• 제목/요약/키워드: Acoustic transducer

검색결과 393건 처리시간 0.021초

SH-EMAT를 이용한 알루미늄 박판의 두께감육 평가 (Evaluation of Thickness Reduction in an Aluminum Sheet using SH-EMAT)

  • 김용권;박익근
    • Journal of Welding and Joining
    • /
    • 제28권2호
    • /
    • pp.74-78
    • /
    • 2010
  • In this paper, a non-contact method of evaluating the thickness reduction in an aluminum sheet caused by corrosion and friction using SH-EMAT (shear horizontal, electromagnetic acoustic transducer) is described. Since this method is based on the measurement of the time-of-flight and amplitude change of guided waves caused from the thickness reduction, it provides information on the thinning defects. Information was obtained on the changes of the various wave features, such as their time-of-flight and amplitude, and their correlations with the thickness reduction were investigated. The interesting features in the dispersive behavior of selected guided modes were used for the detection of thinning defects. The measurements of these features using SH waves were performed on aluminum specimens with regions thinned by 7.2% to 29.5% of the total thickness. It is shown that the time-of-flight measurement provides an estimation of the thickness reduction and length of the thinning defects.

동지나해 저서어업자원의 조사연구 (Acoustic-Trawl Surveys for Demersal Fisheries Resources in the East China Sea)

  • 윤갑동
    • 수산해양기술연구
    • /
    • 제29권3호
    • /
    • pp.183-190
    • /
    • 1993
  • A cooperative Korea-Japan investigation for the demersal fisheries resources of the East China Sea carried out by using the training ship Oshoro Maru belong to Hok-kaido University, Japan, during 1-8 November, 1991. The research vessel sampled 15 stations with demersal trawls on the East China Sea, and 1,364 nautical miles of track line were surveyed hydroacoustically. The hydroacoustic observations were taken with a scientific echo sounder operating at two frequencies of 25 kHz and 100 kHz, and a microcomputer-based echo integrator. Fish samples were collected by demersal trawling, and temperature, salinity and dissolved oxygen were measured with a CTD system. The target strength of fish school was estimated from the relationship between mean scattering strength and catches caught by demersal trawling. The results obtained can be summarized as follows: 1. The mean backscattering strength for 15 layers occupied by demersal trawls at 25 kHz ranged from -70.4 dB to -59.1 dB. Then the catch per one hour ranged from 8.2 to 587.5 kg/hour. 2. The mean backscattering strength for the entire layer between transducer and seabed in the survey area of the East China Sea at 25 kHz and 100 kHz were -68.0 dB and -73.1 dB, respectively. 3. The mean fish-school target strength per one kilogram at 25 kHz and 100 kHz were -28.3 dB/kg, and -30.4 dB/kg, respectively.

  • PDF

무작위로 거친 표면에서의 후방복사 초음파 (Ultrasonic Backward Radiation on Randomly Rough Surface)

  • 권성덕
    • 비파괴검사학회지
    • /
    • 제25권1호
    • /
    • pp.9-14
    • /
    • 2005
  • 표면 거칠기가 다른 유리시편에 대해 후방 복사된 초음파 세기의 입사각 의존성(프로파일)이 측정되었다. 후방복사 세기와 레일리(Rayleigh) 표면파 속도는 표면 거칠기에 비례하였고 이 경향은 각기 초음파의 산란규칙과 경화현상으로 설명되었다. 후방복사 프로파일의 면적 역시 표면 거칠기에 민감함을 보여 표면상태에 대한 새로운 비파괴적 평가 변수의 가능성을 보였다. 레일리 각 C-스캔 기법은 화상 명도의 반전과 높은 신호대 잡음비(S/N)를 보여주었다.

