderly care are recommended based on the five types of nurse's attitude toward the aging process.

A study on the subjectivity of college students' participation in media education

  • Lee, Jei-Young;Park, Chang-Woo;Kim, Ji-Eun
    • International Journal of Contents
    • /
    • v.7 no.2
    • /
    • pp.42-48
    • /
    • 2011
  • The aim of this study is to investigate college students' opinion on participation in media education. The research question is as follows: first, what is the college students' perceptions who participated in media education? Second, what are the differences among the perceptions of college students who participated in media education? To answer these research questions, we used Q-methodology, which is more useful in organizing subjectivity types and opinions of students, both in explaining and sorting of data by characteristic and personal opinion. As a result, two types were found; type 1 is the active participation type that focuses on the active participation in media education as a productive tool and teaching method, as well as diminishing the current controls and restrictions on its use in education. On the other hand, type 2 is the growing adaptive type and is positive for the future development of media education in a transitional role, while they think that current media education for college students is not qualitative yet, a productive tool and the quality of the information message is lacking, and so on.

Optimal position selection of sensors and transducers for noise control of 3D (3차원 공간의 소음 제어를 위한 센서 및 트랜스듀서 최적위치 선정)

  • Lee, Hong-Won;Seo, Sung-Dae;Nam, Hyun-Do
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.107-110
    • /
    • 2003
  • In this paper, the optimal position selection of error sensors and transducers to attenuate interior noise from outside noise sources using active control techniques is presented. To get an optimal control characteristics in adaptive noise control systems, it is necessary to optimize the positions of sensors and transducers. A new type of simulated annealing method has been proposed as searching technique to find optimal transducers and sensors positions in which the sum of the squared pressures at sensor position in an enclosure can be best minimized. Computer simulations and experiments have been performed to show the effectiveness of the proposed method.

  • PDF

Active assembly Method Using a Two-Arm Robot System in Highly Uncertain Environment (불확실한 환경에서 두 팔 로봇을 이용한 능동적 조립 방법)

  • 정성엽;강경대;이두용
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.73-73
    • /
    • 2000
  • Assembly is usually performed by one robot and fixtures. This type of assembly system has Low flexibility in terms of variety of parts and part-presentation that the system can handle. This paper addresses assembly without fixtures using two-manipulator robot. An active method using force feedback is proposed for the peg-in-hole assembly in highly uncertain environment. Assembly states are described by extended contact relations. Qualitative templates for events are easily derived from the token vector of the Petrinet model. The states are recognized through identification of the events using two 6-d.o.f force/moment sensors. The proposed method is verified and evaluated through experiments with round peg- in-hole assembly.

  • PDF

The Study of PFC Converter added Active DC Filter Using for the Predict Current Control Method (예측 전류 제어기법을 사용한 능동 DC 필터 부가형 PFC 컨버터에 관한 연구)

  • Park S.W.;Heo T.W.;Shin D.R.;Bae J.I.;Ahn I.M.;Woo J.I.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.219-222
    • /
    • 2001
  • In this paper, we firstly proposed to the boost type PFC circuit for a power factor improving and a harmonic decreasing. The predict current control method is used to control these PFC circuit. This current control method has a merit that is possible to improve power factor and harmonics. In addition, we suggested to the active DC filter, which is connected with the DC output terminal, in order to compensate the DC ripple components. Consequently, these results are proved by the simulation tool, PSIM, which is an exclusive simulator of power electronics.

  • PDF