• Title/Summary/Keyword: Acrylic Adhesive

Search Result 181, Processing Time 0.023 seconds

A Study on the Electron Beam Crosslinking of Acrylic Pressure Sensitive Adhesives for Polarizer Film (전자선 조사를 통한 편광필름용 아크릴계 고분자의 가교화 반응에 대한 연구)

  • Park, Jung-Jin;Choi, Hong-June;Ko, Hwan-Soon;Jeong, Eun-Hwan;Youk, Ji-Ho
    • Polymer(Korea)
    • /
    • v.36 no.3
    • /
    • pp.344-350
    • /
    • 2012
  • New pressure sensitive adhesives (PSAs) for polarizer film were prepared by electron beam (e-beam) radiation to acrylic copolymers, and their adhesive properties were investigated. The acrylic copolymers were synthesized by free radical polymerization of $n$-butylacrylate (BA), 2-hydroxyethyl methacrylate (HEMA), and acrylic acid (AA). The acrylic copolymers were coated on PET release films to a thickness of 25 ${\mu}m$, laminated to polarizer films, and then radiated with e-beam at room temperature. Gel fractions of all the acrylic copolymers after e-beam radiation at 50 kGy were higher than 93%, and their crosslinking densities were increased with increasing the content of HEMA units. PSA prepared by e-beam radiation of acrylic copolymer synthesized with a feed ratio of BA/HEMA/AA = 89.5/10/0.5 (w/w/w) at a dose of 50 kGy exhibited the best adhesion performances in terms of peel strength, creep resistance, durability and reliability, and light leakage. It is expected that the preparation method of PSAs via e-beam irradiation will improve the producibility and workability of polarizer film for liquid crystal display.

Performance of Adhesives for Bonding Fresh Concrete to Hardened Concrete under Application Conditions (신ㆍ구 콘크리트 접착제의 시공조건에 따른 성능)

  • 이찬영;심재원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.513-518
    • /
    • 2002
  • In vertical construction joint, adhesives such as epoxy, acrylic, latex, etc. have been usually used for bonding fresh concrete to hardened concrete. In this study, performance of adhesives under various application conditions was investigated through tests for slant shear and flexural strength. From the results of the tests, it is found that superior bonding performance can be obtained under good surface preparation without adhesive when high strength concrete is used.

  • PDF

Physical Properties of Silk Kayagum Strings Treated with Chemical Agents

  • Kim, Young-Dae;Chung, In-Mo;Woo, Soon-Ok
    • Proceedings of the Korean Society of Sericultural Science Conference
    • /
    • 2003.10a
    • /
    • pp.57-57
    • /
    • 2003
  • Kayagum strings are usually made of raw silk. It is in need of good vibration and durability during playing the Kayagum. This study was carried out to increase durability of the strings by treatment of water soluble acrylic adhesive. (omitted)

  • PDF

Anti-wrinkle Effect of Pressure Sensitive Adhesive Hydrogel Patches Containing Ulmi Cortex Extract (유백피 추출물을 함유한 하이드로겔 패치의 주름 억제 효과)

  • Lee, Tae-Wan;Kim, Sang-Nyun;Jee, Ung-Kil;Hwang, Sung-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.3
    • /
    • pp.193-199
    • /
    • 2004
  • The decreasing effect of wrinkle on the pressure sensitive adhesive hydrogel patches containing ulmi cortex extract and sorbitol as the drug for anti-wrinkle were investigated. In this study, hydrogels were prepared by the crosslinking reaction of acrylic polymers and aluminum ions produced by L(+)-tartaric acid hydrolysis of the dihydroxy aluminum aminoacetates. The inhibition concentration of ulmi cortex extract on the collagenase exhibited at 0.01%. Furthermore, the moisturizing effect of hydrogel patches formulated with sorbitol was higher than that without it. In vivo animal test in hairless mouse showed that the ulmi cortex-loaded hydrogel patches had about 31.2% of anti-wrinkle effect compared to blank (before attaching the patches). Human test showed that only 33% of subjects showed the decreasing of wrinkle during 8 weeks. In conclusion, the model pressure sensitive adhesive hydrogel patches in this study would be pharmaceutically applicable for the wrinkle treatment on the facial skin.