유한 배플 원통 진동체의 수중 방사 임피던스에 대한 실험적 연구 (Experimental Study of the In-Water Radiation Impedance of the Finite Baffle Cylinder Radiator)

  • 김원호;윤종락
    • 한국음향학회지
    • /
    • 제13권2호
    • /
    • pp.23-29
    • /
    • 1994
  • 본 논문에서는 원통형 압전 진동체에 대한 수중 방사 임피던스를 유한 배플 구조에서의 측정 결과와 무한 배플 구조에서의 이론 결과를 비교하여 방사 임피던스에 대한 배플의 영향을 규명하였다. 배플의 길이가 증가할수록 방사 임피던스의 측정치는 무한 배플에서의 이론치에 접하하며, 배플의 영항은 방사저항에서 보다 방사 리액턴스에서 더 지배적 임을 보인다. 따라서 음향 변환기의 설계시 무한 배플 구조에서의 방사 임피던스 이론 결과를 적용하기 위해서는 배플길이에 따른 임피던스의 보상이 수행되어야 한다.

  • PDF

The Effects of Secondary Fuel Injection on Combustion Oscillation

  • Shigeru Tachibana;Laurent Zimmer;Park, Gyung-Min;Takeshi Yamamoto;Ufosawa, Yoji-K;Seiji Yoshida;Kazuo Suzuki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.376-379
    • /
    • 2004
  • The purpose of this work is to develop an effective active control system for combustion instabilities of premixed combustors. For the first step, the natural modes of combustion oscillation were investigated for a methane-air premixed combustor and the controls by secondary fuel injection were examined. The main premixed flame is stabilized by a swirler with orifices for secondary injection installed on the central hub. For sensing purposes, a pressure transducer and a chemiluminescence sensor were placed on the appropriate positions. The acoustic characteristics and the source of the oscillation were analyzed by those signals. To test the controllability, two methods of actuations by secondary fuel injection were examined. One is the open loop control and the other is the closed loop control. The comparison of the reduction levels of p $_{rms}$ shows that the closed loop control with a phase-shift injection performs best in this condition.ition.n.

  • PDF

A1$_2$O$_3$기판위에 반응성 RF 마그네트론 스퍼터로 증착한 AlN 박막의 SAW소자 응용에 관한 연구 (A Study on the AlN Thin Film on A1$_2$O$_3$ Substrate Prepared by Reactive RF Magnetron Sputtering System for SAW Device Application)

  • 고봉철;손진운;김경석;엄무수;남창우;이규철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권7호
    • /
    • pp.288-292
    • /
    • 2003
  • AlM thin film has been deposited on A1$_2$O$_3$ substrate by reactive radio frequency(RF) magnetron sputtering method under various operating conditions such as working pressure, fraction of nitrogen partial pressure, and substrate temperature. Scanning Electron Microscope(SEM), X-ray Diffraction(XRD), and Atomic Force Microscope(AFM) have been measured to find out structural properties and preferred orientation of AlN thin films. SAW velocity of IDTs/AlN/Si structure was about 5038[㎧] at the center frequency of 251.9[MHz] and insertion loss was measured to be relatively low value of 35.6[dB]. SAW velocity of IDTs/AlN/A1$_2$O$_3$ structure was improved to be about 5960[㎧] at the center frequency of 296.7[MHz].

A Study of the Couplant Effects on Contact Ultrasonic Testing

  • Kim, Young-H.;Song, Sung-Jin;Lee, Sung-Sik;Lee, Jeong-Ki;Hong, Soon-Shin;Eom, Heung-Seop
    • 비파괴검사학회지
    • /
    • 제22권6호
    • /
    • pp.621-626
    • /
    • 2002
  • The amplitude of a back-wall echo depends on the reflection coefficient of the interface between a transducer and a test material when using contact pulse-echo ultrasonic testing. A couplant is used to transmit ultrasonic energy across the interface, but has an influence on the amplitude of the pulse-echo signal. To investigate the couplant effect on pulse-echo ultrasonic testing, back-wall echoes are measured by using various couplants made of water and glycerine in a carbon and austenitic stainless steel specimens. The amplitude of the first back-wall echo and the apparent attenuation coefficient increases with the acoustic impedance of the couplant. The couplant having a higher value of the transmission coefficient is more effective for flaw detection. The reflection coefficient should be known in order to measure the attenuation coefficient of the test material.

