• Title/Summary/Keyword: Active rectifier

Search Result 219, Processing Time 0.026 seconds

An Injection-Locked Based Voltage Boost-up Rectifier for Wireless RF Power Harvesting Applications

  • Lee, Ji-Hoon;Jung, Won-Jae;Park, Jun-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.6
    • /
    • pp.2441-2446
    • /
    • 2018
  • This paper presents a radio frequency-to-direct current (RF-to-DC) converter for special RF power harvesting application at 915 MHz. The major featured components of the proposed RF-to-DC converter is the combination of a cross-coupled rectifier and an active diode: first, the cross-coupled rectifier boosts the input voltage to desired level, and an active diode blocks the reverse current, respectively. A prototype was implemented using $0.18{\mu}m$ CMOS technology, and the performance was proven from the fact that the targeted RF harvesting system's full-operation with higher power efficiency; even if the system's input power gets lower (e.g., from nominal 0 to min. -12 dBm), the proposed RF-to-DC converter constantly provides 1.47 V, which is exactly the voltage level to drive follow up system components like DC-to-DC converter and so on. And, maximum power conversion efficiency is 82 % calculated from the 0 dBm input power, 2.3 mA load current.

Current Control for an AFE Rectifier Using Space Vector PWM (공간벡터변조방식에 의한 AFE정류기의 전류제어)

  • Jeon, Cheol-Hwan;Hur, Jae-Jung;Yoon, Kyoung-Kuk;Yoo, Heui-Han;Kim, Sung-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.4
    • /
    • pp.498-503
    • /
    • 2019
  • Electric propulsion ships are gaining widespread interest in the marine industry owing to extreme air pollution concerns. Consequently, several studies are actively being conducted for improving the power quality. Various methods have been developed that incorporate passive filters, notch filters, and active filters for reducing the harmonic content in the input current of a conventional diode front end rectifier. Among such filters, the active front end (AFE) rectifier is considered as an excellent technology. In this paper, current control for an AFE rectifier employing space vector PWM (Pulse Width Modulation) is proposed. Conventional current control methods for the AFE rectifier, hysteresis, SPWM (Sinusoidal Pulse Width Modulation), and SVPWM (Space Vector Pulse Width Modulation) were simulated by employing the PSIM software tool for analysis and comparisons. The results corroborate that SVPWM has the simplest structure and provides the best performance.

Load Dispatching Control of Multiple-Parallel-Converters Rectifier to Maximize Conversion Efficiency

  • Orihara, Dai;Saitoh, Hiroumi;Higuchi, Yuji;Babasaki, Tadatoshi
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1132-1136
    • /
    • 2014
  • In the context of increasing electric energy consumption in a data center, energy efficiency improvement is strongly emphasized. In a data center, electric energy is largely consumed by DC power supply system, which is based on a rectifier composed by multiple parallel converters. Therefore, rectifier efficiency must be improved for minimizing loss of DC power supply system. Rectifier efficiency can be modulated by load allocation to converters because converter efficiency depends on input AC power. In this paper, we propose a new control method to maximize rectifier efficiency. The method can control load allocation to converters by introducing active power converter control scheme and start-and-stop of converters. In order to illustrate optimal load allocations in a rectifier, a maximization problem of rectifier efficiency is formulated as a nonlinear optimization one. The problem is solved by Lagrangian relaxation method and the computation results provide the validity of proposed method.

Interleaved ZVS Resonant Converter with a Parallel-Series Connection

  • Lin, Bor-Ren;Shen, Sin-Jhih
    • Journal of Power Electronics
    • /
    • v.12 no.4
    • /
    • pp.528-537
    • /
    • 2012
  • This paper presents an interleaved resonant converter with a parallel-series transformer connection in order to achieve ripple current reduction at the output capacitor, zero voltage turn-on for the active switches, zero current turn-off for the rectifier diodes, less voltage stress on the rectifier diodes, and less current stress on the transformer primary windings. The primary windings of the two transformers are connected in parallel in order to share the input current and to reduce the root-mean-square (rms) current on the primary windings. The secondary windings of the two transformers are connected in series in order to ensure that the transformer primary currents are balanced. A full-wave diode rectifier is used at the output side to clamp the voltage stress of the rectifier diode at the output voltage. Two circuit modules are operated with the interleaved PWM scheme so that the input and output ripple currents are reduced. Based on the resonant behavior, all of the active switches are turned on under zero voltage switching (ZVS), and the rectifier diodes are turned off under zero current switching (ZCS) if the operating switching frequency is less than the series resonant frequency. Finally, experiments with a 1kW prototype are described to verify the effectiveness of the proposed converter.