Comparative study of the shear bond strength of various veneering materials on grade II commercially pure titanium

  • Lee, Eun-Young;Jun, Sul-Gi;Wright, Robert F.;Park, Eun-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.1
    • /
    • pp.69-75
    • /
    • 2015
  • PURPOSE. To compare the shear bond strength of various veneering materials to grade II commercially pure titanium (CP-Ti). MATERIALS AND METHODS. Thirty specimens of CP-Ti disc with 9 mm diameter and 10 mm height were divided into three experimental groups. Each group was bonded to heat-polymerized acrylic resin (Lucitone 199), porcelain (Triceram), and indirect composite (Sinfony) with 7 mm diameter and 2 mm height. For the control group (n=10), Lucitone 199 were applied on type IV gold alloy castings. All samples were thermocycled for 5000 cycles in $5-55^{\circ}C$ water. The maximum shear bond strength (MPa) was measured with a Universal Testing Machine. After the shear bond strength test, the failure mode was assessed with an optic microscope and a scanning electron microscope. Statistical analysis was carried out with a Kruskal-Wallis Test and Mann-Whitney Test. RESULTS. The mean shear bond strength and standard deviations for experimental groups were as follows: Ti-Lucitone 199 ($12.11{\pm}4.44$ MPa); Ti-Triceram ($11.09{\pm}1.66$ MPa); Ti-Sinfony ($4.32{\pm}0.64$ MPa). All of these experimental groups showed lower shear bond strength than the control group ($16.14{\pm}1.89$ MPa). However, there was no statistically significant difference between the Ti-Lucitone 199 group and the control group, and the Ti-Lucitone 199 group and the Ti-Triceram group. Most of the failure patterns in all experimental groups were adhesive failures. CONCLUSION. The shear bond strength of veneering materials such as heat-polymerized acrylic resin, porcelain, and indirect composite to CP-Ti was compatible to that of heatpolymerized acrylic resin to cast gold alloy.

A Study of the Aging Properties of the Common Synthetic Resin Adhesives for Paper Conservation Purposes (시판용 접착제의 지류보존처리 적합성 판단을 위한 열화 특성 연구)

  • Sung, Yeonsim;Youm, Inkyung
    • Journal of Conservation Science
    • /
    • v.28 no.4
    • /
    • pp.387-394
    • /
    • 2012
  • Most of the libraries and archives that lacks conservation lab facilities, frequently apply common synthetic resin adhesives such as PVAc group(Pa), acrylic group(Ac) and PVP group(Pv) on simple repairs. The archival quality synthetic adhesive(Pa-1) that is used at the National Library of Korea and the common synthetic resin adhesives were selected for the experiments. Accelerated aging test was applied on the adhesive samples and change of the pH and chromaticity were measured for one month. As the result of the pH mesurments, Pa-1 and Ac-2 were at the acceptable pH range. As the result of the chromaticity mesurments, degree of yellowing(${\Delta}b^*$) showed smaller change to greater change in the following order; Pa-1

The Physical Properties of UV-curable Resin for the Restoration of Glass Cultural Properties and Its Application in Conservation Treatment (유리제 문화재 복원용 광경화성 수지의 물성 연구 및 적용)

  • Lee, Hae Soon;Na, Ah Young
    • Conservation Science in Museum
    • /
    • v.21
    • /
    • pp.1-16
    • /
    • 2019
  • This study investigated the material properties of UV-curable Resin in order to identify stable materials for use in the restoration of glass cultural properties. Tested samples were based on acrylic UV-curable Resin (SECURE CP-7321®), to which urethane UV-curable Resin (FLGPCL04 Clear®) was added in 10% increments to produce eleven samples. The results showed that all eleven samples had similar properties in terms of refractive index, density, adhesive strength, and anti-yellowing. But the surface hardness and compressive strength were optimal and effective for maintaining the shape of artifacts after restoration treatment when the proportion of urethane resin was in the range of 10-20%. Based on these findings, the mixing sample [acrylic UV-curable Resin(9) : urethane UV-curable Resin(1)] was applied in the conservation treatment of a glass cultural propertie (Hwangbuk 519) excavated from the North Mound of Hwangnamdaechong, Tomb in Gyeongju.