Magnetic Resonance-Guided Focused Ultrasound in Neurosurgery: Taking Lessons from the Past to Inform the Future

  • Jung, Na Young;Chang, Jin Woo
    • Journal of Korean Medical Science
    • /
    • 제33권44호
    • /
    • pp.279.1-279.16
    • /
    • 2018
  • Magnetic resonance-guided focused ultrasound (MRgFUS) is a new emerging neurosurgical procedure applied in a wide range of clinical fields. It can generate high-intensity energy at the focal zone in deep body areas without requiring incision of soft tissues. Although the effectiveness of the focused ultrasound technique had not been recognized because of the skull being a main barrier in the transmission of acoustic energy, the development of hemispheric distribution of ultrasound transducer phased arrays has solved this issue and enabled the performance of true transcranial procedures. Advanced imaging technologies such as magnetic resonance thermometry could enhance the safety of MRgFUS. The current clinical applications of MRgFUS in neurosurgery involve stereotactic ablative treatments for patients with essential tremor, Parkinson's disease, obsessive-compulsive disorder, major depressive disorder, or neuropathic pain. Other potential treatment candidates being examined in ongoing clinical trials include brain tumors, Alzheimer's disease, and epilepsy, based on MRgFUS abilities of thermal ablation and opening the blood-brain barrier. With the development of ultrasound technology to overcome the limitations, MRgFUS is gradually expanding the therapeutic field for intractable neurological disorders and serving as a trail for a promising future in noninvasive and safe neurosurgical care.

이중 초음파 조사 시스템에서 진동부 사이의 거리가 초음파 화학 반응에 미치는 영향 (The Effect of Distance between Two Transducers on Sonochemical Reactions in Dual Irradiation Systems)

  • 김은경;손영규
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권5호
    • /
    • pp.39-45
    • /
    • 2013
  • Many researchers have studied the effectiveness of ultrasound in chemical and environmental engineering fields including material synthesis, pollutant removal, cleaning, extraction, and disinfection. Acoustic cavitation induced by ultrasound irradiation in aqueous phase can cause various sonophysical and sonochemical reactions without any chemicals. However most of the previous studies focused only on the relationships between ultrasonic conditions and the results of sonochemical reactions in lab-scale sonoreactors. As a results of this, only a few studies have been devoted to design and optimization of industrial scale sonoreactors. In this study, the effect of the distance between two opposite transducer modules on sonochemical reactions was investigated in single and dual irradiation systems (334 kHz) for four distances including 50, 100, 150, and 200 mm using KI dosimetry. It was found that the dual irradiation systems provided higher performance in terms of the zeroth reaction coefficient and the cavitation yield compared to the single irradiation systems. The sonochemiluminescence (SCL) images for the visualization of the cavitation field showed that cavitation active zone was larger and sonochemical reaction intensity was much higher in the dual irradiation system than in the single irradiation system.

양측 혼합성 난청 환자에서 Vibrant Soundbridge를 이용하여 시행한 인공중이이식술 1예 (A Case of Middle Ear Implantation Using the Vibrant Soundbridge in a Patient with Bilateral Mixed Hearing Loss)

  • 신용국;구자원;강진욱;송미현
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • 제61권12호
    • /
    • pp.705-709
    • /
    • 2018
  • It is challenging to achieve sufficient hearing gain in patients with mixed hearing loss. In chronic middle ear diseases, conventional passive reconstructive surgeries often result in suboptimal hearing gain and additional hearing aids may have limitations due to insufficient sound amplification, occlusion effect, acoustic feedback, and skin irritation. Middle ear implantation (MEI) using Vibrant Soundbridge (VSB) is another option for auditory rehabilitation in mixed hearing loss as well as sensorineural hearing loss. The floating mass transducer of VSB can be placed on various middle ear structures either directly or using different types of couplers in order to deliver vibratory mechanical energy to the cochlea. We report a patient who presented with bilateral mixed hearing loss due to chronic otitis media and had limitations using conventional hearing aids in the worse hearing ear. The patient was successfully treated with MEI using the Bell coupler together with middle ear surgery in a single step.