Analysis and Control of a Modular MV-to-LV Rectifier based on a Cascaded Multilevel Converter

  • Iman-Eini, Hossein;Farhangi, Shahrokh;Khakbazan-Fard, Mahboubeh;Schanen, Jean-Luc
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.133-145
    • /
    • 2009
  • In this paper a modular high performance MV-to-LV rectifier based on a cascaded H-bridge rectifier is presented. The proposed rectifier can directly connect to the medium voltage levels and provide a low-voltage and highly-stable DC interface with the consumer applications. The input stage eliminates the necessity for heavy and bulky step-down transformers. It corrects the input power factor and maintains the voltage balance among the individual DC buses. The second stage includes the high frequency parallel-output DC/DC converters which prepares the galvanic isolation, regulates the output voltage, and attenuates the low frequency voltage ripple ($2f_{line}$) generated by the first stage. The parallel-output converters can work in interleaving mode and the active load-current sharing technique is utilized to balance the load power among them. The detailed analysis for modeling and control of the proposed structure is presented. The validity and performance of the proposed topology is verified by simulation and experimental results.

Model Predictive Power Control of a PWM Rectifier for Electromagnetic Transmitters

  • Zhang, Jialin;Zhang, Yiming;Guo, Bing;Gao, Junxia
    • Journal of Power Electronics
    • /
    • v.18 no.3
    • /
    • pp.789-801
    • /
    • 2018
  • Model predictive direct power control (MPDPC) is a widely recognized high-performance control strategy for a three-phase grid-connected pulse width modulation (PWM) rectifier. Unlike those of conventional grid-connected PWM rectifiers, the active and reactive powers of permanent magnet synchronous generator (PMSG)-connected PWM rectifiers, which are used in electromagnetic transmitters, cannot be calculated as the product of voltage and current because the back electromotive force (EMF) of the generator cannot be measured directly. In this study, the predictive power model of the rectifier is obtained by analyzing the relationship among flux, back EMF, active/reactive power, converter voltage, and stator current of the generator. The concept of duty cycle control in the proposed MPDPC is introduced by allocating a fraction of the control period for a nonzero vector and rest time for a zero vector. When nonzero vectors and their duration in the predefined cost function are simultaneously evaluated, the global power ripple minimization is obtained. Simulation and experimental results prove that the proposed MPDPC strategy with duty cycle control for the PMSG-connected PWM rectifier can achieve better control performance than the conventional MPDPC-SVM with grid-connected PWM rectifier.

A High Efficiency Active Rectifier for 6.78MHz Wireless Power Transfer Receiver with Bootstrapping Technique and All Digital Delay-Locked Loop

  • Nga, Truong Thi Kim;Park, Hyung-Gu;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.6
    • /
    • pp.410-415
    • /
    • 2014
  • This paper presents a new rectifier with a bootstrapping technique to reduce the effective drop voltage. An all-digital delay locked loop (ADDLL) circuit was also applied to prevent the reverse leakage current. The proposed rectifier uses NMOS diode connected instead of PMOS to reduce the design size and improve the frequency respond. All the sub-circuits of ADDLL were designed with low power consumption to reduce the total power of the rectifier. The rectifier was implemented in CMOS $0.35{\mu}m$ technology. The peak power conversion efficiency was 76 % at an input frequency of 6.78MHz and a power level of 5W.

Full-Wave Rectifier with Vibration Detector for Vibrational Energy Harvesting Systems

  • Yoon, Eun-Jung;Yang, Min-Jae;Park, Jong-Tae;Yu, Chong-Gun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.3
    • /
    • pp.255-260
    • /
    • 2016
  • In this paper, a full-wave rectifier (FWR) with a simple vibration detector suitable for use with vibrational energy harvesting systems is presented. Conventional active FWRs where active diodes are used to reduce the diode voltage drop and increase the system efficiency are usually powered from the output. Output-powered FWRs exhibit relatively high efficiencies because the comparators used in active diodes are powered from the stable output voltage. Nevertheless, a major drawback is that these FWRs consume power from the output storage capacitor even when the system is not harvesting any energy. To overcome the problem, a technique using a simple vibration detector consisting of a peak detector and a level converter is proposed. The vibration detector detects whether vibrational energy exists or not in the input terminal and disables the comparators when there is no vibrational energy. The proposed FWR with the vibration detector is designed using a $0.35-{\mu}m$ CMOS process. Simulation results have verified the effectiveness of the proposed scheme. By using the proposed vibration detector, a decrease in leakage current by approximately 67,000 times can be achieved after the vibration disappears.

Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.

Modified Trench MOS Barrier Schottky (TMBS) Rectifier

  • Moon Jin-Woo;Choi Yearn-Ik;Chung Sang-Koo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.2
    • /
    • pp.58-62
    • /
    • 2005
  • A trench MOS barrier Schottky (TMBS) rectifier is proposed which utilizes the upper half of the trench sidewall as an active area. The proposed structure improves the forward voltage drop by 20$\%$ in comparison with the conventional one without degradation in breakdown voltage. An analytical model for the field distribution is given and compared with two-dimensional numerical simulations.