A Study on Synthesis of Starch-acryl Pressure Sensitive Adhesive by Soap-free Emulsion Polymerization (무유화제 유화중합에 의한 전분-아크릴 점착제의 합성에 관한 연구)

  • Song, Su-Hyun;Kim, Young-Seok;Cho, Ur-Ryong
    • Elastomers and Composites
    • /
    • v.44 no.4
    • /
    • pp.429-435
    • /
    • 2009
  • The pressure sensitive adhesives (PSA) were synthesized by soap-free emulsion polymerization of acrylic monomers such as butyl acrylate, 2-ethyl hexyl acrylate, and acrylic acid in the presence of starch as a protective colloid and copolymer. The peel strength and holding power of PSA were increased with starch contents due to the enhancement of gel content, But the initial tackiness of PSA was decreased with starch contents. The contact angle analysis of PSA indicated that the wettability was increased with starch contents owing to the increase of polarity by hydroxy group in starch. In the pH measurement of emulsion with time for biodegradability, the starch in the PSA accelerated the lowering of pH due to the formation of organic acids followed by decomposition of starch.

The effect of various commercially available bleaching agents on the microshear bond strength of composite resin to enamel

  • Chang, Hoon-Sang;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.219-225
    • /
    • 2004
  • This study evaluated the microshear bond strength of composte resin to teeth bleached with commercial whitening strips and compared with those bleached with home bleaching gel. Twelve extracted human central incisors were cut into pieces and central four segments were chosen from each tooth and embedded in acrylic resin. Four blocks with 12 tooth segments embedded in acrylic resin were acquired and numbered from group one to group four. Group 1 was bleached with Crest Whitestrips, group 2 with Claren, group 3 with Opalescence tooth whitening gel (10% carbamide peroxide). Group 4 was used as control. The bleaching procedure was conducted for 14 days according to the manufacturer's instructions ; the bleaching strips twice a day for 30 min and the bleaching gel once a day for 2hr. After bleaching, composite resin (Filtek Supreme) was bonded to the enamel surfaces with a self-etching adhesive (Adper Prompt L-Pop) using Tygon tube. Microshear bond strength was tested with a universal testing machine (EZ-test). The data were statistically analysed by one-way ANOVA. The study resulted in no statistical differences in microshear bond strength between the tooth segments bleached with 2 different whitening strips and bleaching gel. It can be concluded that the effect of bleaching with either commercial whitening strips or bleaching gel on enamel is minimal in bonding with self-etching adhesive to composite resin.

Studies on the Characteristic of Removal Type Pressure-Sensitive Acrylic Adhesives (4원 공중합체 박리형 아크릴 점착제의 특성에 관한 연구)

  • Seo, Young-Ok;Seul, Soo-Duk
    • Journal of Adhesion and Interface
    • /
    • v.1 no.1
    • /
    • pp.15-22
    • /
    • 2000
  • To prepare acrylic type pressure-sensitive adhesive, quarter polymers were synthesized from butylacrylate (BA), 2-ethylhexylacrylate (2-EHA), methyl methacrylate (MMA), 2-hydroxyethylmethacrylate (2-HEMA). The quarter polymer was identified by FT-IR. Molecular weight was measured by Gel Pearmeation Chromatograhy. Also, viscosity, solid content and peel strength were investigated. The peel strength was $160g_f/25mm$ when the volume ratio of feed monomer to solvent was 1.3:1 and the ratio was relevant to commercial usage. The pot life of adhesive was 30 s at the 50 m/min of heat treatment rate, and it indicated that the minimum drying time was 30 s. Not only weathering resistance keep up peel strength $160{\sim}180g_f/25mm$ after 1000 h, but also no residual remains.

  • PDF